• Title/Summary/Keyword: light adaptation

Search Result 188, Processing Time 0.024 seconds

CHANGES OF MARGINAL ADAPTATION TO THE CAVITY FLOOR OF LIGHT-CURED GLASS IONOMER CEMENT BASE AFTER APPLICATION OF A COMPOSITE RESTORATION (복합레진 적용에 따른 광중합형 글라스아이오노머 시멘트의 변연 적합도의 변화)

  • Lee, Gye-Young;Lee, Kwang-Won;Park, Soo-Joung
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.1
    • /
    • pp.136-146
    • /
    • 1999
  • The purpose of this study was to estimate the changes of marginal adaptation to the cavity floor of light-cured glass ionomer cement base after application of a composite restoration. Eighty non-carious extracted human molars were used in the present study. Circular cavities were prepared on the center of the exposed dentin surface to 0.5mm, 1.0mm, 1.5mm, 2.0mm in depth and the prepared cavities were pretreated with Dentin conditioner and filled with Fuji II LC(GC Int. Co., Japan). They randomly assigned into 3 groups according to the difference in application of a composite restoration; Group 1(control group): only glass ionomer base, Group 2: The application of a composite restoration surrounded by dentin with class I cavity over glass ionomer base after conventional dentin bonding to the exposed dentin and glass ionomer base, Group 3: The application of composite restoration not-surrounded by dentin over glass ionomer base after conventional dentin bonding to the exposed dentin and glass ionomer base. To examine the interface between cavity floor and light-cured glass ionomer cement base, each groups were sectioned vertically through the center of restorations with diamond saw and the gap size(${\mu}m$) of interface measured by SEM. The results were analyzed by using One Way ANOVA. The results were as follows: 1. Good adaptation between glass ionomer cement base and cavity floor was showed in specimens with 0.5mm, 1.0mm depth base of control group. But in specimens with 1.5mm, 2.0mm depth base of control group, the gap was measured about $15{\mu}m$, $40{\mu}m$ respectively. 2. Gap size in group 2 was significantly higher than that in control group(P<0.05). 3. Gap size in group 3 was significantly higher than that in control group and group 2(P<0.05). 4. It was possible to observe the good adaptation between glass ionomer cement base and dentin which was intermediated with 4-10${\mu}m$ hybrid layer in specimens with 0.5mm, 1.0mm depth base of control group. Cohesive fracture within cement base was observed in all specimens which had the gap between glass ionomer cement base & dentin. 5. It was possible to observe the gap formation between cement base and bonding agent and between composite resin and dentin in all specimens of group 2.

  • PDF

Micro-CT evaluation of internal adaptation in resin fillings with different dentin adhesives

  • Han, Seung-Hoon;Park, Sung-Ho
    • Restorative Dentistry and Endodontics
    • /
    • v.39 no.1
    • /
    • pp.24-31
    • /
    • 2014
  • Objectives: The purpose of present study was to evaluate the internal adaptation of composite restorations using different adhesive systems. Materials and Methods: Typical class I cavities were prepared in 32 human third molars. The teeth were divided into the following four groups: 3-step etch-and-rinse, 2-step etch-and-rinse, 2-step self-etch and 1-step self-etch system were used. After the dentin adhesives were applied, composite resins were filled and light-cured in two layers. Then, silver nitrate solution was infiltrated, and all of the samples were scanned by micro-CT before and after thermo-mechanical load cycling. For each image, the length to which silver nitrate infiltrated, as a percentage of the whole pulpal floor length, was calculated (%SP). To evaluate the internal adaptation using conventional method, the samples were cut into 3 pieces by two sectioning at an interval of 1 mm in the middle of the cavity and they were dyed with Rhodamine-B. The cross sections of the specimens were examined by stereomicroscope. The lengths of the parts where actual leakage was shown were measured and calculated as a percentage of real leakage (%RP). The values for %SP and %RP were compared. Results: After thermo-mechanical loading, all specimens showed significantly increased %SP compared to before thermo-mechanical loading and 1-step self-etch system had the highest %SP (p < 0.05). There was a tendency for %SP and %RP to show similar microleakage percentage depending on its sectioning. Conclusions: After thermo-mechanical load cycling, there were differences in internal adaptation among the groups using different adhesive systems.

The Effect of Light and Darkness on Acclimatization of Laying Hens

  • Izzeldin, B.;Kassim, H.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.13 no.5
    • /
    • pp.694-697
    • /
    • 2000
  • Laying hens kept in different light and dark periods of the day at high ambient temperature of maximum $35^{\circ}C$ were challenged to $38.5{\pm}0.5^{\circ}C$ acute heat 3 hours daily for 7 consecutive days. They were found to have a significant (p<0.01) acclimatization response (rectal temperature) to heat stress during the dark period compared to those exposed to the same temperature during the light period. The blood pH was not significantly different. The partial pressure of carbon dioxide ($PCO_2$) was significantly high (p<0.01) except in day 4. Similarly the blood bicarbonate ($HCO_3$) concentration was significantly high (p<0.05) except day three and day four. Acute heat exposure in the first day increased the body temperature in both groups (Light and Dark) reaching $44^{\circ}C$, followed by gradual reduction in body temperature. The dark treated birds showed rapid reduction in body temperature ($42.88^{\circ}C$) and adaptation to high temperature during days 2-4 but that this was lost to some extent in days 6-8. However this was not obvious in the light treated birds. It is concluded that darkness reduce hyperthermia and enhance acclimatization responses during acute heat stress.

Effect of Bright Light Exposure on Adaptation to Rapid Night Shift : A Field Study of Shift Work Nurses in Psychiatric Ward (순환제교대근무자에서 야간 근무 적응에 대한 광치료 효과)

  • Ko, Young-Hoon;Joe, Sook-Haeng
    • Sleep Medicine and Psychophysiology
    • /
    • v.9 no.1
    • /
    • pp.41-47
    • /
    • 2002
  • Objectives: In a number of simulated night shift studies, timed exposure to bright light improves sleep quality and work performance. We evaluated the effect of bright light on adaptation to night shift work with a field study. Methods: Five female nurses working shifts at Korea University Hospital were recruited for participation in this study. We investigated two series of six consecutive shift rotations comprising three day and three night shifts, using wrist Actigraphy, the Stanford Sleepiness Scale, Visual-analogue scales, STIM and tympanic membrane temperature for daytime sleep quality, alertness, subjective feeling, attention performance, and temperature rhythm. The subjects were exposed to bright light (2,500 lux) from 24:00 to 04:00 a.m. on three consecutive night shifts during the second series, whereas they worked under normal lightening (650 lux) conditions during the first series. Results: Actigraphic assessment of daytime sleep showed no significant difference between the first and third night shift in both baseline and light exposure phase. The mean lowest temperature shifted earlier during baseline phase but not during the light exposure phase. Also, the score for subjective feelings of depression, anxiety, physical discomfort and sleepiness was significantly higher in the third night shift than the first during baseline phase but not during the light exposure phase. Attention and attention switching ability was significantly improved in the third night shift compared to the first night during the light exposure phase but there were no significant changes during the baseline phase. Conclusion: This result suggests that there were no significant differences between the two phases in measures of quality of daytime sleep, but subjective feelings, attention and alertness were enhanced during light exposure. Although some placebo effects and learning effects might influence this result, bright light exposure between midnight and 4:00 a.m. may improve adaptation to night shift. In future, further controlled studies with a larger sample size, including melatonin measurement, are needed for real shift workers.

  • PDF

THE EFFECT OF INTERMITTENT COMPOSITE CURING ON MARGINAL ADAPTATION (복합레진의 간헐적 광중합 방법이 변연적합도에 미치는 영향)

  • Yun, Yong-Hwan;Park, Sung-Ho
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.3
    • /
    • pp.248-259
    • /
    • 2007
  • The aim of this research was to study the effect of intermittent polymerization on marginal adaptation by comparing the marginal adaptation of intermittently polymerized composite to that of continuously polymerized composite. The materials used for this study were Pyramid (Bisco Inc., Schaumburg, U.S.A.) and Heliomolar (Ivoclar Vivadent, Liechtenstein) . The experiment was carried out in class II MOD cavities prepared in 48 extracted human maxillary premolars. The samples were divided into 4 groups by light curing method: group 1- continuous curing (60s light on with no light off), group 2-intermittent curing (cycles of 3s with 2s light on & 1s light off for 90s); group 3- intermittent curing (cycles of 2s with 1s light on & 1s light off for 120s); group 4- intermittent curing (cycles of 3s with 1s light on & 2s light off for 180s). Consequently the total amount of light energy radiated was same in all the groups. Each specimen went through thermo-mechanical loading (TML) which consisted of mechanical loading (720,000 cycles, 5.0 kg) with a speed of 120 rpm for 100hours and thermocycling (6000 thermocycles of alternating water of $50^{\circ}C$ and $55^{\circ}C$). The continuous margin (CM) (%) of the total margin and regional margins, occlusal enamel (OE), vertical enamel (VE), and cervical enamel (CE) was measured before and after TML under a $\times200$ digital light microscope. Three-way ANOVA and Duncan's Multiple Range Test was performed at 95% level of confidence to test the effect of 3 variables on CM (%) of the total margin: light curing conditions, composite materials and effect of TML. In each group, One-way ANOVA and Duncan's Multiple Range Test was additionally performed to compare CM (%) of regions (OE, VE CE). The results indicated that all the three variables were statistically significant (p < 0.05). Before TML, in groups using Pyramid, groups 3 and 4 showed higher CM (%) than groups 1 and 2, and in groups using Heliomolar. groups 3 and 4 showed higher CM (%) than group 1 (p < 0.05). After TML, in both Pyramid and Heliomo)ar groups, group 3 showed higher CM (%) than group 1 (p < 0.05) CM (%) of the regions are significantly different in each group (p < 0.05). Before TML, no statistical difference was found between groups within the VE and CE region. In the OE region, group 4 of Pyramid showed higher CM (%) than group 2, and groups 2 and 4 of Heliomolar showed higher CM (%) than group 1 (p < 0.05). After TML, no statistical difference was found among groups within the VE and CE region. In the OE region, group 3 of Pyramid showed higher CM (%) than groups 1 and 2, and groups 2,3 and 4 of Heliomolar showed higher CM (%) than group 1 (p < 0.05). It was concluded that intermittent polymerization may be effective in reducing marginal gap formation.

The Study of Complementary Standards to Improve Visibility on Crosswalk throughout Verification Studies after Reviewing Standards (횡단보도의 시인성 향상을 위한 기준검토 및 검증 테스트를 통한 보완 기준(안) 연구)

  • Lee, Mi-Ae;Lee, Dong-Hee;Lee, Yoon-Gyeong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.8
    • /
    • pp.14-23
    • /
    • 2014
  • According to the analysis of crosswalk pedestrian accidents, accidents that occur at night represent 70% of all deaths among crosswalk pedestrians when compared to accidents occurring in the daytime. This is due to the poor visibility that hinders drivers to recognize pedestrians at night. Illuminance on the horizontal plane of the road and the current state of crosswalk lighting are not sufficient enough to comply with standards. Thus, we analyzed factors derived from lighting environment studies on improving crosswalk visibility, domestic and foreign crosswalk lighting standards, and subsequently proposed solutions which are needed to raise domestic crosswalk lighting standards, and a means to uphold those standards through proper verification.

Corresponding Color Reproduction on CRT between Illuminated Environment viewing Conditions (관찰환경에 따른 소프트카피의 대응적 색재현)

  • 곽한봉;안성아;서봉우;이영호;안석출
    • Proceedings of the Korea Institute of Convergence Signal Processing
    • /
    • 2001.06a
    • /
    • pp.241-244
    • /
    • 2001
  • A various color device became generalization. Therefore, request about expression of correct color is increased. Device independent color reproduction system acquires and reproduce color of object regardless characteristic of Input/Output device. Human visual system is partially adapted to the CRT monitor's white point and the ambient light. The visual experiments were performed on the effect of the ambient lighting under mixed chromatic adaptation. In this paper, It was found that human visual system is 40% to 60% adapted to CRT monitor's white point light and the rest to ambient light.

  • PDF

A Study on Bracket-Adhesive Combinations in Aspect of Shear Bond Strength and Bond Failure (전단접착강도와 탈락양상을 고려한 브라켓-접착제의 선택)

  • Han, Jae-Ik;Son, Woo-Sung
    • The korean journal of orthodontics
    • /
    • v.28 no.6 s.71
    • /
    • pp.955-974
    • /
    • 1998
  • The purpose of the present study was to seek bracket-adhesive combinations which have adequate bond strength with no enamel and bracket fracture. The shear bond strengths were measured, the sites of failure and the enamel damage were investigated and the peripheral sealing and adaptation between enamel surface, bonding adhesive and bracket were evaluated. 240 noncarious human premolars were divided into twenty four groups of ten teeth. Shear bond strengths of each group were determined in an universal testing machine after two days passed and the debonded specimens were inspected to determine the predominant bond failure sites. To evaluate peripheral sealing and adaption between enamel surface, adhesive and bracket, each specimen was cut longitudinally into two halves which included the midsection of the bracket, adhesive and enamel and exmined in scanning electron microscope. Six different types of brackets were bonded to the tooth with four different type of adhesives. Six different types of brackets were Image, Plastic, Crystaline, Fascination, Transcend 2000 and metal bracket and four different adhesives were No-mix, Light-Bond, OrthoLC and Superbond C&B. From this study, it may be concluded that (1) The mean shear bond strength varied from a high of 36.58 Kg (410.07 Kg/$cm^2$) with the Fascination-Light Bond combination group to a low of 8.93 Kg (75.51 Kg/$cm^2$) with theImage-OrthoLC combination group. When using OrthoLC as adhesive, the mean shear bond strength was significantly lower than that of other combination groups, (2) Regardless of adhesives, the mean shear bond strength of Fascination brackets was relatively high whereas Plastic and Image brackets had low shear bonding strength. The shear bond strength of Crystaline bracket and Transcend 2m was relatively equal to or lower than that of metal bracket, (3) There was a correlation between bond strength, enamel damage and bracket fracture. As the shear bond strength was increased, the rate of enamel damage and bracket fracture were increased, (4) The combination groups that use OrthoLC as adhesive were debonded in shear stress without enamel fracture and bracket fracture, whereas the combination groups that use Superbond C&B as adhesive experienced a relative high enamel fracture rate and bracket fracture rate, (5) Peripheral sealing and adaptation between enamel-adhesive-bracket were relatively good when using Light-Bond or No-mix as adhesive. Regardless of adhesives, adaptation between bracket-adhesive were relatively good in Ceramic brackets, (6) The combination groups which had adequate bonding strength with no enamel and bracket fracture were Crystaline-No mix, Crystaline-Light Bond, Crystaline-OrthoLC, metal-No mix, metal-Light Bond and metal-OrthoLC combination groups.

  • PDF

VLC4WoT : Visible Light Communication for Web of Things

  • Durgun, Mahmut;Gokrem, Levent
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.14 no.4
    • /
    • pp.1502-1519
    • /
    • 2020
  • Recently, new devices have been developed for the Internet of Things concept. The devices commonly use RF (Radio Frequency) based wireless communication. With the increase in the number of devices, the space allocated for the radio frequency band in wireless communication fills rapidly. Visible Light Communication (VLC) is an alternative, secure and economical communication technology that uses light instead of radio frequencies. While Web of Things (WoT) is the adaptation of the experience and knowledge acquired from the web into the internet of things ecosystems. By combining these two technologies, the development of the Visible Light Communication for Web of Things (VLC4WoT) system, which can use VLC and WoT technologies, has been our motivation. In our study, microcontroller control circuit was created for VLC4WoT system. Control of the circuits over the internet was performed. VLC based receiver and transmitter units have been developed for wireless communication. Web based interface was created for control. The test apparatus consisting of four objects with four outputs and a transfer unit was carried out. In this test, communication was achieved successfully. It was presented in the study that VLC can be used in the web of things architecture. In the future, it is envisaged to use this system as a safe and economical system in indoor environments.

AN INVESTIGATION ON THE CHARACTERIZATION OF COMPOSITE RESIN POLYMERIZED BY THE USE OF AN ARGON ION LASER (Argon 이온 레이저 중합에 의한 Composite resin의 물성에 관한 연구)

  • Cho, Hyung-Kyung;Lee, Chung-Suck
    • Restorative Dentistry and Endodontics
    • /
    • v.17 no.1
    • /
    • pp.69-82
    • /
    • 1992
  • An experimental investigation of the physical properties of light curing composite resin P-50 was performed, in which an argon ion laser beam was irradiated. The physical and mechanical properties of laser polymerized composite resin were determined by measuring the compressive strength, diametral tensile strength, curing depth and microhardness depending upon the experimental conditions such as the laser irradiation time(10sec, 20sec, 30sec) and laser power(300mW, 500mW, 1000mW). These observations were compared with a conventional visible light curing technique. In addition, to evaluate the marginal adaptation, Class V cavity was prepared on the buccal or lingual surface of the extracted premolar and filled with P-50 light curing resin. The test samples were irradiated with both light sources so that the interface between the restoration and the tooth structure were observed under scanning electron microscope. The most of physical and mechanical properties of the laser cured resin showed a remarkable improvement than those treated with the conventional light source, while the observations with the scanning electron microscope provided no significant difference for two polymerized sources. From the results in the experiment it appears that the potential of an argon ion laser is of important value of the use in the polymerization of composite resin.

  • PDF