• Title/Summary/Keyword: length measurement

Search Result 2,195, Processing Time 0.035 seconds

An Experimental Study on Development of the Opening Apparatus for Oil Boom (오일펜스 전개장치 개발에 관한 실험적 연구)

  • Jang Duck-Jong;Na Sun-Chol
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.9 no.1
    • /
    • pp.45-54
    • /
    • 2006
  • The study was to review methods by which a ship can unfold and tow an oil boom by attaching the opening apparatus to an oil boom through experiments. The shape and dimension of the opening apparatus were designed with the measurement value of the towing tension load of the oil boom and the dimension of winch drum of the oil boom installed in the ship considered. For the field experiment to identify the performance of the opening apparatus, opening apparatuses were prepared to have the dimension of $3.0m^2$ and $6.0m^2$ which is 91% and 75% of the calculation value for type B and C respectively. As a result, T(kg), the value of tension in type B oil boom according to the towing speed(v) change when two ships are towed together were proved to be $T=920v^{1.1}\;and\;T=500v^{0.9}$ in case the distance is 100 m and 50 m. Based on the result, the dimension of the opening apparatus for type B and C oil boom was calculated as $3.3m^2$ and $8.0m^2$ respectively. When unfolding and towing by attaching the opening apparatus and 200 m of towing line at both ends of type B and type C oil boom, the maximum width of the opening apparatus was shown as 114 m and 95 m in average(width of opening/total length of oil boom: 33% and 57%) in the towing speed of 1.5 kt. It was evaluated that the opening apparatus could concentrate the spilled oil in a good performance. However as far as the increase rate of oil boom opening width according to the length of the towing line is debatable, the increase rate is remarkably reduced when it is lengthened from 100 m to 150 m and to 200 m although it showed extreme increase of 31% and 40% when the length of the towing line was changed from 50 m to 100 m. Therefore, it is inferred that the towing line should be maintained more or less 100 m to get good spread efficiency of the opening apparatus. Additionally, if the towing speed is faster than 1.5 kt, the opening width was narrowed because of the reduced spread efficiency and the shape of the oil boom can be unstable because of the partial sinking of the oil boom, run over waves, or flap of skirt. Thus the reasonable towing speed can be within 1.5 kt for the operation of the opening apparatus.

  • PDF

A Study on the Social Capital of Marriage Immigrant Women : focused on the neighbourhood community of Filipino immigrant women (결혼이주여성의 사회자본에 관한 연구 - 필리핀 결혼이주여성의 근린공동체를 중심으로 -)

  • Kim, Yeong Kyeong;Lee, Jung Hyang
    • Journal of the Korean association of regional geographers
    • /
    • v.20 no.2
    • /
    • pp.163-175
    • /
    • 2014
  • This study is to explain social capital characteristics of Filipino immigrant women at the level of neighborhood. This research targeted Filipino immigrant women in the metropolis, small town and rural area in Korea to find out the relevance of individual property and characteristics of the community and social capital of neighboring communities- school community, cathedral community, etc- through measurement of the participants' recognition. This study reveals that differences exist in the relationship between length of residence and social capital in the school community and the catholic church community. There is a significant positive relationship between length of residence and political factors in the catholic church community, thereby having a better relationship with longer period of stay, while length of residence and confidence show a negative trend in the school community, leading to less confidence. The catholic church community holds a dominant position in homogeneity, cohesion, and the amount of social capital. According to the findings, social capital 'relation' is more closely related to homogeneity of the community, 'norms' to cohesion. 'Relation and norms' and 'confidence and politics' factors are recognized similarly in both communities, thus resulting in the recognition that decision making within the community, the share of value, and observance of social norms approximate a friendly relationship among members, and satisfaction level, emotional support, and confidence among members approach politics that members can talk about their personal matters. It is noted in the research process that the symbolism of the cathedral community as a transnational circuit behavior occurs where collective culture and personal desires of Filipino immigrant women were combined with production of social capital. Filipino immigrant women's awareness of community and social capital appearing in the cathedral community show that not only residence, along with the cultural identity of Filipino immigrant women, but also collective social and cultural characteristics, such as 'family reunion' can not be overlooked. In particular, at this time when discussion and debate on the interculturalism over multiculturalism is heating up, communal spirit and social capital based on the ethnic identity are important in that they can be a crucial path to the cross-cultural interaction with our society, therefore, a study on the social capital of the ethnic community needs to be encouraged and extended to more diverse communities, to the space of the multilayered scale.

  • PDF

Application of the Equivalent-Field Method for Output Calculation: Is it safe for elongated x-ray fields\ulcorner (출력인자 계산에 이용되는 등가면법의 타당성 연구 : 장방형 X-선 조사면에 대해서 안전한가\ulcorner)

  • Kim, Chang-Seon;Kim, Chul-Yong;Park, Myung-Sun
    • Progress in Medical Physics
    • /
    • v.9 no.4
    • /
    • pp.195-200
    • /
    • 1998
  • Purpose: When an elongated x-ray field is used for treating a patient, the equivalent- field method is commonly used for the output calculation. This study is intended for investigating potential factors such as, beam quality, field elongation ratio, and depth of measurement, which might effect on the applicability of the equivalent square technique for output calculation. The derivation of a 'rule of thumb' for the application criteria of the equivalent-field method is also aimed. Materials and Methods: Three x-ray beams, 4-, 6- and 10-MV, were employed for this study. Width of the rectangular field was ranged from 5-40 cm and the elongation ratio (length/width) 1:0 to 10:0. An elongation effect was measured in a water phantom at three different depths, dmax, 5-cm, and 10-cm. For an elongated field and its equivalent square field, the output factor was measured and the difference in the output factor were examined between two fields. Results and Discussions: As the elongation ratio increases, a larger discrepancy in outputs is observed between the elongated rectangular field and its corresponding equivalent square field. Output was measured larger for an elongated field than for its corresponding equivalent square field and the maximal difference over 10 % was found. The difference was found larger for the smaller field with the same elongation ratio. The effect of the beam quality and the depth of measurement on the output difference was minimal. Conclusion: Based on the study, there is criteria for the application of the method for output calculation. For the combination of long axis and elongation ratio whose relationship satisfies Elongation ratio < (0.48) (Long axis) - 0.5, the equivalent-field method is valid for output calculation within 2 % for the field whose long axis < 25-cm. For other combinations, instead of using the equivalent-field method, direct output measurement is recommended. This criteria can be applied for 4-10 MV x-ray beams up to 10-cm depth.

  • PDF

Radiation Dose during Transmission Measurement in Whole Body PET/CT Scan (전신 PET/CT 영상 획득 시 투과 스캔에서의 방사선 선량)

  • Son Hye-Kyung;Lee Sang-Hoon;Nam So-Ra;Kim Hee-Joung
    • Progress in Medical Physics
    • /
    • v.17 no.2
    • /
    • pp.89-95
    • /
    • 2006
  • The purpose of this study was to evaluate the radiation doses during CT transmission scan by changing tube voltage and tube current, and to estimate the radiation dose during our clinical whole body $^{137}Cs$ transmission scan and high quality CT scan. Radiation doses were evaluated for Philips GEMINI 16 slices PET/CT system. Radiation dose was measured with standard CTDI head and body phantoms in a variety of CT tube voltage and tube current. A pencil ionization chamber with an active length of 100 mm and electrometer were used for radiation dose measurement. The measurement is carried out at the free-in-air, at the center, and at the periphery. The averaged absorbed dose was calculated by the weighted CTDI ($CTDI_w=1/3CTDI_{100,c}+2/3CTDI_{100,p}$) and then equivalent dose were calculated with $CTDI_w$. Specific organ dose was measured with our clinical whole body $^{137}Cs$ transmission scan and high quality CT scan using Alderson phantom and TLDs. The TLDs used for measurements were selected for an accuracy of ${\pm}5%$ and calibrated in 10 MeV X-ray radiation field. The organ or tissue was selected by the recommendations of ICRP 60. The radiation dose during CT scan is affected by the tube voltage and the tube current. The effective dose for $^{137}Cs$ transmission scan and high qualify CT scan are 0.14 mSv and 29.49 mSv, respectively. Radiation dose during transmission scan in the PET/CT system can measure using CTDI phantom with ionization chamber and anthropomorphic phantom with TLDs. further study need to be peformed to find optimal PET/CT acquisition protocols for reducing the patient exposure with same image qualify.

  • PDF

Study on Bandwidth and Characteristic Impedance of CWP3DCS (Coplanar Waveguide Employing Periodic 3D Coupling Structures) for the Development of a Radio Communication FISoC (Fully-integrated System on Chip) Semiconductor Device (완전집적형 무선통신 SoC 반도체 소자 개발을 위한 주기적인 3차원 결합구조를 가지는 코프레너 선로에 대한 대역폭 및 임피던스 특성연구)

  • Yun, Young
    • Journal of Navigation and Port Research
    • /
    • v.46 no.3
    • /
    • pp.179-190
    • /
    • 2022
  • In this study, we investigated the characteristic impedance and bandwidth of CPW3DCS (coplanar waveguide employing periodic 3D coupling structures), and examined its potential for the development of a marine radio communication FISoC (fully-integrated system on chip) semiconductor device. To extract bandwidth and characteristic impedance of the CPW3DC, we induced a measurement-based equation reflecting measured insertion loss, and compared the measured results of the propagation constant β and characteristic impedance with the measured ones. According to the results of the comparison, the calculated results show a good agreement with the measured ones. Concretely, the propagation constant β and characteristic impedance exhibited an maximum error of 3.9% and 6.4%, respectively. According to the results of this study, in a range of LT = 30 ~ 150 ㎛ for the length of periodic structures, the CPW3DC exhibited a passband characteristic of 121 GHz, and a very small dependency of characteristic impedance on frequency. We could realize a low impedance transmission line with a characteristic impedance lower than 20 Ω by using CPW3DCS with a line width of 20 ㎛, which was highly reduced, compared with a 3mm line width of conventional transmission line with the same impedance. The characteristic impedance was easily adjusted by changing LT. The above results indicate that the CPW3DC can be usefully used for the development of a wireless communication FISoC (fully-integrated system on chip) semiconductor device. This is the first report of a study on the bandwidth of the CPW3DC.

Chest CT Finding and Its Comparison with Bronchoscopic Finding in Endobronchial Tuberculosis (기관지결핵의 흉부전산화단층촬영소견 및 기관지경소견과의 비교)

  • Lee, Jae-Ho;Yoon, Hye-Kyung;Song, Jae-Woo;Yoo, Chul-Gyu;Chung, Hee-Soon;Kim, Young-Hwan;Han, Sung-Koo;Shim, Young-Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.4
    • /
    • pp.742-755
    • /
    • 1997
  • Background : Endobronchial tuberculosis(ET) is still relatively common disease in Korea. We intended to evaluate the length of endobronchial lesion, peribronchial thickness, luminal irregularity and associated mediastinal lymph node enlargement with Chest CT to get information for such aggressive treatment as electrocautery, laser therapy and so on of bronchial stricture in ET, and also to compare the change of Chest CT finding with that of bronchoscopic finding after one month of anti-tuberculosis treatment. Method : We performed CT in 26 patients who were diagnosed as ET by bronchoscopy at Boramae Hospital from November 1991 to March 1996. After classifying ET into seven subtypes according to bronchoscopic finding, we analyzed the CT finding of each subtype. And we followed up the bronchoscopy, CT, and PIT after one month of anti-tuberculosis treatment, and compared the change of CT findings with those of bronchoscopic findings in nine patients. Results : Age of the patients was from 17 to 73 years old, and the ratio of male to female was 1 : 25 with absolute female predominance. The site(s) of bronchial involvement by tuberculosis is one in 14 cases, two in nine cases and three in one case, respectively, and the left main bronchus was the most frequently involved site (13 cases for multiple involvements and 7 cases for single involvement among 26 cases). The length of bronchial involvement by tuberculosis which was measured by CT was from 10 to 55 mm, and there was a tendency that the length of involved lesion in fibrostenotic type was shorter than that of actively caseating type. Bronchial stricture on CT was noticed in 25 (96%) cases and the range of severity was from total occlusion to near-normal and also showed wide variation even though the subtype of ET was same. The increase of peribronchial thickness which was measured by CT, was noticed in 21 cases (91%) among 23 cases (in which the measurement was possible), and there was no improvement of peribronchial thickness in those cases which showed little improvement in bronchial stricture despite anti-tuberculosis treatment. There was no difference in the luminal irregularity of involved bronchi on CT in relation to bronchoscopic subtypes. The mediastinal lymph node enlargement, defined as the diameter of lymph node was larger than 1cm on CT, was detected in 20 cases (77%), and right side was more frequently involved (L : R = 1 : 5.2). The CT finding usually showed extrinsic bronchial compression but showed direct invasion in two cases which were bronchoscopically classified as tumorous type. When follow-up bronchoscopy and CT was performed after one month of anti-tuberculosis treatment in nine patients, CT showed significant improvement in peribronchial thickness and mediastinal lymph node enlargement. Bronchial stricture was also improved in 6 cases but aggravated in 3 cases despite anti-tuberculosis therapy. In two cases which were classified as fibrostenotic type by bronchoscopy, CT showed significant improvement in bronchial stricture, interestingly. Conclusion : We concluded that the role of Chest CT was complimentary to bronchoscopy in ET, since CT was useful in evaluating the length of bronchial involvement, peribronchial thickness, and mediastinal lymph node enlargement.

  • PDF

Characteristics of Bio-impedance for Implantable Electrode Design in Human Skin (인간 피부에 삽입형 전극설계를 위한 생체임피던스 특성)

  • Kim, Min Soo;Cho, Young-Chang
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.19 no.4
    • /
    • pp.9-16
    • /
    • 2014
  • Electrode contact resistance is a crucial factor in physiological measurements and can be an accuracy limiting factor to perform electrical impedance measurements. The electrical bio-impedance values can be calculated by the conductivity and permittivity of underlying tissue using implant electrode in human skin. In this study we focus on detecting physiological changes in the human skin layers such as the sebum layer, stratum corneum layer, epidermis layer, dermis layer, subcutaneous fat and muscle. The aim of this paper is to obtain optimal design for implantable electrode at subcutaneous fat layer through the simulation by finite element methods(FEM). This is achieved by evaluating FEM simulations geometrically for different electrodes in length(50 mm, 70 mm), in shape(rectangle, round square, sexangle column), in material(gold) and in depth(22.325 mm) based on the information coming from the subcutaneous fat layer. In bio-impedance measurement experiments, according to electrode shapes and applied voltage, we have ascertained that there was the highest difference of bio-impedance in subcutaneous fat layer. The methodology of simulation can be extended to account for different electrode designs as well as more physical phenomena that are relevant to electrical impedance measurements of skin and their interpretation.

Implementation of a Predictor for Cell Phase Monitoring at the OLT in the ATM-PON (ATM-PON의 OLT에서 상향 셀 위상감시를 위한 예측기의 구현)

  • Mun, Sang-Cheol;Chung, Hae;Kim, Woon-Ha
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.2C
    • /
    • pp.160-169
    • /
    • 2002
  • An ATM-PON (Passive Optical Network) system consists of an OLT (Optical Line Termination), multiple ONUs (Optical Network Units) and the optical fiber which has a PON (Passive Optical Network)configuration with a passive optical splitter. To avoid cell collisions on the upstream transmission, an elaborate procedure called as ranging is needed when a new ONU is installed. The ONU can send upstream cells according to the grant provided by the OLT after the procedure. To prevent collisions being generated by the variation of several factors, OLT must performs continuously the cell phase monitoring. It means that the OLT predicts the expected arrival time, monitors the actual arrival time for all upstream cells and calculates the error between the times. Accordingly, TC (Transmission Convergence) chip in the OLT needs a predictor which predicts the time that the cell will arrive for the current grant. In this paper, we implement the predictor by using shift registers of which the length is equivalent to the equalized round trip delay. As each register consists of 8 bit, OLT can identify which ONU sends what type of cell (ranging cell, user cell, idle cell, and mini-slot). Also, TC chip is designed to calculate the effective bandwidth for all ONUs by using the function of predictor. With the time simulation and the measurement of an implemented optical board, we verify the operation of the predictor.

A Report of Basic Ecology and Distribution, Host Plants of Cantao ocellatus (Hemiptera: Scutelleridae) in Korea (방패광대노린재 국내 분포, 기주식물 및 기초 생태 보고)

  • Kim, Dong Eon;Kil, Jihyon;Lee, Do Hun
    • Korean journal of applied entomology
    • /
    • v.52 no.2
    • /
    • pp.93-100
    • /
    • 2013
  • In this study, the distribution of Cantao ocellatus in Korea occurred at Jindo, Tongyoung, Gwangju and Taean including Jejudo in 2012 and was coincidentally in accordance with the distribution of Mallotus japonicus as a host plant. The adult emerges in M. japonicus occur from late June to early July and can be observed until the end of October. The investigation of the female and male was measured, developmental characteristics, host plant and oviposition preference under the conditions of temperature $25^{\circ}C({\pm}2)$, humidity 65%(${\pm}2$), day length 16L:8D, by indoor breeding. For females and males respectively, average body lengths were 26.20 mm and 23.88 mm, body widths 11.35 mm and 10.57 mm, head widths 3.84 mm and 3.64 mm, probosics lengths 7.90 mm and 7.27 mm, antennal lengths 9.87 mm and 9.69 mm, anterior leg lengths 12.50 mm and 12.27 mm, intermediate leg lengths 14.61 mm and 13.12 mm, posterior leg lengths 16.90 mm and 16.53 mm, and fresh weights 0.46 g and 0.31 g. It was seen that two kinds of C. ocellatus had prickles at the end of the pronotum which had developed in the fifth instars. The female is distinguished from the male by the reproductive organ and the spotted pattern on the abdominal segment. The preference of drinks was fruit, leafstalk, midrib, and branch in Mallotus japonicus (Thunb.) Muell. Arg., Mallotus japonicus 'Variegatus', Ricinus communis L., Lonicera japonicus var. repens (Siebold) Rehder, Citrus sinensis (L.) Osbeck and Zelkova serrata (Thunb.) Makino.

Ultrasonographic and radiographic evaluation for the quantitative diagnosis of diffuse hepatic disease in dogs (개에서 미만성 간장병변의 정량적 진단을 위한 초음파 및 방사선학적 평가)

  • Sung, Jai-ki;Lee, Hee-chon;Yoon, Jung-hee;Lee, Young-won;An, Yong-joo;Choi, Ho-jung;Choi, Ji-hye
    • Korean Journal of Veterinary Research
    • /
    • v.38 no.4
    • /
    • pp.918-928
    • /
    • 1998
  • The present study was done with two aims. First, to evaluate the radiographic measurements of liver volumes in normal and hepatomegaly dogs induced by carbon tetrachloride. Second, to investigate quantitative tissue echo pattern by ultrasonography. Gray level histogram of the normal liver and the kidney were estimated with carbon tetra-chloride intoxication. In normal, r-square for liver volume to body weight was 0.93372, and this showed direct linear regression. Gray level histograms of the normal liver and the kidney were $19.150{\pm}2.490$(mean${\pm}$SD) and $13.175{\pm}2.686$(mean${\pm}$SD) respectively(p < 0.01). Liver parenchymal echogenicity was more hyperechogenic than kidney cortex echogenicity. Liver/Kidney ratio was $1.504{\pm}0.313$ and it can be used relative comparison of liver and kidney parenchymal echogenicity. In carbon-tetrachloride($CCl_4$) intoxication, changes of liver volume appeared to increase up to 24 hours after administration (p < 0.05), and decreased gradually to normal level after 2~5 days. Gray level histogram of liver parenchyma decreased up to 24hours (p < 0.01) after intoxication and then gradually increased to normal level. But that of kidney cortex had no significant change. Liver/Kidney ratio also decreased by 2 days(p < 0.01) and then gradually increased to normal level. On histopathologic features of hepatic tissues in carbon tetrachloride intoxication, both coagulative necrosis of hepatic cell and hemorrhage of centrilobular & midzonal area were identified. Conclusively, plain radiography is a useful diagnostic method for evaluating liver volume in mild hepatomegaly. Especially, it is considered that an adequate numerical processing of the liver length, depth and thoracic width and depth measurement would be helpful. Using gray level histogram, ultrasonographic evaluation was useful objective methods in early diagnosis of diffuse hepatic disease.

  • PDF