• 제목/요약/키워드: length-to-height ratio

검색결과 620건 처리시간 0.023초

사상인(四象人) 이목비구(耳目鼻口)의 형태학적(形態學的) 특징(特徵) 연구(硏究) (A Morphorlogical Study of Ear, Eye, Nose and Mouth according to the Sasang Constitution)

  • 홍석철;고병희;송일병
    • 사상체질의학회지
    • /
    • 제10권2호
    • /
    • pp.221-270
    • /
    • 1998
  • Objective This research is a study about constitutional diagnosis through the external appearances as a basic principle, and it is for finding shape differences of the ear, eye, nose, mouth according to the Sasang constitution Method We have collected 209 cases of patients of the Sasang Constitutional Department, including employees of the Kyung-Hee Medical Center and took pictures of the frontal view, lateral view, oblique view of face and measured heights, deapth, breadths of ear, eye, nose, mouth with 'The Measurement of R. Martin'. We analyzed shape differences of the face according to the Sasang constitution with certain results Results We got the morphologic characteristics of ear, eye, nose and mouth according to the Sasang constitution as Table 3. -Table 10. Conclusion : 1. The morphologic characteristics of Ear according to the Sasang constitution (1) Morphologic ear length, Physiognomic ear length, Ear lobule length is longer in Taeumin than Soeumin. (2) Physiognomic ear breadth is wider in Taeumin than Soeumin. (3) Physiognomic ear length, lobule length ratio is higher in Taeumin than Soyangin. 2. The morphologic characteristics of Eye according to the Sasang constitution. (1) Inner Palpebral fissure width, 5th Palpebral fissure length, Bizygomatic breadth-Outercanthal distance is the longest in Taeumin (2) Palpebral fissure inclination is widest in Soeumin. (3) Palpebral fissure length is longer in Taeumin than Soeumin. (4) Pupillary diameter ratio is the lowest in Taeumin (5) Palpebral fissure length, width ratio is higher in Soeumin than Taeumin. (6)zygomatic breadth, Bizygomatic breadth-Outercanthal distance ratio is the higher in Taeumin than Soeumin. 3. The morphologic characteristics of Nose according to the Sasang constitution. (1) Nasion depth is deepest in Soyangin. (2) Nasion to pupillary depth is deeper Soyangin than Taeumin. (3) Nasal tip depth, Nostril to Nasalalar depth is deeper Soyangin than Taeumin. (4) Subnasale to Nasalalar depth is the shallowest in Taeumin (5) Nasalalar height is lowest in Soeumin. (6) Nasalalar to Nostril distance is deeper Taeumin than Soeumin. (7) Nasal tip depth, Nasal depth ratio is the highest in Taeumin (8) Nasal depth Nasalalar heightratio is lowest in Soeumin. (9) Midfaceheight, Nasal tip depth ratio is higher Soyangin than Taeumin. 4. The morphologic characteristics of mouth according to the Sasang constitution. (1) Lower mid lip height, Lower philtrum height, Lower quarter lip height, Total middle lip height, Total philtrum height, Total quarter lip height is the shottest in Soyangin. (2) Upper mid lip height, Upper philtrum height is longer in Taeumin than Soyangin (3) Lip inclination is higher in Soeumin than Soyangin. (4) Intercheilion breadth, total height ratio is lowest in Soyangin. (5) Total lip height, Upper philtrum height ratio is higher in Soyangin than Soeumin. (6) Lower lip height Lower quarter lip height ratio is higher in Soyangin than Taeumin. (8) Total lip area is wider in Taeumin than Soyangin.

  • PDF

Cyclic tests and numerical study of composite steel plate deep beam

  • Hu, Yi;Jiang, Liqiang;Zheng, Hong
    • Earthquakes and Structures
    • /
    • 제12권1호
    • /
    • pp.23-34
    • /
    • 2017
  • Composite steel plate deep beam (CDB) is proposed as a lateral resisting member, which is constructed by steel plate and reinforced concrete (RC) panel, and it is connected with building frame through high-strength bolts. To investigate the seismic performance of the CDB, tests of two 1/3 scaled specimens with different length-to-height ratio were carried out under cyclic loads. The failure modes, load-carrying capacity, hysteretic behavior, ductility and energy dissipation were obtained and analyzed. In addition, the nonlinear finite element (FE) models of the specimens were established and verified by the test results. Besides, parametric analyses were performed to study the effect of length-to-height ratio, height-to-thickness ratio, material type and arrangement of RC panel. The experimental and numerical results showed that: the CDBs lost their load-carrying capacity because of the large out-of plane deformation and yield of the tension field formed on the steel plate. By increasing the length-to-height ratio of steel plate, the load-carrying capacity, elastic stiffness, ductility and energy dissipation capacity of the specimens were significantly enhanced. The ultimate loading capacity increased with increasing the length-to-height ratio of steel plate and yield strength of steel plate; and such capacity increased with decreasing of height-to-thickness ratio of steel plate and gap. Finally, a unified formula is proposed to calculate their ultimate loading capacity, and fitting formula on such indexes are provided for designation of the CDB.

돌출부를 갖는 평행평판의 최적 설계를 위한 층류강제대류 해석 (Analysis of laminar forced convection for optimal design of parallel plates with protrusions)

  • 이관수;박철균
    • 설비공학논문집
    • /
    • 제10권1호
    • /
    • pp.129-136
    • /
    • 1998
  • Pressure drop and heat transfer characteristics of a periodically fully developed flow in the flat channel with protrusions are investigated. The effects of shape and location of protrusion on the pressure drop and heat transfer are numerically analyzed in the present study. Taguchi method is used to optimize these parameters. It is found that the ratio of the height of protrusion to channel height shows larger influence on the pressure drop and heat transfer than the ratio of the length of protrusion to module length. As the height of protrusion increases, pressure drop and heat transfer increase, but if the height of protrusion exceeds 2/3 of the channel height, there is a substantial pressure drop. The results also show that the optimal length and height of protrusion are half of the module length and half of the channel height, respectively.

  • PDF

Back-to-Back 보강토옹벽의 옹벽폭비에 따른 최적 보강길이비 산정을 위한 수치해석적 연구 (Numerical Analysis for Optimal Reinforcement Length Ratio According to Width-to-Height Ratio of Back-to-Back MSE)

  • 박춘식;김동광
    • 한국지반공학회논문집
    • /
    • 제36권12호
    • /
    • pp.69-76
    • /
    • 2020
  • Back-to-Back 보강토옹벽은 좁은 구간에 양립하는 옹벽의 형식을 가지기 때문에 벽체간의 이격거리에 따라 보강재가 겹치게 되어 보강재 간의 상호작용에 의한 응력 변화와 일체화된 상태에서 전체가 거동하는 문제 등으로 설계단계에서 신중한 접근이 필요하나 현재 국내에 정형화된 설계기준이나 지침이 전무한 상태이다. 본 연구는 이러한 Back-to-Back 보강토옹벽에 대해 옹벽폭 대 높이비(옹벽폭비, Wb/H)에 따른 최적 보강길이비에 대해 고찰하였다. 옹벽폭비는 FHWA 설계기준의 Case II에 해당하는 1.1H, 1.4H, 1.7H, 2.0H, 높이는 일반적으로 가장 많이 적용되고 있는 3.0m, 5.0m, 7.0m, 10.0m를 대상으로 하였으며, 각 조건에서 수치해석을 통해 FHWA 설계기준의 적정성과 옹벽의 높이 및 옹벽폭비에 따른 최적 보강길이비를 제안하였다.

젊은 여성의 몸통 근육 활성도 분석을 통한 목발 길이 측정 방법의 효율성 비교 (Comparison of the Effects of Different Crutch Length Measurement Methods on Trunk Muscle Activities in Young Females)

  • 전현;오덕원
    • 대한물리의학회지
    • /
    • 제15권1호
    • /
    • pp.77-84
    • /
    • 2020
  • PURPOSE: This study compared the activities of the trunk muscles during crutch walking to determine which of the crutch length measurements is most beneficial. METHODS: Twenty young women volunteered to participate in this study. After adjusting crutch length, the participants performed a three-point walking with nondominant leg limited in weight bearing. This study used six crutch length measurements: (1) Height-40.6cm, (2) Height'.77, (3) Olecranon-to-finger length, (4) Axillary-toheel length, (5) Arm-span length-40.6cm, and (6) Arm-span length'.77. The EMG activities of the internal oblique (IO), rectus abdominis (RA), multifidus (MF), and erector spinae (ES), muscles on the weight bearing side were monitored using wireless surface EMG. RESULTS: The EMG activities of the RA and ES appeared to be significantly different among the crutch length measurements (p<.05). The post-hoc test showed that the 'Arm-span length-40.6cm' was significantly greater in the RA activity when compared to the 'Height'.77' and 'Axillary-to-heel length' measurements, and in the ES activity when compared to 'Height'.77' measurements. Furthermore, IO/RA and MF/ES ratios showed significant differences among the crutch length measurements (p<.05). In the post-hoc test, significant difference was observed between 'Olecranon-to-finger length' and 'Arm-span length-40.6cm' for the IO/RA ratio, and between 'Height'.77' and 'Olecranon-to-finger length' and between 'Height'.77' and 'Arm-span length-40.6cm' measurement for the MF/ES ratio. CONCLUSION: These findings suggest that the 'Height'.77' measurement is relatively advantageous to optimize the activities of trunk muscles during the crutch walking, and allow simple measurements of the crutch length.

체형을 고려한 맞춤형 넥타이 개발에 관한 연구(제1보) -넥타이 길이를 중심으로- (Customized Necktie Design According to Man's Body Characteristics (part I) -Focused on the Length of Necktie-)

  • 박은경;홍지원
    • 한국의류학회지
    • /
    • 제27권11호
    • /
    • pp.1198-1207
    • /
    • 2003
  • The purpose of this study was to develop customized necktie design according to Korean adult male's body characteristics. For this purpose, experimentations of visual sensory evaluation on visual stimuli which show a man's wearing various neckties were carried out. The subjects were students(n=130) majoring in fashion and design related area and experts(n=6). The data were analyzed by ANOVA, duncan test, pearson's correlation coefficient, cross tabulation using spss pc/sup +/ program. Also statistic of Korea adult men's body measurements(1997) were analyzed and used to decide appropriate necktie length according to the customer's various height. The results were as follows: First, there were significant difference in visual sensibility on the stimuli showing 1) relative location of belt and necktie, 2) neckties with various length using golden ratio to the experimental model's height. Therefore, the need of producing neckties with different length according to customer's various height were verified. Second, neckties with three different length(140cm, 145cm, 151cm) were suggested for the groups of 160cm-height, 170cm-height, 180cm-height according to Korean adult male's body characteristics and aspect of production.

Effects of pile geometry on bearing capacity of open-ended piles driven into sands

  • Kumara, Janaka J.;Kurashina, Takashi;Kikuchi, Yoshiaki
    • Geomechanics and Engineering
    • /
    • 제11권3호
    • /
    • pp.385-400
    • /
    • 2016
  • Bearing capacity of open-ended piles depends largely on inner frictional resistance, which is influenced by the degree of soil plugging. While a fully-plugged open-ended pile produces a bearing capacity similar to a closed-ended pile, fully coring (or unplugged) pile produces a much smaller bearing capacity. In general, open-ended piles are driven under partially-plugged mode. The formation of soil plug may depend on many factors, including wall thickness at the pile tip (or inner pile diameter), sleeve height of the thickened wall at the pile tip and relative density. In this paper, we studied the effects of wall thickness at the pile base and sleeve height of the thickened wall at the pile tip on bearing capacity using laboratory model tests. The tests were conducted on a medium dense sandy ground. The model piles with different tip thicknesses and sleeve heights of thickened wall at the pile tip were tested. The results were also discussed using the incremental filling ratio and plug length ratio, which are generally used to describe the degree of soil plugging. The results showed that the bearing capacity increases with tip thickness. The bearing capacity of piles of smaller sleeve length (e.g., ${\leq}1D$; D is pile outer diameter) was found to be dependent on the sleeve length, while it is independent on the sleeve length of greater than a 1D length. We also found that the soil plug height is dependent on wall thickness at the pile base. The results on the incremental filling ratio revealed that the thinner walled piles produce higher degree of soil plugging at greater penetration depths. The results also revealed that the soil plug height is dependent on sleeve length of up to 2D length and independent beyond a 2D length. The piles of a smaller sleeve length (e.g., ${\leq}1D$) produce higher degree of soil plugging at shallow penetration depths while the piles of a larger sleeve length (e.g., ${\geq}2D$) produce higher degree of soil plugging at greater penetration depths.

Lateral buckling formula of stepped beams with length-to-height ratio factor

  • Park, Jong Sup
    • Structural Engineering and Mechanics
    • /
    • 제18권6호
    • /
    • pp.745-757
    • /
    • 2004
  • Lateral-torsional buckling moment resistances of I-shaped stepped beams with continuous lateral top-flange bracing under a single point load on the top flange and negative end moments were investigated. Stepped beam factors and a moment gradient correction factor suggested by Park et al. (2003, 2004) were used to develop new lateral buckling formula for beam designs. From the investigation of finite element analysis (FEA), new lateral buckling formula of beams with singly or doubly stepped member changes and with continuous lateral top-flange bracing subjected to a single point load on top flange and end moments were developed. The new design equation includes the length-to-height ratio factor to account for the increase of lateral-torsional buckling moment resistance as the increase of length-to-height ratio of stepped beams. The calculation examples for obtaining lateral-torsional buckling moment resistance using the new design equation indicate that engineers should easily determine the buckling capacity of the stepped beams.

지하철 구조물의 온도균열제어를 위한 수화열해석 (Analysis for the Control of Thermal Cracks in a Subway Concrete Structure)

  • 김상철;김연태
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 춘계학술대회 논문집
    • /
    • pp.1205-1210
    • /
    • 2004
  • Cracks in the underground structures are mainly observed due to internal ununiformity of thermal stresses or restraint of structural movement in associate with rapid temperature gradient. Especially, thermal cracks are known to occur easily in a massive structure, but possibility of these depend on the amount of cement applied and ratio of span to height of the structure even though the thickness is less than specification‘s. Thus, this study aims at how to control thermal cracks in a massive subway structure and figures out an optimized construction method and procedure. As results of parametric study for length, height and outer temperature for concrete placement, it is found that hydration heats were not affected by both length and height of concrete placement but thermal stresses were greatly dependent. Most effective ways of controling thermal cracks were to fit a proper ratio of length to height of concrete placement and to decrease temperature of concrete placement as much as possible.

  • PDF

Computer-aided approach for modelling of FG cylindrical shell sandwich with ring supports

  • Hussain, Muzamal;Naeem, Muhammad Nawaz;Khan, Muhammad Shabaz;Tounsi, Abdelouahed
    • Computers and Concrete
    • /
    • 제25권5호
    • /
    • pp.411-425
    • /
    • 2020
  • In this paper, the shell material has been taken as functionally graded material and their material quantity is located by the exponential volume fraction law. Moreover, the impact of ring supports around the shell circumference has been examined for their various positions along the shell axial length. These rings support restraints the radial displacement in the transverse direction. While the axial modal deformation functions have been estimated by characteristic beam functions and nature of materials used for construction of cylindrical shells. The fundamental natural frequency of cylindrical shell of parameter versus ratios of length- and height-to-radius for a wide range has been reported and investigated through the study. In addition, by increasing height-to-radius ratio resulting frequencies also increase and frequencies decrease on ratio of length-to-radius. Though the trends of frequency values of both ratios are converse to each other with three different boundary conditions. Also it is examined the position of ring supports with length-to radius ratio, height-to-radius ratio and varying the exponent of volume fraction. MATLAB software package has been utilized for extracting shell frequency spectra. The obtained results are confirmed by comparing with available literature.