• Title/Summary/Keyword: length structure

Search Result 3,784, Processing Time 0.039 seconds

Comparison of Biological Characteristics on the Organic Waste-treated Lysimeter Soil by RFLP, PLFA, and CLSU (RFLP, PLFA, CLSU를 이용한 폐기물연용토양의 토양미생물 특성 평가 비교)

  • Jang, Kab-Yeul;Weon, Hang-Yeon;Lee, Kang-Hyo;Kwon, Sun-Ik;Kong, Won-sik;Suh, Jang-sun;Sung, Jae-Mo
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.41 no.6
    • /
    • pp.415-418
    • /
    • 2008
  • The application of sludge wastes into agricultural fields has been increasing annually in Korea. In particular, sewage sludge application has been widely accepted in decades. Sewage sludge application aid in the recycling of essential nutrients and act as a source of organic matter improving the structure and water-holding properties of the soil. The efficient use of sludge wastes, however, requires an individual assessment of waste products. This study assessed the biological characteristics of organic waste-treated lysimeter soils and develop its indicator to assess the soil health of organic waste-treated lysimeter soils. Several analytical techniques more recently developed such as restriction fragment length polymorphism (RFLP), phospholipid fatty acid (PLFA), and community level substrate utilization (CLSU) fingerprints allow for detailed analyses of soil microbial communities. PLFA and RFLP was, therefore, used in the study to characterize the microbial communities in soil without the need to isolate individual fungi and bacteria. PLFA, RFLP and CLSU have been utilized to assess microbial characteristics of the lysimeter soils with four different sludge wastes for eight consecutive years. Each of these methods was analyzed for a different aspect of soil microbial characteristics. The study would disclose those methods yielded highly reproductive results for each soil and allow distinguishing the soils based on the structures of specific geneand PLFA-pools more than CLSU fingerprints. PLFA methods, especially, revealed the same relative similarities of the treated soils based on cluster analysis of the biological characteristics. Pig manure compost-treated soil, however, was only the same relative resemblance among the three methods. These results indicated that PLFA easily assessed the biological soil characterization.

Diagnosis of Spinal Arachnoid Cyst using Magnetic Resonance Imaging in a Dog (개에서 자기공명영상을 이용한 척추부 지주막 낭종의 진단)

  • Shin, Chang-ho;Kim, Young-ki;Hwang, Tae-sung;Yoon, Young-min;Jung, Dong-in;Yeon, Seong-chan;Lee, Hee-chun
    • Journal of Veterinary Clinics
    • /
    • v.32 no.5
    • /
    • pp.464-468
    • /
    • 2015
  • A 6-year-old, intact male maltese was presented with hindlimb ataxia of 4 day duration. Physical and neurological examinations revealed a bright, alert, and responsive dog, with no evidence of cranial nerve deficits, conscious proprioceptive deficits. Spinal reflexes of the hind and forelimbs were normal. Patellar, cranial tibial, and withdrawal reflexes were normal. Pain could not be elicited on manipulation of the neck or palpation of the spinal column. Survey radiographs of the vertebral column were unremarkable. Computed tomography (CT) scans in the transverse plane were performed. The results of CT imaging were unremarkable. Magnetic resonance imaging (MRI) in both sagittal and transverse planes was performed. The extent of the lesion was 25 mm in length by 4 mm in thickness. The spinal cord was deviated ventrally and appreared thinner. On T1-weighted and FLAIR images, a discrete hypointense lesion dorsal to the spinal cord was observed at L1-2 which was contiguous with the subarachnoid space. On T2-weighted images, this region was hyperintense, consistent with a fluid-filled structure. The signal intensity of the cysts was equivalent to cerebrospinal fluid (CSF). Surgical treatment involving dorsal laminectomy had successful outcomes.

The effects of solenoid magnet on plasma extraction in Filtered Vacuum Arc Source (FVAS) (자장여과 아크 소스에서 각 전자석이 플라즈마 인출에 미치는 영향)

  • 김종국;변응선;이구현;조영상
    • Journal of the Korean Vacuum Society
    • /
    • v.10 no.4
    • /
    • pp.431-439
    • /
    • 2001
  • In this paper, the a-Diamond films were synthesized using filtered vacuum arc source (FVAS), FVAS was composed of a torus structure with bending angle of 60 degree. The radius of torus was 266 mm, the radius of plasma duct was 80 mm and the total length was 600 mm. The magnet parts were composed of one permanent magnet and five solenoid magnets. The plasma duct was electrically isolated from the ground so that a bias voltage could be applied. The baffles inside plasma duct were installed in order to prevent the recoil effect of macro-particles. Cathode was made of graphite with 80 mm in diameter. The effects of solenoid magnet on plasma extraction were investigated by computer simulation and experiment using Taguchi's methode. The source and extraction magnet affected the arc stabilization. The extraction beam current was maximized with low value of the source magnet current and high value of the filtering magnet current. The beam current density was 3.2 mA/$\textrm{cm}^2$ and average deposition rate was 5 $\AA$/sec when the currents of arc discharge, source, extraction, bending, deflection and outlet magnet were 30 A, 1 A, 3 A, 5 A, 5 A, and 5 A, respectively. The beam current density and the efficiency of beam transportation were increased with the positive bias voltage of the plasma duct.

  • PDF

Experimental Study on Effect of Slope and Length of Apron on Discharge through Gate Structure (물받이 길이 및 접근경사에 따른 조력발전 배수구조물 통수능 검토 실험 연구)

  • Yoon, Kwang-Seok;Yeo, Kyu-Dong
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.1026-1030
    • /
    • 2005
  • 조력발전 건설사업에서 우선적으로 고려되어야 할 사항은 조수간만에 의해 외해부와 조지부 사이를 이동하는 해수를 적절히 소통시키는 것이다. 예를 들어, 단조지 단류식 발전으로 창조시에 발전을 행할 경우, 발전을 행하면서 높아진 조지내의 수위를 다음 발전을 위해서 낮아진 외해수위를 이용하여 효과적으로 배수시키지 못하면 그 시설은 발전효율이 낮아지게 된다. 즉, 수문구조물의 목적은 주어진 조건 하에서 계획된 유량을 충분히 그리고 안전하게 배제시키는 것이다. 본 연구에서는 수문구조물에 대한 물받이의 길이와 경사의 변화에 의한 외해 조위와 시화호 수위차 조건에 따른 유량계수를 구해 배수능력을 검토하고자 하였다. 이를 위해 시화호를 실험대상으로 하여 수리모형을 1:25의 축척비로 제작하였다. 시화방조제를 기준으로 외해부의 조위와 조지부의 수위차를 8가지의 실험조건으로 한 연구를 수행하였다. 유량계수를 산정하기 위하여 8개 실험조건을 계획에서 제시된 수위-조위 조건에서 수위차 및 통수유량을 분배하여 결정하였고, 유량계수 산정식에 따라 상류 흐름 안정지점에서 유속-면적법에 의해서 유량을 측정하였다. 유속은 8개 지점에 대해서 측정하였고, 각 측정지점에서의 측선은 $3\~5$개이며, 측점은 $3\~4$점법으로 수행하였다. 시화호와 외해의 수위차가 1.011m일 때의 수문을 통과하는 유량을 비교한 결과 실험 II와 III의 통과유량은 각각 $1,571m^3/s$$1,515m^3/s$ 의서 실험 I 의 $587m^3/s$에 비해 통수능이 많이 개선되었음을 알 수 있다. 그림 1은 수위차별 유량곡선을 나타내는 것으로, 실험 II에서의 수문의 통수능이 실험 I의 통수능보다 크게 나타남을 알 수 있었다.>일 때가 밸브를 $60\%$$80\%$ 개폐시켰을 때보다 $0.3kg/cm^2,\;0.29kg/cm^2$ 낮게 나타나 밸브를 전체 개방 했을 때 관로내의 수압이 상수설계기준에 적합한 수압을 유지함을 알 수 있다. 상수관로 설계 기준에서는 관로내 수압을 $1.5\~4.0kg/cm^2$으로 나타내고 있는데 $6kg/cm^2$보다 과수압을 나타내는 경우가 $100\%$로 밸브를 개방하였을 때보다 $60\%,\;80\%$ 개방하였을 때가 더 빈번히 발생하고 있으므로 대상지역의 밸브 개폐는 $100\%$ 개방하는 것이 선계기준에 적합한 것으로 나타났다. 밸브 개폐에 따른 수압 변화를 모의한 결과 밸브 개폐도를 적절히 유지하여 필요수량의 확보 및 누수방지대책에 활용할 수 있을 것으로 판단된다.8R(mm)(r^2=0.84)$로 지수적으로 증가하는 경향을 나타내었다. 유거수량은 토성별로 양토를 1.0으로 기준할 때 사양토가 0.86으로 가장 작았고, 식양토 1.09, 식토 1.15로 평가되어 침투수에 비해 토성별 차이가 크게 나타났다. 이는 토성이 세립질일 수록 유거수의 저항이 작기 때문으로 생각된다. 경사에 따라서는 경사도가 증가할수록 증가하였으며 $10\% 경사일 때를 기준으로 $Ro(mm)=Ro_{10}{\times}0.797{\times}e^{-0.021s(\%)}$로 나타났다.천성 승모판 폐쇄 부전등을 초래하는 심각한 선천성 심질환이다. 그러나 진단 즉시 직접 좌관상동맥-대동맥 이식술로 수술적 교정을 해줌으로써 좋은 성적을 기대할 수 있음을 보여주었다.특히 교사들이 중요하게 인식하는 해방적

  • PDF

Microwave Detector Using $YBa_2Cu_3O_{7-x}$ Grain Boundary Junction ($YBa_2Cu_3O_{7-x}$ 결정입계 접합을 이용한 마이크로파 감지소자)

  • Sin, Jung-Sik;Jo, Chang-Hyeon;Hwang, Du-Seop;Kim, Yeong-Geun;Wi, Dang-Mun;Cheon, Seong-Sun;Sin, U-Seok;Bae, Seong-Jun;Hong, Seung-Beom
    • Korean Journal of Materials Research
    • /
    • v.4 no.6
    • /
    • pp.681-686
    • /
    • 1994
  • Microwave Detector Using $YBa_{2}Cu_{3}O_{7-x}$, Grain Boundary Junction $YBa_{2}Cu_{3}O_{7-x}$ superconductor thin films were deposited on $LaAIO_{3}$ (100) single crystal substrates using a metal organic chemical vapor deposition (MOCVD) method. These films showed the critical temperature of about 9OK and critical current density of over $10^5/A \textrm{cm}^2$at 77K. These films showed granular structure with 0.5~1.5$\mu \textrm{m}$ grains. Bridge-type junctions, 6$\mu \textrm{m}$ in width and 6pm in length, were fabricated using the photolithography and the Ar ion milling techniques. Current-voltage (I-V) characteristics of these junctions with the microwave irradiation at 77K were studied. The critical current densities decreased as the irradiated microwave power increased. When microwaves were irradiated on the bridge at 77K. the I-V charateristics showed constant voltage stcp(Shapiro steps) at $\Delta$=nho/2e.

  • PDF

UWB Bandpass Filter Using Capacitive Coupling with Cross Resonator ("+"자 공진기와 용량성 결합을 이용한 초광대역 대역 통과 여파기)

  • Dong, Thai Hoa;Lee, Jae-Young;Kim, Ihn-Seok
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.5
    • /
    • pp.486-493
    • /
    • 2010
  • This article introduces a novel ultra wideband(UWB) bandpass filter(BPF) with sharp roll-off characteristics in stripline structure. The UWB characteristic is basically obtained from capacitive coupled cross resonator. The resonator has ${\lambda}/2$ length. And at the center of the resonator, two stubs are loaded, one is a ${\lambda}/8$ short-circuited stub and the other is a ${\lambda}/8$ open-circuited stub. The two stubs provide two attenuation poles at lower and upper cutoff frequencies. For input and output lines, two identical capacitively coupled lines have been installed to suppress the unwanted signals in the lower and upper stopbands. The filter has been designed for the U.S. UWB band(3.1~10.6 GHz) with two transmission zeros at 2.4 and 11.1 GHz. The filter has been realized with Low Temperature Core-fired Ceramic(LTCC) green tape which has the dielectric constant of 7.8. Measurement results agree well with HFSS simulation results. Insertion loss less than 0.7 dB and return loss better than 14 dB in the pass band have been measured. The group delay in the center frequency is 0.27 ns and the group delay variation within pass band is less than 0.5 ns. The size of the filter is $6{\times}18{\times}0.6\;mm^3$.

Analysis Evaluation of Impact Behavior of 270,000kL LNG Storage Outer Tank from Prestress Force Loss (프리스트레스 손실량을 고려한 270,000kL급 LNG 저장탱크 외조의 비산물체 속도에 따른 충돌 거동 해석)

  • Lee, Sang-Won;Jun, Ha-Young;Kim, Jang-Ho Jay;Kim, Jun-Hwi;Lee, Kang-Won
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.1
    • /
    • pp.31-40
    • /
    • 2014
  • LNG storage outer tank is a vertically and horizontally prestressed concrete wall structure. Therefore, when the storage tanks become larger, prestressing tendons become longer and eventually the prestressing loss becomes larger. Also, recently, bomb terrors and accidental crashes have occurred frequently on important infrastructures. Therefore, LNG storage tanks are also exposed to these dangerous scenarios, where they need to be evaluated and protected from these threats. Therefore, in this study, the behavior of 270,000 kL LNG storage outer tank impacted by a flying object is evaluated using implicit FEM code, LS-DYNA. In the analysis, the prestress loss due to the increased length of prestressing tendons from enlargement of outer tank is considered. A comparison study between the LNG tanks with and without prestress loss is performed to investigate the impact behavior and the effect of prestressing force change on the safety and serviceability prestressed concrete containment.

A Study on Development of Evaluation Method on Riverine Ecobelt (수변 생태벨트 평가방법 개발에 관한 연구)

  • Cho, Yong-Hyeon;Choi, Dae-Hee
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.42 no.1
    • /
    • pp.123-132
    • /
    • 2014
  • This study aims to develop the diagnostic evaluation method of the riverine ecobelt for construction, conservation, and maintenance of the riverine ecobelt. The value indices in the proposed evaluation method are composed of total 5 fields and 19 elements. The 5 fields are flood control, environmental function, growth of plants, ecobelt function, and restoration potential. Flood control field is composed of total 3 elements such as length, width, and density of green area. Environmental function field is composed of 4 elements such as park use, landscape boundary and edge, microclimate control, non-point pollution control. Growth of plants field is composed of 6 elements such as species composition, forest height, stratum structure, vine plants, plant vitality, and succession of plants. Ecobelt function field is composed of 4 elements such as longitudinal connectivity, lateral connectivity, in-stream forest or habitat, roads on bank top. Restoration potential field is composed of 2 elements such as landform and land use of the immediate vicinity. The score system ranging 1~4 was adopted. The weighting parameters of elements were unified with each other. The final grade system ranging 1~5(1: very good~5: very bad) was adopted, and the final grade was evaluated by the mean values of each field. According to the test application of the diagnostic evaluation method of the riverine ecobelt, the final grades showed effectively the real condition of each site.

A Study on Design of Earth-Retaining Structure Constructed by a Row of Bored Piles (주열식(柱列式) 흙막이벽(壁)의 설계(設計)에 관한 연구(研究))

  • Hong, Won Pyo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.5 no.2
    • /
    • pp.11-18
    • /
    • 1985
  • A row of bored piles has been used in several excavation works to retain the earth. This excavation bracing system has much effect on low-vibration and low-noise during construction. The system is also effective to provide protection to the adjacent existing ground and structures. For the purpose of establishment of a logical design method for the bored piles, first, a theoretical equation to estimate the resistance of piles is derived. Because arching action of soils between piles is considered in the equation, the characteristics of soils and the installation condition of piles would be considered logically from the beginning. Then a method is investigated to decide the interval ratio of piles. According to the method, the interval between piles can be decided from the information of the Peck's stability number, the coefficient of lateral earth pressure and the internal friction angle of soil. Finally, a design method is presented for the bored piles used for excavation work. In the presented design method, such factors as depth of excavation, pile diameter, interval between piles, pile length below bottom of excavation and pile stiffness, can be selected systematically.

  • PDF

The Effects of Insoluble Polymers on Water Stability of Carbon Fiber Reinforced Polymer-MDF Cementitious Composites (불용성 폴리머가 탄소섬유 보강 Polymer-MDF 시멘트 복합재료의 기계적 특성에 미치는 영향)

  • 김태진;박춘근
    • Composites Research
    • /
    • v.12 no.3
    • /
    • pp.84-90
    • /
    • 1999
  • High alumina cement(HAC) and polyvinyl alcohol(PVA) based macro-defect-free(MDF) cement composites were reinforced using short carbon fibers, 3mm in length, 1-4% in weight fraction and insoluble polymers such as polyurethane, epoxy, phenol resin, in order to increase mechanical properties and water stability. The specimens were manufactured by the low heat-press(warmpress) method. In addition, the interface and the cross-linking reaction of cement and polymers was also studied by the SEM and TEM. Flexural strength of HAC/PVA based MDF cementitious composites was proportionally decreased with increasing fiber contents due to the undensified structure around fibers. The flexural strength of insoluble polymer added specimen was decreased with increasing fiber contents, while water stability was dramatically improved. Epoxy resin added specimen showed the highest strength with increasing fiber contents, compared with other specimens. The water stability of fiber content 4% added specimen immersed in water presented about 95%, 87% at 3 and 7 days immersed in water, respectively. The interfacial adhesive strength of fiber-matrix was very much improved due to cross linking reaction of polymer and metal ions of cement. Tensile strength of insoluble polymers added composites as linearly increased with increasing the fiber contents. The epoxy resin added specimen also showed highest tensile strength. The 4% fiber added specimen presented 30~80% higher strength than controlled specimen.

  • PDF