Proceedings of the KSR Conference (한국철도학회:학술대회논문집)
- 2004.06a
- /
- Pages.1205-1210
- /
- 2004
Analysis for the Control of Thermal Cracks in a Subway Concrete Structure
지하철 구조물의 온도균열제어를 위한 수화열해석
Abstract
Cracks in the underground structures are mainly observed due to internal ununiformity of thermal stresses or restraint of structural movement in associate with rapid temperature gradient. Especially, thermal cracks are known to occur easily in a massive structure, but possibility of these depend on the amount of cement applied and ratio of span to height of the structure even though the thickness is less than specification‘s. Thus, this study aims at how to control thermal cracks in a massive subway structure and figures out an optimized construction method and procedure. As results of parametric study for length, height and outer temperature for concrete placement, it is found that hydration heats were not affected by both length and height of concrete placement but thermal stresses were greatly dependent. Most effective ways of controling thermal cracks were to fit a proper ratio of length to height of concrete placement and to decrease temperature of concrete placement as much as possible.
Keywords