• Title/Summary/Keyword: level meter

Search Result 483, Processing Time 0.027 seconds

Evaluating Blasting Induced Damages of Granite (발파에 의한 화강암반의 손상평가)

  • 목영진
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1999.04a
    • /
    • pp.85-92
    • /
    • 1999
  • Blasting induced damage boundary was determined by measuring vibrations adjacent to charging holes. the criterion adopted to define damages is that blasting-induced strains exceeding tension-crack strain level cause damages. The blasting vibrations were measured in terms of acceleration and converted to strains. The tension-crack strain level was determined with tensile strengths and elastic moduli of rock cores. The damage zone was found to be extended radially about 1 meter from the blasthole detonated with 250 to 700 grams of explosives. The comparison of shear wave velocity profiles before and after blasting shows that the damage boundary of 1 meter seems to be reliable.

  • PDF

Open-channel discharges evaluation by the application of smart sensors

  • Khatatbeh, Arwa;Kim, Young-Oh
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.138-138
    • /
    • 2022
  • Understanding a stream's or river's discharge is essential for a variety of hydrological and geomorphological applications at various sizes. However, depending on the stream environment and flow conditions, it is crucial to use the appropriate techniques and instruments. This will ensure that discharge estimations are as reliable as possible. This study presents developed smart system for continuous measurement of open channel discharge and evaluate streamflow measurement over various techniques. This includes developed smart flow meter as flow point measurements, smart water level sensor (installed on Hydraulic Structure ? Weir) and current meters. Advantages and disadvantages of each equipment are presented to ensure that the most appropriate method can be selected. we found that smart water level sensor is more prominent once used during flood event as compared to smart flow meter and current meters, while current meters seems to show better accuracy once applied for open channel.

  • PDF

A Study on the Facilities Distribution based on the Choice Model of the Outdoor Leisure-Facilities in a Neighbourhood Unit of the Megalopolis Citizens. -In terms of the Comparison of Choice Models and the Limitations of Use Areas between the Megalopolis- (대도시 주민의 근린옥외여가시설 선택모형을 기초로 한 시설지 배분에 관한 연구)

  • 최기수;김한배;진양교;진상철;허미선
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.23 no.1
    • /
    • pp.123-139
    • /
    • 1995
  • The megalopolis citizens are reevaluating the expectant value and the perception of leisure aceording to increasing the level of their incomes, The leisure of citizens is increasing in the aspect of quantity and quality of life nowadays In the site planning of leisure, the concrete understanding about people's choice of a leisure site will be the most important thing, not only for the aspect of improvement of the quality of life but also efficiencies of the land use The purposes of chi study are firstly, to find out the factors which are influenced on a choice of Outdoor leisure facilities in neighbourhood unit and to Compare the Characteristics Of Choice models between the three metropolitan areas, secondly, to predict a limitation of use areal according to the change of a needed time based on the metropolitan's standard choice model For the choice model establishment this research used Logit Model which has been used in the field of the traffic, the tourism and the economics. This research made the results which find out the influencing variables with needed times, the accessibility and the percentage of facilities. The lindtations of use areas come out the results which are predicted according to the change of needed times as a most influencing factors. The range of each preferred leisure facility is about 956 meter distant in the neighbourhood park about 644 meter distant in the pocket park about 604 meter distant in the recreation center, about 628 meter distant in the tennis court about 974 meter distant in the private hob by facility and about 528 meter distant in the library from the apartment unit The recreation center and the library are nearer facilities than the other facilities. But these facilities are surveyed to be more or less influenced by an interesting progran, a context of events and the level of useful facilities, etc.

  • PDF

Design and Performance Analysis of Zoom-FFT Based FMCW Radar Level Meter (Zoom-FFT 기반 FMCW 레이더 레벨미터의 설계 및 성능분석)

  • Sanjeewa, Nuwan;Kim, Won-Ho
    • Journal of Satellite, Information and Communications
    • /
    • v.9 no.2
    • /
    • pp.38-44
    • /
    • 2014
  • This paper presents design of a FMCW (Frequency Modulated Continuous Wave) level meter as well as simulation result of the designed system. The system is designed to measure maximum range of 20m since FMCW radar can be used for measuring short range distance. The distance is measured by analyzing the beat signal which is generated as result of mixing transmitting signal with the reflected received signal. The Fast Fourier Transform is applied to analyze the beat signal for calculating the displacement and Zoom FFT technique is used to minimize measurement error as well as increase the resolution of the measurement. The resolution of the measurement of the designed system in this paper is 2.2mm and bandwidth of 1.024GHz is used for simulation. Thus the simulation results are analyzed and compared in various conditions in order to get a comprehensive idea of frequency resolution and displacement resolution.

A Study on Measurement Accuracy and Required Time based on SCPI of Power Meter in Ka Band (Ka 밴드에서 Power Meter 계측 명령어에 따른 측정 정확도와 소요시간에 대한 연구)

  • Cho, Tae-Chong;Shin, Suk-Ho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.20 no.5
    • /
    • pp.51-56
    • /
    • 2020
  • Measurement accuracy and required time is important to make ATE(Automatic test equipment) system in Ka band, and SCPI commands of power meter which is a representative RF test equipment are studied in this paper. Comparison data between FETCH and MEASURE which are SCPI commands are measured in 30 G ~ 31 GHz and -70 ~ +20 dBm using two power sensor. The data show that FETCH which is the fastest SCPI is able to get reliable data in linear interval above noise level. MEASURE which is the best accurate command takes longer time than FETCH, and the longest time is 13.2 seconds. These results offer that measurement accuracy and required time of the two SCPI for power meter and would be used as a guideline for efficient ATE system in Ka band.

Comparison of Salinity of Soups on the Use of Bluetooth Salinity Meter at Childcare Centers in Anyang Area (안양지역 어린이집에서의 블루투스 염도계 사용에 따른 국의 염도 비교)

  • Kim, Hye Won;Pie, Jae Eun
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.4
    • /
    • pp.435-443
    • /
    • 2020
  • We analyzed whether the use of the Bluetooth salinity meter could affect the proper level of salinity in childcare centers. This study was conducted on childcare centers that wish to participate in the sodium reduction project (Bluetooth salinity meter using group, BG) and those that did not participate (Bluetooth salinity meter not using group, NG) among childcare centers registered with Center for Children's Foodservice Management in Anyang from January to December 2019. As a result of comparing the salinity and sodium contents of the soup according to whether or not a Bluetooth salinity meter was used, the salinity and sodium contents of BG was significantly lower than that of NG (p < 0.0001). Salinity and sodium contents in soups tended to decrease as the number of use of the Bluetooth salinity meter increased (p = 0.020). In conclusion, Bluetooth salinity meter can be used as a means to induce voluntary salinity control by cookers regarding sodium reduction education at childcare centers.

An Implementation Strategy for the Physical Security Threat Meter Using Information Technology (정보통신 기술을 이용한 물리보안 위협 계수기 구현 전략)

  • Kang, Koo-Hong
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.7
    • /
    • pp.47-57
    • /
    • 2014
  • In order to publicly notify the information security (Internet or Cyber) threat level, the security companies have developed the Threat Meters. As the physical security devices are getting more intelligent and can be monitored and managed through networks, we propose a physical security threat meter (PSTM) to determine the current threat level of physical security; that is a very similar compared with the one of information security. For this purpose, we investigate and prioritize the physical security events, and consider the impact of temporal correlation among multiple security events. We also present how to determine the threshold values of threat levels, and then propose a practical PSTM using the threshold based decision. In particular, we show that the proposed scheme is fully implementable through showing the block diagram in detail and the whole implementation processes with the access controller and CCTV+video analyzer system. Finally the simulation results show that the proposed PSTM works perfectly under some test scenarios.

Design and Implementation of a Blood-Glucose Meter to Reduce Hematocrit Interference (적혈구 용적률 간섭 보정을 위한 혈당 측정 기기의 설계 및 구현)

  • Cho, Hyuntae
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.15 no.4
    • /
    • pp.167-175
    • /
    • 2020
  • A blood-glucose meter is one of the in vitro diagnostic devices to measure and control the glucose concentration of diabetics. In order to measure the glucose level in the blood, the common method is to measure the amount of electrons, that is, the output current generated by glucose oxidation after a blood sample is inserted into the test strip containing an enzyme. The hematocrit is an obstacle in measuring accurate blood glucose concentration. This paper deals with the design and implementation of a blood-glucose meter to correct the hematocrit interference. We propose a sequential method which measures impedance using the alternating current and then measures glucose in the blood using the direct current. In addition, this paper introduces how to use commercial glucose strips based on the proposed system. Finally, we conducted the performance evaluation of the proposed system by comparing the measured current and impedance with those of the references. As a result, the standard deviation of the current measurement is approximately 0.6nA and the impedance measurement error for measuring the hematocrit is approximately within 1%. The proposed system will improve the accuracy of the conventional blood-glucose meter by reducing the hematocrit interference.

Reliability Verification of the Clothing Pressure Meter Utilizing the Arduino Board (아두이노 활용 의복압 측정기 제작 및 신뢰도 검증)

  • Kim, Nam Yim;Park, Gin Ah
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.46 no.5
    • /
    • pp.723-740
    • /
    • 2022
  • This study aimed to develop an Arduino-based garment pressure device (APD) on the basis of using Single-Tact sensor by suggesting the reliable clothing pressure range and coefficient of selected sensors through the APD calibration process. Once the APD was validated, the pressure of the experimental men's lower body compression wears was measured using the APD and was compared to the pressure measured using the existing air-pack type pressure meter. The subjects were one mannequin and eight men in their 20's, and the trial compression wears were calf sleeves and pants. Clothing pressures were measured in hip, mid-thigh, calf, and ankle. In terms of the 99% confidence level, the experimental clothing pressure measured at the designated measuring points using the APD was considered identical to the one measured using an existing clothing pressure meter. Therefore, on the basis of the experiment results, this study demonstrated that the APD is as reliable as the existing clothing pressure meter within the pressure ranges of 0.54-16.79 kPa and 0.18-25.47 kPa as provided by the SingleTact sensor supplier's data on the basis of using an external ADC (Analog to Digital Converter) module.

Development of Oil Content Meter for Oily Water Separator in Ship (선박 유수분리기용 유분검출기의 개발)

  • 황정웅;정병건;김창화
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.25 no.2
    • /
    • pp.338-344
    • /
    • 2001
  • According to the MARPOL 73/78 of Convention, all ships should have oil filtering equipment and 15 ppm bilge which satisfy Requirements of MARPOL 73/78. This study is concerned with designing and manufacturing a prototype Oil content Meter(OCM) used in machinery area of ship. The prototype OCM is composed of two parts which are oil content sensing module and data processing unit. The oil content sensing module consists of infra-red light source, photo-diode light receivers, and a glass tube for bilge water sample. The data processing unit has a micro-processor as hard core and peripheral devices. The experimental results of prototype OCM and analysis of collected data reveal linear property between transmitted light and scattered light as long as the bilge water has low level content of oil. And this linear property leads to a oil content detecting method which is programmed and loaded into the data processing unit. The performance of the prototype OCM is compared with that of the commercial OCM in the market.

  • PDF