• Title/Summary/Keyword: length measurement

Search Result 2,201, Processing Time 0.025 seconds

Fabrication of X-ray monocapillary optics for soft X-ray fluorescence analysis (경 X선 형광분석을 위한 모세관 광학소자 제작)

  • Cho, Hyung-Wook;Park, Byung-Hoon;Kim, Yong-Min;Choi, Chul-Hee;Choi, Seong-Hee;Kim, Ki-Hong;Chon, Kwon-Su
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.6
    • /
    • pp.409-413
    • /
    • 2011
  • An X-ray tube used an X-ray fluorescence analysis system has a low X-ray photon intensity which results in reducing measurement accuracy and increasing exposure time. These shortages can be overcame by using a monocapillary optics. A monocapillary optics was optimally designed for focusing the characteristic X-ray of tungsten (8.4 keV). The monocapillary optics can achieve a gain of 10 at the least. The monocapillary optics was fabricated by using puller and pyrex glass, raw material. In fabrication, a weigh of 45g and a temperature of $650^{\circ}$ was loaded. The total fabrication time was 460 minutes. The fabricated capillary had 87 mm in length and maximum diameter of 300 ${\mu}m$ and minimum diameter of 192 ${\mu}m$. When the fabricated monocapillary optics is applied to an X-ray fluorescence analysis system, the detection accuracy for soft elements, for example sulfur (S), will be improved.

Characterization of a Micro Power Generator using a Fabricated Electroplated Coil (전기도금 방법으로 제작한 코일을 이용한 초소형 발전기의 특성분석)

  • Lee, Dong-Ho;Kim, Seong-Il;Kim, Young-Hwan;Kim, Yong-Tae;Park, Min-Chul;Lee, Chang-Woo;Baek, Chang-Wook
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.13 no.3 s.40
    • /
    • pp.9-12
    • /
    • 2006
  • We have designed and fabricated micro power generators by electroplating which is important in MEMS(micro electro mechanical system) technique. We have electroplated MEMS coils on the glass substrates and have chosen one of these coils for experiments. The thickness, width, and length of the coil are $7{\mu}m,\;20{\mu}m$, and 1.6 m, respectively. We have analyzed the structure of MEMS coil by SEM. We have made a vibrating system for reproducible results in measurement. With reciprocating a magnet on the surface of a fabricated winding coil, the micro power generator produce an alternating voltage. We have changed the vibrational frequency from 0.5 Hz to 8 Hz. The generated voltage was 106 mV at 3 Hz and 198 mV at 6 Hz. We aim at the micro power generator which can change vibration energy to useful electric energy.

  • PDF

Evaluation of Half Cell Potential Measurement in Cracked Concrete Exposed to Salt Spraying Test (염해에 노출된 균열부 콘크리트의 반전위 평가)

  • Kim, Ki-Bum;Park, Ki-Tae;Kwon, Seung-Jun
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.6
    • /
    • pp.621-630
    • /
    • 2013
  • Several techniques for steel corrosion detection are proposed and HCP (half cell potential) technique is widely adopted for field investigation. If concrete has cracks on surface, steel corrosion is rapidly accelerated due to additional intrusion of chloride and carbon dioxide ions. This study is for an evaluation of HCP in cracked concrete exposed chloride attack. For this work, RC (reinforced concrete) beams are prepared considering 3 w/c ratios (0.35, 0.55, and 0.70) and several cover depths (10~60 mm) and various crack widths of 0.0~1.0 mm are induced. For 35 days, SST (salt spraying test) is performed for corrosion acceleration, and HCP and corrosion length of rebar are evaluated. With increasing crack width, w/c ratios, and decreasing cover depth, HCP measurements increase. HCP evaluation technique is proposed considering the effects of w/c ratios, crack width, and cover depth. Furthermore anti-corrosive cover depths are obtained through Life365 program and the results are compared with those from this study. The results shows relatively big difference in cracked concrete, however provide similar anti-corrosive conditions in sound concrete.

Radio Frequency Circuit Module BGA(Ball Grid Array) (Radio Frequency 회로 모듈 BGA(Ball Grid Array) 패키지)

  • Kim, Dong-Young;Jung, Tae-Ho;Choi, Soon-Shin;Jee, Yong
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.37 no.1
    • /
    • pp.8-18
    • /
    • 2000
  • We presented a BGA(Ball Grid Array) package for RF circuit modules and extracted its electrical parameters. As the frequency of RF system devices increases, the effect of its electrical parasitics in the wireless communication system requires new structure of RF circuit modules because of its needs to be considered of electrical performance for minimization and module mobility. RF circuit modules with BGA packages can provide some advantages such as minimization, shorter circuit routing, and noise improvement by reducing electrical noise affected to analog and digital mixed circuits, etc. We constructed a BGA package of ITS(Intelligent Transportation System) RF module and measured electrical parameters with a TDR(Time Domain Reflectometry) equipment and compared its electrical parasitic parameters with PCB RF circuits. With a BGA substrate of 3${\times}$3 input and output terminals, we have found that self capacitance of BGA solder ball is 68.6fF, and self inductance 146pH, whose values were reduced to 34% and 47% of the value of QFP package structure. S11 parameter measurement with a HP4396B Network Analyzer showed the resonance frequency of 1.55GHz and the loss of 0.26dB. Routing length of the substrate was reduced to 39.8mm. Thus, we may improve electrical performance when we use BGA package structures in the design of RF circuit modules.

  • PDF

Implementation about measurement of the head SAR and variable parameter according to operation control mode in brain MR study with 1.5Tesia (1.57 BRAIN MRI검사에서의 작동제어모드를 통한 두부 SAR측정과 변화인자에 관한 고찰)

  • Lee, Kyu-Su;Sim, Hyun;Moon, Ji-Hoon;Oh, Jae-Cheol
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.58-60
    • /
    • 2007
  • Magnetic Resonance Imaging(MRI) has become a very widely used medical procedur e. Clo.sed and open systems are typically used with static magnetic fields at or below 2 Tesla. BWhole body SAR(specific absorbsion rate) is the value of SAR averaged over the entire body of the patient over any period of 15 minutes. Head SAR is the value of SAR averaged over the head of the patient for any period of 10 minutes. SAR is a measure of the absorption of electromagnetic energy in the body' (typically in watts per kilogram (W/kg)). The normal operating mode comprises values of head SAR not higher than 3 W/kg. The second level controlled operating mode comprises values higher than 3 W/kg. Current FDA guidance limits the SAR in the whole body. including the head to a range of 1.5 to 4.0 W/kg, depending on the patient's clinical condition. SAR, limit restrictions are incorporated in all MRI systems. and domestic' s guidance limits the SAR in a part body. including the head to 3.2w/kg and less. The purpose of this study is to evaluate on change of head SAR in using MRI pulse sequence and to check if exceed 3.2(w/kg) level in domestic a part exposure through measured head SAR. 23 patient's the average head SAR of pulse sequence is that T2WI sagittal is 0.5375. T2WI axial(FSE) is 0.4817, T1WI axial(SE) is, 0.8179. FLAIR axial is 0.4580. GRE axial is 0.0077, Diffusion is 0.0824w/kg. The head SAR exposed per patient was proved 2.3845w/kg less than the international standard. Coefficient of correlation for the relations body weight and SAR or for the relations ETL(echo train length) and SAR is 1 value. Coefficient of correlation for the relations between TR(time to repeat) and SAR is -0.602 value. so SAR increased relative to weight body and ETL. But the relations between TR and SAR is negative definite.

  • PDF

Effects on Labor Pain and Length of Delivery Time for Primipara Women treated by San-Yin-Jian(SP-6) Acupressure and Hob-Gog(LI-4) Acupressure (산부의 삼음교(SP-6).합곡(LI-4)지압이 분만통증과 분만소요시간에 미치는 효과)

  • Kim, Young-Ran;Chang, Soon-Bok;Lee, Mi-Kyeong;Maeng, Woong-Jaeg
    • Women's Health Nursing
    • /
    • v.8 no.2
    • /
    • pp.244-256
    • /
    • 2002
  • The purpose of this study was to examine the effects on labor pain and duration of delivery time for primipara women treated by San-Yin-Jiao(SP-6) and Hob-Gog(LI-4) acupressure. The design of this study was a nonequivalent control group non-synchronizedpost test only design. It was done to identify the effects of SP-6 acupressure or LI-4 acupressure on labor pain in primipara women. The benefits of using SP-6 acupressure or LI-4 acupressure were evaluated by comparing three groups, a SP-6 acupressure group, a LI-4 acupressure group and a control group, not treated with acupressure. The participants included 192 primiparas who underwent vaginal delivery, 72 primiparas in the control group, 71 in the SP-6 acupressure group and 49 in the LI-4 acupressure group. Data were collected using a structured questionnaire consisting of general characteristics, a subjective labor pain scale (Johnson, 1974), and measurement of duration of delivery time. The results of this study are summarized as follows : 1. Differences in the acupressure effect for SP-6 and LI-4 were analyzed using Scheffe's test which showed that differences in the control group vs the SP-6 group and the control group vs the LI-4 group were statistically significant (t=21.767, p<0.05; t=23.923, p<0.05), but the SP-6 group vs the LI-4 group showed no significant differences. 2. The duration of delivery time in the group which had SP-6 acupressure or LI-4 acupressure was shorter (400.77${\pm}$153.34; 379.10${\pm}$127.60) than in the control group (528.68${\pm}$239.08). Differences in the effects of acupressure with SP-6 and LI-4 were also analyzed by Scheffe's test. Control group vs SP-6 group and Control group vs LI-4 group were significantly different(t=127.91, p<0.05; t=149.58, p<0.05), but the SP-6 group vs the LI-4 group did not show any statistically significant difference (t=21.67). This study has shown that SP-6 and LI-4 acupressure were both effective in relation to labor pain and duration of delivery time for primiparas. But it is necessary to replicate the study with a larger number of participants to generalize of the results.

  • PDF

Selection response and estimation of the genetic parameters for multidimensional measured breast meat yield related traits in a long-term breeding Pekin duck line

  • Xu, Yaxi;Hu, Jian;Zhang, Yunsheng;Guo, Zhanbao;Huang, Wei;Xie, Ming;Liu, Hehe;Lei, Chuzhao;Hou, Shuisheng;Liu, Xiaolin;Zhou, Zhengkui
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.31 no.10
    • /
    • pp.1575-1580
    • /
    • 2018
  • Objective: This study was conducted to estimate the genetic parameters and breeding values of breast meat related traits of Pekin ducks. Selection response was also determined by using ultrasound breast muscle thickness (BMT) measurements in combination with bosom breadth (BB) and keel length (KL) values. Methods: The traits analyzed were breast meat weight (BMW), body weight (BW), breast meat percentage (BMP) and the three parameters of breast meat (BB, KL, and BMT). These measurements were derived from studying 15,781 Pekin ducks selected from 10 generations based on breast meat weight. Genetic parameters and breeding value were estimated for the analysis of the breeding process. Results: Estimated heritability of BMW and BMP were moderate (0.23 and 0.16, respectively), and heritability of BW was high (0.48). Other traits such as BB, KL, and BMT indicated moderate heritability ranging between 0.11 and 0.28. Significant phenotypic correlations of BMW with BW and BMP were discovered (p<0.05), and genetic correlations of BMW with BW and BMP were positive and high (0.83 and 0.66, respectively). It was noted that BMW had positive correlations with all the other traits. Generational average estimated breeding values of all traits increased substantially over the course of selection, which demonstrated that the ducks responded efficiently to increased breast meat yield after 10 generations of breeding. Conclusion: The results indicated that duck BMW had the potential to be increased through genetic selection with positive effects on BW and BMP. The ultrasound BMT, in combination with the measurement of BB and KL, is shown to be essential and effective in the process of high breast meat yield duck breeding.

A Study on the Measurement of Physical Properties for Miscellaneous Cereal Crops Sorting (잡곡 선별을 위한 물성 측정에 관한 연구)

  • Kim, Hoon;Lee, Hyo-Jai;Han, Jae Woong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.10
    • /
    • pp.354-360
    • /
    • 2020
  • This study examined the factors for sorting miscellaneous cereal crops using a rice-sorting device by analyzing the physical characteristics according to the moisture content. The initial moisture contents of miscellaneous cereal were 16.3, 19.8, and 16.5%, respectively. The samples were used in the experiment after drying to five levels. The width, length, and area of the samples increased with increasing moisture content except for the roundness, and all the prediction models were developed with a first-order linear equation. The bulk density of Italian millet and sorghum increased with increasing moisture content, whereas the bulk density of common millet was unaffected by the change in moisture content. The terminal velocity of the samples increased with increasing moisture content, and a first-order linear equation was used to develop the prediction models. The measured physical properties of the miscellaneous cereal crops based on the changes in the moisture content could be expressed using a first-order experimental model equation. Therefore, the rice-sorting device could be applied to the terminal velocity, but the other device applying the geometrical characteristics and bulk density was required to change the design of the process depending on the type of grain.

The Analysis of Exercise Therapy in Nursing Research (운동중재에 관한 국내 간호학 논문 분석)

  • 전점이
    • Journal of Korean Academy of Nursing
    • /
    • v.30 no.2
    • /
    • pp.319-330
    • /
    • 2000
  • This study is aimed at analyzing the trend of research on the use of exercise in nursing research, through suggesting directions for future research and implementation of the various exercise therapies. Research studies were taken from dissertations and theses selected from the Academic Society Journals of nursing science, Journals from universities, medical and nursing schools, research institutes in various universities, the Central Journal of Medicine, and the New Medical Journal. The research published between 1970 and 1997 in Korea were analyzed, 51 research were selected. The research are analyzed according to: published time, source of the research, research design, subjects, sample size, dependant variables, exercise therapy, and effect of exercise therapy. The results were as follows: 1. Research on exercise therapy increased rapidly in the 1990's. At this time, 88.2% of research was published. 2. Research areas included: 54.9% non- degree research, 27.5% Doctoral theses, and 17.6% Master's theses. 3. The experimental design included: 66.7% non- equivalent control group pre-test/ post-test design and 29.4% one group pre-test/post- test design. 4. Out of the Subjects: 52.9% were patients with various health problems, and 47.1% were healthy individuals. 5. Sample size included: 52.9% with above 31 subjects, 11.8% with 11~15 and 26~30. 6. Exercise therapy was analyzed by type, intensity, frequency, duration, and period. 1) The Types: Aerobic exercise at 60.8% was the most common, active exercise for muscle strengthening and building made up 21.6%. 2) Exercise with 40~65% intensity comprised 25.5%, 70~85% with 7.8%, and no description of the intensity was 66.7%. 3) Frequency of 3~5 per week was the most common at 78.4%. 4) Duration: 15~60 minutes was the most common length of time at 76.5%. 5) Periods: More than 5 weeks at 82.3% were the most common in their categories. 7. Dependant variables: Psychological response was measured as a dependant variable in 92.2%, Cardio-pulmonary function 88.2%, Body Composition was 86.3%, Physical Response was 60.8%, Lipid Metabolism was 58.8%, Physical Strength was 49.0%, Glucose Metabolism was 25.5%, Activities of Daily Living was 17.6% and others added to be 3.9%. 8. The effect of Exercise Therapy was categorized into 'positive', 'partially positive', and 'no effect' according to dependant variables: Having a positive effect - Glucose Metabolism (93.3%), Physical Response (85.0%), Activities of Daily Living (81.8%), Psychological Response (71.6%), Lipid Metabolism (67.6%), Cardio- pulmonary Function (63.6%), Physical Strength (68.1%), and Body Composition (56.4%). The following suggestions can be made on the above findings: 1. Research findings on Exercise Therapy as a Nursing Intervention need to be described by their elements of type, intensity, frequency, duration and period. 2. Toproperly study the positive effects of Exercise Therapy, there needs to be ⑴ appropriate research design, ⑵ selection criteria for the subjects ⑶ contents of exercise prescription to individuals or groups ⑷ measurement criterion for the dependent variables. 3. Meta-analysis on exercise therapy also needs to be done to analyze and integrate the various results.

  • PDF

A Study on the Nutrient Intakes and Zinc Nutritional Status of Preschool Children in Ulsan (울산지역 유치원 어린이의 <한국인영양섭취기준>에 의한 영양소섭취 실태 및 아연영양 상태에 관한 연구)

  • Yu, Kyeong-Hee
    • Journal of Nutrition and Health
    • /
    • v.40 no.4
    • /
    • pp.385-394
    • /
    • 2007
  • The purpose of this study was to determine the zinc status of preschool children in Ulsan. The study was conducted in 95 children aged 3 to 6 years by investigating the anthropometric indices and assessing the biochemical analysis. The blood was analysed to assess serum zinc and alkaline phosphatase. And a questionnaire for dietary intakes using 24-hr recall method were performed by mothers of 95 subjects. The dietary intakes of children were analysed to determine the prevalence of inadequate and excessive intakes of zinc with Dietary Reference Intakes for Koreans (KDRIs). WHL (Weight-Length Index) and Kaup index were used to define obesity. The overall prevalence of overweight and obese subjects were 14.7% and 6.3% by WHL, were 15.8% and 13.7% by Kaup index. The mean intakes of zinc by children aged 3${\sim}$5y and 6y were 5.5 ${\pm}$ 1.4 mg/d (75.7% RDA) and 6.7 ${\pm}$ 2.0 mg/d, respectively, that was the level exceeding the estimated average requirement (EAR) and the recommended intake (RI) of Korean Dietary Reference Intakes. Less than 1.3% and 7.9% of children had usual zinc intakes below EAR and RI of KDRIs, respectively. The percentages of children with intakes exceeding the tolerable upper intake level (UL) were 2.6%. The zinc nutritional status by biological assay was found that mean serum zinc and alkaline phosphatase (ALP) of total subjects were 64.0 ${\pm}$ 8.4 ${\mu}$g/dl and 72.8 ${\pm}$ 14.9 U/L, there was not a significant difference between boys and girls. The range of serum zinc level was 45${\sim}$89 ${\mu}$g/dl and children with a low serum zinc concentration by several cut-off points were 18.9${\sim}$55.8%, especially. Serum zinc level was positively correlated to the intakes of calorie, calcium, fiber, iron, zinc, zinc/kg and height (p<0.001). Serum ALP was positively correlated height, weight and WLI. The zinc intake of children aiso showed a positive correlation with height and weight. These results indicate that there were significant correlations between the zinc status and growth of preschool children. Preschool children in Ulsan have dietary zinc intakes that exceed the new DRIs. The present level of intake does not seem to pose a health problem, but if zinc intakes with fortified foods and supplements were considered, the amount of zinc consumed by children may become excessive.