• 제목/요약/키워드: length of steel fiber

검색결과 187건 처리시간 0.024초

폴리올레핀계 구조용 합성섬유보강 콘크리트의 휨성능 및 화재 저항성 (Flexural Performance and Fire Resistance of Polyolefin Based Structural Synthetic Fiber Reinforced Concrete)

  • 박찬기;원종필
    • 한국농공학회논문집
    • /
    • 제50권1호
    • /
    • pp.49-57
    • /
    • 2008
  • This study evaluated the flexural properties and fire resistance of polyolefm based structural synthetic fiber reinforced concrete. The effects of differing fiber length, dimension and fiber volume fraction were studied. Flexural and fire resistance test were conducted in accordance with the JCI SF-4 and RABT time heating temperature curve, respectively. The Flexural test results indicated that the polyolefln based structural fiber reinforcement showed an ability to increase the flexural toughness and good fire resistance significantly(as compared to steel fiber reinforcement).

강판 및 탄소섬유쉬트를 이용한 중공슬래브교의 보강 효과에 관한 실험 연구 (A Experimental Study on the Reinforcing Effects of RC Voided Slab Bridge with Steel Plate/CFS)

  • 구현본;이정우;정광회;정연주;김병석
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.787-792
    • /
    • 2002
  • The voided slab have many advantages, light weight, high load-distribution capacity, low cost and beautiful appearance, etc. But they have also many cracks due to difficulties in designs and construction, analysis, shrinkage, installation and rising force of voided tube. This paper presents the retrofit effects with steel plate(SP)/carbon fiber sheet(CFS) of RC voided slab. As a results of this study, it proved that the strip pattern has to be profitable than full-face pattern in performance such as crack, ultimate loads, stiffness. Retrofit length has many influence on retrofit effects, as the length increases, performance and stability of end blocks higher. Also, it proved that the retrofit on full-section has to be profitable than voided-section in performance, and the overlay length of CFS is desirable to extent approximately and welding(V-cut) has to be efficient than anchors in SP connection. But the kinds of end block and anchor has not influence on retrofit effects.

  • PDF

강섬유와 철근집합체 조합을 이용한 초고강도 섬유보강 철근 콘크리트 I형 보의 연성거동에 관한 실험 (The Ductile Behavior Test of the Ultra High Perfomance Fiber Reinforced I Beam by the Combination of the Fiber and Group of Reinforcement Bar)

  • 박진영;한상묵
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제20권1호
    • /
    • pp.18-24
    • /
    • 2016
  • 본 논문은 강섬유의 일부를 철근집합체로 대체하여 초고강도 섬유보강 철근 콘크리트 I 형보의 연성거동을 유도하는 것을 목적으로 한다. 강섬유와 철근집합체의 조합을 가진 초고강도 콘크리트 I 형보 대한 휨거동 실험을 수행하였다. 강섬유의 혼입률은 0%, 0.7%, 1%, 1.5%, 2%이다. 철근집합체와 PS강연선 집합체가 압축구역에서 콘크리트를 구속하기 위해 사용되었다. 철근집합체와 강연선 집합체의 길이도 실험요소 중 하나이다. 이러한 실험요소를 조합하여 9개의 초고강도 철근 콘크리트 I 형보를 제작하였다. 강섬유 뿐만 아니라 종방향의 철근 집합체도 초고강도 철근 콘크리트 I형 보의 연성거동을 유도하는데 효과를 가지고 있다. 강섬유 혼입률 0.7% 또는 1%와 철근집합체를 사용한 조합이 I형 보의 효과적인 연성 거동을 보여주고 있다. 하중과 처짐관계 및 균열양상 등이 좁은 간격을 가진 작은 직경의 종방향 철근 집합체의 유용성을 나타내고 있다.

아라미드 FRP 스트립과 강판 사이의 계면 부착응력에 관한 실험적 연구 (Experimental Study on Interfacial Bond Stress between Aramid FRP Strips and Steel Plates)

  • 박재우;류재용;최성모
    • 한국강구조학회 논문집
    • /
    • 제27권4호
    • /
    • pp.359-370
    • /
    • 2015
  • 본 연구에서는 AFRP 스트립과 강재사이의 부착거동에 관한 실험적 연구를 수행하였다. 실험적 연구를 통해 AFRP 판과 강판사이의 계면부착거동을 관찰하고, 계면부착응력을 산정하는 것이 본 연구의 목표이다. 실험변수로는 부착길이와 AFRP의 두께를 선택하였으며, 18개의 일면전단시편 제작하여 실험을 수행하였다. 실험결과 부착길이와 AFRP 두께가 증가함에 따라 하중값을 증가하였으며, 부착길이와 AFRP 두께가 증가함에 따라 각각 63%, 86%의 하중값이 증가하였다. 끝으로 강재와 AFRP 사이의 부착응력-슬립관계를 산정하였다. 부착응력-슬립관계는 탄성선형거동을 보이고 있으며, 부착길이와 AFRP 두께는 부착응력과 파괴에너지에 영향을 덜 미치는 것으로 나타났다.

반복하중 하에서 고인성 시멘트 복합체 내 철근의 겹침이음성능 (Lap Splice Performance of Reinforcing Bars in High Performance Fiber Reinforced Cementitious Composite under Repeated Loading)

  • 전에스더;김선우;양일승;한병찬;윤현도
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.181-184
    • /
    • 2005
  • Experimental results on lap splice performance of high performance fiber reinforced cementitious composite(HPFRCC) with fiber types under repeated loading are reported. Fiber types were polypropylene(PP), polyethylene(PE) and hybrid fiber[polyethylene fiber+steel cord(PE+SC)]. The development length($l_d$) was calculated according to the relevant ACI code requirements for reinforcing bars in concrete. The current experimental results demonstrated clearly that the use of fibers in cementitious matrixes increases significantly the splice strength of reinforcing bars in tension. Also, the presence of fibers increased the number of cracks formed around the spliced bars.

  • PDF

FRP바닥판용 신축이음장치 개발 (Development of Bridge Expansion Joint for Fiber Reinforced Polymer Deck)

  • 이영호;박종섭
    • 한국산학기술학회논문지
    • /
    • 제8권2호
    • /
    • pp.348-353
    • /
    • 2007
  • 본 연구에서는 중공형 섬유보강폴리머(Fiber Reinforced Polymer : FRP) 바닥판이 적용된 교량에 적합한 신축이음장치를 개발하고자 신축이음장치의 설계기준 및 특성을 분석하였다. 또한, 신축이음장치를 선정하는 기준이 되는 설계 신축량 산정법과 FRP바닥판 상세를 검토하여, 강콘크리트 거더 교량에 적용 가능한 FRP바닥판용 신축이음장치를 개발 제안하였다.

  • PDF

Dynamic response of reinforced concrete members incorporating steel fibers with different aspect ratios

  • Haido, James H.;Abdul-Razzak, Ayad A.;Al-Tayeb, Mustafa M.;Bakar, B.H. Abu;Yousif, Salim T.;Tayeh, Bassam A.
    • Advances in concrete construction
    • /
    • 제11권2호
    • /
    • pp.89-98
    • /
    • 2021
  • Investigations on the dynamic behavior of concrete members, incorporating steel fibers with different aspect ratios, are limited so far and do not covered comprehensively in prior studies. Present endeavor is devoted to examine the dynamic response of the steel fibrous concrete beams and slabs under the influence of impact loading. These members were reinforced with steel fibers in different length of 25 mm and 50 mm. Four concrete mixes were designed and used based on the proportion of long and short fibers. Twenty-four slabs and beams were fabricated with respect to the concrete mix and these specimens were tested in impact load experiment. Testing observations revealed that the maximum dynamic deflection or ductility of the member can be achieved with increasing the fiber length. Structural behavior of the tested structures was predicted using nonlinear finite element analysis with specific material constitutive relationships. Eight nodes plate elements have been considered in the present dynamic analysis. Dynamic fracture energy of the members was calculated and agreement ratio, of more than 70%, was noticed between the experimental and analysis outcomes.

Strengthening of deficient steel SHS columns under axial compressive loads using CFRP

  • Shahraki, Mehdi;Sohrabi, Mohammad Reza;Azizyan, Gholamreza;Narmashiri, Kambiz
    • Steel and Composite Structures
    • /
    • 제30권1호
    • /
    • pp.69-79
    • /
    • 2019
  • Numerous problems have always vexed engineers with buckling, corrosion, bending, and over-loading in damaged steel structures. The present study aims to study the possible effects of Carbon Fiber Reinforced Polymer (CFRP) for strengthening deficient Steel Square Hollow Section (SHS) columns. To this end, the effects of axial loading, stiffness values, axial displacement, the shape of deficient on the length of steel SHS columns were evaluated based on a detailed parametric study. Ten specimens were tested to failure under axial compression in laboratory and simulated by using Finite Element (FE) analysis based on numerical approach. The results indicated that the application of CFRP sheets resulted in reducing stress in the damage location and preventing or retarding local deformation around the deficiency location appropriately. In addition, the retrofitting method could increase loading the carrying capacity of specimens.

섬유혼입률에 따른 고성능 슬러리 충전 강섬유보강 시멘트 복합체의 휨성능 특성 (Flexural Performance Characteristics of High Performance Slurry Infiltrated Fiber Reinforced Cementitious Composite according to Fiber Volume Fraction)

  • 김승원;조현명;이학용;박철우
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제19권4호
    • /
    • pp.109-115
    • /
    • 2015
  • 본 연구는 SIFCON 형태의 고성능 강섬유보강 시멘트 복합체의 섬유혼입률에 따른 휨실험을 수행하였고, 실험결과를 바탕으로 휨성능을 평가하였다. 슬러리를 충전하는 형태로 일반 섬유보강시멘트와 달리 높은 섬유혼입률을 확보할 수 있는 장점을 가지고 있다. 주요 실험 변수는 섬유혼입률 8.0%, 7.5%, 7.0%, 6.5% 및 6.0% 이며, 각 변수에 대한 휨강도 및 휨인성 특성을 분석하였다. 그 결과, 높은 섬유혼입률로 인하여 초기균열 발생 이후에도 계속적으로 하중이 증가하였으며, 최대강도 이후 충분한 잔류강도를 확보하였다. 또한 최대 50MPa 수준의 높은 휨강도를 발현하였으며, 섬유혼입률에 따른 휨강도 및 휨인성은 비례하여 증가하는 경향으로 나타났다.

Evaluation of ductility and response modification factor in moment-resisting steel frames with CFT columns

  • Hashemi, Seyed Sh.;Sadeghi, Kabir;Vaghefi, Mohammad;Shayan, Kaveh
    • Earthquakes and Structures
    • /
    • 제12권6호
    • /
    • pp.643-652
    • /
    • 2017
  • One of the methods to strengthen the structures against the seismic lateral loading is the employment of the composite columns. A concrete-filled tube (CFT) has the cumulative advantages of steel and concrete. Concrete-filled steel tube columns have been widely used in the moment-resisting frame (MRF) structures, located in both non-seismic zones and high-risk seismic zones. In this paper, the results of studies on two important seismic parameters of ductility and the response modification factor (RMF) of the MRFs with CFT columns are submitted. While the studies are carried out, the effects of span length-story height ratio, the strength of materials and seismic behavior of MRFs are considered. In this regard, the ductility, RMF and the strength of 36 models of the steel MRFs with CFTs are analyzed. The fiber plastic hinges numerical simulation and pushover analysis method are used in the calculations. Based on the obtained results, the RMFs suitable for the 5-, 10- and 15- story frames are proposed.