• Title/Summary/Keyword: leg-time

Search Result 592, Processing Time 0.03 seconds

Effects of Landing Foot Orientations on Biomechanics of Knee Joint in Single-legged Landing

  • Joo, Ji-Yong;Kim, Young-Kwan
    • Korean Journal of Applied Biomechanics
    • /
    • v.28 no.2
    • /
    • pp.143-149
    • /
    • 2018
  • Objective: This study aimed to investigate the influence of landing foot orientations on biomechanics of knee joint in order to identify vulnerable positions to non-contact knee injuries during single-legged landing. Method: Seventeen men (age: $20.5{\pm}1.1 years$, height: $175.2{\pm}6.4cm$, weight: $68.8{\pm}5.8kg$) performed single-leg drop landings repeatedly with three different landing foot orientations. They were defined as toe-in (TI) $30^{\circ}$ adduction, neutral (N, neutral), and toe-out (TO) $30^{\circ}$ abduction positions. Results: The downward phase time of TI was significantly shorter than those of N and TO. The flexion and valgus angle of N was greater than those of TI and TO at the moment of foot contact. At the instance of maximum knee flexion, N showed the largest flexion angle, and TO position had the largest varus and external rotation angles. Regarding ground reaction force (GRF) at the moment of foot contact, TO showed the forward GRF, while others showed the backward GRF. TI indicated significantly larger mediolateral GRF than others. As for the maximum knee joint force and joint moment, the main effect of different foot positions was not significant. Conclusion: TI and TO might be vulnerable positions to knee injuries because both conditions might induce combined loadings to knee joint. TI had the highest mediolateral GRF with a shortest foot contact time, and TO had induced a large external rotation angle during downward phase and the peak forward GRF at the moment of foot contact. Conclusively, N is the preferred landing foot orientation to prevent non-contact knee injuries.

Work-Related Risk Factors of Knee Meniscal Tears in Korean Farmers: A Cross-Sectional Study

  • Hong, Chae Young;Lee, Chul Gab;Kim, Dong Hwi;Cho, Yong Soo;Kim, Kweon Young;Ryu, So Yeon;Song, Han Soo
    • Safety and Health at Work
    • /
    • v.11 no.4
    • /
    • pp.485-490
    • /
    • 2020
  • Background: Meniscal tears are among the major risk factors for knee osteoarthritis progression. This study aimed to investigate the relationship between meniscal tears and work-related factors in the farming occupation. Methods: The participants included 486 farmers (238 men and 248 women), aged 40-69 years, who were among the 550 farmers registered in the Korea Farmer's Knee Cohort (KFKC). Data such as those on gender, age, body mass index (BMI), mechanical axis, cumulative heavy-lifting working time (CLWT), cumulative squatting working time (CSWT), and previous knee injury history were collected from the questionnaire, along with whole leg radiographic findings. Two radiologists assessed the magnetic resonance images of both knees to confirm the presence of meniscal tears. The factors related to meniscal tears were analyzed by multiple logistic regression. Results: A total of 54.5% of the farmers (48.7% of men and 60.1% of women) had meniscal tears. These tears were associated with gender, age, and BMI. We also identified an association between meniscal tears and CSWT, an especially important factor in farming [10,000-19,999 working hours, odds ratio = 2.16, 95% confidence interval (CI): 1.14-4.07, ≥20,000 working hours, odds ratio = 2.35, 1.45-3.80]. However, mechanical axis, knee injury history, and CLWT were not significantly related to meniscal tears. Conclusion: This study's findings show that squatting for long periods, as an occupational factor, is related to meniscal tears.

Pregnancy diagnosis in goat by using vaginal cytology and trans-abdominal ultrasonography

  • Ali, Md. Aziz;Islam, Md. Faruk;Rahman, SM Latifur;Zohara, Begum Fatema
    • Journal of Animal Reproduction and Biotechnology
    • /
    • v.35 no.4
    • /
    • pp.338-346
    • /
    • 2020
  • The present study was conducted in a goat farm for pregnancy diagnosis by using vaginal cytology and B-mode real time ultrasound using 5 MHz probe by transabdominal method. Seventeen pregnant does were used for this study. The objective of the study was to determine the earliest day of pregnancy and describe the chronological characteristics of pregnancy from day 22 to day 40 for vaginal cytology and day 25 to day 60 for ultrasonography of gestation. The differences among the average percentage of cell value in different age of pregnancy were significant (p < 0.05). The average percentage of intermediate cells (81.12%) was also significantly (p < 0.05) higher than superficial (9.41%), keratinized (7.10%) and neutrophil (2.61%) on 22-40th days of pregnancy. In case of real time B-mode ultrasonography, the gestational sac was observed only in three does out of seventeen (17.6 %) at 25-30 days whereas the placentomes and heart beat of the foetus were first detected at 31-35 days in six does (35.3%). The foetal leg buds were first visualized at 36-40 days in four does (23.5%) whereas the foetal vertebral column was first observed at 36-40 days of gestation in only three does (17.6%). In conclusion, vaginal cytology and trans-abdominal ultrasonography can be used for detection of early pregnancy in does.

Effects of the Patellar Tendon Strap on Kinematics, Kinetic Data and Muscle Activity During Gait in Patients With Chronic Knee Osteoarthritis

  • Eun-Ji Lee;Ki-Song Kim;Young-In Hwang
    • Physical Therapy Korea
    • /
    • v.30 no.2
    • /
    • pp.110-119
    • /
    • 2023
  • Background: Osteoarthritis is a common condition with an increasing prevalence and is a common cause of disability. Osteoarthritic pain decreases the quality of life, and simple gait training is used to alleviate it. Knee osteoarthritis limits joint motion in the sagittal and lateral directions. Although many recent studies have activated orthotic research to increase knee joint stabilization, no study has used patellar tendon straps to treat knee osteoarthritis. Objects: This study aimed to determine the effects of patellar tendon straps on kinematic, mechanical, and electromyographic activation in patients with knee osteoarthritis. Methods: Patients with knee osteoarthritis were selected. After creating the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), leg length difference, Q-angle, and thumb side flexion angle of the foot were measured. Kinematic, kinetic, and muscle activation data during walking before and after wearing the orthosis were viewed. Results: After wearing the patellar tendon straps, hip adduction from the terminal stance phase, knee flexion from the terminal swing phase, and ankle plantar flexion angle increased during the pre-swing and initial swing phases. The cadence of spatiotemporal parameters and velocity increased, and step time, stride time, and foot force duration decreased. Conclusion: Based on the results of this study, the increase in plantar flexion after strap wearing is inferred by an increase due to neurological mechanisms, and adduction at the hip joint is inferred by an increase in adduction due to increased velocity. The increase in cadence and velocity and the decrease in gait speed and foot pressure duration may be due to joint stabilization. It can be inferred that joint stabilization is increased by wearing knee straps. Thus, wearing a patellar tendon strap during gait in patients with knee osteoarthritis influences kinematic changes in the sagittal plane of the joint.

The Development of Functional Seasoning Chicken Products using Natural Extracts of Green Tea and Water Soluble Mineral Ion (녹차와 기능수를 이용한 기능성 양념 계육 개발)

  • 성삼경;조영석;김은주;김수민
    • The Korean Journal of Food And Nutrition
    • /
    • v.16 no.3
    • /
    • pp.171-179
    • /
    • 2003
  • In order to investigate the effects of pickle carrier on physico-chemical characteristics of seasoning chicken products, chicken were cured in seasoning containing 100 ppm germanium water, green tea, water soluble mineral and mixtures(100 ppm germanium water+green tea+water soluble mineral) after addition of 0.1% concentration to the weight of chicken. The determination of pH, salt and sugar contents were carried out, according to curing time. The salt content showed 1.11 %, 1.21 % in cured at 24 hours in control of breast and leg, irrespective of chicken parts, in which showed 19.94 brix, 18.89 brix in sugar content, respectively. These results mean that breast and leg meat added with natural extracts and functional water showed higher sugar content than that of control, in which revealed shortening of curing time by increasing penetrating velocity of salt and sugar content. Thus, salt and sugar content tended to be increased as the curing time of pickle carrier were extended in seasoning chicken after dipping in pickle containing water soluble mineral ions for 6 hours. The seasoning chicken treated with natural extracts and functional water showed a lower than that of control in hardness, irrespective of chicken parts. Overall, the seasoning chicken treated with natural extracts and functional water showed a low TBARS value and Log CFU/g, in which revealed antioxidative and antimicrobial activity. The sensory evaluations of seasoning chicken added with natural extracts and functional water containing water-soluble mineral ions were not significantly different(P<0.05). The glutamic acid among free amino acid contents showed a high in seasoning chicken treated with green tea, compared to control. This amino acid played a important role in taste of seasoning meat. The doneness appearance in seasoning chicken added with natural extracts and functional water containing water-soluble mineral ions tended to not be different, compared to those of control. These results revealed that seasoning chicken added with natural extracts and functional water containing water-soluble mineral ions would be attractive in fast food market on the basis of improvement of tenderness, shortening of curing time and uniformity of roasting appearance in seasoning chicken.

Kinematic Effects of Newly Designed Knee-Ankle-Foot Orthosis With Oil Damper Unit on Gait in People With Hemiparesis

  • Park, Hyung-Ki;Kim, Tack-Hoon;Choi, Houng-Sik;Roh, Jung-Suk;Cynn, Heon-Seock;Kim, Jong-Man
    • Physical Therapy Korea
    • /
    • v.20 no.1
    • /
    • pp.64-73
    • /
    • 2013
  • The purposes of this study were to develop a new orthosis controlling ankle and knee joint motion during the gait cycle and to identify the effects of the newly designed orthosis on gait kinematics and tempospatial parameters, including coordination of the extremities in stroke patients. Fifteen individuals who had sustained a stroke, onset was 16 months, participated in this study. Before application of the measurement equipment the subjects were accustomed to walking on the ankle-foot orthosis (AFO) or stance control knee with knee flexion assisted-oil damper ankle-foot orthosis (SCKAFO) for 5 minutes. Fifteen patients were investigated for 45 days with a 3-day interval between sessions. Measurements were walking in fifteen stroke with hemiparesis on the 3D motion analysis system. Comparison of AFO and SCKAFO are gait pattern. The difference between the AFO and SCKAFO conditions was significant in the gait velocity, step length of the right affected side, stance time of both legs, step-length asymmetry ratio, single-support-time asymmetry ratio, ${\phi}$-thigh angle and ${\phi}$-shank angle in the mid swing (p<.001). Using a SCKAFO in stroke patients has shown similar to normal walking speeds can be attained for walking efficiency and is therefore desirable. In this study, the support time of the affected leg with the SCKAFO was longer than with the AFO and the asymmetry ratio of single support time decreased by more than with the AFO. This indicates that the SCKAFO was effective for improving gait symmetry, single-support-time symmetry. This may be due to the decrease of gait asymmetry. Thus, the newly designed SCKAFO may be useful for promoting gait performance by improving the coordination of the extremity and decreasing gait asymmetry in chronic stroke patients.

ZnO nanostructures for e-paper and field emission display applications

  • Sun, X.W.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.993-994
    • /
    • 2008
  • Electrochromic (EC) devices are capable of reversibly changing their optical properties upon charge injection and extraction induced by the external voltage. The characteristics of the EC device, such as low power consumption, high coloration efficiency, and memory effects under open circuit status, make them suitable for use in a variety of applications including smart windows and electronic papers. Coloration due to reduction or oxidation of redox chromophores can be used for EC devices (e-paper), but the switching time is slow (second level). Recently, with increasing demand for the low cost, lightweight flat panel display with paper-like readability (electronic paper), an EC display technology based on dye-modified $TiO_2$ nanoparticle electrode was developed. A well known organic dye molecule, viologen, was adsorbed on the surface of a mesoporous $TiO_2$ nanoparticle film to form the EC electrode. On the other hand, ZnO is a wide bandgap II-VI semiconductor which has been applied in many fields such as UV lasers, field effect transistors and transparent conductors. The bandgap of the bulk ZnO is about 3.37 eV, which is close to that of the $TiO_2$ (3.4 eV). As a traditional transparent conductor, ZnO has excellent electron transport properties, even in ZnO nanoparticle films. In the past few years, one-dimension (1D) nanostructures of ZnO have attracted extensive research interest. In particular, 1D ZnO nanowires renders much better electron transportation capability by providing a direct conduction path for electron transport and greatly reducing the number of grain boundaries. These unique advantages make ZnO nanowires a promising matrix electrode for EC dye molecule loading. ZnO nanowires grow vertically from the substrate and form a dense array (Fig. 1). The ZnO nanowires show regular hexagonal cross section and the average diameter of the ZnO nanowires is about 100 nm. The cross-section image of the ZnO nanowires array (Fig. 1) indicates that the length of the ZnO nanowires is about $6\;{\mu}m$. From one on/off cycle of the ZnO EC cell (Fig. 2). We can see that, the switching time of a ZnO nanowire electrode EC cell with an active area of $1\;{\times}\;1\;cm^2$ is 170 ms and 142 ms for coloration and bleaching, respectively. The coloration and bleaching time is faster compared to the $TiO_2$ mesoporous EC devices with both coloration and bleaching time of about 250 ms for a device with an active area of $2.5\;cm^2$. With further optimization, it is possible that the response time can reach ten(s) of millisecond, i.e. capable of displaying video. Fig. 3 shows a prototype with two different transmittance states. It can be seen that good contrast was obtained. The retention was at least a few hours for these prototypes. Being an oxide, ZnO is oxidation resistant, i.e. it is more durable for field emission cathode. ZnO nanotetropods were also applied to realize the first prototype triode field emission device, making use of scattered surface-conduction electrons for field emission (Fig. 4). The device has a high efficiency (field emitted electron to total electron ratio) of about 60%. With this high efficiency, we were able to fabricate some prototype displays (Fig. 5 showing some alphanumerical symbols). ZnO tetrapods have four legs, which guarantees that there is one leg always pointing upward, even using screen printing method to fabricate the cathode.

  • PDF

The Effect of Vibration Training Pre-eccentric Exercise on Delayed Onset Muscle Soreness of Triceps Surae (원심성 운동 전 진동 훈련이 하퇴근육의 지연성 근통증에 미치는 영향)

  • Kim, Eun-Suk;Kim, Mi-Hwa;Cho, Yu-Mi;Lee, Wan-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.12
    • /
    • pp.5789-5796
    • /
    • 2011
  • This study examined the effect of VT(Vibration Training) on the symptoms of DOMS (Delayed-Onset Muscle Soreness) before induced by eccentric exercise of the left leg triceps surae. Twenty one healthy adult men and women who had not participated in a regular exercise program for the lower extremities were assigned to one of two experimental groups: vibration training group, Control group. We measured the VAS(Visual Analogue Scale), ankle plantar flexor strength, triceps surae circumference, CK(Creatine Kinase) before and after exercise and 24, 48 and 72 hours after eccentric exercise. After inducing DOMS, VAS showed significant differences between groups at a point of time 48 hours, and showed significant differences within groups in accordance with the time of measurement(p<.05). Plantar flexor strength of groups with VT did not show significant difference between groups but, showed significant differences within groups in accordance with the time of measurement(p<.05). Triceps surae circumference of groups with VT did not show significant difference between groups but, showed significant differences within groups in accordance with the time of measurement(p<.05). CK of groups with VT did not show significant difference between groups but, showed significant differences within groups in accordance with the time of measurement(p<.05). As a result of the study, VT prior to eccentric exercise is effective to inhibit pain. So, this method can be suggested to prevent DOMS in doing an unfamiliar activites.

Reconstruction of Anterior Cruciate Ligament in Adolescent (청소년기에 시행한 전방십자인대 재건술)

  • Song Eun Kyoo;Shim Sang Don;Kim Hyung Jong;Kim Hyung Won
    • Journal of the Korean Arthroscopy Society
    • /
    • v.6 no.2
    • /
    • pp.101-108
    • /
    • 2002
  • Purpose: To evaluate the clinical results of anterior cruciate ligament (ACL) reconstruction and to know the results of physeal injury by transphyseal tunnel in adolescents who had remaining growth potential. Materials and Methods : This study involved 12 patients under 19 years old out of 445 patients, who underwent ACL reconstruction between 1993 and 2001. The mean age at the time of operation was 15.9 $(13.1\~16.9)$ years and fellow-up period was 45.1 $(24\~120.6)$ months in avrarge. Autologous quadrupled hamstring tendon was used as graft in 11 cases and bone-patellar tendon-bone in 1 case. Clinical results were evaluated by Lysholm Knee Scoring Scale, range of motion and return to preinjury sports activities. Radiologic results were evaluated by $Telos^{\circledR}$ device. Bone maturity were analyzed by chronological age, standing height and the width of growth plate in AP and lateral view of knee joint at preoperatively. The growth disturbances were evaluated by measuring femorotibial angle, anatomical and mechanical lateral distal femoral angle, mechanical medial proximal tibial angle and leg length and by comparing those of uninjured site in last follow-up teleoroentgenogram. Results : The mean Lysholm Knee score was 51 $(25\~63)$points preoperatively and 98 $(94\~100)$ points at last follow up. The mean anterior displacement of the tibia by using $Telos^{\circledR}$ device was improved from 13.5 $(6\~27)$ mm to 2.9 $(1\~4)$ mm and there were no significant instabilities of the knee in all cases. There were no leg length discrepancies over 1 cm and no statistically significant abnormal alignment of the knee joint in all cases. Conclusion: ACL reconstruction using transphyseal tunnel for restoring stability and knee function is assumed as a good mettled of treatment without significant leg length discrepancy and abnormal alignment of the knee joint.

  • PDF

Regional Differences of Entry Rate of Freely Diffusible Substances from Peritoneal Cavity (복강내 확산성 물질의 부위별 흡수속도)

  • Cho, Byeong-Deuck;Shin, Dong-Hoon
    • The Korean Journal of Physiology
    • /
    • v.1 no.2
    • /
    • pp.157-168
    • /
    • 1967
  • The entry of antipyrine and urea from the peritoneal cavity of rabbit into organ tissue and blood plasma was studied. Two hundred mg of antipyrine plus 300 mg of urea in 10 ml Ringer's solution was injected into the peritoneal cavity of anesthetized rabbit. The injection was made from above of a rabbit kept tying right side down and it enabled part of the abdominal organs (liver, intestine, kidney) was immersed in the injected solution and kept high concentration gradient throughout the experimental period. The remaining part of the organs was revered only by a thin film of the test solution. Subsequently, in this part of the organs the concentration gradient of the diffusible substances during entry was presumed to decrease as time elapsed. Four pieces of the liver tissue were taken namely, the right superficial, right deep, left superficial and left deep portions. Two were taken from the small intestine, one from the portion which was immersed in. the fluid and the other from that above the fluid mass. Both kidneys were separately analyzed. As a remote organ the gastrocnemius muscle was taken from the right leg of the animal. The intervals which were the time periods elapsed after injections were 5,7,10,15 or 30 minutes. At each point 5 animals were sacrificed and the concentrations of the test substances in the tissue water were measured. The results obtained were as follows. 1. In the liver the right portion which was immersed in the fluid showed higher concentration if the test substances than the left portion and the superficial region exceeded the deep region. The concentrations diminished as the time elapsed after infusion, particulary in the case of antipyrine, suggesting circulatory removal of the substances. In urea such decreasing tendency of the concentration was not obvious, and suggested slower removal rate of it as compared with that of antipyrine. 2. In the small intestine there was no regional difference in the concentration of the test substances. Because of the intestinal motility different portions of the intestine were seemed to have bathed in the fluid of the same concentration. In general the concentrations in the intestinal wall exceeded those of the liver, suggesting a slower removal rate than in the latter. 3. In the kidney the accumulation of the endogenous urea was predominant, and the accumulating mechanism in the renal tissue went on during the period of the experiment. Therefore it revealed increasing tendencies as the time elapsed. The penetration of the test substances in this organ from the peritoneal cavity seemed to be slower than in other abdominal organs, namely liver or small intestine. Part of the test substances in the kidney were obviously brought by the blood stream. 4. Rapid exponential decay of the concentration of antipyrine and of the osmolality of the peritoneal fluid was attributed to the extensive removal through the whole dimension of the peritoneal surface, and the remote organ such as the gastrocnemius muscle attained a fairly close value to that of the abdominal organs in less than 30 minutes. The factors which related to the absorption rate were discussed. They were the concentration gradient, permeability and the regional perfusion rate.

  • PDF