• Title/Summary/Keyword: light field

Search Result 2,440, Processing Time 0.033 seconds

Influence of Copper Azole Retention Level to Wood Decay (목재 내 Copper Azole 보유량이 목재부후에 미치는 영향)

  • Lee, Hyun-Mi;Son, Dong-Won;Lee, Han-Sol;Hwang, Won-Joung
    • Journal of the Korean Wood Science and Technology
    • /
    • v.43 no.1
    • /
    • pp.112-121
    • /
    • 2015
  • In this study, Copper Azole (CuAz), a domestically available wood preservative for pressure treatment, was employed to perform an experimental research on its infiltration and decay properties in Japanese Red Pine. Test specimens were pressure-injected with CuAz-2 preservative to measure its preservative effectiveness, and then its impact on weight and mass losses. Furthermore, wood specimens were treated with CuAz-2 preservatives of various concentration levels before they were decayed with brown-rot-fungi in order to observe decay properties on light microscope (LM) and field emission scanning electron microscope (FE-SEM). As a result, untreated specimen by Fomitopsis palustris showed the mass loss of more than 40%, and the value of preservative effectiveness of CuAz-2 by indoor decay was $1,73-3.32kg/m^3$. The concentration levels of CuAz-2 preservative were shown to cause significant variations in terms of decay progresses in the cross section, radial section, and tangential section. By contrast, untreated specimens had underwent serious decays in early wood, late wood, longitudinal resin canals, and ray, which led to vertical destruction of wood texture. As for the radial section, ray tracheid, ray parenchyma cell, and window like pits were decayed and destroyed. In the case of tangential section, uniseriate rays and vertical resin canals were seriously decayed. In conclusion, this study indicates that the adequacy of the current CuAz injection amount should be reviewed in the domestic environment because there are significantly different decays at different decay conditions.

Photoluminescence Characteristics of (Ca, Sr)2MgSi2O7:Eu2+ Phosphor Particles Prepared by Spray Pyrolysis (분무열분해법에 의해 제조된(Ca, Sr)2MgSi2O7:Eu2+ 형광체의 발광 특성)

  • Lee, Ho Min;Jung, Kyeong Youl;Jung, Ha-Kyun;Lee, Jong Heun
    • Korean Chemical Engineering Research
    • /
    • v.44 no.3
    • /
    • pp.284-288
    • /
    • 2006
  • $(Ca,Sr)_{2-y}MgSi_2O_7:Eu^{2+}{_y}$ (CMS) phosphor particles were prepared by using a spray pyrolysis process. The luminescent property was optimized by changing the content of Eu and the post-treatment temperature. The luminescence characteristics were also monitored with changing the ratio of Ca to Sr. The pure tetragonal $Ca_2MgSi_2O_7$ or $Sr_2MgSi_2O_7$ particles were obtained when the post-treatment temperature was over $1,000^{\circ}C$. The highest emission intensity of CMS particles were achieved when the concentration (y) of Eu and the treatment temperature were 0.05 and $1,250^{\circ}C$,respectively. The emission wavelength $({\lambda}_{max})$ of ${(Ca_{1-x},Sr_x)}_{1.95}MgSi_2O_7:{Eu^{2+}}_{0.05}$ was gradually shifted from 524 nm to 456 nm with increasing the content of Sr due to the reduction of crystal field strength. The emission intensity and its width of $Sr_2MgSi_2O_7:Eu$ was greatly enhanced by substituting Ca of less than 10 mol% for Sr without any significant peak shift. The morphology of as-prepared particles was spherical, but changed to irregular-shaped one after the post treatment at the temperature range from 900 at $1,300^{\circ}C$.

Quilitative certificational plan of heshouwu (하수오(何首烏)의 품질인증(品質認證) 방안(方案))

  • Shin, Mi-Kyung;Roh, Seong-Soo;Kil, Ki-Jeong;Seo, Bu-il;Seo, Young-Bae
    • Journal of Haehwa Medicine
    • /
    • v.13 no.2
    • /
    • pp.205-212
    • /
    • 2004
  • Now many sustitution and false articles is used in korea instead of heshouwu. To use heshouwu correctly, we will make a quilitative certificational plan of heshouwu to investigate all of lieraturea, records and documents. And we could reach conclusions as folloews. 1) Source of plant Heshouwu is a root tuber of a perennial herb Polygonum multiflorum Thunberg(Family : Polygonaceae). 2) Harvest After planting 3-5 yaers, harvesting in an autumn, washin clean the mud, a big heshouwu cut off a half or section, dry in sunny place or at a little fire. When harvesting, we harvest only a big thing, a small thing transfer a field, after culturing of 1-2 years, harvest at big roots. Harvesting is done usually in an autumn after 3 years. When collecting a seed, we must harvest a heshouwu the next year. 3) Process We must process heshouwu at the decoction of black beans, heshouwu suck in the decoction of black beans, heat with steam in an iron pot. Black beans is used every 100 kg of heshouwu. 4) Quility (1) Funstional standards It is good that weight is heavy and outer skin is yellow-brown, section surface is light red color, powdery and has a figure such as clouds in section. (2) Physicochemical standards Heshouwu expesses a various chang of components in process of working. We think that it need to add a standard of detection about 2,3,5,4'-tetrahrdroxystilbene-2-O-${\beta}$ -D-glucoside in a current authentic document which is a water-soluble component of heshouwu. It must that Dry on loss is less than 14.0%, content of ash is less than 5.0%, Content of acid-nonsoluble ash is less than 1.5%, Content of extract is more than 17.0%. A fixed quantity of 2,3,5,4'-tetrahrdroxystilbene-2-O-${\beta}$ -D-glucoside is more than 1.0%. Contens of heavy metal has to detect less than 30 ppm and there is no reminding agriculural medince.

  • PDF

Proposal and Verification of Image Sensor Non-uniformity Correction Algorithm (영상센서 픽셀 불균일 보정 알고리즘 개발 및 시험)

  • Kim, Young-Sun;Kong, Jong-Pil;Heo, Haeng-Pal;Park, Jong-Euk
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.3
    • /
    • pp.29-33
    • /
    • 2007
  • All pixels of image sensor do not react uniformly even if the light of same radiance enters into the camera. This non-uniformity comes from the sensor pixel non-uniformity and non-uniformity induced by the changing transmission of the telescope over the field. The first contribution to the non-uniformity has high spatial frequency nature and has an influence on the result and quality of the data compression. The second source of non-uniformity has low frequency nature and has no influence of the compression result. As the contribution resulting from the sensor PRNU(Photo Response Non-Uniformity) is corrected inside the camera electronics, the effect of the remaining non-uniformity to the compression result will be negligible. The non-uniformity correction result shall have big difference according to the sensor modeling and the calculation method to get correction coefficient. Usually, the sensor can be modeled with one dimensional coefficients which are a gain and a offset for each pixel. Only two measurements are necessary theoretically to get coefficients. However, these are not the optimized value over the whole illumination level. This paper proposes the algorithm to calculate the optimized non-uniformity correction coefficients over whole illumination radiance. The proposed algorithm uses several measurements and the least square method to get the optimum coefficients. The proposed algorithm is verified using the own camera electronics including sensor, electrical test equipment and optical test equipment such as the integrating sphere.

Extragalactic Sciences from SPICA/FPC-S

  • Jeong, Woong-Seob;Matsumoto, Toshio;Im, Myungshin;Lee, Hyung Mok;Lee, Jeong-Eun;Tsumura, Kohji;Tanaka, Masayuki;Shimonishi, Takashi;Lee, Dae-Hee;Pyo, Jeonghyun;Park, Sung-Joon;Moon, Bongkon;Park, Kwijong;Park, Youngsik;Han, Wonyong;Nam, Ukwon
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.38 no.1
    • /
    • pp.36.2-36.2
    • /
    • 2013
  • The SPICA (SPace Infrared Telescope for Cosmology & Astrophysics) project is a next-generation infrared space telescope optimized for mid- and far-infrared observation with a cryogenically cooled 3m-class telescope. The focal plane instruments onboard SPICA will enable us to resolve many astronomical key issues from the formation and evolution of galaxies to the planetary formation. The FPC-S (Focal Plane Camera - Sciecne) is a near-infrared instrument proposed by Korea as an international collaboration. Owing to the capability of both low-resolution imaging spectroscopy and wide-band imaging with a field of view of $5^{\prime}{\times}5^{\prime}$, it has large throughput as well as high sensitivity for diffuse light compared with JWST. In order to strengthen advantages of the FPC-S, we propose the studies of probing population III stars by the measurement of cosmic near-infrared background radiation and the star formation history at high redshift by the discoveries of active star-forming galaxies. In addition to the major scientific targets, to survey large area opens a new parameter space to investigate the deep Universe. The good survey capability in the parallel imaging mode allows us to study the rare, bright objects such as quasars, bright star-forming galaxies in the early Universe as a way to understand the formation of the first objects in the Universe, and ultra-cool brown dwarfs. Observations in the warm mission will give us a unique chance to detect high-z supernovae, ices in young stellar objects (YSOs) even with low mass, the $3.3{\mu}$ feature of shocked circumstance in supernova remnants. Here, we report the current status of SPICA/FPC project and its extragalactic sciences.

  • PDF

A study of Tumor Angiogenesis in Human Lung Cancer by Immunohistochemical Stain (Human Lung Cancer에서 면역세포화학적 방법을 이용한 Tumor Angiogenesis에 관한 연구)

  • Cheon, Seon Hee;Kim, Sung Sook;Rha, Sun Young;Chung, Hyun Cheol
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.6
    • /
    • pp.894-902
    • /
    • 1996
  • Background : Tumor angiogenesis is the growth of new vessels toward and within tumor. It has been demonstrated that the growth of tumor beyond a certain size requires angiogenesis and it is closely involved in tumor progression and metastasis. The finding that intensity of neovascularization correlates independently with metastasis may lead to identification of patients in whom radical surgery should be supplemented by systemic treatment. Method : We have collected paraffin blocks of bronchoscopic biopsy of patients with non-small cell lung cancer. We highlighted the vessel by staining endothelial cell with JC70 monoclonal antibody(to CD31) immunohistochemically and counted microvessels under 200 X field using light microscopy. Results : 1) The mean microvessel count was $32.7{\pm}20.8$ (9-96) in total 29 cases. 2) There were no correlations between microvessel counts and pathologic cell type, T staging, node melastasis(N) and hematogenous metastasis(M) (p>0.05). 3) The median follow-up duration was 15 months(2-46) and there was no correlation between the microvessel counts and survival rate of lung cancer patients (p>0.05). Conclusion : Tumor angiogenesis seems to be an important prognostic factor suggesting the probability of metastasis. But the microvessel count in the bronchoscopic biopsy specimen was inadequate and very limited. There has been no data about angiogenesis of lung cancer in korea yet So the study of tumor angiogenesis using resected lung tumor specimen would be demanded.

  • PDF

Ordered Macropores Prepared in p-Type Silicon (P-형 실리콘에 형성된 정렬된 매크로 공극)

  • Kim, Jae-Hyun;Kim, Gang-Phil;Ryu, Hong-Keun;Suh, Hong-Suk;Lee, Jung-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.241-241
    • /
    • 2008
  • Macrofore formation in silicon and other semiconductors using electrochemical etching processes has been, in the last years, a subject of great attention of both theory and practice. Its first reason of concern is new areas of macropore silicone applications arising from microelectromechanical systems processing (MEMS), membrane techniques, solar cells, sensors, photonic crystals, and new technologies like a silicon-on-nothing (SON) technology. Its formation mechanism with a rich variety of controllable microstructures and their many potential applications have been studied extensively recently. Porous silicon is formed by anodic etching of crystalline silicon in hydrofluoric acid. During the etching process holes are required to enable the dissolution of the silicon anode. For p-type silicon, holes are the majority charge carriers, therefore porous silicon can be formed under the action of a positive bias on the silicon anode. For n-type silicon, holes to dissolve silicon is supplied by illuminating n-type silicon with above-band-gap light which allows sufficient generation of holes. To make a desired three-dimensional nano- or micro-structures, pre-structuring the masked surface in KOH solution to form a periodic array of etch pits before electrochemical etching. Due to enhanced electric field, the holes are efficiently collected at the pore tips for etching. The depletion of holes in the space charge region prevents silicon dissolution at the sidewalls, enabling anisotropic etching for the trenches. This is correct theoretical explanation for n-type Si etching. However, there are a few experimental repors in p-type silicon, while a number of theoretical models have been worked out to explain experimental dependence observed. To perform ordered macrofore formaion for p-type silicon, various kinds of mask patterns to make initial KOH etch pits were used. In order to understand the roles played by the kinds of etching solution in the formation of pillar arrays, we have undertaken a systematic study of the solvent effects in mixtures of HF, N-dimethylformamide (DMF), iso-propanol, and mixtures of HF with water on the macrofore structure formation on monocrystalline p-type silicon with a resistivity varying between 10 ~ 0.01 $\Omega$ cm. The etching solution including the iso-propanol produced a best three dimensional pillar structures. The experimental results are discussed on the base of Lehmann's comprehensive model based on SCR width.

  • PDF

A Policy Community Model for 'Creative Cultural Contents Tourism' Infrastructure : A Case Study on Seongnam City ('창의적 문화콘텐츠관광' 기반조성을 위한 정책공동체 모형 -성남시 사례를 중심으로-)

  • Kim, Hyeong-Soo
    • Journal of Digital Convergence
    • /
    • v.11 no.11
    • /
    • pp.177-190
    • /
    • 2013
  • Recently, our society is seeing cultural value in a new light, perceiving it as an element that creates new values added. Reflecting this trend, the local governments in various levels focus on reviving the regional economies by enhancing cultural competencies and developing the culture and tourism industries. This research is conducted to perform the policy project 'administrative support plans to make Seongnam a hub of international culture and tourism,' which was proposed as part of the urban renewal strategy of the city. This study proposes the establishment of 'policy communities' to build the infrastructure for 'creative cultural content tourism' as a plan to accomplish the policy goal pursued by Seongnam. The focuses include what the policy communities are, how they work, and what the local government has to do with them for a successful implementation of proposed policies, by theoretically examining the composition variables of policy communities. In particular, the study concentrates on how to reconstruct the infrastructure for the culture content technology (CT) in the IT-based city and to transform itself into a city of "creative cultural content tourism". If the policy communities are formed under the proposed model in this paper, it is expected that they will become the viable alternatives in the field.

Development of New Prototype of Mechanical Quality Assurance for Clinical Linear Accelerator (의료용 선형가속기의 기계적 점검을 위한 새로운 정도관리 프로토콜의 개발)

  • 윤형근;신교철;김기환;오영기;김진기;정동혁;김정기;조문준;박인규
    • Progress in Medical Physics
    • /
    • v.13 no.3
    • /
    • pp.109-113
    • /
    • 2002
  • In recent years, the radiotherapy equipment has become much more sophisticated, and with the complication comes an increased set of quality assurance (QA) responsibilities. Today's computer controlled linear accelerator requiring QA of not only the radiation integrity, but also the mechanical accuracy of the linear accelerator. The existing QA sheets are adequate for acceptance testing and commissioning but those sheets are somewhat descriptive form for routine QA. establishing the QA sheets for a facility are more efficient if the sheets could estimate the long-term stability for the result of QA. We are going to develope new prototype of mechanical QA sheet to visualize and to verify long-term stability of mechanical QA for clinical linear accelerator. The items included in mechanical QA sheet were 1) gantry rotation, 2) collimator rotation, 3) couch rotation, 4) optical distance indicator (ODI), and 5) laser alignment. We compared new prototype sheet with conventional sheet for several hospitals in Korea for those items. The QA acceptance criteria in this study mainly followed published recommendations. The contents of test for mechanical QA are the following. Confirm that the digital and/or mechanical gantry angle readouts are correct. Verify that digital and/or mechanical readouts of collimator angle agree with the true angle, as determined with the protractor. Measure the light field using a graph paper and compare with the digital readouts. Confirm digital readout accuracy. Verify that the sagittal laser, the left and right lasers, and the ceiling laser intersect at the isocenter. In the design of new QA sheet, we emphasized the representation of the long-term stability of mechanical QA by using Excel program. By using the new prototype QA sheet, we simplified and visualized the mechanical QA process, and could estimate the long-term stability of mechanical error of linear accelerator.

  • PDF

The design and FPGA implementation of a general-purpose LDI controller for the portable small-medium sized TFT-LCD (중소형 TFT-LCD용 범용 LDI 제어기의 설계 및 FPGA 구현)

  • Lee, Si-Hyun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.12 no.4
    • /
    • pp.249-256
    • /
    • 2007
  • AIn this paper, a new desist of LDI controller IC for general purpose is proposed for driving the LDI(LCD Driver Interface) controller in $4{\sim}9$ inches sized portable small-medium TFT-LCD(Thin Film Transistor addressed -Liquid Crystal Display) panel module. The designed LDI controller was verified on the FPGA(Reld Programmable Gate Array) test board, and was made the interactive operation with the commercial TFT-LCD panel successfully. The purpose of design is that it is standardized the LDI controller's operation by one LDI controller for driving all TFT-LCD panel without classifying the panel vendor, and size. The main advantage for new general-purpose LDI controller is the usage for the desist of all panel's SoG(System on a Glass) module because of the design for the standard operation. And in the previous method, it used each LDI controller for every LCD vendor, and panel size, but because a new one can drive all portable small-medium sized panel, it results in reduction of LDI controller supply price, and manufacturing cost of AV(Audio Video) board and panel. In the near future, the development of SoG IC(Integrated Circuit) for manufacturing more excellent functional TFT-LCD panel module is necessary. As a result of this research, the TFT-LCD panel can make more small size, and light weight, and it results in an upturn of domestic company's share in the world market. With the suggested theory in this paper, it expects to be made use of a basic data for developing and manufacturing for the SoG chip of TFT-LCD panel module.

  • PDF