• Title/Summary/Keyword: length measurement

Search Result 2,195, Processing Time 0.027 seconds

Characteristics of Beam-tilting Slot Array Waveguide Antennas for DBS Reception (DBS 수신용 빔 틸트형 슬롯 어레이 도파관 안테나의 특성)

  • Min, Gyeong-Sik;Kim, Dong-Cheol;Arai, Hiroyuki
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.39 no.3
    • /
    • pp.140-149
    • /
    • 2002
  • This paper describes the characteristics of beam-tilting slot away waveguide antennas for mobile DBS reception. As a basic study of slotted waveguide array, design for 16 slot elements located on a broad-wall waveguide is considered. Design parameters such as slot length, space between each slot and cross slot angle of antennas with the beam-tilting characteristics are calculated by method of moments. Based on these results, the radiation waveguide antennas with 16-element $\times$16-array are designed and fabricated. The measured main beam direction angles of the fabricated antennas are 48$^{\circ}$to 50$^{\circ}$depending on the measured frequencies and it shows good agreement with prediction. The measured 3 dB beam width of elevation pattern is about 13$^{\circ}$, and the axial ratio and the gain measured at DBS band are observed 2.8 dB below and 24 dBi above, respectively. In order to evaluate a performance of the fabricated waveguide planar antenna, it is combined with the satellite tracking control system and the field performance test of antenna mounted on a mobile vehicle is carried out at highway. During the measurement, it was possible to watch television without a break signal in a driving vehicle and an excellent performance of the proposed antennas was demonstrated.

Heat Treatment Effects of $Fe_{73.0}Cu{1.0}Nb_{3.5}Si_{14.0}B_{7.6}$Alloy with Imbedded Nanocrystalline Phase under Magnetic Field (초미세결정립과 비정질이 공존하는 $Fe_{73.9}$$Cu_{1.0}$$Nb_{3.5}$$Si_{14.0}$$B_{7.6}$ 합금의 자기장 중 열처리)

  • Yang, J.S.;Son, D.;Cho, Y.
    • Journal of the Korean Magnetics Society
    • /
    • v.8 no.1
    • /
    • pp.13-20
    • /
    • 1998
  • The crystallographic and high frequency characteristics of $Fe_{73.9}Cu_{1.0}Nb_{3.5}Si_{14.0}B_{7.6}$ soft magnetic alloys were investigated under the magnetic field annealing. As-cast ribbon with which already imbedded nanocrystalline Fe-Si phase on the surface have a preferred orientation with (400) plane to surface and also with the [011] direction parallel to the ribbon length. The extra nanocrystalline Fe-Si phase appeared throughout at 45$0^{\circ}C$ in samples with or without the longitudinal magnetic field. However the formation of nanocrystalline phase does not appear on the suface layer until 50$0^{\circ}C$ annealing temperature under the transverse field. The cryststallization fraction of annealed samples with longitudinal magnetic field is higher than that of samples without magnetic field. When the transverse magnetic field is applied, the crystallization fraction does not increases but decreases until 50$0^{\circ}C$. However the crystallization of internal regions can be confirmed by X-ray diffraction measurement via tilting the sample. It was found that for all samples, the saturation induction were all same with 1.3 T. The coercive field of as-cast sample was 1.06 A/cm, but in annealed samples it decrease from 0.56 to 0.1 A/cm with increasing annealing temperature from 400 and 55$0^{\circ}C$, respectively. The squareness of annealed samples under transverse magnetic field has a small value than that of both without field and with longitudinal field annealing.

  • PDF

An Empirical Comparative Study on the Clustering Measurement Using Fuzzy(Average Index Transformation) DEA and Cross-efficiency Models (퍼지(평균지수변환)DEA모형과 교차효율성모형을 이용한 클러스터링측정에 대한 실증적 비교연구)

  • Park, Ro-Kyung
    • Journal of Korea Port Economic Association
    • /
    • v.31 no.1
    • /
    • pp.85-110
    • /
    • 2015
  • The purpose of this paper is to show the clustering trend and the empirical comparison and to choose the clustering ports for 3 Korean ports(Busan, Incheon and Gwangyang Ports) by using the Fuzzy(Average Index Transformation) DEA and Cross-efficiency models for 38 Asian ports during 11 years(2001-2011) with 4 input variables(birth length, depth, total area, and number of crane) and 1 output variable(container TEU). The main empirical results of this paper are as follows. First, clustering results by using Fuzzy(AIT)DEA show that 3 Korean ports[Busan(56.29%), Incheon(57.96%), and Gwangyang(66.80%) each]can increase the efficiency. Second, according to Cross-efficiency model, Busan(Hongkong, Kobe, Manila, Singapore, and Kaosiung etc.), Incheon(Aquaba, Dammam, Karachi, Mohammad Byin Oasim and Davao), and Gwangyang(Damman, Yokohama, Nogoya, Keelong, Kaosiung, and Bangkok) should be clustered with those ports in parentheses. Third, when both Fuzzy(AIT)DEA and Cross-efficiency models are mixed, the empirical result shows that 3 Korean ports[Busan(71.38%), Incheon(103.89%), and Gwangyang(168.55%) each]can increase the efficiency. The efficiency ranking comparison among the three models by using Wilcoxon Signed-rank Test was matched with the average level of 66%-67%. The policy implication of this paper is that Korean port policy planner should introduce the Fuzzy(AIT)DEA, and Cross-efficiency models with the mixed two models when clustering is needed among the Asian ports for enhancing the efficiency of inputs and outputs. Also, the results of SWOT analysis among the clustering ports should be considered.

Far-Infrared Emission Characteristics of Germanium Included Fabrics for Emotional Garment (게르마늄 함유 감성의류용 직물의 원적외선 방출 특성)

  • Kim, Hyun-Ah;Kim, Seung-Jin
    • Science of Emotion and Sensibility
    • /
    • v.13 no.4
    • /
    • pp.687-692
    • /
    • 2010
  • This paper surveys emission characteristics of Far-infrared of the fabrics fabricated with germanium imbedded sheath-core conjugate composite filaments. For this purpose, master batch chip was prepared with PET semi-dull chip and nano sized germanium particles and sheath-core type conjugate composite filament was spun using this master batch chip and polyester semi dull. The emission power and emissivity of the germanium imbedded fabrics were measured and investigated using FT-IR spectrophotometer by KICM- FIR 1005 measurement method. In addition, the fabric mechanical properties were measured and discussed with the effects of the optimum texturing process conditions and fabric structural design conditions. The sheath/core type PET composite germanium imbedded filaments were manufactured by the optimum spinning condition, its tenacity and breaking strain showed the same level as the regular PET filament. The tenacity and breaking strain of the DTY showed good physical properties and no problem in the weaving process. Then, wet and dry shrinkages showed higher values than those of regular PET filament. The emission power of the germanium imbedded fabric was $3.53{\times}10^2W/m^2$ at the $5-20{\mu}m$ wave length range, and emissivity was 0.874. The fabric hand of germanium imbedded fabrics was inhanced by the optimum texturing process and fabric structural design with improved mechanical properties such as fabric bending and compressional properties.

  • PDF

Fabrication of X-ray monocapillary optics for soft X-ray fluorescence analysis (경 X선 형광분석을 위한 모세관 광학소자 제작)

  • Cho, Hyung-Wook;Park, Byung-Hoon;Kim, Yong-Min;Choi, Chul-Hee;Choi, Seong-Hee;Kim, Ki-Hong;Chon, Kwon-Su
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.6
    • /
    • pp.409-413
    • /
    • 2011
  • An X-ray tube used an X-ray fluorescence analysis system has a low X-ray photon intensity which results in reducing measurement accuracy and increasing exposure time. These shortages can be overcame by using a monocapillary optics. A monocapillary optics was optimally designed for focusing the characteristic X-ray of tungsten (8.4 keV). The monocapillary optics can achieve a gain of 10 at the least. The monocapillary optics was fabricated by using puller and pyrex glass, raw material. In fabrication, a weigh of 45g and a temperature of $650^{\circ}$ was loaded. The total fabrication time was 460 minutes. The fabricated capillary had 87 mm in length and maximum diameter of 300 ${\mu}m$ and minimum diameter of 192 ${\mu}m$. When the fabricated monocapillary optics is applied to an X-ray fluorescence analysis system, the detection accuracy for soft elements, for example sulfur (S), will be improved.

Characterization of a Micro Power Generator using a Fabricated Electroplated Coil (전기도금 방법으로 제작한 코일을 이용한 초소형 발전기의 특성분석)

  • Lee, Dong-Ho;Kim, Seong-Il;Kim, Young-Hwan;Kim, Yong-Tae;Park, Min-Chul;Lee, Chang-Woo;Baek, Chang-Wook
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.13 no.3 s.40
    • /
    • pp.9-12
    • /
    • 2006
  • We have designed and fabricated micro power generators by electroplating which is important in MEMS(micro electro mechanical system) technique. We have electroplated MEMS coils on the glass substrates and have chosen one of these coils for experiments. The thickness, width, and length of the coil are $7{\mu}m,\;20{\mu}m$, and 1.6 m, respectively. We have analyzed the structure of MEMS coil by SEM. We have made a vibrating system for reproducible results in measurement. With reciprocating a magnet on the surface of a fabricated winding coil, the micro power generator produce an alternating voltage. We have changed the vibrational frequency from 0.5 Hz to 8 Hz. The generated voltage was 106 mV at 3 Hz and 198 mV at 6 Hz. We aim at the micro power generator which can change vibration energy to useful electric energy.

  • PDF

Evaluation of Half Cell Potential Measurement in Cracked Concrete Exposed to Salt Spraying Test (염해에 노출된 균열부 콘크리트의 반전위 평가)

  • Kim, Ki-Bum;Park, Ki-Tae;Kwon, Seung-Jun
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.6
    • /
    • pp.621-630
    • /
    • 2013
  • Several techniques for steel corrosion detection are proposed and HCP (half cell potential) technique is widely adopted for field investigation. If concrete has cracks on surface, steel corrosion is rapidly accelerated due to additional intrusion of chloride and carbon dioxide ions. This study is for an evaluation of HCP in cracked concrete exposed chloride attack. For this work, RC (reinforced concrete) beams are prepared considering 3 w/c ratios (0.35, 0.55, and 0.70) and several cover depths (10~60 mm) and various crack widths of 0.0~1.0 mm are induced. For 35 days, SST (salt spraying test) is performed for corrosion acceleration, and HCP and corrosion length of rebar are evaluated. With increasing crack width, w/c ratios, and decreasing cover depth, HCP measurements increase. HCP evaluation technique is proposed considering the effects of w/c ratios, crack width, and cover depth. Furthermore anti-corrosive cover depths are obtained through Life365 program and the results are compared with those from this study. The results shows relatively big difference in cracked concrete, however provide similar anti-corrosive conditions in sound concrete.

Radio Frequency Circuit Module BGA(Ball Grid Array) (Radio Frequency 회로 모듈 BGA(Ball Grid Array) 패키지)

  • Kim, Dong-Young;Jung, Tae-Ho;Choi, Soon-Shin;Jee, Yong
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.37 no.1
    • /
    • pp.8-18
    • /
    • 2000
  • We presented a BGA(Ball Grid Array) package for RF circuit modules and extracted its electrical parameters. As the frequency of RF system devices increases, the effect of its electrical parasitics in the wireless communication system requires new structure of RF circuit modules because of its needs to be considered of electrical performance for minimization and module mobility. RF circuit modules with BGA packages can provide some advantages such as minimization, shorter circuit routing, and noise improvement by reducing electrical noise affected to analog and digital mixed circuits, etc. We constructed a BGA package of ITS(Intelligent Transportation System) RF module and measured electrical parameters with a TDR(Time Domain Reflectometry) equipment and compared its electrical parasitic parameters with PCB RF circuits. With a BGA substrate of 3${\times}$3 input and output terminals, we have found that self capacitance of BGA solder ball is 68.6fF, and self inductance 146pH, whose values were reduced to 34% and 47% of the value of QFP package structure. S11 parameter measurement with a HP4396B Network Analyzer showed the resonance frequency of 1.55GHz and the loss of 0.26dB. Routing length of the substrate was reduced to 39.8mm. Thus, we may improve electrical performance when we use BGA package structures in the design of RF circuit modules.

  • PDF

Implementation about measurement of the head SAR and variable parameter according to operation control mode in brain MR study with 1.5Tesia (1.57 BRAIN MRI검사에서의 작동제어모드를 통한 두부 SAR측정과 변화인자에 관한 고찰)

  • Lee, Kyu-Su;Sim, Hyun;Moon, Ji-Hoon;Oh, Jae-Cheol
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.58-60
    • /
    • 2007
  • Magnetic Resonance Imaging(MRI) has become a very widely used medical procedur e. Clo.sed and open systems are typically used with static magnetic fields at or below 2 Tesla. BWhole body SAR(specific absorbsion rate) is the value of SAR averaged over the entire body of the patient over any period of 15 minutes. Head SAR is the value of SAR averaged over the head of the patient for any period of 10 minutes. SAR is a measure of the absorption of electromagnetic energy in the body' (typically in watts per kilogram (W/kg)). The normal operating mode comprises values of head SAR not higher than 3 W/kg. The second level controlled operating mode comprises values higher than 3 W/kg. Current FDA guidance limits the SAR in the whole body. including the head to a range of 1.5 to 4.0 W/kg, depending on the patient's clinical condition. SAR, limit restrictions are incorporated in all MRI systems. and domestic' s guidance limits the SAR in a part body. including the head to 3.2w/kg and less. The purpose of this study is to evaluate on change of head SAR in using MRI pulse sequence and to check if exceed 3.2(w/kg) level in domestic a part exposure through measured head SAR. 23 patient's the average head SAR of pulse sequence is that T2WI sagittal is 0.5375. T2WI axial(FSE) is 0.4817, T1WI axial(SE) is, 0.8179. FLAIR axial is 0.4580. GRE axial is 0.0077, Diffusion is 0.0824w/kg. The head SAR exposed per patient was proved 2.3845w/kg less than the international standard. Coefficient of correlation for the relations body weight and SAR or for the relations ETL(echo train length) and SAR is 1 value. Coefficient of correlation for the relations between TR(time to repeat) and SAR is -0.602 value. so SAR increased relative to weight body and ETL. But the relations between TR and SAR is negative definite.

  • PDF

Effects on Labor Pain and Length of Delivery Time for Primipara Women treated by San-Yin-Jian(SP-6) Acupressure and Hob-Gog(LI-4) Acupressure (산부의 삼음교(SP-6).합곡(LI-4)지압이 분만통증과 분만소요시간에 미치는 효과)

  • Kim, Young-Ran;Chang, Soon-Bok;Lee, Mi-Kyeong;Maeng, Woong-Jaeg
    • Women's Health Nursing
    • /
    • v.8 no.2
    • /
    • pp.244-256
    • /
    • 2002
  • The purpose of this study was to examine the effects on labor pain and duration of delivery time for primipara women treated by San-Yin-Jiao(SP-6) and Hob-Gog(LI-4) acupressure. The design of this study was a nonequivalent control group non-synchronizedpost test only design. It was done to identify the effects of SP-6 acupressure or LI-4 acupressure on labor pain in primipara women. The benefits of using SP-6 acupressure or LI-4 acupressure were evaluated by comparing three groups, a SP-6 acupressure group, a LI-4 acupressure group and a control group, not treated with acupressure. The participants included 192 primiparas who underwent vaginal delivery, 72 primiparas in the control group, 71 in the SP-6 acupressure group and 49 in the LI-4 acupressure group. Data were collected using a structured questionnaire consisting of general characteristics, a subjective labor pain scale (Johnson, 1974), and measurement of duration of delivery time. The results of this study are summarized as follows : 1. Differences in the acupressure effect for SP-6 and LI-4 were analyzed using Scheffe's test which showed that differences in the control group vs the SP-6 group and the control group vs the LI-4 group were statistically significant (t=21.767, p<0.05; t=23.923, p<0.05), but the SP-6 group vs the LI-4 group showed no significant differences. 2. The duration of delivery time in the group which had SP-6 acupressure or LI-4 acupressure was shorter (400.77${\pm}$153.34; 379.10${\pm}$127.60) than in the control group (528.68${\pm}$239.08). Differences in the effects of acupressure with SP-6 and LI-4 were also analyzed by Scheffe's test. Control group vs SP-6 group and Control group vs LI-4 group were significantly different(t=127.91, p<0.05; t=149.58, p<0.05), but the SP-6 group vs the LI-4 group did not show any statistically significant difference (t=21.67). This study has shown that SP-6 and LI-4 acupressure were both effective in relation to labor pain and duration of delivery time for primiparas. But it is necessary to replicate the study with a larger number of participants to generalize of the results.

  • PDF