• Title/Summary/Keyword: level of detector

Search Result 506, Processing Time 0.022 seconds

Power Factor Improvement of Single-Phase Three-level Boost Converter (단상 Three-level boost converter의 역률개선)

  • 서영조
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.384-387
    • /
    • 2000
  • In this paper Power factor correction circuit of single-phase three-level boost converter is proposed. The advantage of the proposed control scheme for three-level boost converter are low blocking voltage of each power device low THD(Total Harmonic Distortion) and high power factor. The control scheme is based on the current comparator capacitor compensator and region detector, In simulations the proposed system is validated.

  • PDF

System-Level Saturation Modeling of Thermal Imager (열상장비의 포화 현상에 대한 시스템 모델링)

  • Han, Seungoh;Park, Seung-Man
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.698-702
    • /
    • 2016
  • Thermal imager is now regarded as one of the key observation devices for ISR activities and getting important more and more. As other detectors, however, the thermal detectors also have maximum input and therefore they will be saturated if the input IR energy exceeds the allowed range. The saturation in the thermal detector makes it impossible to distinguish the target from background, as a result, the thermal imager does not perform its own mission anymore. In order to get an insight related with the image saturation, this paper develops a saturation model for a thermal imaging system, not a thermal detector. The proposed modeling starts from analyzing the specification of a thermal imager. Coupled with the characteristic parameters of the object, the saturation model can be used to predict the distance on which the detector is saturated. The proposed saturation model prove its validity by applying it for the case of observing a flash-bang.

A Study on Canny Edge Detector Design Based on Image Fuzzification (이미지 퍼지화 기반 Canny 에지 검출기 설계에 관한 연구)

  • Park, Mi-Young;Kim, Chul-Won;Park, Jong-Hoon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.9
    • /
    • pp.1925-1931
    • /
    • 2011
  • This paper suggests an approach to the subtle concept, "good", through the fuzzy logic and the design of the Canny edge detector of Gray scale images based on the rules of fuzzy anisotropic diffusion. The Canny edge detection algorithms design is to divide the gray levels into pixels and then calculate the diffusion coefficients at each pixel of non-edgy regions. Based on this processing, we present the Canny edge detector implementing fuzzy logic and comparing the results to other existing methods. The proposed approach is the narrow dynamic range of the gray-level image Sharpening the edge detection and has the advantage.

Low-Power ECG Detector and ADC for Implantable Cardiac Pacemakers (이식형 심장 박동 조율기를 위한 저전력 심전도 검출기와 아날로그-디지털 변환기)

  • Min, Young-Jae;Kim, Tae-Geun;Kim, Soo-Won
    • Journal of IKEEE
    • /
    • v.13 no.1
    • /
    • pp.77-86
    • /
    • 2009
  • A wavelet Electrocardiogram(ECG) detector and its analog-to-digital converter(ADC) for low-power implantable cardiac pacemakers are presented in this paper. The proposed wavelet-based ECG detector consists of a wavelet decomposer with wavelet filter banks, a QRS complex detector of hypothesis testing with wavelet-demodulated ECG signals, and a noise detector with zero-crossing points. To achieve high-detection performance with low-power consumption, the multi-scaled product algorithm and soft-threshold algorithm are efficiently exploited. To further reduce the power dissipation, a low-power ADC, which is based on a Successive Approximation Register(SAR) architecture with an on/off-time controlled comparator and passive sample and hold, is also presented. Our algorithmic and architectural level approaches are implemented and fabricated in standard $0.35{\mu}m$ CMOS technology. The testchip shows a good detection accuracy of 99.32% and very low-power consumption of $19.02{\mu}W$ with 3-V supply voltage.

  • PDF

Phoswich Detector for Simultaneous Measuring Alpha/beta Particles (알파/베타선 동시측정용 phoswich 검출기)

  • Kim, Gye-Hong;Park, Chan-Hee;Lee, Kune-Woo;Jung, Chong-Hun;Seo, Bum-Kyoung
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.6 no.2
    • /
    • pp.111-117
    • /
    • 2008
  • The new type phoswich detector consisting of the ZnS(Ag) and plastic scintillator for alpha/beta-ray simultaneous counting was developed for monitoring radiological contamination inside pipes. The detection performance was estimated using the PSD (pulse shape discrimination) method as a function of distance between the scintillator and radioactive source. The attenuation of particles traveling through a thin film for preventing the detector from being contaminated was experimentally estimated. It is concluded from our investigation that the phoswich detector developed can provide a sufficient alpha/beta-ray discrimination. The application of a thin film for preventing the detector from being contaminated was proven to be feasible.

  • PDF

Application of Competitive ELISA Method for Estimation of Urinary Aflatoxin M1 Level (ELISA 방법을 이용한 요중 아플라톡신 M1 측정)

  • Kim, Yong-Dae;Kim, Heon
    • Journal of Life Science
    • /
    • v.23 no.2
    • /
    • pp.306-310
    • /
    • 2013
  • We compared the efficacy of the competitive ELISA method for measuring the level of urinary aflatoxin M1 (AFM1) with that of the HPLC-fluorescence detector (HPLC-FLD) method. The recovery rate of AFM1 with the ELISA method was 105% (73-124%), and the coefficient of variation of the analysis was 6.85%. The ELISA method showed a 0.20 pg/ml and 0.62 pg/ml limit of detection and limit of quantitation, respectively. In correlation analysis, the two methods showed a very strong and statistically significant correlation (R=0.96, p<0.01). However, in spite of the strong correlation, the ELISA method tended to overestimate the urinary AFM1 concentration compared to the HPLC-FLD method. These results suggest that the competitive ELISA method may be a useful technique for measuring the AFM1 level in high-throughput urine samples, but it needs to be corrected with a regression equation from regression analysis with the HPLC-FLD method.

A Study on Response Characteristics of Photoelectric Type Smoke Detector Chamber Due to Dust Color (분진색상에 따른 광전식연기감지기 챔버의 응답특성에 관한 연구)

  • Lee, Ho-Sung;Kim, Si-Kuk
    • Fire Science and Engineering
    • /
    • v.31 no.5
    • /
    • pp.44-52
    • /
    • 2017
  • This paper is based on a study of the response characteristics of photoelectric type smoke detector chambers according to dust color. Due to an amendment to the Fire Safety Codes to automatic fire alarm systems and visual alarm device, the installation of indoor smoke detectors has become mandatory, but in Korea there is still insufficient research on the non-operation or false alarms that could arise in indoor environments by indoor dust and other environmental conditions etc. In light of this, for this study, research was conducted on the indoor adaptability of smoke detector under various colors of fiber dust that were judged to occur most frequently in among the common indoor dust, photoelectric smoke detector with the lattice-type smoke detection chamber that the smoke detector which is most popular in the country was used, and four colors of fiber dust (brown, white, gray and black) were used the test dusts for carrying out dust and sensitivity testing. Also, the voltage of the photocell part of the smoke chamber was measured, and the scattering phenomenon in the chamber was observed. The result of the testing showed that all four dust types were suitable for dust and sensitivity testing under conditions of pollution A. Yet, there were occasions, at pollution B or C, where the brown, white and gray dust would cause fail alarm during operation testing. And black dust was confirmed to cause non-operation during operation testing. In the case of brown and white dust, the voltage measurement result of the photocell part of the smoke chamber confirmed that the voltage increases as the pollution level increases, and in the case of gray and black dust, the voltage decreases.

Mold Oscillation Signal Detector of Eddy Current Mold Level Sensor (과류식(過流式) 연주(連鑄) Mold 탕면(湯面) 위치계(位置計)의 탕면진동신호(湯面振動信號) 검출방법(檢出方法))

  • Lee, Jin-Rak
    • Proceedings of the KIEE Conference
    • /
    • 1988.07a
    • /
    • pp.37-38
    • /
    • 1988
  • In the continuous casting process, mold level sensor control system is very important for the quality of slab & bloom, in this paper, the principle of eddy current molr level sensor was studied and a method of mold oscillation signal detecting was purposed.

  • PDF

Implementation of the omnidirectional target bearing detector utilizing towed linear arrays (예인선배열 센서를 이용한 전방위 표적방위 탐지기 구현)

  • 이성은;천승용;황수복;이형욱
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.5 no.1
    • /
    • pp.59-64
    • /
    • 2002
  • Passive sonar system forms the various beams in any desired directions to obtain the improvement in Signal-to-Noise(S/N) ratio, bearing detection and localization of targets, and the attenuation of interferences from other directions. Detection of modern underwater targets is becoming increasingly difficult as noise reduction technology leads to considerably low-level acoustic emissions. Therefore, the improvement of beamforming is very important to detect modern underwater targets at the long range in the complex environmental sea. Also, to react to the fast attack mobiles such as torpedoes, port and starboard discrimination is required to be performed very quickly. In this paper, we proposed the implementation of omnidirectional target bearing detector without port and starboard ambiguity to detect effectively the low-level underwater targets. The port and starboard discrimination is performed by cardioid processing and the improvement of beamforming utilizes the cross correlation matrix of individual hydrophone pairs of linear array sensors. The sea test result shows that the system implemented is good for the detection of the low-level underwater targets.

FEASIBILITY OF IMAGE PROCESSING TECHNIQUES FOR LAKE LEVEL EXTRACTION WITH C-BAND SRTM DEM

  • Bhang, Kon-Joon;Schwartz, Franklin Walter;Park, Seok-Soon
    • Proceedings of the KSRS Conference
    • /
    • 2008.10a
    • /
    • pp.173-176
    • /
    • 2008
  • Lake studies play an important role in water management, ecology, and other environmental issues. Typically, monitoring lake levels is the first step on the lake studies. However, for the Prairie Pothole Region (PPR) of North America having millions of small lakes and potholes, on-site measurement for lake levels is almost impossible with the conventional gage stations. Therefore, we employed Geographic Information System (GIS) and remote sensing approach with the Shuttle Radar Topography Mission data to extract lake levels. Several image processing techniques were used to extract lake levels for January, 2000 as a one-time snapshot which will be useful in historic lake level reconstruction. This study is associated with other remote sensing datasets such as Landsat imagery and Digital Orthophoto Quadrangle (DOQ). In this research, firstly, image processing techniques like FFT filtering, Lee-sigma, masking with Canny Edge Detector, and contouring were tested for lake level estimation. The semi-automated contouring technique was developed to accomplish the bulk processing for large amount of lakes in this region. Also, effectiveness of each method for bulk processing was evaluated.

  • PDF