• Title/Summary/Keyword: light curing

Search Result 464, Processing Time 0.028 seconds

Effects of contamination by either blood or a hemostatic agent on the shear bond strength of orthodontic buttons

  • Gungor, Ahmet Yalcin;Alkis, Huseyin;Turkkahraman, Hakan
    • The korean journal of orthodontics
    • /
    • v.43 no.2
    • /
    • pp.96-100
    • /
    • 2013
  • Objective: To evaluate the effects of contamination by either blood or a hemostatic agent on the shear bond strength (SBS) of orthodontic buttons. Methods: We used 45 freshly extracted, non-carious, impacted third molars that were divided into 3 groups of 15. Each tooth was etched with 37% phosphoric acid gel for 30 s. Human blood or the blood stopper agent was applied to the tooth surface in groups I and II, respectively. Group III teeth were untreated (controls). Orthodontic buttons were bonded to the teeth using light-curing composite resin. After bonding, the SBS of the button was determined using a Universal testing machine. Any adhesive remaining after debonding was assessed and scored according to the modified adhesive remnant index (ARI). ANOVA with post-hoc Tukey's test was used to determine significant differences in SBS and Fisher's exact test, to determine significant differences in ARI scores among groups. Results: ANOVA indicated a significant difference between groups (p < 0.001). The highest SBS values were measured in group III ($10.73{\pm}0.96$ MPa). The SBS values for teeth in groups I and II were significantly lower than that of group III (p < 0.001). The lowest SBS values were observed in group I teeth ($4.17{\pm}1.11$ MPa) (p < 0.001). Conclusions: Contamination of tooth surfaces with either blood or hemostatic agent significantly decreased the SBS of orthodontic buttons. When the contamination risk is high, it is recommended to use the blood stopper agent when bonding orthodontic buttons on impacted teeth.

Korean Red Ginseng enhances cardiac hemodynamics on doxorubicin-induced toxicity in rats

  • Jang, Young-Jin;Lee, Dongbin;Hossain, Mohammad Amjad;Aravinthan, Adithan;Kang, Chang-Won;Kim, Nam Soo;Kim, Jong-Hoon
    • Journal of Ginseng Research
    • /
    • v.44 no.3
    • /
    • pp.483-489
    • /
    • 2020
  • Background: Korean Red Ginseng (KRG) has been known to possess many ginsenosides. These ginsenosides are used for curing cardiovascular problems. The present study show the protective potential of KRG against doxorubicin (DOX)-induced myocardial dysfunction, by assessing electrocardiographic, hemodynamic, and biochemical parameters and histopathological findings. Methods: Animals were fed a standard chow and adjusted to their environment for 3 days before the experiments. Next, the rats were equally divided into five groups (n = 9, each group). The animals were administered with KRG (250 and 500 mg/kg) for 10 days and injected with DOX (20 mg/kg, subcutaneously, twice at a 24-h interval) on the 8th and 9th day. Electrocardiography and echocardiography were performed to study hemodynamics. Plasma levels of superoxide dismutase, catalase, glutathione peroxidase, and malondialdehyde were measured. In addition, the dose of troponin I and activity of myeloperoxidase in serum and cardiac tissue were analyzed, and the histopathological findings were evaluated using light microscopy. Results: Administration of KRG at a dose of 250 and 500 mg/kg recovered electrocardiographic changes, ejection fraction, fractional shortening, left ventricular systolic pressure, the maximal rate of change in left ventricle contraction (-dP/dtmax), and left ventricle relaxation (-dP/dtmax). In addition, KRG treatment significantly normalized the oxidative stress markers in plasma, dose dependently. In addition, the values of troponin I and myeloperoxidase were ameliorated by KRG treatment, dose dependently. And, KRG treatment showed better histopathological findings when compared with the DOX control group. Conclusion: These mean that KRG mitigates myocardial damage by modulating the hemodynamics, histopathological abnormality, and oxidative stress related to DOX-induced cardiomyopathy in rats. The results of the present study show protective effects of KRG on cardiac toxicity.

PHYSICAL PROPERTIES OF RELINING DENTURE BASE RESINS WITH DIFFERENT POLYMERIZING METHODS (중합방법이 다른 의치상 이장용레진의 물리적 특성)

  • Cho Suck-Kyu;Song Kwang-Yeob;Yoon Soo-Yun;Kim Mun-Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.4
    • /
    • pp.386-395
    • /
    • 2002
  • This study would like to measure and compare water sorption and solubility of acrylic resins, with 3 different polymerizing methods, and tensile strength between denture base resin and relining rosins. For this experiment, 3 different acrylic resins were used; heat polymerizing resin: Vertex (Dentmex, Zeist, Holland), autopolymerizing resin: Tokuso Rebase (Tokuyama Corp, Tokyo, Japan), and light curing resin: Mild Rebaron LC(GC Corp, Tokyo, Japan) The results were as follows ; 1. Tokuso Rebase showed the lowest water sorption. followed by Mild Rebaron LC and Vertex. Among resins, there were some signigicant differences (P<0.05). 2. Vertex showed the lowest solubility, followed by Mild Rebaron LC and Tokuso Rcbase. Among resins, there were some signigicant differences (P<0.05). 3. Intact Vertex showed the highest tensile strength, and Mild Rebaron LC had a more tensile strength than Tokuso Rebase. Between Vertex and the other resins, there were some signigicant differences (P<0.05) However, between Mild Rebaron LC and Tokuso Rebase, there was no statistical difference (P>0.05). About 50% of Rebaron LC showed cohesive fracture. 4. Tensile strength has more decreased after thermocycling than before, but there was no statistical difference (P>0.05).

The effect of IDS (immediate dentin sealing) on dentin bond strength under various thermocycling periods

  • Lee, sungbok Richard;Lee, Sang-Min;Park, Su-Jung;Lee, Suk-Won;Lee, Do Yun;Im, Byung-Jin;Ahn, Su-Jin
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.3
    • /
    • pp.224-232
    • /
    • 2015
  • PURPOSE. The purpose of this study was to find out the effect of immediate dentin sealing (IDS) on bond strength of ceramic restoration under various thermocycling periods with DBA (dentin bonding agent system). MATERIALS AND METHODS. Fifty freshly extracted human mandibular third molars were divided into 5 groups (1 control and 4 experimental groups) of 10 teeth. We removed enamel layer of sound teeth and embedded them which will proceed to be IDS, using All Bond II. A thermocycling was applied to experimental groups for 1, 2, 7, 14 days respectively and was not applied to control group. IPS Empress II for ceramic was acid-etched with ceramic etchant (9.5% HF) and silane was applied. Each ceramic disc was bonded to specimens with Duo-link, dual curable resin cement by means of light curing for 100 seconds. After the cementation procedures, shear bond strength measurement and SEM analysis of the fractured surface were done. The data were analyzed with a one-way ANOVA and Tukey multiple comparison test (${\alpha}$=.05). RESULTS. There were no statistically significant differences between 4 experimental groups and control group, however the mean value started to decrease in group 7d, and group 14d showed the lowest mean bond strength in all groups. Also, group 7d and 14d showed distinct exposed dentin and collapsed hybrid layer was observed in SEM analysis. CONCLUSION. In the present study, it can be concluded that ceramic restorations like a laminate veneer restoration should be bonded using resin cement within one week after IDS procedure.

Retentive Force of Dental Impression Tray According to Retention form (유지형태에 따른 치과 인상용 트레이의 유지력에 관한 연구)

  • Choi, Min-Ho;Shin, Dong-Kuk;Kim, Min-Jeong;Oh, Sang-Chun;Dong, Jin-Keun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.20 no.1
    • /
    • pp.43-50
    • /
    • 2004
  • This study was performed to measure the retentive force of dental impression tray according to retention form. The 9 resin beams($30{\times}60{\times}2.5mm$) were made of visible light-curing tray resin according to the surface texture, the size of hole and the number of rim. The resin block was fabricated in width 50mm, length 30mm, heght 40mm to maintain an even hydrocolloid impression material. The retentive force between the resin beam and hydrocolloid impression material was measured by Universal Testing Machine(Zwick Z020, Zwick Co., Germany). The results obtained in this study were as follows : 1. The retentive force of the resin beam with bilateral 4 rims, 2mm holes(9group) was highest(9.18kg), and the polishing resin beam(2group) was worst(4.85kg). 2. There was no significant difference between the polished the resin beam(2group) and the contrast resin beam(1group). 3. The retentive force of the rimmed resin beam was higher than the perforated resin beam. 4. The retentive force of the 2mm perforated resin beam(4group) was higher than the 3mm perforated resin beam(3group). 5. As increasing the number of rim increased the retentive force.

Studies on the Development of Corrugated Board and Investigation of Optimum Corrugating Adhesive for Archival Quality Container (Part 1) (기록물 보존상자용 골판지 개발 및 접착제 탐색에 관한 연구 (제1보))

  • Park, Ji-Hyun;Kim, Hyoung-Jin;Lee, Tai-Ju;Seo, Young-Bum
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.41 no.4
    • /
    • pp.73-81
    • /
    • 2009
  • The document archives like official documents, books, maps and historic paper artifacts are primarily based on the organic cellulosic materials. As the passage of time, these organic cellulosic materials are slowly deteriorated by various aging factors, like light, polluted air and biological fungi. Many researchers have been carried out the examination method of deteriorating origins, the mechanism of aging hysteresis, and the preserving method of archival materials. One of the most simple and easiest ways for conservation of organic archival documents is the proper storage under environmental control. Corrugated board for archival quality container has been developed and already used in advanced country, like Japan, USA, German, UK and Europe. In case of Korea, corrugated board for archival quality container has been used a decade ago, but totally imported. This study was tried to develop the corrugated board for archival quality container. Liner and corrugated medium were specially produced and finally manufactured to E flute corrugated board. The physical and strength properties of permanent base paper and corrugated board were evaluated, and compared with imported corrugated board. 4 kinds of corrugating adhesives were considered various in order to investigate optimum adhesive for flute development between liner and corrugating medium, and evaluate adhesion strength under conditions of storage and curing temperatures.

A Study on the origin and the literature of eyelid-acupuncture therapy as a folk remedy in Korea and its clinical Usage (한국 눈침요법의 문헌 근거와 전승 현황 연구)

  • Jeon, Jong-Wook;Ha, Seung-Rok;Lee, Jeong-Hwa;Lim, Bo-Kyung;Choi, Sun-Mi
    • The Journal of Korean Medical History
    • /
    • v.24 no.2
    • /
    • pp.69-76
    • /
    • 2011
  • This study focuses on the origin and the literature of eyelid-acupuncture, nunchim therapy in Korea and its present clinical usage in modern Korea. The therapy is called nunchim at local area of Korea and has been transmitted as folk remedy because its real practice has been fallen into oblivion in the regular medical institution in modern Korea. On the contrast, some old women called nunchim-halmae, still know its practice and give medical therapy in a certain irregular way. While many kinds of eye clinics are prevalent in Korea, some patients with chronic eye diseases still go to get the nunchim therapy from nunchim-halmae. Moreover some oriental medical doctors have learned the therapy from nunchim-halmae and performed that medical service in their clinics in spite of absence of medical insurance coverage. Nunchim has unique historic origin and transmission linage in Korea, which was shed light on by this research. We present concise structure of the essence of nunchim therapy and 80 year old woman case of dramatic eye curing with the therapy.

Design of a Bar-type TIR Lens Having a Freeform Surface for Forming a Line Beam Using an LED Light Source (LED 광원 사용 시 line beam 형성을 위한 자유 곡면 bar type의 TIR lens 설계)

  • Seo, Jin-Hee;Lee, Jeong-Su;Kim, Seo-Young;Jeong, You-Jin;Park, Hye-Jin;Nam, Deuk-Young;Jung, Mee-Suk
    • Korean Journal of Optics and Photonics
    • /
    • v.28 no.6
    • /
    • pp.295-303
    • /
    • 2017
  • In this paper, we have studied a method of forming a line beam using a UV LED. The existing linear-type UV LED curing optical system is composed of several cylindrical lenses, but problems such as optical system alignment, enlargement of the module, efficiency, etc. may arise in the future. As an alternative to these problems, a bar-type TIR lens having a freeform surface only in the y-axis direction is designed, to verify that it shows advantages in maximum illuminance, uniformity of illuminance, and flux efficiency.

Bonding strength of resin and porcelain depending on the effects of zirconia surface etching (지르코니아 표면 에칭처리 효과에 따른 레진 및 도재의 결합강도)

  • Park, Young-Dae;Han, Sok-Yoon
    • Journal of Technologic Dentistry
    • /
    • v.39 no.4
    • /
    • pp.243-251
    • /
    • 2017
  • Purpose: The purpose of this study was to investigate the effects of etching by monitoring the etched surfaces and the shear bonding strength of resin and porcelain with etched zirconia. Methods: The CAD/CAM was used to produce 24 zirconia blocks in groups of six. The zirconia specimen surfaces were sandblasted, and they were then divided into 12 specimens with surface etching and 12 specimens without etching for the control group. 12 specimens of composite resin were bonded using a curing light, and 12 specimens of porcelain underwent vita porcelain build-up sintering and the shear bonding strength was measured using a universal testing system. The SEM photographs were taken in order to observe any differences in the surfaces before and after etching, and they were magnified by a factor of 8 in order to observe fractured surface types. Results: The results of the shear bonding strength measurements are as follows: For the composite resin tests, between zirconia and resin, the shear bonding strength of the control group (NZR) without surface etching was 4.68 Mpa and the experimental group (EZC) with surface etching was 9.65 Mpa, which is significantly higher. The crystal structure of the zirconia was confirmed to be different in observations of the surfaces before and after etching. Conclusion : In comparing the shear bonding strength of zirconia and composite resin, the effects of etching were found to be significant. The effects of surface etching were also observed in fractured surfaces between zirconia and porcelain. This is expected to be applicable to various prosthetics as surface etching on zirconia is used in clinics.

Optimal Design of Long-fiber Composite Cover Plate with Ribs (리브를 가진 장섬유 복합재료 커버 플레이트의 최적설계)

  • Han, Min-Gu;Bae, Ji-Hun;Lee, Sung-Woo;Chang, Seung-Hwan
    • Composites Research
    • /
    • v.30 no.1
    • /
    • pp.65-70
    • /
    • 2017
  • Carbon fiber reinforced composites have light weight and high mechanical properties. These materials are only applicable in limited shape structure cause by complex curing process and low drapability. To solve this problem, Long Fiber Prepreg Sheet (LFPS) has been proposed. In this research, electric device cover plate was selected and designed by using LFPS. Before the design process, we analyzed the target structure to which the rib structures were applied. And 8-inch tablet PC product was selected. For FE analysis, simple loading and boundary conditions were applied. Stiffness of rib structure was investigated according to the rib pattern and shape changes. Rib pattern and shape were selected based on fixed volume condition analysis results. And uneven rib width model was selected for the best case whose deflection was reduced 6~10% than uniform rib model.