• 제목/요약/키워드: light installation cost

검색결과 61건 처리시간 0.018초

의료시설의 치유적 환경을 위한 자연광조명시스템에 관한 연구 (A Study on Daylighting Systems for Therapeutic Environments of Healthcare Facilities)

  • 정희분
    • 한국실내디자인학회논문집
    • /
    • 제25권6호
    • /
    • pp.139-148
    • /
    • 2016
  • Chronic patients and staffs in healthcare facilities cannot avoid long-term stays indoors. Therefore, they need to get adequate amounts of sunlight to prevent diseases caused by vitamin D deficiency. This is a case study on the advanced daylighting systems installed to healthcare facilities for therapeutic environments as serving natural light therapy and a pleasant atmosphere. This paper shows daylighting devices that overcome the structural limits of architectural design solutions for inducing natural light. This study presents appropriate daylighting technologies to the purpose and types of healthcare facilities by analyzing therapeutic environmental factors. Natural light delivered through daylighting devices help directly patients recover. In addition, it can improve healthcare providers' performance and productivity, and reduce their errors, thereby creating therapeutic environments for patients, indirectly. Excellent color rendering of solar illumination is also a powerful tool for navigation and wayfinding in the buildings, and for aesthetic treatment in dental office. Furthermore, daylighting systems are streamlined and require the least material and space to attract sunlight up to the deeper inside. But because of expensive cost, they have not yet been widespread. Though daylighting devices are typically more expensive than artificial illuminations to install, the running cost savings can compensate for the initial installation cost. With the development of technology in the future, the market price of them is expected to be formed properly.

자연광 다층 작물재배를 위한 광선반 시스템에 관한 연구 (Exploration of a Light Shelf System for Multi-Layered Vegetable Cultivation)

  • 장성택;장성주
    • KIEAE Journal
    • /
    • 제13권2호
    • /
    • pp.61-66
    • /
    • 2013
  • This study is to eliminate the need for conventional high density plant factory's artificial light source such as LED to reduce the initial investment of the light source installation as well as the operation cost. Use of solar light could enhance the quality of the vegetables similar to those grown in the natural environment. Provision of solar light into the multilayer vegetable cultivation facilities and collecting maximum and sustainable sunlight without too much loss by tracing solar path and properly distributing it through careful control during daytime are crucial for realizing the investigated rooftop light shelf system for multi-layered vegetable cultivation. In this study, we developed an innovative way of effectively allocating sunlight inside even to otherwise shaded zone of a multi-layer vegetable cultivation facility. To prove the effectiveness of the system's sunlight collection and distribution capability, both simulation and experiment in Daejeon are performed and the outcome is analyzed.

Implementation of Spatial Light Modulator(SLM) using a Commercial LCD Beam Projector

  • Ko, Jung-Hwan;Lee, Jae-Soo
    • 조명전기설비학회논문지
    • /
    • 제20권9호
    • /
    • pp.1-10
    • /
    • 2006
  • In this paper, a new high resolution XGA-SLM is implemented through modification of a commercial TFT-LCD beam projector and its optical modulation characteristics as a spatial light modulator(SLM) is also analyzed. First, the optics module, projection lamp and fans are removed from a commercial beam projector and instead some electric circuits to compensate their removal are manufactured and then, by inserting them into the beam projector, a new XGA-SLM is finally implemented. Second, from some optical experimental results, this TFT-SLM is found to have a good optical linearity in amplitude and phase modulation characteristics as a function of the input gray levels. Especially, through implementation of a binary phase-type correlator such as BPEJTC by using the suggested TFT-LCD panel, the implemented SLM is proposed as a new relatively low-cost and high resolution SLM for optical information processing.

Comparative study on the effect of cooling & heating loads by lighting energy of various light sources in an office building

  • Hong, Won Pyo
    • 조명전기설비학회논문지
    • /
    • 제30권3호
    • /
    • pp.94-105
    • /
    • 2016
  • The objective of the work was to evaluate the impact of lighting energy to cooling and heating consumption in medium scale office building, when currently installed fluorescent lights were replaced with various LED lighting fixtures. This evaluation comes from an integrated approach combining the proper indoor lighting environment and the thermal aspects of cooling & heating consumption in office building. These simulations were performed by coupling an appropriate luminaire analysis for energy consumption and a dynamic thermal simulation software (TRNSYS). To analyze comparative study of effects on the heating, cooling loads, and energy consumption of an LED lamp application, 2 types of LED lamp with low light power watt(LPW) 24W and high LPW 7.5W and a fluorescent lights(FL) with 37W are used respectively. Integrated building energy consumption decreased up to 3.2% when fluorescent lamps were replaced with LEDs. Thus, the high LPW of LED(7.5W) replaced with the same number of FL shows an effective energy saving and cost- effective luminary.

다양한 형태의 조명(형광등) 전력제어 실증시험을 통한 비용효과적인 전력수요관리방법 도출 (A Study on the Cost Effective DSM Method for Lighting Power Control through Pilot Test Based on Pre-Verified Methodologies)

  • 양승권;김대영
    • 조명전기설비학회논문지
    • /
    • 제27권2호
    • /
    • pp.7-13
    • /
    • 2013
  • The portion of lighting power consumption for our country is up to 20~30% of the total amount. Currently, most of the DSM(Demand side management) of lighting power is delivered in supply of high efficient lighting to customers. On the contrary, applications of lighting power to power load leveling are still rare. In this paper, the simulations for various control types of lighting power for load leveling are tried, and we obtained the cost effective and optimal control method through that. This simulation was executed in test office with fluorescent light by us based on applying 8 control types(on, off & dimming), considering customers' satisfaction, for instance, minimum intensity of illumination allowed. According to the result of this test, we found that mixed type(chessboard(on-off) plus dimming control(10%)) is most effective.

PWM 정류기를 적용한 직류급전시스템의 전압강하 및 비용 평가 (Analysis on Voltage and Cost of Substation with PWM Rectifier in DC Traction Power Supply System)

  • 김주락;박기준;박창릉;추은상;이준영
    • 전기학회논문지
    • /
    • 제64권4호
    • /
    • pp.640-645
    • /
    • 2015
  • Near surface transit system has should be constructed as installation cost of light rail transit with elevated track. So, distance between two substations is longer than conventional system. The long feeding distance results in severe voltage drop. This paper proposes a PWM rectifier instead of diode rectifier. The PWM rectifier has some advantages. This is able to control output voltage constantly to reduce voltage drop and to use regeneration power without additional inverter. This paper analyse on improved voltage profile and cost of substation with PWM rectifier. The analysis of voltage profile use PSIM, and the installation cost of substation with PWM rectifier is compared to substation with diode rectifier.

광학적 연기밀도 측정을 위한 저가형 장치의 개발에 관한 연구 (A Study on the Development of a Low-cost Device for Measuring the Optical Smoke Density)

  • 김봉준;조재호;황철홍;박설현
    • 한국화재소방학회논문지
    • /
    • 제29권4호
    • /
    • pp.81-88
    • /
    • 2015
  • 본 연구에서는 다양한 화재실험에서 광학 연기밀도 측정을 위하여 광소멸법을 이용한 저가형 장치가 개발되었다. 저가형 장치의 상대적 측정 정확도는 He-Ne 레이저, 포토디텍터 및 다양한 광학부품을 이용한 고가의 표준장치에 의해 측정된 연기밀도의 비교를 통해 평가되었다. 저가형 장치는 레이저 모듈, 포토셀 그리고 아크릴 보드로 구성되었다. 연기농도의 조절이 용이한 연기 발생장치 실험을 통해, 저가형 장치는 표준장치에 비해 ${\pm}10%$의 범위 내에서 연기밀도를 측정할 수 있음을 확인하였다. 저가 장치의 신뢰성은 또한 폴리에틸렌 화염을 이용한 실험에서도 확인되었다. 결론적으로 개발된 저가형 장치는 연기밀도 측정을 위한 간편한 설치 및 실시간 측정과 함께 고가의 표준장치를 대신하여 사용될 것으로 기대된다.

국내 최초 소형차 전용 도심지 대심도 복층터널 설계 사례 (A Case Study for the 1st Double-level Tunnel for Light vehicle in Urban Area in Korea)

  • 김경훈;최준동;전덕찬;신일재;심동현
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 추계 학술발표회
    • /
    • pp.1302-1313
    • /
    • 2010
  • The west express way is notorious for extremely heavy traffic area in the west of Seoul, South Korea. Hence, the city government recently initiated a new underground BTO (Build-Transfer-Operate) road project to solve traffic congestion and a high construction cost. The proposed underground express road being designed is the first double-level tunnel ever designed in South Korea and using Conventional tunnelling method (NATM). A total length of tunnel for light vehicles is 10.91km long including both open cut structures and concrete lining with middle-deck in bored tunnel. There are also 4 ventilation shafts for ventilation and evacuation on emergency. Many design issues had been aroused during the preliminary design phase and detail design phase is currently going on. This paper discusses design focuses including excavation methods, ground water issues, a deck slab installation, and a construction cost etc. for the double level road tunnel design of urban area.

  • PDF

식물공장을 위한 인공광 회전형 스마트 조명 제어시스템 개발 (Development of the Rotational Smart Lighting Control System Using Artificial Light for Plant Factory)

  • 이원섭;김성관
    • 한국산학기술학회논문지
    • /
    • 제13권4호
    • /
    • pp.1474-1479
    • /
    • 2012
  • 회전형 스마트 조명 제어시스템은 작물 재식판에 위치한 작물들에게 필요한 광을 회전하며 공급하는 시스템이다. 기존 식물공장은 무수히 많이 설치되는 LED와 형광등과 같은 조명장치에 따라 고가의 초기 조명 시스템 설치비용이 발생 된다. 이에 본 논문은 비교적 적은 양으로 설치된 조명장치를 회전시키는 시스템을 개발하였으며, 식물이 생장하는데 필요한 광량과 광속, 광양자속 밀도(PPFD)를 계산하였다. 조명 시뮬레이션 프로그램 Relux와 시제품을 이용한 실험을 통하여 조명 모듈의 각도 변화와 블레이드의 회전속도 변화에 따른 측정 영역에서의 광량의 차이를 비교하고 분석하였다.

하이브리드 광섬유 센서 시스템을 이용한 풍력발전기의 다중물리량 상태감시 (A Hybrid Fiber-Optic Sensor System for Multi-Stress Condition Monitoring of Wind Turbines)

  • 김대길;김현진;송민호
    • 조명전기설비학회논문지
    • /
    • 제29권8호
    • /
    • pp.76-82
    • /
    • 2015
  • A hybrid fiber-optic sensor system which combines fiber Bragg grating sensors and a Michelson interferometer has been constructed and evaluated for condition monitoring of large scale wind turbines. In order to measure multiple stresses applied to wind turbines such as strain, temperature and vibration, the system uses single broadband light source. It addresses both types of sensors, which simplifies the optical setup and enhances the cost-effectiveness of condition monitoring system. An athermal-packaged FBG is used to supply quasi-coherent light, of which coherence length is about 3.28mm, for the Michelson interferometer demodulation. Experimental results demonstrated that the proposed fiber-optic sensor system was capable of measuring strain and temperature with measurement accuracy of 1pm. Also 500~2000Hz vibration signals were successfully analyzed by applying FFT signal processing to interference signals.