• Title/Summary/Keyword: level gauge

Search Result 248, Processing Time 0.027 seconds

The Micro Pirani Gauge with Low Noise CDS-CTIA for In-Situ Vacuum Monitoring

  • Kim, Gyungtae;Seok, Changho;Kim, Taehyun;Park, Jae Hong;Kim, Heeyeoun;Ko, Hyoungho
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.14 no.6
    • /
    • pp.733-740
    • /
    • 2014
  • A resistive micro Pirani gauge using amorphous silicon (a-Si) thin membrane is proposed. The proposed Pirani gauge can be easily integrated with the other process-compatible membrane-type sensors, and can be applicable for in-situ vacuum monitoring inside the vacuum package without an additional process. The vacuum level is measured by the resistance changes of the membrane using the low noise correlated double sampling (CDS) capacitive trans-impedance amplifier (CTIA). The measured vacuum range of the Pirani gauge is 0.1 to 10 Torr. The sensitivity and non-linearity are measured to be 78 mV / Torr and 0.5% in the pressure range of 0.1 to 10 Torr. The output noise level is measured to be $268{\mu}V_{rms}$ in 0.5 Hz to 50 Hz, which is 41.2% smaller than conventional CTIA.

Analytical Study on Strength Safety of LPG Mini Tank with Column for Level Gauge (레벨게이지용 컬럼을 설치한 LPG 미니탱크의 강도안전성에 관한 해석적 연구)

  • Kim, Chung Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.3
    • /
    • pp.46-50
    • /
    • 2019
  • In this study, the strength stability of an LPG mini tank with a storage capacity of about 250 kg was analyzed by FEM. According to the results of the FEM analysis, it is preferable that the corner radius of the LPG mini tank having a storage capacity of 250 kg is designed to be 175 to 205 mm. Generally, the larger the corner radius of the end plate of the gas storage tank, the higher the safety of the strength, but the volume or capacity of the tank is reduced. Therefore, it is important to derive the optimum design data. Further, in order to securely design the strength of the gas tank, the thickness of the tank is designed to be thick. However, when the thick steel sheet is used, the material and the transportation costs are increased. The result shows that it is preferable to select the optimum thickness of the steel sheet from 4.5 to 5.5 mm. Using the level gauge type of column on the central axis of the gas tank, the safety strength of the LPG tank can be enhanced as much as twice, compared with the tank of the existing level gauge to measure the liquid level by piercing the side wall of the tank.

Monitoring Activities of Permanent GPS Stations at Tide Gauge in South Korea

  • Won, Ji-Hye;Park, Kwan-Dong;Kim, Sang-Ho
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.1
    • /
    • pp.525-528
    • /
    • 2006
  • South Korea has about 80 permanent GPS stations, being used for a variety of applications such as DGPS, RTK, survey and geodesy. Some of them are installed in or near the coastal area for the purpose of maritime navigation. But, until recently, none of them are used for tide gauge benchmark monitoring. In order to monitor the absolute sea level changes, it is necessary to monitor the land uplift or subsidence occurring at tide gauge sites. It is a common practice to use GPS stations installed at tide gauges to determine absolute sea level. This collaborative efforts coordinated by IGS are called TIGA Pilot Project. Many countries including U.S., Canada, European Union nations, Australia and Japan are participating in TIGA, but South Korea is not a member yet. Recently, we established continuously operating GPS stations at tide gauges located in Incheon and Jeju to monitor the movement of tide gauges sites. This paper will introduce goals and progress of the efforts.

  • PDF

A Study on the Gauge Types Comparative Analysis of Basic Jacquard Structure (기본 자카드 조직의 게이지 변화에 따른 특성에 관한 연구)

  • Ki, Hee-Sook
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.19 no.4
    • /
    • pp.1-15
    • /
    • 2017
  • The aim of this study is to plan a design that satisfies consumer needs by forecasting future properties following changes of gauge in basic Jacquard structure and to provide helpful data for a variety of knit-wear development. Four basic Jacquard knit samples (Normal Jacquard, Bird's eye Jacquard, Floating Jacquard, Tubular Jacquard) were selected and projected by using three types of gauges (7G, 12G, 14G) with an SES-122S type Computer Knitting machine of Shimaseiki MFG. Twelve different types of samples with Jacquards and gauges were tested on a flat table by measuring the course and wale in a 1cm area to calculate the gauge of samples. The mechanical properties of 12 types of Jacquard samples were measured using KES-FB (Kawabata Evaluation System for Fabric, Kata Tech Co. Ltd). As the result of comparing the number of patterns, courses and wales depending on the change of gauge of the basic Jacquard structure, it was observed that the number of patterns per specific length, course and wale has increased from 7G to 14G, a high-gauge. According to objective research regarding Jacquard structure, 7G Tubular Jacquard, which is low gauge, seems to be suitable for masculine design as it is heavy and thick, and has rigid and rough texture due to a high level of flexural strength and shear property. 14G Floating Jacquard, which is high gauge, seems to be suitable for feminine, silhouette design as it is light, thin, soft, flexible and has high drape. The result of this study provides a theoretical foundation for knit-wear development considering basic Jacquard structure and gauge-specific properties. This study can be used to provided directions for the development of knit industry.

  • PDF

Characteristics on sea level variations in the South Indian Ocean (남인도양의 해수면 변화 특성)

  • 윤홍주
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.5 no.6
    • /
    • pp.1094-1103
    • /
    • 2001
  • According to standard procedures as defined in the users handbook for sea level data processes, I was compared to Topex/Poseidon sea level data from the first 350days of mission and Tide Gauge sea level data from the Amsterdam- Crozet- Kerguelen region in the South Indian Ocean. The comparison improves significantly when many factors for the corrections were removed, then only the aliased oceanic tidal energy is removed by oceanic tide model(11) in this period. Making the corrections and smoothing the sea level data ()ver 60km along-track segments and the Tide Gauge sea level data for the time series results in the digital correlation and RMS difference between the two data of c=-0.12 and rms= 11.4cm, c=0.55 and rms=5.38cm, c=0.83 and rms=2.83cm, and c=0.24 and rms=6.72 for the Amsterdam, Crozet and Kerguelenplateau, and Kerguelen coast, respectively. It was also found that the Kerguelen plateau has a comparisons due to propagating signals(the baroclinic Rossby wave with velocity of -3.9 ~-4.2cm/sec, period of 167days and amplitude of 10cm) that introduce temporal lags(${\gamma}$: 10~30days) between the altimeter and tide gauge time series. The conclusion is that on timescales longer than about 10days the RMS sea level errors are less than or of the order of several centimeters and are mainly due to the effects of currents rather than the effects of stories(water temperature, density) and winds.

  • PDF

Water Level Measurement Method Based on Temporal Variation of Water Surface Pixel Arrangement in Successive Images (수면 영상의 시간적 픽셀농도변화를 이용한 수위계측방법)

  • Kwon, Sung-Ill;Kim, Won;Lee, Chan-Joo;Kim, Seung-Dong
    • Journal of Korea Water Resources Association
    • /
    • v.43 no.9
    • /
    • pp.781-787
    • /
    • 2010
  • A new method for water level measurement method and its verification results are described. In this method, water surface in motion can be detected by temporal variation of pixel arrangement in successive digital images including the boundary between the staff gauge and the water surface. Laboratory and field tests were conducted for the two cases in which the staff gauge was contaminated by dirt or transparent due to clear water. The result shows water level can be accurately measure by this method for these two cases. It is expected that the accuracy of previous image stage gauge will be improved by the new method.

An Analysis on the Effect of Pressure System Installation on the Pipeline to Identify Pressurized Water and Self-inspection Ease in Apartment Building (아파트에 설치하는 옥내소화전 압력계 설치가 배관의 가압수 식별 및 자체점검 용이성 간의 영향 분석)

  • Son, Joo-Dal;Kong, Ha-Sung
    • Journal of the Korea Safety Management & Science
    • /
    • v.22 no.1
    • /
    • pp.33-44
    • /
    • 2020
  • This study analyzed how the installation of a pressure gauge in the indoor fire hydrant of an apartment building affected identifying pressurized water in the pipe, making it easier to conduct internal inspection on the fire suppression system, and ensuring reliability of fire suppression. The following are the study's results: First, identifying pressurized water in the indoor firefighting pipe had a positive effect on the installation of a pressure gauge in the indoor fire hydrant. This implies that a higher level of identification of pressurized water in the indoor firefighting pipe had a positive impact on improving the installation and use of a pressure gauge in the indoor fire hydrant. Second, making it easier for the fire safety officer to inspect the fire suppression system had a positive effect on the installation of a pressure gauge in the indoor fire hydrant. This suggests that if it becomes easier for the apartment building's stakeholder to conduct internal inspection or the firefighting facility manager to carry out inspection on the fire suppression system, it would have a positive effect on the installation of a pressure gauge in the indoor fire hydrant. Finally, ensuring reliability in fire suppression had a positive effect on the installation of a pressure gauge in the indoor fire hydrant. This implies that if it becomes easier to identify pressurized water in the indoor firefighting pipe, for the fire safety officer to conduct internal inspection, or for the firefighting facility manager to carry out inspection in accordance with the fire suppression system's internal inspection requirements, it would increase reliability in fire suppression, making it more necessary to install a pressure gauge in the indoor fire hydrant.

Development of Realtime Flood Monitoring System composed of CCD Camera and Water Level Gauge (CCD 카메라와 수위계를 조합한 철도교량 실시간 홍수위 감시시스템 개발)

  • Park, Young-Kon;Yoon, Hee-Taek;Kim, Seon-Jong;Shin, Min-Ho;Jung, Seung-Yong
    • Proceedings of the KSR Conference
    • /
    • 2004.06a
    • /
    • pp.224-228
    • /
    • 2004
  • In these days, as it frequently happens that water level in the river exceeds the design floods due to irregular heavy rainfall, so it is required, first of an, to manage with railroad bridge safely. Because train control criterion under heavy rainfall is still not prepared and automatic flood monitoring system for railroad bridges is not used, worry over invisible economic loss due to train passage delay is in existence. Therefore, it is important to secure the safety and detect the risk like turnover or failure of railroad bridges through systematic disaster prevention system. And the transition from conventional monitoring method to real time monitoring method supported by sensors and communication system with high technology is rapidly needed. This research is on developing the real time flood monitoring system which prevents railroad disasters in advance by detecting continuously the water level of railroad bridge through CCD camera and water level gauge.

  • PDF

Sea-Level Trend at the Korean Coast

  • Cho, Kwangwoo
    • Journal of Environmental Science International
    • /
    • v.11 no.11
    • /
    • pp.1141-1147
    • /
    • 2002
  • Based on the tide gauge data from the Permanent Service for Meau Sea Level (PSMSL) collected at 23 locations in the Korean coast, the long-term sea-level trend was computed using a simple linear regression fit over the recorded length of the monthly mean sea-level data. The computed sea-level trend was also corrected for the vertical land movement due to post glacial rebound(PGR) using the ICE-4G(VM2) model output. It was found that the PGR-corrected sea-level trend near Korea was 2.310 $\pm$ 2.220 mm/yr, which is higher than the global average at 1.0∼2.0mm/yr, as assessed by the Intergovernmental Panel on Climate Change(IPCC). The regional distribution of the long-term sea-level trend near Korea revealed that the South Sea had the largest sea-level rise followed by the West Sea and East Sea, respectively, supporting the results of the previous study by Seo et al. However, due to the relatively short record period and large spatial variability, the sea-level trend from the tide gauge data for the Korean coast could be biased with a steric sea-level rise by the global warming during the 20th century.

Estimation of sea level variations of the Java Sea during the ENSO period using the HYCOM

  • Sofian, Ibnu;Kozai, K.;Ohsawa, T.
    • Proceedings of the KSRS Conference
    • /
    • v.2
    • /
    • pp.744-747
    • /
    • 2006
  • The sea level of the Java Sea is reproduced using HYbrid Coordinate Ocean Model (HYCOM) setting up in the horizontal grid from $100^{\circ}E$ to $125^{\circ}E$ and from $10^{\circ}S$ to $8^{\circ}N$. The model is initialized by ocean temperature and salinity profiles from Levitus 1998 and forced by the atmospheric field derived from NCEP reanalysis. In this research HYCOM is applied to explain the El $Ni{\tilde{n}}o$ Southern Oscillation (ENSO) impacts on the sea level of the Java Sea. The monthly tide gauge sea level data are produced based on hourly sea level data from 1993 to 1997. Altimeter sea level data are based on weekly merged products between TOPEX/Poseidon and ERS absolute dynamic topography (ADT). The simulated sea level both HYCOM and ADT agree well with the tide gauge sea level. The sea level of the Java Sea is high during the La $Ni{\tilde{n}}a$ period and low during the El $Ni{\tilde{n}}o$ period.

  • PDF