• 제목/요약/키워드: light-gauge steel

검색결과 19건 처리시간 0.024초

Fire resistance tests of LSF walls under combined compression and bending actions

  • Peiris, Mithum;Mahendran, Mahen
    • Steel and Composite Structures
    • /
    • 제43권4호
    • /
    • pp.483-500
    • /
    • 2022
  • Cold-formed steel wall panels sheathed with gypsum plasterboard have shown superior thermal and structural performance in fire. Recent damage caused by fire events in Australia has increased the need for accurate fire resistance ratings of wall systems used in low- and mid-rise construction. Past fire research has mostly focused on light gauge steel framed (LSF) walls under uniform axial compression and LSF floors under pure bending. However, in reality, LSF wall studs may be subject to both compression and bending actions due to eccentric loading at the wall to-roof or wall-to-floor connections. In order to investigate the fire resistance of LSF walls under the effects of these loading eccentricities, four full-scale standard fire tests were conducted on 3 m × 3 m LSF wall specimens lined with two 16 mm gypsum plasterboards under different combinations of axial compression and lateral load ratios. The findings show that the loading eccentricity can adversely affect the fire resistance level of the LSF wall depending on the magnitude of the eccentricity, the resultant compressive stresses in the hot and cold flanges of the wall studs caused by combined loading and the temperatures of the hot and cold flanges of the studs. Structural fire designers should consider the effects of loading eccentricity in the design of LSF walls to eliminate their potential failures in fire.

Distortional buckling of cold-formed lipped channel columns subjected to axial compression

  • Zhou, Wangbao;Jiang, Lizhong
    • Steel and Composite Structures
    • /
    • 제23권3호
    • /
    • pp.331-338
    • /
    • 2017
  • Cold-formed lipped channel columns (CFLCCs) have been widely used in light gauge steel constructions. The distortional buckling is one of the important buckling modes for CFLCCs and the distortional buckling critical load depends significantly on the rotational restrain stiffness generated by the web to the lipped flange. First, a simplified explicit expression for the rotational restraint stiffness of the lipped flange has been derived. Using the expression, the characteristics of the rotational restraint stiffness of the lipped flange have been investigated. The results show that there is a linear coupling relationship between the applied forces and the rotational restraint stiffness of the lipped flange. Based on the explicit expression of the rotational restraint stiffness of the lipped flange, a simplified analytical formula has been derived which can determine the elastic distortional buckling critical stress of the CFLCCs subjected to axial compression. The simplified analytical formula developed in this study has been shown to be accurate through the comparisons with results from the distortional buckling analyses using the ANSYS finite element software. The developed analytical formula is easy to apply, and can be used directly in practical design and incorporated into future design codes and guidelines.

냉간성형강 평트러스 시스템의 좌굴 거동에 관한 실험 연구 (Experimental Study on the Buckling Behavior of Cold-formed Steel Warren Truss)

  • 박완순;김갑득
    • 한국강구조학회 논문집
    • /
    • 제14권6호
    • /
    • pp.747-754
    • /
    • 2002
  • 기존 바닥조이스트의 문제점을 해결하기 위해 냉간성형강 평트러스 시스템에 대한 연구를 진행하였다. 냉간성형강 평트러스 시스템은 기존 스틸 조이스트 시스템과 유사한 구조형식을 취하고 있으며, 무게 대비 성능이 우수하고, 설비라인을 바닥 구조재와 동일 선상에 배치할 수 있다는 장점을 가지고 있다. 본 연구에서는 Square End Type(SE Type), Underslung Type(EE Type) 평트러스의 구조적 거동에 대한 분석과 더불어, AISI 설계기준을 토대로 평트러스의 설계하중에 대한 평가가 진행되었다. 그리고 휨 실험을 통해 평트러스의 좌굴 거동에 대한 조사를 진행하였다. 실험결과 SE Type 평트러스가 EE Type 평트러스 보다 집중하중에 유리한 것으로 확인되었으며, 약축방향에 대한 비보강길이가 평트러스의 성능에 중요한 영향을 미치는 것으로 분석되었다. 그리고 실험을 통해 측정된 평트러스의 좌굴하중은 AISI 설계기준 값을 충족시키는 것으로 확인되었다.

일반배관용 스테인리스강관 및 이음쇠의 소화설비 적용 방안 (Measures applied for fire protection system of Light gauge strainesss steel pipe and the fittings for ordinary piping)

  • 남준석;최진종;김영호;박주환
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2011년도 추계학술논문발표회 논문집
    • /
    • pp.83-86
    • /
    • 2011
  • 옥내소화전설비, 스프링클러설비 등 수계소화설비에 일반배관용 스테인리스강관과 그 연결에 필요한 이음쇠의 사용가능성을 적용사례, 내식성 등을 통해 확인하였고, 기존 수계소화 설비의 배관에 대한 개선방안을 도출하였다. 일반배관용 스테인리스강관 및 이음쇠는 국내의 경우 수도용으로 활발히 사용되고 있으며, 독일 영국 일본 미국 등의 수계소화설비에 사용되고 있음을 확인할 수 있었다. 강관과 이음쇠의 연결상태에서 내식성을 확인하기 위해 0.5 %와 3.5 %의 소금물을 관내에 주입한 후 28일 보관한 결과 이상이 없음을 확인하였다. 또한, 기존에 설치되어있는 수계소화설비는 배관계의 온도차에 의한 보상방법이 되어있지 않아 작동물질의 열팽창에 따라 강관, 이음쇠의 파손이 발생할 수 있음을 확인하었다.

  • PDF

Light Gauge Steel Frame의 해석 및 설계기법

  • 홍건호
    • 전산구조공학
    • /
    • 제10권1호
    • /
    • pp.70-74
    • /
    • 1997
  • LGSF Housing의 설계는 기존의 2*4 목조주택의 설계방법을 그대로 수용하되 박판의 강재를 사용한다는 특성에 따라 부재의 좌굴특성을 고려하는 점에서 큰 차이가 있다고 볼 수 있다. 따라서 부재의 허용내력은 부재의 형상에 따라 그 좌굴모드가 결정되고 각 모드 중 최소의 값이 부재의 최종 허용내력으로 결정된다. 이와 같은 성상을 살펴볼 때 LGSF Housing은 사용되는 자재의 단면형상 개발에 따라 그 내력의 증진을 기대할 수 있으며, 이에 대한 연구의 필요성이 크다고 볼 수 있다. 또한, 스틸하우스는 공장에서 제작된 스터드의 현장조립에 의하여 시공되므로 이들 부재간의 접합방법에 큰 영향을 받게 된다. 기존 외국의 시공사례를 살펴보면 부재간의 접합은 주로 핸드건 등에 의한 스크류를 사용한 접합방법이 이용된다. 따라서, 이러한 접합방법의 내력평가방법도 해결되어야 할 문제점으로 볼 수 있다. 이러한 제반 문제점 등이 해결된다면 LGSF Housing은 건설공기의 단축을 기할 수 있고, 시공의 신속.편리성을 도모할 수 있으며, 자원의 재활용이 가능하고 향후 벽체 패널의 공장생산 등을 통한 공업화 건축이 가능하다는 점 등을 고려할 때 국내 저층구조물의 설계에 새로운 방향을 제시할 수 있을 것으로 기대된다.

  • PDF

일반배관용 스테인리스강관에 대한 프레스식 관이음쇠의 내진성능에 관한 연구 (A Study on the Seismic Protection Performance of Press Fittings for Light Gauge Stainless Steel Pipes)

  • 백열선;남준석
    • 한국화재소방학회논문지
    • /
    • 제31권4호
    • /
    • pp.65-70
    • /
    • 2017
  • 본 연구는 최근 수계소화설비 배관에 적용되고 있는 스테인리스 강관용 프레스식 관이음쇠에 대한 내진성능 연구를 수행한다. 연구를 위한 설비의 구성은 NFPA 13의 배관연결방법으로 하였다. 배관의 허용변위량은 건축구조기준에서 제시한 허용량으로 하였고, 반복회수는 10회로 하였다. 실험 후 배관의 Von-mises 응력은 허용응력의 2.48, 1.25배로 NPPs Allowable Stress for Level D service loading의 "허용응력의 3배"인 기준 보다는 적게 나타났다. 따라서 프레스식 관이음쇠는 내진성능을 갖추고 있는 것으로 판단 할 수 있다.

Comparative study of finite element analysis and generalized beam theory in prediction of lateral torsional buckling

  • Sharma, Shashi Kant;Kumar, K.V. Praveen;Akbar, M. Abdul;Rambabu, Dadi
    • Advances in materials Research
    • /
    • 제11권1호
    • /
    • pp.59-73
    • /
    • 2022
  • In the construction industry, thin-walled frame elements with very slender open cross-sections and low torsional stiffness are often subjected to a complex loading condition where axial, bending, shear and torsional stresses are present simultaneously. Hence, these often fail in instability even before the yield capacity is reached. One of the most common instability conditions associated with thin-walled structures is Lateral Torsional Buckling (LTB). In this study, a first order Generalized Beam Theory (GBT) formulation and numerical analysis of cold-formed steel lipped channel beams (C80×40×10×1, C90×40×10×1, C100×40×10×1, C80×40×10×1.6, C90×40×10×1.6 and C100×40×10×1.6) subjected to uniform moment is carried out to predict pure Lateral Torsional Buckling (LTB). These results are compared with the Finite Element Analysis of the beams modelled with shell elements using ABAQUS and analytical results based on Euler's buckling formula. The mode wise deformed shape and modal participation factors are obtained for comparison of the responses along with the effect of varying the length of the beam from 2.5 m to 10 m. The deformed shapes of the beam for different modes and GBTUL plots are analyzed for comparative conclusions.

농촌마을 지붕경관 특성에 관한 조사 연구 - 가로변 농촌마을을 대상으로 - (A Study on the Roof Landscape Characteristics of Rural Villages - Focused on Road-Side Rural Villages -)

  • 김윤학
    • 한국농촌건축학회논문집
    • /
    • 제15권3호
    • /
    • pp.17-24
    • /
    • 2013
  • This study examined and investigated architectural characteristics such as the use of buildings, the number of layers, and structure, and roof landscape characteristics such as roof types, materials, and color in rural villages which were located on the street on the assumption that the landscape of rural villages should be managed by considering visual aspects. The results were as follows. The commonest frequency was found in 'residence'(2/3) for the use of buildings and 'masonry structure'(2/3) for the structure. 'Wood structure' and 'light gauge steel structure(prefabricated structure)' were also commonly found. The results suggest that although many rural houses have partially improved by agricultural and fishery development projects and garden suburbs has been increased by city residents' desire for rural life, there have been still many old houses. Frequently used roof types were a gambrel roof and a hipped roof. Roof materials were mixed in several materials such as tiles, slate, panels, color steel plate, reinforced concrete, and asphalt shingles. Roof color was also mixed in several colors such as reddish N7 and N0.5 of Neutral color, 10R3/6 and 10R3/10 of R color, 7.5B4/10 and 7.5B7/8 of B color and 5G8/6 of G color. The result suggests that roof color impedes the landscape of rural villages on the street. Based on the results, some roofs of rural villages were improved by the support of the government or the local governments but there are still many old roofs. The mixture of improved roofs and old roofs mainly contributed to impeding the landscape of rural villages and it was probably caused by the lack of systematic landscape plans by individual improvement of buildings. Therefore, it is necessary to devise systematic landscape plans in consideration of local identity and neighboring environment. In particular, the guideline for roof color influencing a street landscape should be established.

반강성(半剛性) 및 강성고정(剛性固定)이 두개안면골(頭蓋顔面骨)의 성장(成長)에 미치는 영향(影響)에 관한 연구(硏究) (THE COMPARATIVE STUDY OF THE EFFECT OF THE SEMI RIGID AND RIGID FIXATIONS OF THE GROWTH OF THE CRANIOFACIAL SKELETON)

  • 이상철;김여갑
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제15권3호
    • /
    • pp.157-170
    • /
    • 1993
  • To prove the effct of semi-rigid fixation which utilize wire and rigid fixation which utilizes miniplate toward cranio-facial growth and development of growing children for teenagers, 28 rabbits-6 weeks, about 1.5kg-were experimented. They were classified three groups the semi-rigid group was 12 rabbits which were fixed with 26 gauge stainless steel wire to cross a fronto-nasal suture, the rigid group was the other 12 rabbits which were fixed with miniplate and screw, the control group was 4 rabbits which were get rid of only periosteum. The sample of fronto-nasal of rabbits which were sacrified after 2 weeks, 4 weeks, 8 weeks, and 12 weeks of the operation were investigated and made a comparative study with the light microscops. 1. At the control group, the central part of bony suture was connected with colagen bundle, the osteoblastic layer was investigated at the bony ending, new bone which covered the inside and outside faces of the bone suture was formed between periosteum. 2. Two weeks later from the experiment, ran slightly irregularly the collagen bundle which connects both bony endings of the rigid group. 3. Four weeks later from the experiment, collagen bundle of bone surface were arranged parally a little and comparing to the semi-rigid group, newly formed woven bone of surface of the adjacent bone was made obviously a little. 4. Eight weeks later from the experiment, collagen bundle which is located between both bony ending become close. Both the semi-rigid group and the rigid group showed significant formation of new bone at the periosteum and the bone surface. 12 weeks later from the experiment, both the semi-rigid group and the rigid group showed the regular running in the collagen bundle and smooth, dense periosteum. Then they assumed a similar aspect of the control group. I think that it does not give the influence to the cranio-facial growth of children or teenager to utilize a rigid fixation for a short period. Because as the time goes on, the surface of the bone suture was recovered and adjacent bone surface of the miniplate fixation showed compensatory growth, although both the semi-rigid group which utilized wire and rigid group which utilized a miniplate brought about the change of the area of the bone suture at the early period.

  • PDF