• 제목/요약/키워드: light transformer

검색결과 109건 처리시간 0.042초

Application of an Optical Current Transformer For Measuring High Current

  • Kim, Yeong-Min;Park, Won-Zoo
    • 조명전기설비학회논문지
    • /
    • 제24권11호
    • /
    • pp.9-16
    • /
    • 2010
  • This paper examines the temperature characteristics of an Optical CT (optical current transformer) using the Faraday effect for measuring high current in a super high voltage-power apparatus. It is performed as follows by the sensor for embodying Faraday effect. $\cdot$ A single-mode optical fiber capable of maintaining a polarization state is used. $\cdot$ A light source is applied at 1310[nm] to a Laser Diode. $\cdot$ The Linear of Faraday effect to a large current is evaluated and $\cdot$ A possible application using an Optical CT was shown. An Influence of Faraday effect to the surrounding temperature measured -40~50[$^{\circ}C$], and the characteristic of the current sensitivity was reported. An application using the results of the temperature compensation system was used in order to compensate for surrounding temperatures. A possibility of applying Optical CT for electric power apparatus was advanced further. We were able to confirm that this temperature calibration method can minimize the fluctuation of the output signal depending on the temperature conditions.

패시브 공진 스너버를 이용한 플라이백형 ZVS PWM DC-DC 컨버터의 특성해석 (Characteristic Analysis of Flyback Type ZVS PWM DC-DC Converter Using Passive Resonant Snubber)

  • 김정도;문상필;박한석
    • 전기학회논문지P
    • /
    • 제65권3호
    • /
    • pp.158-164
    • /
    • 2016
  • In this paper, a high frequency flyback type zero voltage soft switching PWM DC-DC converter using IGBTs is proposed. Effective applications for this power converter can be found in auxiliary power supplies of rolling stock transportation and electric vehicles. This power converter is basically composed of active power switches and a flyback high frequency transformer. In addition to these, passive lossless snubbers with power regeneration loops for energy recovery, consisting of a three winding auxiliary high frequency transformer, auxiliary capacitors and diodes are introduced to achieve zero voltage soft switching from light to full load conditions. Furthermore, this power converter has some advantages such as low cost circuit configuration, simple control scheme and high efficiency. Its operating principle is described and to determine circuit parameters, some practical design considerations are discussed. The effectiveness of the proposed power converter is evaluated and compared with the hard switching PWM DC-DC converter from an experimental point of view and the comparative electromagnetic conduction and radiation noise characteristics of both DC-DC power converter circuits are also depicted.

비전 트랜스포머 인코더가 포함된 U-net을 이용한 대장 내시경 이미지의 폴립 분할 (U-net with vision transformer encoder for polyp segmentation in colonoscopy images)

  • 겔란 아야나;최세운
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2022년도 추계학술대회
    • /
    • pp.97-99
    • /
    • 2022
  • 대장암의 조기 발견과 치료를 위해서는 정확한 폴립의 분할이 중요하나 다음과 같은 제약이 따른다. 개별 폴립의 위치, 크기 및 모양이 서로 상이하며, 모션 흐림 및 빛 반사와 같은 특정 상황에서 폴립과 주변 환경 간에 상당한 정도의 유사성이 존재한다. 인코더와 디코더 역할을 하는 Convolutional Neural Networks로 구성된 U-net은 이러한 한계를 극복하기 위해 다양하게 사용된다. 본 연구는 보다 정확한 폴립 분할을 위한 비전트랜스포머가 포함된 U-net 아키텍처를 제안하였고, 그 결과 제안된 방식은 표준 U-net 아키텍처보다 더 나은 성능을 보였음을 확인할 수 있었다.

  • PDF

배터리 구동 전자레인지를 위한 직렬 공진형 풀브릿지 인버터 (Series Resonant Full Bridge Inverter for Battery-fed Microwave Oven)

  • 鄭 龍 采;韓 盛 軫
    • 전력전자학회논문지
    • /
    • 제7권2호
    • /
    • pp.165-170
    • /
    • 2002
  • 이단 전력변환에 따른 시스템 효율의 감소문제를 해결하기 위해서 배터리 구동 전자레인지를 위한 직렬 공진형 풀 브릿지 인버터 회로를 제안한다. 이 회로는 기존의 HVT(High Voltage Transformer) 방식과 비교해서 콤팩트 한 크기를 가지며 무게 또한 가볍다. 또한, 주파수 제어로 전자레인지의 출력단계를 조절할 수 있다. 본 논문에서는 회로 동작을 이해하기 위해서 동작원리를 자세히 설명하였다. 또한, 1[kW] 소비전력을 갖는 프롯타입 인버터 회로를 제작하고 시험을 통하여 동작을 확인하였다.

에폭시 스페이서에 내장되는 전류센서와 전압센서의 출력 특성 (Output Characteristics of Current Sensor and Voltage Sensor Built in Epoxy Spacer)

  • 박성희;김길수;강성화;임기조
    • 전기학회논문지
    • /
    • 제56권2호
    • /
    • pp.361-366
    • /
    • 2007
  • In the distribution networks, it is necessary to develop small and light voltage and current sensor for compact and digitalized switchgears. For this purpose, some researches have been continuing till now, CT(current transformer) and VT(voltage transformer) are one of that research. But conventional CT and VT have some problems, that is, have big size and saturation characteristics because of used to iron core. In this paper, CS(current sensor) and VS(voltage sensor), have some merits measuring of current and voltage magnitude as a alternated conventional equipment, were studied. So, this paper shows the process CS and VS design method, equivalent circuit and output result, respectively. As a result of this test, proposed CS and VS have linearity for the output, no saturation.

편광측정법을 이용한 광전류 센서의 온도특성 (Temperature Characteristic of Optical Current Transformer Used Porlarimetric Method)

  • 박상만;안병립;원우식;우형관;이성갑
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1430-1431
    • /
    • 2008
  • In this paper, a optical current transformer has been designed and favricated to improve temperature stability caused materials properties and insulation in measuring system, suing single crystal as faraday effect cells. We used 850[nm] Laser diode as the light source and PIN Photodiode as receiver. For the experiment, the temperature transformation device make by aluminum. The range of current was from 0[A]$\sim$1600[A] and the range of temperature was from -20[$^{\circ}C$] to 50[$^{\circ}C$]. In a same experimental condition magnitude increased input current increase follow by increasing proportion of input current. The result of this study shows that characteristics of OCT are good, and it can be reflected for practical optical sensors.

  • PDF

클램프헝 부피 광 전류센서 (Clamp-type Bulk Optic Current Sensor)

  • 정현;이용욱;김수길;이병호;박병석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1924-1926
    • /
    • 2002
  • The optical current transformer using Faraday effect is the sensor to measure current that flows in any conductor. This sensor doesn't undergo the magnetic saturation and effect of adjacent conductors. But this senor using bulk-glass sensing clement has crucial drawback. It is impossible that the sensor is mounted to conductor without breaking the closed-loop of light or conductor. So we developed the clamp-type optical current transformer and made an experiment.

  • PDF

전압 리플을 이용해 영전류스위칭하는 두개의 트랜스포머를 가지는 위상천이 풀-브릿지 컨버터 (Zero-Current Switching Two-Transformer Phase-Shift Full-Bridge Converter using Voltage Ripple)

  • 윤현기;문건우;윤명중
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.436-438
    • /
    • 2005
  • This paper presents a Zero-Current Switching(ZCS) two-transformer phase-shift full-bridge(TTFB) converter using voltage ripple. The proposed converter provides Zero-Voltage Switching(2VS) of leading leg switches and ZCS of lagging leg switches using volt-age ripple. Especially, circulating current Is reduced by ZCS operation and there are no additional components required for the soft switching of power switches. Furthermore, in case of light load, ZVS operation of lagging leg can be achieved. The operations, analysis and design consideration of proposed converter are presented. To verify the validity of the proposed converter, experimental results for a flow (205V, 2A) prototype are presented.

  • PDF

A New High Efficiency Half Bridge Converter with Improved ZVS Performance

  • Lee Sung-Sae;Han Sang-Kyoo;Moon Gun-Woo
    • Journal of Power Electronics
    • /
    • 제6권3호
    • /
    • pp.187-194
    • /
    • 2006
  • A new asymmetrical pulse width modulation (PWM) half bridge converter with improved ZVS performance is proposed. The ZVS operation of the proposed converter can be maintained from no load to full load conditions since the magnetizing current of the transformer contributes to the ZVS operation at light loads without considerable conduction loss of the transformer and switch. Synchronous rectification is employed to reduce the rectification loss. Operational principles, large signal modeling, ZVS analysis and design equations are presented. Experimental results demonstrate that the proposed converter can achieve a large ZVS range and significant improvement in efficiency for a 100W (5V, 20A) prototype converter.

PRACTICAL EVALUATIONS OF PARASITIC RESONANT PWM DC-DC CONVERTERS FOR HIGH-POWER MEDICAL USE

  • H. Takano;J. Takahashi;Sun, J.M.;L... Gamage;M. Nakaoka
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.701-708
    • /
    • 1998
  • This paper presents a novel non-resonant PWM DC-DC converter for X-ray high-voltage power generator using the parasitic impedances of the high-voltage high-frequency link transformer with its output high-voltage control scheme and steady-state characteristics compared to the conventional series-parallel resonant DC-DC converter. The key point of this approach is to evaluate effectiveness of reduction of the turn ratio of the high-voltage high-frequency transformer on improvements in power conversion efficiency and the power factor applying a boost AC-DC converter as DC voltage source, especially in the long exposure term and light output load ranges.

  • PDF