• Title/Summary/Keyword: light and lens

Search Result 551, Processing Time 0.03 seconds

Early Growth and Characteristic of Histological Eye Development in Post Parturition Dark banded Rockfish, Sebastes inermis (볼락, Sebastes inermis 산출 후 초기 성장 및 눈의 조직학적 발달 특성)

  • Park, In-Seok;Park, Hye-Jung;Gil, Hyun-Woo;Goo, In-Bon
    • Development and Reproduction
    • /
    • v.16 no.2
    • /
    • pp.101-106
    • /
    • 2012
  • Importance of behavior factors or environmental factors in visual organization and visual function of fish is treated with great care in visual ecology, and there is no study about initial ocular growth and development on the dark banded rockfish, Sebastes inermis. Thus, this study was performed. The total length, head length, head depth, eye diameter and lens diameter of the dark banded rockfish showed positive allometric relationship between parturition stage and 60 days post-parturition (dpp). The increase in total length relative to head length and head depth, head length growth relative to eye diameter and lens diameter, and head depth growth relative to eye and lens diameter were nearly isometric. The eyes were formed completely at parturtion stage. At this age, the eye has an optic nerve fiber layer, a ganglion cell layer, an inner plexiform layer, an inner nuclear layer, an outer plexiform layer, an outer nuclear layer, an outer limiting membrane, a rod and cone layer and an epithelial layer. Thickness of retina at 60 dpp was higher than that of at parturition stage. During this experiment, the proportion of the rod and cone layer, outer nuclear layer, and optic nerve fiber layer of retina were significantly increased, while the proportion of the outer plexiform layer, inner nuclear layer and ganglion cell layer of retina were significantly decreased (P<0.05). The essential demands that must be met by the retina in this species pertain to light sensitivity and spatial resolution.

The comparative of Naringin and Chitosan using Natural preservation agents by LM and TEM (천연보존제 나린진과 키토산의 비교....LM & TEM적 소견)

  • Kim, In-Suk;Yoo, Geun-Chang;Chae, Soo-Chul;Lee, Chong-Bin;Jeon, Chang-Jin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.4
    • /
    • pp.283-292
    • /
    • 2005
  • This study investigated the effects of naringin, and chitosan in rabbits' corneas. Naringin, a glycone of naringenin, is a widely distributed bioflavonoid in the grapefruit and citrus peel, and it has already been reported as an antioxidant, antimicrobial, and anticancer agent. It has been used as a food preservatives and cosmetics. One of the natural preservatives, chitosan has also used in food preservatives, health drinks, and teas. Chitosan is distributed in the epithelium of crustacea, insects, and fungi. Naringin and chitosan have no harmful effects of cytotoxicity in the human body and they are recognized as an antibacterial for various forms of bacteria. The purpose of this study is to search for the ideal percentage of natural products to substitute the chemical preservatives occuring within the cornea and conjunctiva cytotoxicity and inflammations as wearing on soft contact lens. The present study compared the morphology of corneal epithelium and endothelium observed by light microscopy (LM) and transmission electron microscopy (TEM). In vivo methods, We investigated the effects of natural preservatives on soft contact lens. We inserted 3-4 drops of the naringin and chitosan, directly on rabbits' corneas 4 times per a day during one week. After enucleation of cornea, morphorgical damages of the epithelium and endothelium were observed by LM and TEM. In view of ultrastructure, chitosan caused siginficant damage on the epithelium and endothelium of cornea. The damage of cells was higher in chitosan treated cornea than 0.01, 0.1, and 1% of naringin. The 1% of naringin also expressed cell damage seriously. The results suggest that the most important thing is to use the reasonable percentage of preservatives for contact lens solutions.

  • PDF

Performance Prediction for Plenoptic Microscopy Under Numerical Aperture Unmatching Conditions (수치 구경 불일치 플렌옵틱 현미경 성능 예측 방안 연구)

  • Ha Neul Yeon;Chan Lee;Seok Gi Han;Jun Ho Lee
    • Korean Journal of Optics and Photonics
    • /
    • v.35 no.1
    • /
    • pp.9-17
    • /
    • 2024
  • A plenoptic optical system for microscopy comprises an objective lens, tube lens, microlens array (MLA), and an image sensor. Numerical aperture (NA) matching between the tube lens and MLA is used for optimal performance. This paper extends performance predictions from NA matching to unmatching cases and introduces a computational technique for plenoptic configurations using optical analysis software. Validation by fabricating and experimenting with two sample systems at 10× and 20× magnifications resulted in predicted spatial resolutions of 12.5 ㎛ and 6.2 ㎛ and depth of field (DOF) values of 530 ㎛ and 88 ㎛, respectively. The simulation showed resolutions of 11.5 ㎛ and 5.8 ㎛, with DOF values of 510 ㎛ and 70 ㎛, while experiments confirmed predictions with resolutions of 11.1 ㎛ and 5.8 ㎛ and DOF values of 470 ㎛ and 70 ㎛. Both formula-based prediction and simulations yielded similar results to experiments that were suitable for system design. However, regarding DOF values, simulations were closer to experimental values in accuracy, recommending reliance on simulation-based predictions before fabrication.

Preparation and Characterization of Silicone Hydrogel Lens Containing Poly(ethylene glycol) (PEG를 포함한 실리콘 수화젤 렌즈의 제조 및 특성)

  • Jang, Ha-Na;Chung, Youn-Bok;Kim, Sung-Soo
    • Polymer(Korea)
    • /
    • v.33 no.2
    • /
    • pp.169-174
    • /
    • 2009
  • Silicone hydrogels incorporated with poly(ethylene glycol)(PEG) were prepared and characterized to evaluate the effects of PEG on contact lenses. The silicone hydrogels were copolymerized with methacryloxypropyl tris(trimethylsiloxy) silane (TRIS), methyl methacrylate (MMA), N,N-dimethyl acrylamide (DMA) and PEG-containing monomers such as poly(ethylene glycol) methyl ether methacrylate (PEG- MEM). The silicone hydrogels were characterized using Fourier transform infrared spectroscopy (FT-IR), electron spectroscopy of chemical analysis (ESCA), and scanning electron microscopy (SEM). Water absorbance, water contact angle and light transmittance of the silicone hydrogels were evaluated. The experiments of protein adsorption were also carried out to evaluate the protein adsorption in tears. The peak intensity of C-O bond was increased by the incorporation of PEG-containing monomers and thus PEG incorporation into silicone hydrogels could be confirmed. Phase separation was not shown by the SEM observation of the cross-section of silicone hydrogels. Water absorbancy was increased, while water contact angle and light transmittance were decreased with increasing incorporation of the PEG-containing monomers. The absorption of proteins in tears, albumin, lysozyme and $\gamma$-globulin, on the surface of silicone hydrogels was decreased with increasing incorporation of the PEG-containing monomers.

Smart Headlamp Optics Design with Multi-array LEDs (멀티 어레이 엘이디를 이용한 지능형 전조등 광학 설계)

  • Yu, Jin Hee;Ro, Suk Ju;Lee, Jun Ho;Hwang, Chang Kook;Go, Dong Jin
    • Korean Journal of Optics and Photonics
    • /
    • v.24 no.5
    • /
    • pp.231-236
    • /
    • 2013
  • We investigated the optical design of a smart headlamp capable of producing various beam patterns through only on/off modulation of light sources. This was implemented by forming a continuous matrix of beams from discontinuous beam patterns by means of a multi-array LED optical system. As one such optical system, the multi-array LED system is a convenient and economical device for implementing beam patterns with the simple on/off modulation of the light sources. A single optical assembly module can be made by combining a multiple-LED array, optical system module, and electronic control with no need for any additional mechanical components. The present optical system was designed to include a secondary lens and a projection lens mounted at the front of each LED in the array to realize accurate lighting patterns as well as the required luminosity at a distance of 25 m in the forward direction. Finally, we identified and analyzed the patterns implemented by the designed optical system that produced satisfactory performance of high beams and adaptive driving beams (ADB).

Development of Portable Laryngeal Stroboscope (휴대형 후두 스트로보스콥의 개발)

  • Lee, Jae-Woo;Kwon, Soon-Bok;Lee, Byung-Joo;Lee, Jin-Choon;Goh, Eui-Kyung;Chon, Kyong-Myong;Wang, Soo-Geun;Ro, Jung-Hoon
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.17 no.1
    • /
    • pp.28-37
    • /
    • 2006
  • Purpose: Evaluation of vocal cord vibration is very important in cases of voice disorders. There are several equipments for examining the vocal fold vibration such as laryngeal stroboscope, ultra high-speed digital imaging system, and videokymograph. Among these, laryngeal stroboscope is the most popular equipment because of easy to examine the laryngeal pathology. However, current laryngo-stroboscopes are too bulky to move and relatively expensive. The purpose of this research is to develope a portable laryngeal stroboscope of equivalent performance with the current equipments. Methods and Materials: Recently developed high luminescent white LEDs(light emitting diodes) are placed at the head of the endoscope as light sources for the CCD image sensor which is also placed at the head with imaging lens. This arrangement eliminates the bulky light source like expensive halogen or xenon lamps as well as the optical light guiding cables. The LEDs are controlled to flash in phase with the voice frequency of the examinee. The CCD captures these strobo images and converts them into video signals for examinations. Results: There was no functional differences between preexisting stroboscope and the newly developed stroboscope of this study. LED light sources and microprocessor based control circuits of the stroboscope enabled the development of flicker-less, hand-held, portable and battery-operating stroboscope. Conclusion: The developed stroboscope is cost-effective, small-sized, easy to use and very easy desirable to bring and to use in any place.

  • PDF

Optimization of Optical Structure of Lightguide Panel for Uniformity Improvement of Edge-lit Backlight (엣지형 LED 백라이트의 균일도 향상을 위한 도광판의 광구조 최적화)

  • Lee, Jung-Ho;Nahm, Kie-Bong;Ko, Jae-Hyeon;Kim, Joong-Hyun
    • Korean Journal of Optics and Photonics
    • /
    • v.21 no.2
    • /
    • pp.61-68
    • /
    • 2010
  • Optical simulation methods were applied to the edge-lit LED backlight for LCD TV applications in order to optimize the optical structure of the light guide plate(LGP), and thus to improve the uniformity properties by removing the bright spots caused by LED's. The edge-lit LED backlight consisted of three white LED's with a lamp cover, a light guide plate, and a reflection film. When there was no pattern on the entrance side surface of the LGP, the illuminance uniformity was sensitively dependent on the distance d between the LED and the entrance surface. The illuminance uniformity increased with d but its increasing rate slowed down when d was beyond ~ 1.5 mm. When micro-patterns such as a lenticular lens array (LLA) or a serration pattern were formed on the entrance surface, the illuminance uniformity was improved substantially even for the case of very small d. At the same simulation condition, the lightguide with serration pattern showed a better uniformity than that with LLA pattern. Additional improvement could be achieved by changing the refractive index of the micro-patterns. These results suggest that using micro-patterns is a very effective way to reduce the bright spots due to their refracting function for the concentrated incident rays onto the LGP.

Rear Vehicle Detection Method in Harsh Environment Using Improved Image Information (개선된 영상 정보를 이용한 가혹한 환경에서의 후방 차량 감지 방법)

  • Jeong, Jin-Seong;Kim, Hyun-Tae;Jang, Young-Min;Cho, Sang-Bok
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.1
    • /
    • pp.96-110
    • /
    • 2017
  • Most of vehicle detection studies using the existing general lens or wide-angle lens have a blind spot in the rear detection situation, the image is vulnerable to noise and a variety of external environments. In this paper, we propose a method that is detection in harsh external environment with noise, blind spots, etc. First, using a fish-eye lens will help minimize blind spots compared to the wide-angle lens. When angle of the lens is growing because nonlinear radial distortion also increase, calibration was used after initializing and optimizing the distortion constant in order to ensure accuracy. In addition, the original image was analyzed along with calibration to remove fog and calibrate brightness and thereby enable detection even when visibility is obstructed due to light and dark adaptations from foggy situations or sudden changes in illumination. Fog removal generally takes a considerably significant amount of time to calculate. Thus in order to reduce the calculation time, remove the fog used the major fog removal algorithm Dark Channel Prior. While Gamma Correction was used to calibrate brightness, a brightness and contrast evaluation was conducted on the image in order to determine the Gamma Value needed for correction. The evaluation used only a part instead of the entirety of the image in order to reduce the time allotted to calculation. When the brightness and contrast values were calculated, those values were used to decided Gamma value and to correct the entire image. The brightness correction and fog removal were processed in parallel, and the images were registered as a single image to minimize the calculation time needed for all the processes. Then the feature extraction method HOG was used to detect the vehicle in the corrected image. As a result, it took 0.064 seconds per frame to detect the vehicle using image correction as proposed herein, which showed a 7.5% improvement in detection rate compared to the existing vehicle detection method.

Study on the Method of Diagnosing the Individuals Crop Growth Using by Multi-Spectral Images

  • Dongwon Kwon;Jaekyeong Baek;Wangyu Sang;Sungyul Chang;Jung-Il Cho;Ho-young Ban;HyeokJin Bak
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 2022.10a
    • /
    • pp.108-108
    • /
    • 2022
  • In this study, multispectral images of wheat according to soil water state were collected, compared, and analyzed to measure the physiological response of crops to environmental stress at the individual level. CMS-V multi-spectral camera(Silios Technologies) was used for image acquisition. The camera lens consists of eight spectral bands between 550nm and 830nm. Light Reflective information collected in each band sensor and stored in digital values, and it is converted into a reflectance for calculating the vegetation index and used. According to the camera manual, the NDVI(Normalized Difference vegetation index) value was calculated using 628 nm and 752 nm bands. Image measurement was conducted under natural light conditions, and reflectance standards(Labsphere) were captured with plants for reflectance calculation. The wheat variety used Gosomil, and the wheat grown in the field was transplanted into a pot after heading date and measured. Three treatments were performed so that the soil volumetric water content of the pot was 13~17%, 20~23%, and 25%, and the growth response of wheat according to each treatment was compared using the NDVI value. In the first measurement after port transplantation, the difference in NDVI value according to treatment was not significant, but in the subsequent measurement, the NDVI value of the treatment with a water content of 13 to 17% was lowest and was the highest at 20 to 23%. The NDVI values decreased compared to the first measurement in all treatment, and the decrease was the largest at 13-17% water content and the smallest at 20-23%. Although the difference in NDVI values could be confirmed, it would be difficult to directly relate it to the water stress of plants, and further research on the response of crops to environmental stress and the analysis of multi-spectral image will be needed.

  • PDF

Design and Fabrication of a LED Floodlight for Naval Vessels (함정용 LED 투광등 설계 및 제작)

  • Kim, Se-Jin;Kil, Gyung-Suk;Kim, Dong-Geon;Kim, Il-Kwon;Song, Dong-Young
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.10
    • /
    • pp.771-777
    • /
    • 2013
  • This paper dealt with the development of a LED floodlight for naval vessels to replace the conventional floodlight using an incandescent and a halogen lamp. We found a technical solution for current problems of conventional lights and also improved optical characteristics by developing a LED floodlight which has a typical long-lived light source with high efficiency. To satisfy the requirements specified in Korea Standard Vessels (KS V), the optical structure was designed with selected LED package and lens. A LED module was composed of 10 LEDs in series for stable luminous output, and an aluminium heat sink was adopted for effective heat-radiation design. The LED floodlight was fabricated as a module type so that it can easily replace the conventional light source. The power consumption of the prototype floodlight was only a tenth of a conventional one with the same optical performance. Also, a test showed the floodlight satisfied the electrical, optical and environmental requirements of the standards.