• Title/Summary/Keyword: leg diameter

Search Result 53, Processing Time 0.028 seconds

Effect of Compression Test Conditions on the Textural Parameters of Imitation Crab-leg Product (압착시험 조건이 게맛살의 조직감 지표에 미치는 영향)

  • Choi, Won-Seok;Lee, Cherl-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.30 no.5
    • /
    • pp.1077-1084
    • /
    • 1998
  • The optimum conditions fer the measurement of texture profile of imitation crab-leg products were investigated by different conditions using Texture Analyser and the date were compared to those of sensory evaluations. The textural characteristics of surimi gels were compared with those of imitation crab-leg products. The TPA values of 5 different kinds of commercial imitation crab-leg product and 2 kinds of surimi gel products purchased in a market in Seoul were measured. In surimi gels, instrumental hardness and cohesiveness were higher than those of imitation crab-leg products, especially chewiness and gumminess were significantly higher than those of imitation crab-leg products. In imitation crab-leg products, hardness and cohesiveness increased and springiness decreased as the probe diameter increased from 12.5 mm to 24.6 mm. In the different compression ratio (60, 70, 80%), hardness increased and cohesiveness and springiness decreased as the compression ratio increased. The chewiness, gumminess, cohesiveness and hardness increased slightly as the cross-head speed increased from 0.8 to 2.4 mm/sec. Significant correlations between mechanical and sensory values were observed in gumminess, chewiness, cohesiveness and hardness. The optimum conditions for the TPA measurement of imitation crab-leg products were a cross-head speed of 2.4 mm/sec and 60% compression ratio with a flat probe having twice of the sample diameter (24.6 mm).

  • PDF

Best Estimate Small Break LOCA Analysis for KNGR SIS Optimization

  • Song, Jin-Ho;Lim, Hong-Sik;Bae, Kyoo-Hwan;Lee, Joon
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.417-422
    • /
    • 1996
  • The KNGR has an advanced ECCS design feature which employs four mechanically-separated SI trains where each train consisting of one HPSI pump and one SIT injects ECC water directly into the reactor vessel downcomer annulus. To demonstrate that the KNGR ECCS design features meet the EPRI ALWR requirements of no core uncovery for a break of up to 6 inch diameter, small break LOCA cases with various break sizes were analyzed using a best-estimate analytical procedure. Two kinds of break locations are considered: cold leg and DVI line breaks. It was observed that the KNGR ECC design can tolerate a cold leg break of up to 10 inches with no core uncovery. However. since DVI line break with 6 inch diameter undergoes slight core uncovery. further investigation is required for KNGR SIS optimization.

  • PDF

Fatigue Properties of the Small Diameter Branch Welded Pipe Joint with variation of Welding Procedures and Welding Shapes. (용접공정 및 용접형상 변화에 따른 소구경 분기배관 용접부의 피로특성)

  • 백종현;김철만;김우식
    • Proceedings of the KWS Conference
    • /
    • 2003.11a
    • /
    • pp.191-193
    • /
    • 2003
  • S-N fatigue tests were conducted to investigate the fatigue strength of the small diameter socket and butt welded joints of carbon steels. Experimental parameters were pipe diameter, throat depth, shape of socket welds and welding procedure. Filler metals used in SMAW and GTAW procedure were E9016-G with diameter of 4.0 mm and ER70S-G with diameter of 2.4 m. API 5L Gr.B pipes were adopted as a small diameter branch pipes. All socket fittings were machined from ASTM A105 carbon steel. Fatigue strength in socket weld joints increased with increasing pipe diameter, area of weld metal and weld leg length of pipe side.

  • PDF

Influence of Welding Shapes and Welding Procedures on Fatigue Strength of Small Diameter Branch Welded Pipe Joint (소구경 분기배관 용접부의 피로강도에 미치는 용접부 형상 및 용접공정의 영향)

  • Baek, Jong-Hyun;Kim, Cheol-Man;Kim, Woo-Sik
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1092-1097
    • /
    • 2003
  • S-N fatigue tests were conducted to investigate the fatigue strength of small diameter socket and butt welded joints made of carbon steels. Experimental parameters were pipe diameter, throat depth, shape of socket welds and welding procedure. Filler metals used in SMAW and GTAW procedure were E9016-G with diameter of 4.0 mm and ER70S-G with diameter of 2.4 mm. API 5L Gr.B pipes were adopted as a small diameter branch pipes. All socket fittings were machined from ASTM A105 carbon steel. Tensile strength was not affected by the welding procedure. Fatigue strength in socket weld joints increased with increasing pipe diameter, area of weld metal and weld leg length of pipe side.

  • PDF

S-N Fatigue Strength of Small Diameter Branch Welded Pipe with Variation of Welding Shapes and Welding Procedures (용접부의 형상과 공정변화에 따른 소구경 분기배관의 피로강도 특성평가)

  • 백종현;김우식
    • Journal of Welding and Joining
    • /
    • v.22 no.3
    • /
    • pp.50-55
    • /
    • 2004
  • S-N fatigue tests were conducted to investigate the fatigue strength of small diameter socket and butt welded joints made of carbon steels. Experimental parameters were pipe diameter, throat depth, shape of socket welds and welding procedure. Filler metals used in SMAW and GTAW procedure were E9016-G with diameter of 4.0 m and ER70S-G with diameter of 2.4 m. API 5L Gr.B pipes were adopted as a small diameter branch pipes. All socket fittings were machined from ASTM A105 carbon steel. Tensile strength was not affected by the welding procedure. Fatigue strength in socket weld joints increased with increasing pipe diameter, area of weld metal and weld leg length of pipe side.

Development of a pipeline robot like foxtail (강아지풀 형상을 닮은 관내 주행로봇 개발)

  • Choi, Yong-Ho;Yang, Hyun-Suk;Park, No-Chul
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1167-1172
    • /
    • 2007
  • Generally inpipe robot needs force above standing for contacting robot to pipe. If the environment of the pipe-inside does not change, there is not a problem. But if the pipe radius change, or occur the obstacle which it does not intend, problem gets. So it uses a different system and must know an environment change, and changing the shape or a form of the robot. The research uses the flexible leg and is the robot which is adapted to the environment change of the pipe. The advantage of this robot is possible to move when it does not need to recognize a change of environment of pipe. Leg is bend with one direction. When it moves part that there are legs effect of leg direction the robot is moved with only one direction. If friction between legs and pipe is sufficient, not only verticality pipe moving, but also curved pipe moving. Also the obstacle of the pipe inside occurs and the diameter of the pipe inside changes, this robot can move if it does not use another system or device.

  • PDF

Air-Water Countercurrent Flow Limitation in a Horizontal Pipe Connected to an Inclined Riser

  • Kang, Seong-Kwon;Chu, In-Cheol;No, Hee-Cheon;Chun, Moon-Hyun;Sung, Chang-Kyung
    • Nuclear Engineering and Technology
    • /
    • v.31 no.6
    • /
    • pp.548-560
    • /
    • 1999
  • An experimental investigation has been peformed to examine the effects of various geometrical parameters and an initial operating condition on the air-water countercurrent How limitation (CCFL) in a simulated PWR hot leg. A total of 118 experimental data for the onset of CCFL and zero liquid penetration were obtained for various combinations of test parameters. It was observe that the CCFL can be classified into three different categories: (the onset of CCFL, (the partial liquid delivery, and (r) the zero liquid penetration. The observed mechanisms of the onset of CCFL were different depending on the inlet water flow rate. The parametric effects of pipe diameter, horizontal pipe length, horizontal pipe length-to-diameter (L/D) ratio, and initial water level in the horizontal pipe of the test section on the onset of air-water CCFL were also examined. An empirical correlation for the onset of CCFL in a horizontal pipe connected to an inclined riser was developed in terms of Wallis flooding parameters for the low inlet water flow rate region. Comparisons of the present empirical correlation with the air-water CCFL data of large pipe diameters show that the present correlation agrees more closely with the experimental data than the existing CCFL correlations.

  • PDF

Comparison of Thermal Energy Harvesting Characteristics of Thermoelectric Thin-Film Modules with Different Thin-Film Leg Diameters (박막레그 직경에 따른 열전박막모듈의 열에너지 하비스팅 특성 비교)

  • Kim, Woo-Jun;Oh, Tae Sung
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.25 no.4
    • /
    • pp.67-74
    • /
    • 2018
  • Thermoelectric thin film modules were fabricated by electroplating p-type $Sb_2Te_3$and n-type $Bi_2Te_3$ thin film legs with the same thickness of $20{\mu}m$ and different diameters of $100{\mu}m$, $300{\mu}m$, and $500{\mu}m$, respectively. The output voltage and output power of thin film modules were measured and compared as a function of the leg diameter. The modules processed with thin film legs of $100{\mu}m$, $300{\mu}m$, and $500{\mu}m$-diameter exhibited open circuit voltages of 365 mV at ${\Delta}T=36.7K$, 142 mV at ${\Delta}T=37.5K$, and 53 mV at ${\Delta}T=36.1K$, respectively. Maximum output powers of $845{\mu}W$ at ${\Delta}T=36.7K$, $631{\mu}W$ at ${\Delta}T=37.5K$, and $276{\mu}W$ at ${\Delta}T=36.1K$ were obtained for the modules fabricated with the thin film legs of $100{\mu}m$, $300{\mu}m$, and $500{\mu}m$-diameter, respectively.

INFLUENCE OF IMPLANT DIAMETER ON THE OSSEOINTEGRATION OF IMPLANTS : AN EXPERIMENTAL STUDY IN RABBITS (임플란트 직경이 골유착에 미치는 영향에 관한 연구)

  • Lee Jun-Ho;Shin Sang-Wan;Kwon Sang-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.2
    • /
    • pp.169-181
    • /
    • 2003
  • Statement of problem : The survival rate of wide diameter implants was lower than of 3.75-mm implants in some clinical researches. Purpose : The purpose of this study was to investigate the influence of implant diameter on the osseointegration of implants in the rabbit femoral condyle and tibial metaphyses by means of removal torque measurements and histomorphometric analysis. Material and Method : Ten adult New Zealand White rabbits were used in this study Two 3.75-mm diameter implants were inserted through one cortical layer in the tibial metaphyses and one 3.75-mm diameter implant was inserted in the femoral condyle. 5.0-mm diameter implants were inserted in the other leg in the same manner. A total of 60 implants (3.75-mm diameter implants:30 : 5.0-mm diameter implants:30) were installed. After a healing time of 4 and 12 weeks, the peak removal torque values required to shear off the implants were recorded. From the removal torque values (Ncm) obtained, the mean shear stress ($N/mm^2$) was calculated. And the percentage of direct bone-to-implant contact and the percentage of bone area inside the thread were measured by Kappa Image Base-metreo. The Student's t-test was undertaken for statistical analysis (p<0.05). Results : The removal torque value of 5.0-mm diameter implants was higher than of 3.75-mm diameter implants (p<0.05). The difference of shear stress value between 3.75-mm and 5.0-mm diameter implants was not statistically significant (p>0.05). The percentage direct bone-to-implant contact had no statistical difference between two groups (p>0.05). The percentage of bone area inside the thread had no statistical difference between two groups (p>0.05). Conclusion It is concluded that the quality f osseointegration is not influenced by increasing implant diameter.

The Study on Model Test of Tension Leg Platform(II) - Model Test & Analysis (심해 계류인장각 플랫폼의 모형시험 연구(II) - 모형시험 및 해석)

  • Kim, Jin-Ha;Hong, Sa-Young;Choi, Yoon-Rak;Hong, Sup;Kim, Hyun-Joe
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2000.04a
    • /
    • pp.69-74
    • /
    • 2000
  • Linear and nonlinear motion responses of a Tension Leg Platform(TLP) was investigated by model tests. The model tests were carried out at KRISO's Ocean Engineering Basin which has a deep pit of which diameter and depth are 5 meters and 12.5 meters, respectively. Optical sensors were used for measuring drift motions, and a set of accelerometers were employed for analyzing wave frequency motions. ISSC TLP was chosen as the model for the present study. Scale ratio was 1/65 and elastic modelling of tether system were conducted. Very good agreement was obtained between experimental results and theoretical calculations not only in linear motion responses but tension responses, nonlinear wave drift force and double frequency excitations.

  • PDF