• Title/Summary/Keyword: lesser Yang

Search Result 93, Processing Time 0.024 seconds

Comparative assessment of the easiness and speed of insertion of three supraglottic airway devices - A manikin study - (3가지 성문위기도기(Supraglottic airway device)의 삽관 용이성과 삽관시간 비교 - 마네킨을 이용한 연구-)

  • Kim, Sang-Tae;Kang, Bo-Ra;Tak, Yang-Ju
    • The Korean Journal of Emergency Medical Services
    • /
    • v.16 no.2
    • /
    • pp.23-30
    • /
    • 2012
  • Purpose : This study was designed to compare the easiness and speed of insertion of three supraglottic airway devices(SADs) in a manikin setting. Methods : Three different SADs - Laryngeal Mask Classic(cLMA), I-gel and Streamlined Liner of the Pharynx Airway(SLIPA) were applied. One hundred and nineteen paramedical students with(group H) or without (group L) previous airway experience were taught brief manikin training about the use of the cLMA, I-gel and SLIPA. The students inserted each device in a randomized order. Time to effective ventilation was recorded in seconds from holding the device to the first chest inflation. Success was determined as adequate chest wall movement. Results : The insertion attempts were lesser in I-gel($1.00{\pm}0.00$) and SLIPA($1.05{\pm}0.27$) than cLMA($1.16{\pm}0.41$, p<.05). The shortest time to insertion was recorded for I-gel($10.5{\pm}3.0sec$), followed by the SLIPA($12.9{\pm}4.5sec$) and cLMA($19.6{\pm}4.1sec$, p<.05). There were no significant differences in the insertion attempts and insertion time of I-gel between group L and group H. But in cLMA, longer insertion time and more insertion attempts were recorded in group L than group H. Conclusion : Both I-gel and SLIPA were superior to cLMA in the easiness and speed of insertion. Even in novice students, I-gel showed an excellent result in a manikin.

Evaluation of Artifact and Noise in the Standard and MAR Algorithms with Variation of Examination Conditions of CT (Standard와 MAR 알고리즘에서 CT 검사조건 변화에 따른 인공물과 노이즈 평가)

  • Kim, Young-kuen;Yang, Sook;Wang, Tae-uk
    • Journal of radiological science and technology
    • /
    • v.43 no.2
    • /
    • pp.79-85
    • /
    • 2020
  • The influence of metal artifact in CT image depends on the type of metal materialsm, the reconstruction algorithm, and scan parameters. The presence of metal artifacts was quantitatively evaluated by applying the standard and MAR algorithms through the phantom study. In the change of tube voltage applied the standard algorithm, metal artifact decreased to 44.9% for 80 vs 120 kVp, 24% for 100 vs 120 kVp, while the image taken at 140 kVp increased the artifact by 19% compared to 120 kVp. When the tube current was increased from 100 to 300 mA, there was no significant difference in the CT value and noise. Black band and white strike artifacts occurred up to 65.9% in the adjacent ROI of the metal driver, whereas titanium screw produced lesser metal artifact than that of the metal driver. The combination of 120kVp or higher tube voltage-standard algorithm was effective in removing black band artifacts as well as white streak by high density materials. However, MAR reconstruction algorithm was useful in improving image quality under the environment of low kVp and high density materials, without increase of radiation exposure.

The Effect of Mitomycin-C on Preventing Adhesion of Injured Flexor Tendon in Rabbit Model (가토의 굴곡건 손상모델에서 Mitomycin-C가 인대 유착 방지에 미치는 영향)

  • Sung, Jung-Hwa;Kang, So-Ra;Kim, Yang-Woo
    • Archives of Plastic Surgery
    • /
    • v.37 no.4
    • /
    • pp.329-334
    • /
    • 2010
  • Purpose: Adhesion after flexor tendon injury is a result of fibrosis between tendon and tendon sheath. This, finally interfere with gliding mechanism of tendon and results in functional problem of hands. Therefore, there have been many trials to reduce adhesion around the tendon. However, there is no standard procedure clinically practiced in hospitals. Mitomycin-C is an antineoplastic alkylating agent that decrease fibroblast proliferation and scar formation. It is commonly used in many surgery to reduce postoperative adhesion. This study was designed to observe the effect of Mitomycin-C on preventing adhesion in injured flexor tendon. Methods: The deep flexor tendon of digit 2 and 4 in the left forepaw of 15 New Zealand White rabbits were subjected to partial tenotomy. In study group, injury site was exposed to a single 5-minute application of Mitomycin-C, and in control group was left untreated. Digit 2 and 4 in the right forepaw of each rabbit were considered as nonadhesion control group. After 2 weeks, the animals were sacrificed and digits were amputated for biomechanical test and histological study. Results: In biomechanical study to measure yield point, mean yield point of non-adhesion control was $17.43{\pm}2.33$ and $25.07{\pm}4.03$ for adhesion control, which proves increase of adhesion in adhesion control group (p<0.05) in 95% confidence. In Mitomycin-C group, mean yield point was $12.71{\pm}4.97$. Compared with adhesion control, there was decrease in adhesiveness in Mitomycin-C group (p<0.05) in 95% confidence. In histological study, the result of adhesion control revealed massive adhesions of bony structure, fibrotic tissue and tendon structure with ablation of the border. However in Mitomycin-C group, we could find increased fibrotic tissue, but adhesion is much lesser than adhesion group and borders between structures remain intact. Conclusion: This study suggests that Mitomycin-C can significantly reduce adhesion of injured flexor tendon in rabbit model.

A Comparison of Consumer Behaviors in China and Taiwan

  • Yang, Ching-Chow
    • International Journal of Quality Innovation
    • /
    • v.3 no.2
    • /
    • pp.183-198
    • /
    • 2002
  • The purpose of this research is mainly to make an analysis and comparison of the purchasing behaviors of consumers in Mainland China and Taiwan. We precede this research with a questionnaire survey. In Mainland China, we targeted consumers of 10 department stores of the Parkson Plaza Co., Ltd. that are located in 10 different cities. In Taiwan, we selected 3 department stores of the Far Eastern Department Stores in 3 cities. The results of this analysis indicate the importance of quality attributes to the consumers for both Mainland China and Taiwan, albeit with some differentiations. The consumers in China are more focused on the merchandise for example as well as imitation, quality and price. Contrarily, the consumers in Taiwan are more attentive to service quality and parking Issues. On the level of evaluation of satisfaction, the differences are not so obvious for both sides. For example, the quality attributes of “No imitation products” and “Friendly servers” are ranked as the most satisfactory items for both sides. Generally speaking, the service quality of Taiwan's department stores is very outstanding. There are also some differences in the areas of lesser satisfaction between consumers of China and Taiwan. The consumers in China identified the quality attribute “the designs of merchandising, display and the usage of each floor” as the most dissatisfactory item, while the performance on this quality attribute is well accepted by the consumers of Taiwan's department stores. Another contradiction is that Taiwan's consumers are more concerned about “Parking”; this quality attribute obtained much less attention from the consumers in Mainland China. From the analysis of determinants that will have impacts on the willingness of customers to buy again, we found that the viewpoints of consumers from both sides are quite similar. The two main factors are “quality of merchandise” and “service quality”. However, the consumers in Mainland China care more about “the price of merchandise”; this is less important to the consumers in Taiwan. We may conclude from the importance and satisfaction level of the quality attributes and determinants for return customers that differences are caused mainly by the different management of the department stores and the different living circumstances of people across the straights.

Utility of False Profile View for Screening of Ischiofemoral Impingement

  • Kwak, Dae-Kyung;Yang, Ick-Hwan;Kim, Sungjun;Lee, Sang-Chul;Park, Kwan-Kyu;Lee, Woo-Suk
    • Hip & pelvis
    • /
    • v.30 no.4
    • /
    • pp.219-225
    • /
    • 2018
  • Purpose: Ischiofemoral impingement (IFI)-primarily diagnosed by magnetic resonance imaging (MRI)-is an easily overlooked disease due to its low incidence. The purpose of this study was to evaluate the usefulness of false profile view as a screening test for IFI. Materials and Methods: Fifty-eight patients diagnosed with IFI between June 2013 and July 2017 were enrolled in this retrospective study. A control group (n=58) with matching propensity scores (age, gender, and body mass index) were also included. Ischiofemoral space (IFS) was measured as the shortest distance between the lateral cortex of the ischium and the medial cortex of lesser trochanter in weight bearing hip anteroposterior (AP) view and false profile view. MRI was used to measure IFS and quadratus femoris space (QFS). The receiver operating characteristics (ROC), area under the ROC curve (AUC) and cutoff point of the IFS were measured by false profile images, and the correlation between the IFS and QFS was analyzed using the MRI scans. Results: In the false profile view and hip AP view, patients with IFI had significantly decreased IFS (P<0.01). In the false profile view, ROC AUC (0.967) was higher than in the hip AP view (0.841). Cutoff value for differential diagnosis of IFI in the false profile view was 10.3 mm (sensitivity, 88.2%; specificity, 88.4%). IFS correlated with IFS (r=0.744) QFS (0.740) in MRI and IFS (0.621) in hip AP view (P<0.01). Conclusion: IFS on false profile view can be used as a screening tool for potential IFI.

Comparison of Subjective Symptoms, Physical Fitness, Depression and Self-efficacy before and after Tai Chi in Patients with Rheumatoid Arthritis: Based on 3 Years' Data (태극권 운동이 류마티스관절염 환자의 주관적 증상, 체력, 우울 및 자기효능감에 미치는 효과: 3개년 자료를 바탕으로)

  • Son, Jung Tae;Hwang, Hye-Young
    • Journal of muscle and joint health
    • /
    • v.25 no.3
    • /
    • pp.230-239
    • /
    • 2018
  • Purpose: The purpose of this study was to evaluate whether subjective symptoms, physical fitness, and emotional variables were improved after participating in a 6-week Tai Chi program in patients with rheumatoid arthritis. Methods: 23 rheumatoid arthritis patients participated in the Yang style Tai Chi for arthritis patients 90 minutes session conducted twice a week at the Arthritis Center of D University Hospital. The main outcome of current studies included self-reported scores of subjective symptoms(pain, sleep satisfaction, and fatigue), physical fitness tests, and depression (PHQ-9) and self-efficacy investigated with questionnaire before and after participating in Tai Chi. Results: After participating in Tai Chi, participants perceived lesser pain (t=2.61, p=.016) and fatigue (Z=-2.32, p=.020), and reported improved sleep satisfaction (t=-3.56, p=.002). In the physical fitness test, there were significant improvement in muscle strength (upper limb: t=-7.19, p<.001, lower limb: t=-4.86, p<.001), and balance (right t=-3.70, p=.001; left t=-2.30, p=.031). Depression (t=3.87, p=.001) and self-efficacy (Z=-3.44, p=.001) improved significantly after participating in Tai Chi. Conclusion: Tai Chi had beneficial effects on subjective symptoms and emotional variables as well as physical fitness. Therefore, the program could be recommended in the patients with rheumatoid arthritis.

Does acellular dermal matrix expand in response to tissue expander inflation?

  • Yang, Chae Eun;Park, Kwang Hyun;Lee, Dong Won;Lew, Dae Hyun;Song, Seung Yong
    • Archives of Plastic Surgery
    • /
    • v.46 no.1
    • /
    • pp.34-38
    • /
    • 2019
  • Background Acellular dermal matrices (ADMs) have recently become widely used in breast reconstruction, but the correlation between the final expander volume and the surface area of the ADM is not well understood. In this study, the expansion of the surface area of ADM and the expander volume was studied retrospectively in cases of acellular dermis-assisted tissue expander breast reconstruction. Methods Twenty cases of immediate breast reconstruction using an ADM-assisted tissue expander from January 2015 to December 2015 were evaluated. In all 20 cases, CGCryoDerm was used as the matrix, with a thickness of 1-3 mm. No slit incisions were made. Finally, the proportional increase in the area of the fully expanded ADM was compared to that of the tissue expander volume. Results The proportional increase in the ADM surface area was calculated to be from 1.1 to 2.46, with a mean value of 1.7. Additionally, under the assumption that the expander had a spherical shape, the increase in its radius (the cube root of its volume) was assessed. The range of the proportional increase in the expander radius was 1.1 to 2.24, with a mean value of 1.66. The proportional increase in the radius of the expanded ADM surface area ranged from 1.04 to 1.34, with a mean ratio of 1.28. Conclusions The results of this study confirmed that the ADM expanded when the tissue expander was inflated. However, the ADM expanded to a lesser extent than the tissue expander, indicating that the muscle and other tissues expanded more than the ADM when the tissue expander was inflated.

Preliminary design of control software for SDSS-V Local Volume Mapper Instrument

  • Kim, Changgon;Ji, Tae-geun;Ahn, Hojae;Yang, Mingyeong;Lee, Sumin;Kim, Taeeun;Pak, Soojong;Konidaris, Nicholas P.;Drory, Niv;Froning, Cynthia S.;Hebert, Anthony;Bilgi, Pavan;Blanc, Guillermo A.;Lanz, Alicia E.;Hull, Charles L;Kollmeier, Juna A.;Ramirez, Solange;Wachter, Stefanie;Kreckel, Kathryn;Pellegrini, Eric;Almeida, Andr'es;Case, Scott;Zhelem, Ross;Feger, Tobias;Lawrence, Jon;Lesser, Michael;Herbst, Tom;Sanchez-Gallego, Jose;Bershady, Matthew A;Chattopadhyay, Sabyasachi;Hauser, Andrew;Smith, Michael;Wolf, Marsha J;Yan, Renbin
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.46 no.1
    • /
    • pp.39.1-39.1
    • /
    • 2021
  • The Local Volume Mapper(LVM) project in the fifth iteration of the Sloan Digital Sky Survey (SDSS-V) will produce large integral-field spectroscopic survey data to understand the physical conditions of the interstellar medium in the Milky Way, the Magellanic Clouds, and other local-volume galaxies. We are developing the LVM Instrument control software. The architecture design of the software follows a hierarchical structure in which the high-level software packages interact with the low-level and mid-level software and hardware components. We adopt the spiral software development model in which the software evolves by iteration of sequential processes, i.e., software requirement analysis, design, code generation, and testing. This spiral model ensures that even after being commissioned, the software can be revised according to new operational requirements. We designed the software by using the Unified Modeling Language, which can visualize functional interactions in structure diagrams. We plan to use the SDSS software framework CLU for the interaction between components, based on the RabbitMQ that implemented the Advanced Message Queuing Protocol (AMQP).

  • PDF

Optomechanical Design and Structure Analysis of Prototype Siderostat for Testing Local Volume Mapper Telescope Control System

  • Lee, Sunwoo;Han, Jimin;Ahn, Hojae;Kim, Changgon;Yang, Mingyeong;Ji, Tae-geun;Lee, Sumin;Kim, Taeeun;Pak, Soojong;Konidaris, Nicholas P.;Drory, Niv;Froning, Cynthia S.;Hebert, Anthony;Bilgi, Pavan;Blanc, Guillermo A.;Lanz, Alicia E.;Hull, Charles L;Kollmeier, Juna A.;Ramirez, Solange;Wachter, Stefanie;Kreckel, Kathryn;Pellegrini, Eric;Almeida, Andr'es;Case, Scott;Zhelem, Ross;Feger, Tobias;Lawrence, Jon;Lesser, Michael;Herbst, Tom;Sanchez-Gallego, Jose;Bershady, Matthew A;Chattopadhyay, Sabyasachi;Hauser, Andrew;Smith, Michael;Wolf, Marsha J;Yan, Renbin
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.46 no.1
    • /
    • pp.38.4-39
    • /
    • 2021
  • The Local Volume Mapper (LVM), for the Sloan Digital Sky Survey V, consists of four 16 cm telescopes with three fiber spectrographs in the Las Campanas Observatory in Chile. With the fixed telescopes on optical tables, the Alt-Alt mounted siderostats point and guide targets during spectrograph exposures. We are developing the integrated LVM instrument control software. Considering international travel restrictions caused by the COVID-19 pandemic in 2021, we decided to make a simplified version of siderostat to test the LVM telescope control system in Korea. The prototype siderostat consists of two aluminum flat mirrors, optomechanical housing structures made by aluminum profiles, and the Planewave L-350 mount. We designed the optical mirrors and the optomechanical structure of the siderostat. From structural analysis at various pointing cases, we estimated the tilt misalignments of mirrors within 4 arcsec, which would affect the telescope pointing errors.

  • PDF

A Case Series of Dojeokganggi-tang for Hot flush in Soyangin Cold Pattern Patients (상열감을 호소하는 소양인의 도적강기탕 치험 3례)

  • Kukhwa Kim;Jieun Park;Hyojae Choi;Seul Lee;Han Chae;Jihwan Kim;Jeongyun Lee
    • Journal of Sasang Constitutional Medicine
    • /
    • v.36 no.1
    • /
    • pp.31-42
    • /
    • 2024
  • Introduction This case series report an attempt to treat Sasang constitutional medicine on Soyangin patients with unspecified hot flush. Methods The patients in this case were diagnosed as Soyangin cold pattern and treated with herb medicine Dojeokgangi-tang. Treatment outcome was monitored retrospectively. Results Persistent hot flush significantly improved to normal levels in all 3 Soyangin patients, and 2 out of 3 showed the effect within 4 weeks, those with more chronic symptoms required more time. Discussion This study suggests the significance of Sasang constitutional medicine treatment in Soyangin patients with Hot flush. Additionally, the characteristics of patients with hot flush presented in this study were verified as meaningful diagnostics indicator of Soyangin lesser yang wind damage. Furthermore, it emphasizes the value of original symptoms as a standard for evaluating treatment effectiveness.