Browse > Article

Determination of Aluminum Leached from Cooking Utensils by using Flow Injection Analysis  

Choi, Yong Wook (The School of Science and Technology, Jeonju University)
Publication Information
Abstract
Optimal analytical conditions have been established for mixing and reaction coil length, concentrations of ECR, CTAB, and acetate, reaction temperature and pH in the determination of aluminum by using flow injection analysis(FIA). Detection limit and repeatability for this system were $3{\mu}g/L$ and better than 1% of relative standard deviation, respectively. The interference from iron(III) was suppressed up to 6mg/L of iron(III) by $0.1{\mu}M$ ascorbic acid, and the interference from fluoride could be tolerated in absorption of Al/ECR/CTAB derivative by 10mM boric acid at pH 3.5 adjusted with nitric acid. This FIA system was applied to the determination of aluminum leached from cooking utensils by distilled and tap water containing fluoride ranged from 0.5 to 2mg/L by measurement of absorbance for Al/ECR/CTAB at 585nm. The leached aluminum content was increased with increasing concentration of fluoride. The aluminum contents leached from aluminum utensils by tap water were about 9 fold higher than those leached by distilled water, whereas aluminum contents leached by distilled water containing fluoride were about 2 fold higher compared to those leached by distilled water. That represented that other dissolved substances as well as fluoride in tap water contributed to liberation of aluminum from aluminum utensils. A comparison between FIA data and ICP-AES data by correlation and paired t test showed that the FIA system could be accepted as a good alternative method for the determination of aluminum in tap water.
Keywords
FIA; ECR; CTAB; Aluminum; Cooking utensils; Tap water;
Citations & Related Records
연도 인용수 순위
  • Reference
1 김종훈, 최용욱, 정택균, 단일 컬럼이온크로마토그래피에 의한 광천수중 음이온의 신속한 동시 정량, 대한화학회지, 39(12), pp. 910-917 (1995)
2 김종훈, 최용욱, 정택균, 삼중수소 측정에 의한 약수터물의 수질특성 연구, 대한화학회지, 40(6), pp. 436-444 (1996)
3 김중만, 한성희, 백승화, 조리시 조리용기로부터의 알루미늄 용출량 비교, 한국식품과학회지, 29(4), pp. 613-617 (1997)
4 Borrmann, G., and Seubert, A., Aluminum speciation by means of anion chromatography and coupled anion/cation chromatography, Anal. Chim. Acta, 386, pp. 77-88 (1999)
5 Cathalifaud, G., and Mazet, J. A. M., Aluminium ions/organic molecules complexation: Formation constants and stoichiometry. Application to drinking water production, Wat. Res., 31(4), pp. 689-698 (1997)
6 D'Ulivo, A.; Lampugnani, L.; Faraci, D.; Tsalev, D. L., and Zamboni, Z., Elimination of hydrofluoric acid interfernce in the determination of antimony by the hydride genetation technique, Talanta, 45, pp. 801-806 (1998)
7 Haidouti, C., Effect of fluoride pollution on the mobilization and leaching of aluminum in soil, Sci. Total Environ., 166, pp.157-160 (1995)
8 Kato, Y. T., Yoshida, K., Fujimori, E., Haraguchi, H., Shimizu, Y., and Kondo Analysis of elements of hydrangea sepals at varios growing stages by ICP-AES, Biochem. Engineer. J., 14, pp. 237-241 (2003)
9 Radic, N., and Bralic, M., Aluminium fluoride complexation and its ecological importance in the aquatic environment, Sci. Total Environ, 172, pp. 237-243 (1995)
10 Rojas, F. S., Alcaraz, E. C., and Pavon, J. M., Determination of aluminum in water by flow injection with fluorimetric detection by using salicyaldehyde carbohydrazone as reagent in a micellar medium, Analyst, 119, pp. 1221-1223 (1994)
11 Royset, O., Comparison of four chromogenic reagents for the flow injection determination of aluminium in water, Anal. Chim. Acta, 178, pp. 223-230 (1985)
12 Umemura, T., Usami, Y., Aizawa, S., Tsunoda, K., and Satake, K., Seasonal change in the level and the chemical forms of aluminum in soil solution under a Japanese cedar forest, Sci. Total Environ., 317, pp. 149-157 (2003)
13 Wang, H., Zhang, Z., Sun, A., Liu, D., and Liu, R., Stopped-flow kinetic determination of aluminum in Chineses tea leaves by fluoride ion-selective electrode potentiometry, Talanta, 43, pp. 2067-2072 (1996)
14 Zhang, J., Xu, H., and Ren, J. L., Fluorimetric determination of dissolved aluminium in natural waters after liquid-liquid extraction into n-hexanol, Anal. Chim. Acta, 405, pp. 31-42 (2000)
15 Coscione, A. R., Andrade, J. C., Poppi, R. J., Mello, C., Raij, B., and Abreu, M. F., Multivariate calibration applied to a highly interfering chemical system-The simultaneous spectrophotometric determination of aluminium and iron in plants using xylenol orange and partial least-squares regression, Anal. Chim. Acta, 423, pp. 31-40 (2000)
16 Zhu, R., Kok, W. Th., Determination of trace metal ions by capillary electrophoresis with fluorescence detection based on post-column conplexation with 8-hydroyquinoline-5-sulphonic acid, Anal. Chim. Acta, 371, pp. 269-277 (1998)
17 Lemberkovics, E., Czinner, E., Szentmihalyi, K., Balazs, A., and Szoke, E., Comparative evaluation of Helichrysi flos herbal extracts as dietary sources of plant polyphenols, and macro- and microelements, Food Chem., 78, pp. 119-127 (2002)
18 최용욱, 진재영, 흐름주입분석법에 위한 음용수 중 알루미늄이온의 분광광도법 정량, 대한화학회지, 44(5), pp. 422-428 (2000)
19 Wong, M. H., Fung, K. F., Carr, H. P., Aluminium and fluoride contents of tea, and their health implications, Toxicalogy Letters, 137, pp. 111-120 (2003)
20 Lu, X., Chen, Z., and Yang, X., Spectroscopic study of aluminum speciation in removing humic acid substance by Al coagulation, Wat. Res., 33(15), pp. 3271-3280 (1999)
21 Neelam, Bamji, M. S., and Kaladhar, M., Risk of increased aluminium burden in the Indian population: contribution from aluminium cookware, Food Chem., 70, pp. 57-61 (2000)
22 Ruzicka, J. and Hansen, E. H., Flow injection analyses, Part I. A new concept of fast continuous flow analysis, Anal. Chim. Acta, 78, pp. 145-157 (1975)
23 Scancar, J., Stibilj, V., and Milacic, S. R., Determinaion aluminiun in Slovenian foodstuffs and its leachability from aluminium-cookware, Food Chem., 85, pp. 151-157 (2004)
24 Harris, D. C. Quantitative Chemical Analysis, 4th. Ed., Freeman and Co., New York, Chap. 4 (1995)
25 먹는 물 수질공정시험방법, 환경부 (2000)
26 Exley, C., Pinnegar, J. K., and Taylor, H., Hydroxy-aluminosilicates and acute aluminium toxicity in fish, J. theor. Biol. 189, pp. 133-139 (1997)
27 Takatsu, A., Ezoe, Y., Eyama, S., Uchiumi, A., Tsunoda, K., and Satake, K., Aluminum in lake water and organs of a fish Tribolodon hakonensis in strongly acidic with a high aluminum concentration, Limnology, 1, pp. 185-189 (2000)
28 김명선, 한재숙, 南出降久, 알루미늄 조리기구에서 산성조미료와 조리조건이 알루미늄 용출에 미치는 영향, 대한가정학회지, 38(2), pp. 21-26 (2000)   과학기술학회마을
29 Chester, J. E.; Dagnall, R. M., and West, T. S., An improved reagent system for the spectrophotometric determination of aluminium, Talanta, 17, pp. 13-19 (1970)
30 Bi, S., A model describing the complexing effect in the leaching of aluminum from cooking utensil, Environ. Pollut., 92(1), pp. 85-89 (1996)
31 Flaten, T. P., Aluminium as a risk factor in Alzheimer's disease, with emphasis on drinking water, Brain Res. Bull., 55(2), pp. 187-196 (2001)
32 Skoog, D. A., Holler, F. J., and Nieman, T. A., Principles of Instrumental Analysis, 5th Ed., Harcourt Brace College Publishers; Philadelphia, USA, Chap. 15 (1998)
33 Nishimoto, J., Yamada, T., and Tabata, M., Solvent extraction and fluorometric determination of fluoride ion at ppb level in the presence of large excess aluminum(III) and iron(III) by using an expanded porphyrin, sapphyrin, Anal. Chim. Acta, 428, pp. 201-208 (2001)