• Title/Summary/Keyword: length measurement

Search Result 2,201, Processing Time 0.034 seconds

Fabrication of diffractive optical element for objective lens of small form factor data storage device (초소형 광정보저장기기용 웨이퍼 스케일 대물렌즈 제작을 위한 회절광학소자 성형기술 개발)

  • Bae H.;Lim J.;Jeong K.;Han J.;Yoo J.;Park N.;Kang S.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2005.09a
    • /
    • pp.35-40
    • /
    • 2005
  • The demand for small and high-capacity optical data storage devices has rapidly increased. The areal density of optical disk is increased using higher numerical aperture objective lens and shorter wavelength source. A wafer-scale stacked micro objective lens with a numerical aperture of 0.85 and a focal length of 0.467mm for the 405nm blue- violet laser was designed and fabricated. A diffractive optical element (DOE) was used to compensate the spherical aberration of the objective lens. Among the various fabrication methods for micro DOE, the UV-replication process is more suitable for mass-production. In this study, an 8-stepped DOE pattern as a master was fabricated by photolithography and reactive ion etching process. A flexible mold was fabricated for improving the releasing properties and shape accuracy in UV-molding process. In the replication process, the effects of exposing time and applied pressure on the replication quality were analyzed. Finally, the shapes of master, mold and molded pattern were measured by optical scanning profiler. The deviation between the master and the molded DOE was less than 0.1um. The efficiency of the molded DOE was measured by DOE efficiency measurement system which consists of laser source, sample holder, aperture and optical power meter, and the measured value was $84.5\%$.

  • PDF

Determination of Aluminum Leached from Cooking Utensils by using Flow Injection Analysis (흐름주입분석법에 의한 주방용기로부터 용출된 알루미늄의 정량)

  • Choi, Yong Wook
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.3
    • /
    • pp.281-289
    • /
    • 2004
  • Optimal analytical conditions have been established for mixing and reaction coil length, concentrations of ECR, CTAB, and acetate, reaction temperature and pH in the determination of aluminum by using flow injection analysis(FIA). Detection limit and repeatability for this system were $3{\mu}g/L$ and better than 1% of relative standard deviation, respectively. The interference from iron(III) was suppressed up to 6mg/L of iron(III) by $0.1{\mu}M$ ascorbic acid, and the interference from fluoride could be tolerated in absorption of Al/ECR/CTAB derivative by 10mM boric acid at pH 3.5 adjusted with nitric acid. This FIA system was applied to the determination of aluminum leached from cooking utensils by distilled and tap water containing fluoride ranged from 0.5 to 2mg/L by measurement of absorbance for Al/ECR/CTAB at 585nm. The leached aluminum content was increased with increasing concentration of fluoride. The aluminum contents leached from aluminum utensils by tap water were about 9 fold higher than those leached by distilled water, whereas aluminum contents leached by distilled water containing fluoride were about 2 fold higher compared to those leached by distilled water. That represented that other dissolved substances as well as fluoride in tap water contributed to liberation of aluminum from aluminum utensils. A comparison between FIA data and ICP-AES data by correlation and paired t test showed that the FIA system could be accepted as a good alternative method for the determination of aluminum in tap water.

Experimental study on the damping estimation of the 5$\times$5 rod bundle (5$\times$5 봉다발의 감쇄추정을 위한 실험적 연구)

  • Lee, Kang-Hee;Yoon, Kyung-Ho;Song, Kee-Nam
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.503-506
    • /
    • 2005
  • The PWR Nuclear Fuel assembly consists of more than 250 fuel rods that are supported by leaf springs in the cells of more than 10 Spacer Grids (SG) along the rod length. Since it is not easy to conduct mechanical tests on a full-scale model basis, the small-scaled rod bundle (5$\times$5) is generally used for various performance tests during the development stage. As one of the small-scaled tests, a flow test should be carried out in order to verify the performance of the spacer grid like the coolant mixing performance and to obtain the Flow-Induced Vibration (FIV) characteristics of the rod bundle over the specified flow range. A vibration test should be also performed to obtain the modal parameters of the bundle prior to the flow test. In this study, we want to develop the estimation procedure of the damping ratio for the small scaled test bundle. For the damping factor of the rod bundle and the grid case at the first vibration mode, as one of the vibration tests, a so-called pluck testing has been performed in air as a preliminary test prior to in-flow damping measurement test. Logarithmic decrement method is used for calculation of the damping ratio. Estimated damping ratio of the rod bundle is about 0.7% with reasonable error of 2% for the previous results. Nonlinear behavior of the rod bundle might be stem mainly Iron the rod-grid support configuration.

  • PDF

Structural and Rheological Properties of Sweet Potato Starch Modified with 4-$\alpha$-Glucanotransferase from Thermus aquaticus

  • Lee, Seung-Hee;Choi, Seung-Jun;Shin, Sang-Ick;Park, Kwan-Hwa;Moon, Tae-Wha
    • Food Science and Biotechnology
    • /
    • v.17 no.4
    • /
    • pp.705-712
    • /
    • 2008
  • Sweet potato starch was modified using Thermus aquaticus $\alpha$-1,4-glucanotransferase ($Ta{\alpha}GT$), and its structural and rheological properties were investigated. $Ta{\alpha}GT$-modified starch had a lower amylose level and molecular weight than raw starch. The chain length distribution showed an increased number of short and long branched chains and the formation of cycloamyloses. Compared with raw starch, $Ta{\alpha}GT$-modified starch displayed a lower gelatinization enthalpy and a wider melting temperature range. The X-ray diffraction of $Ta{\alpha}GT$-modified starch was a weak V-type pattern with distinct sharp peaks at 13 and $20^{\circ}$. Scanning electron micrographs of modified starch exhibited big holes on the surface and the loss of granular structure. The frequency sweep measurement revealed that the gel of $Ta{\alpha}GT$-modified starch was more rigid than raw starch gel. However, the structure of modified starch gel was destroyed by heating at $75^{\circ}C$, and a firm gel was re-formed by subsequent storage at $5^{\circ}C$, indicating thermoreversible property.

A Study on Correlation among Physical Fitness, Diet Intakes and Serum Lipid in Middle Aged Women. (중년여성의 체력, 식이섭취와 혈청지질과의 상관관계에 대한 연구)

  • 안창순
    • The Korean Journal of Food And Nutrition
    • /
    • v.6 no.4
    • /
    • pp.255-267
    • /
    • 1993
  • This study was performed to investigate the correlations among physical anthropometric measurement, diet intakes, physical fitness test, and serum lipids in eight sedentary women(control group), and twenty seven exercising women(aerobic groups), aged 35~45 years. The results of the study are as follows : 1) systolic blood pressure(SBP) and diastolic blood pressure(DBP) of aerobic groups were lower than serf entary. Pulse rate was decreased according to the length of aerobic periods. Muscular endurance and jump power of all subjects were stronger than standard range, and those of aerobic exercising groups were stronger than control group. Muscular power of the upper half of the body In all subjects were lower than standard range. 2) Daily calorie intakes of all subjects were in the ring: of recommended dietary allowances (RDA) for Koreans. But daily protein Intakes were higher than RDA. daily cholestrol intakes of all subjects were slightly less than 200~300 mg: which is normal consumption of Koreans. 3) There was a significant positive correlation between serum 7G and daily protein intakes. It was considered that excessive protein intake converted to serum 7G. There was not a significant correlation between serum TC and dietary TC. Therefore, dietary TC seemed to have not much effect on serum TC. Physical fitness was negatively related to serum TG, TC, LDL-C, but positively related to HDL-C, HDL-C /TC. It was found that the serum lipids could be changed better according to improving the physical fitness. There were significant positive correlations between SBP and serum TC, LDL-C. (According to this results), the higher SBP, the higher serum TC, LDL-C tended to be. There was a significant positive correlations between sit up and weightloss nth exercise r=0.7(p<0.001), push ups and weightless with exercise r=0.5(p<0.001). It was considered that muscle strength could be improved according to the weightloss. 4) The purpose of exercise in aerobic groups was rather promoting health than reducing body fatness. Most of al1 subjects (83.2%) drank caffeine-contained beverage therefore, we should concern about that absorption of Fe could be Interrupted and blood pressure could be elevated by caffeine.

  • PDF

Transmission Line using Microstrip-Slotline Transition Technology and Its Application to Power Divider (마이크로스트립과 슬롯라인 천이기술을 이용한 전송선로 구현과 전력 분배기에 응용)

  • Kim, Young;Sim, Seok-Hyun;Yoon, Young-Chul
    • Journal of Advanced Navigation Technology
    • /
    • v.17 no.6
    • /
    • pp.687-692
    • /
    • 2013
  • This paper presents a compact power divider using microstrip-slotline transition technology. By using the microstrip-slotline transition, the ${\lambda}/4$ transmission lines of the divider can be changed to two ${\lambda}/8$ transmission lines in the multilayer structure. In the microstrip-slotline transition, we have used via holes to make a short circuit at the microstrip line and embedded spiral configuration stubs to reduce the electrical length of an open circuit at the slotline end point. For validating the microstrip-slotline technique, we have simulated and implemented the power divider with embedded spiral and via hole configuration circuits at a frequency of 2 GHz. Good agreement between the simulation and the measurement results is obtained at the operating frequency.

Effect of internal stress on cyclic fatigue failure in .06 taper ProFile (내부 응력이 .06 taper ProFile의 피로 파절에 미치는 영향)

  • Jung, Hye-Rim;Kim, Jin-Woo;Cho, Kyung-Mo;Park, Se-Hee
    • Restorative Dentistry and Endodontics
    • /
    • v.37 no.2
    • /
    • pp.79-83
    • /
    • 2012
  • Objectives: The purpose of this study was to evaluate the relation between intentionally induced internal stress and cyclic fatigue failure of .06 taper ProFile. Materials and Methods: Length 25 mm, .06 taper ProFile (Dentsply Maillefer), and size 20, 25, 30, 35 and 40 were used in this study. To give the internal stress, the rotary NiTi files were put into the .02 taper, Endo-Training-Bloc (Dentsply Maillefer) until auto-stop by torque controlled motor. Rotary NiTi files were grouped by the number of induced internal stress and randomly distributed among one control group and three experimental groups (n = 10, Stress 0 [control], Stress 1, Stress 2 and Stress 3). For cyclic fatigue measurement, time for separation of the rotary NiTi files was recorded. The fractured surfaces were observed by field emission scanning electron microscope (FE-SEM, SU-70, Hitachi). The time for separation was statistically analyzed using two-way ANOVA and post-hoc Scheffe test at 95% level. Results: In .06 taper ProFile size 20, 25, 30, 35 and 40, there were statistically significant difference on time for separation between control group and the other groups (p < 0.05). Conclusion: In the limitation of this study, cyclic fatigue failure of .06 taper ProFile is influenced by internal stress accumulated in the files.

Fast Self-Similar Network Traffic Generation Based on FGN and Daubechies Wavelets (FGN과 Daubechies Wavelets을 이용한 빠른 Self-Similar 네트워크 Traffic의 생성)

  • Jeong, Hae-Duck;Lee, Jong-Suk
    • The KIPS Transactions:PartC
    • /
    • v.11C no.5
    • /
    • pp.621-632
    • /
    • 2004
  • Recent measurement studies of real teletraffic data in modern telecommunication networks have shown that self-similar (or fractal) processes may provide better models of teletraffic in modern telecommunication networks than Poisson processes. If this is not taken into account, it can lead to inaccurate conclusions about performance of telecommunication networks. Thus, an important requirement for conducting simulation studies of telecommunication networks is the ability to generate long synthetic stochastic self-similar sequences. A new generator of pseu-do-random self-similar sequences, based on the fractional Gaussian nois and a wavelet transform, is proposed and analysed in this paper. Specifically, this generator uses Daubechies wavelets. The motivation behind this selection of wavelets is that Daubechies wavelets lead to more accurate results by better matching the self-similar structure of long range dependent processes, than other types of wavelets. The statistical accuracy and time required to produce sequences of a given (long) length are experimentally studied. This generator shows a high level of accuracy of the output data (in the sense of the Hurst parameter) and is fast. Its theoretical algorithmic complexity is 0(n).

A Study on a Multi Location Awareness Base on CSS(Chirp Spread Spectrum) (CSS기반 다중 위치인식 시스템에 관한 연구)

  • Yang, Jin-Uk;Cho, Seung-Soo;Yang, Seung-Hyun;Kang, Jun-Gil
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.7 no.5
    • /
    • pp.106-121
    • /
    • 2008
  • In this paper, we proposed and designed the protocol for energy efficiency and the center of data aiming at the design of a Multi Location Awareness System that recognizes a shadow site in parking and tunnel, which stands on the basis of CSS(Chirp Spread Spectrum) method using ISM Band of IEEE 802.15.4a that aware close location with wireless RF only. As a result of the protocol measurement, it displays the observation errors of less than 15cm, the data error rate of less than 5%, and can implement the Multi Location Awareness System with maximum length of life for 13.5 days using battery of 3V(1500 mAh).

  • PDF

Fabrication of the catalyst free GaN nanorods on Si grown by MOCVD

  • Ko, Suk-Min;Cho, Yong-Hoon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.232-232
    • /
    • 2010
  • Recently light emitting diodes (LEDs) have been expected as the new generation light sources because of their advantages such as small size, long lifetime and energy-saving. GaN, as a wide band gap material, is widely used as a material of LEDs and GaN nanorods are the one of the most widely investigated nanostructure which has advantages for the light extraction of LEDs and increasing the active area by making the cylindrical core-shell structure. Lately GaN nanorods are fabricated by various techniques, such as selective area growth, vapor-liquid-solid (VLS) technique. But these techniques have some disadvantages. Selective area growth technique is too complicated and expensive to grow the rods. And in the case of VLS technique, GaN nanorods are not vertically aligned well and the metal catalyst may act as the impurity. So we just tried to grow the GaN nanorods on Si substrate without catalyst to get the vertically well aligned nanorods without impurity. First we deposited the AlN buffer layer on Si substrate which shows more vertical growth mode than sapphire substrate. After the buffer growth, we flew trimethylgallium (TMGa) as the III group source and ammonia as the V group source. And during the GaN growth, we kept the ammonia flow stable and periodically changed the flow rate of TMGa to change the growth mode of the nanorods. Finally, as the optimization, we changed the various growth conditions such as the growth temperature, the working pressure, V/III ratio and the doping level. And we are still in the process to reduce the diameter of the nanorods and to extend the length of the nanorods simultaneously. In this study, we focused on the shape changing of GaN nanorods with different growth conditions. So we confirmed the shape of the nanorods by scanning electron microscope (SEM) and carried out the Photoluminescence (PL) measurement and x-ray diffraction (XRD) to examine the crystal quality difference between samples. Detailed results will be discussed.

  • PDF