• Title/Summary/Keyword: lifting level

Search Result 128, Processing Time 0.024 seconds

Development of Technical Breakdown Structure Standard in Temporary Works (건설가설공사의 표준기술분류체계 구축)

  • Park, Jun-Mo;Kim, Ok-Kyue;Park, Gil-Bum
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.05a
    • /
    • pp.162-163
    • /
    • 2013
  • A temporary work are lifting equipment that tower crane or lift, and temporary architectures that office building and storage in construction site. And it is main construction work that built and used temporarily like to a scaffolding, a walk plate, and a formwork. This study is to adjust breakdown structure of temporary work to introduce technical tendency. With a site manager, it is collected a detailed statement and compared. As a result to break down a tendency that temporary equipment, additional function, and direct work of temporary technique, first, existing detail technical indexes that group I, group J, group K, and group L are classified. Second, due to set up and manage to main agents in case of existing detail technical indexes that B1, B2, it is not wrong to classify. But, it is somewhat different, and therefore adjust it to same level. Finally, as a technical tendency that temporary equipment, additional function, and direct work of temporary technique, it is adjusted the others.

  • PDF

The structural and non-linear dynamic analysis for radioactive waste container

  • Yu-Yu Shen;Kuei-Jen Cheng;Hsoung-Wei Chou
    • Nuclear Engineering and Technology
    • /
    • v.55 no.8
    • /
    • pp.3010-3016
    • /
    • 2023
  • In recent years, the development of radioactive waste containers for nuclear facility decommissioning and dismantling is a critical issue because the Taiwan domestic boiling water reactor nuclear power plant is going to be decommissioned. The main purpose of this research is to design a metal container that meets the structural requirements of related regulations. At first, the shielding analysis was performed by varying dimensions of radioactive waste to determine the storage efficiency of the container. Then, a series of structural analyses for operational and accidental conditions of the container with full load were conducted, such as lifting, stacking, and drop impact conditions. On the other hand, the field drop impact tests were carried out to ensure structural integrity. The present research demonstrates the structural safety of the developed container for decommissioned nuclear facilities in Taiwan.

Assessment of Basic Physical Activity According to Sex and Age Groups in Elderly Groups in an Urban Community (도시 노인의 성별 및 연령별 기초신체활동 측정 평가)

  • Kim, So-Min;Kim, Dae-Kyung
    • PNF and Movement
    • /
    • v.16 no.2
    • /
    • pp.239-248
    • /
    • 2018
  • Purpose: This study aimed to examine the elderly physical fitness test for elderly people living in urban areas and to evaluate the physical fitness level according to gender and age groups. Methods: The subjects were 180 elderly people aged 65 and over living in urban areas. The elderly people were classified into early old age, middle old age, and advanced old age groups. Five items of the physical fitness test for the elderly (arm curl, chair stand, 2 min step test, back scratch, and chair sit and reach). Results: In analyzing the average of each item by gender and age, a significant difference was found in the results of each item as age increased in all sports, but no difference was observed according to gender except dumbbell lifting. Conclusion: Although the physical fitness level of all ages decreased from early age to late age, the difference in physical fitness according to gender was not significant except the arm curl test. The results of this study can be used as basic data for a new "age-specific exercise program" for the elderly.

The Analysis of Low Back Loading and Muscle Fatigue while Lifting an Asymmetric Load (비대칭무게중심을 지닌 물체 들기 작업시 허리부위 등근육 부하 및 피로 분석)

  • Han, Seung-Jo;Kim, Sun-Uk
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.35 no.2
    • /
    • pp.30-36
    • /
    • 2012
  • This study is aimed to show that an asymmetric load in the frontal plane leads to an increase in low back loading and fatigue in comparison with a symmetric load when workers lift an external weight by investigating previous studies and verifying the phenomenon with an experiment. Ten male subjects are required to lift and hold an given external load at 70cm height during 50sec, then the EMG amplitude and median frequency on bilateral low back muscle groups (Longissimus, Iliocostalis, and Multifidus) are recorded and analyzed. Independent variables are two-level load weight (13kg, 20kg) and three-level LCG (Center, 6.5cm to the right, and 13cm to the right), and dependent variables are EMG amplitude average, difference, and Fatigue Index (FI). Results show that load weight increases significantly amplitude average and FI, but LCG does significantly amplitude difference and FI significantly (P-value < 0.05). Also the correlation coefficient between amplitude difference and FI is over 0.99. These implies that trunk loading should be explained by not EMG amplitude but muscle fatigue aspect since the association between an external load and amplitude is linear, but the relationship between an external load and median frequency as muscle fatigue index is almost exponential.

A Numerical Analysis and Experiment for Micro-Fans (축류 마이크로 홴의 전산해석 및 성능시험)

  • Cho, Jin-Soo;Pyun, Tae-Kyoon;Park, Wang-Sik;Chun, Chang-Kun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.7
    • /
    • pp.895-906
    • /
    • 2000
  • A three dimensional linear frequency-domain lifting surface panel method was used for the aerodynamic analysis of axial flow type micro-fans. As proven by the duct modeling, the tip clearance of the micro-fans tested is large enough to ignore the calculated effect of the duct system. As the numerical results and experimental data agreed well in the operating point region, the method was applicable in the parametric studies to determine the design parameters of axial flow fans. Experiments on micro-fans were carried out based on KS B 6311. The newly designed micro-fan showed improvements in both static pressure rise and volumetric flow rate compared to the existing fans at a given operating condition. No detection of surging and the smooth characteristic curve proved the improvement in performance. To reduce the fan noise in the fan design, it was necessary to make use of the frequency spectrum analysis data. Measurement of sound pressure level for micro-fans was conducted based on KS B 6361 and KS A 0705. The peak - which occurs at blade passage frequency and its higher harmonics due to the fan noise - was not detected. This justifies the design methodology of the blade.

Survival analysis of bank loan repayment rate for customers of Hawassa commercial bank of Ethiopaia

  • Kitabo, Cheru Atsmegiorgis;Kim, Jong Tae
    • Journal of the Korean Data and Information Science Society
    • /
    • v.25 no.6
    • /
    • pp.1591-1598
    • /
    • 2014
  • The reviews of the balance sheet of commercial banks showed that loan item constitutes the largest portion of bank's assets. Although the sector has highest rate of profit, it possesses the greatest risk. Identifying factors that can contribute in lifting-up the loan repayment rate of customers of Hawassa district commercial bank is the major goal of this study. A sample of 183 customers who took loan from October, 2005 to April, 2012 was taken from the bank record. Kaplan-Meier estimation method and univariate Cox proportional hazard model were applied to identify factors affecting bank loan repayment rate. The result from Kaplan-Meier survival estimation revealed that the loan repayment rate is significantly related with loan type, and previous loan experience, educational level and mode of repayment. The log-rank test indicates that the survival probability of loan customers is not statistically different in repaying the loan among groups classified by sex. Moreover, the univariate Cox proportional hazard model result portrayed that educational level, having previous loan experience, mode of repayment, collateral type and purpose of loan are significantly related with loan repayment rate of customers commercial bank. Hence, banks should design loan strategies giving special emphasis on the significant factors while they are giving loans to their customers.

Wind-induced vibration fragility of outer-attached tower crane to super-tall buildings: A case study

  • Lu, Yi;Zhang, Luo;He, Zheng;Feng, Fan;Pan, Feng
    • Wind and Structures
    • /
    • v.32 no.5
    • /
    • pp.405-421
    • /
    • 2021
  • To gain insight into the wind-induced safety concerns associated with attached tower cranes during the construction of super-tall buildings, a 606 m level frame-core tube super-tall building is selected to investigate the wind-induced vibration response and fragility of an outer-attached tower crane at all stages of construction. The wind velocity time history samples are artificially generated and used to perform dynamic response analyses of the crane to observe the effects of wind velocity and wind direction under its working and non-working resting state. The adverse effects of the relative displacement response at different connection supports are also identified. The wind-resistant fragility curves of the crane are obtained by introducing the concept of incremental dynamic analysis. The results from the investigation indicate that a large relative displacement between the supports can substantially amplify the response of the crane at high levels. Such an effect becomes more serious when the lifting arm is perpendicular to the plane of the connection supports. The flexibility of super-tall buildings should be considered in the design of outer-attached tower cranes, especially for anchorage systems. Fragility analysis can be used to specify the maximum appropriate height of the tower crane for each performance level.

A Manifestation of Accounting Conservatism: A Case Study in Malaysia

  • ASON, Yvonne Joseph;BUJANG, Imbarine;JIDWIN, Agnes Paulus;SAID, Jamaliah
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.8 no.2
    • /
    • pp.365-371
    • /
    • 2021
  • In the wake of several high-profile corporate accounting scandals, there has been evidence that companies are more eager to hire Chief Executive Officers (CEOs) with an accounting background. This signals that CEOs with an accounting background are recognized and trusted by the corporate world to boost the quality of financial reporting of a company. If it is so, in the context of combating the earnings management, hiring CEOs with an accounting background (being a conservative accounting practitioner), could become one of the effective internal corporate governance mechanisms (CGM) to bring down the earnings management activities. This study attempts to provide insight into the level of conservatism of the CEO with an accounting background. Following Basu (1997) and Khan and Watt (2009), the firm-year measure of conservatism (C_Score) was obtained, which later was associated with the accounting education of the CEO to determine their relationship. As expected, CEOs with accounting background exhibit a higher level of moral reasoning than their non - accounting educated counterparts. The finding of this study is useful to persuade the policymaker to consider lifting the trend of hiring a CEO with an accounting background as one of the best practices that the companies can work out to lessen earnings management activities.

A study on the job description of paramedics (1급 응급구조사의 직무분석에 관한 연구)

  • Son, In-A
    • The Korean Journal of Emergency Medical Services
    • /
    • v.9 no.1
    • /
    • pp.43-53
    • /
    • 2005
  • The purpose of this study was to survey a perception of frequency & importance level of job performance, from 249 paramedics who were working at fire station. The job related activities of 4 duties, 18 tasks and 145 task elements were checked by 4 rating scale. The data were analyzed using a SPSS program for descriptive statistics. The results of the study were as follows ; 1. Some of the most frequent tasks were medical tx, managing people & organization, trauma care, pt assessment, general coping skill 2. Some of the most frequent task elements were preparation of written reports, operation of pt lifting supplies, transportation of patients on stretchers, administration of cervical collar and utilization of scoop stretcher. 3. Some of the highest level of importance in task were resuscitation of circulation, surgical tx, safety & infection control, environmental emergency care, trauma care. 4. Some of the highest level of importance in task elements were administration of cervical collar, adult CPR, infant CPR, child CPR, and AED. 5. The highest level of task elements in perception of frequency & importance were administration of cervical collar, infection control after pt care, utilization of long back board, disinfection of ambulance after ride a long, care of chest pain pt, care of unconscious pt, tx of asthma. 6. A difference between frequent & importance score were due to lack of supplies(41%), structural problems(30%) and medical control system(16%), lack of skills(10%), Suggestion; 1. This paper would be more reliable and confirm through wilder range of survey. 2. It would be necessary of more depth survey through dacom study from paramedic. 3. Development of field oriented protocol & curriculum that based on task elements which have high score of both frequency & importance level is required.

  • PDF

Factor Analysis of the Somatosensory for Foot according to the Instability Level of Snatch Lifting (역도 인상동작 불안정성 수준에 따른 발바닥 체성감각요인 분석)

  • Moon, Young Jin
    • Korean Journal of Applied Biomechanics
    • /
    • v.30 no.1
    • /
    • pp.7-16
    • /
    • 2020
  • Objective: It is to find factors related to stability through analysis of plantar pressure factors according to the level of instability when performing Snatch. Method: Foot pressure analysis was performed while 10 weightlifters performed 80% of the highest level of Snatch, and motion was classified and analyzed in 3 grades according to the level of instability. Results: First, in Bad Motion, the movement distance of the pressure center in the direction of ML and AP was larger significantly in Phase 2. Second, in Phase 2, the number of zero-crossing in the AP direction was larger statistically significantly in Good Motion. Third, in the bad motion in Phase 3, the number of zero-crossing in the ML direction showed a significantly larger value. Fourth, in Phase 4, it was found that the more stable the lock out motion, the greater the activity of foot controlling in the left and right directions. Fifth, Phase 3, the greater the Maximum/Mean foot pressure value, the more stable the pulling action. Sixth, in Phase 2, the foot pressure was concentrated with a wide distribution in the midfoot and rearfoot. Seventh, the triggering number of the forefoot region was small in the last pull phase. Eighth, the number of triggers in the toe area was significantly higher during Good Motion in Phase 4. Conclusion: Summarizing the factors of instability in Snatch, there was no significant difference in Phase 1 for each condition. In order to enhance the stability in Phase 2, the sensory control ability in the AP direction is required, and focusing the foot pressing motion with a wide distribution in the middle and rear parts increases the instability. In Phase 3, it was found that the more unstable, the more sensory control activity was performed in the ML direction, the stronger the forefoot pressing action should be performed for a stable Snatch. In Phase 4, It is important that the feet sensory control activity in ML directions and the control ability of the toes in order to have stable Lock out motion.