• Title/Summary/Keyword: least depth

Search Result 458, Processing Time 0.025 seconds

Application of Dielectric Sensor for Soil Moisture Measurement (토양 수분 측정을 위한 유전율식 쎈서 연구)

  • Oh, Yong-Taeg;Oh, Dong-Shig;Song, Kwan-Cheol;Shin, Jae-Sung;Im, Jung-Nam
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.31 no.2
    • /
    • pp.85-94
    • /
    • 1998
  • Due to relatively high permittivity of water in soils, we placed the soil condenser into soils to measure the soil moisture content. The soil condenser was made with two insulated iron sticks. The capacitance of the soil condenser was determined by the pulse period from RC type oscillation circuit and the highest voltage output accepting 10MHz pulse. After zero point adjustment, the measured relative capacitance percentage (RCS) to the standard condenser obtained by the oscillation circuit almost linearly correlated with the end depth of the sensor submerged in water. The RC type oscillation was disturbed by many sensor installed in a close distance in one place, presumably resulting in that the sensor sticks played as a interfering antennas generating or accepting electron waves from them. The temperature dependance of the output from the sensors could be corrected through experimentally determined revision function. Although lineal correlation was found between soil moisture and RCS, users should derive their own correlation function for every sensor to measure soil moisture, because the outputs were influenced by the installation depth and layout in the soil. The voltage type sensor responded inversely with soil moisture content and so was not suitable to the accurate measurement of soil moisture, but allows high economic benefit in various application such as simplified measurement of soil moisture and irrigation line control because of its low component count. The voltage type moisture sensor could be reinforced by relay controlling circuit to open and to close the solenoid valves respectively at optimal limits of the least and the most soil moisture according to user's adjustment.

  • PDF

Significance of HPV Infection and Genic Mutation of APC and K-ras in Patients with Rectal Cancer

  • Sun, Zhen-Qiang;Wang, Hai-Jiang;Zhao, Ze-Liang;Wang, Qi-San;Fan, Chuan-Wen;Kureshi, Kureshi;Fang, Fa
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.1
    • /
    • pp.121-126
    • /
    • 2013
  • Background: Significance of HPV infection and genic mutation of APC and K-ras in rectal cancer has been investigated but not clarified. The objective of our study was to investigate these parameters in patients with rectal cancer to analyze correlations with biological behaviour, to determine relationships among the three, and also to demonstrate survival prognosis effects. Methods: From December 2007 to September 2008, 75 rectal cancer cases confirmed by histopathology in the Tumor Hospital of Xinjiang Medical University were enrolled. The control group consisted of normal rectal mucous membrane taken simultaneously, a least 10 cm distant from the carcinoma fringe. HPV DNA, the MCR of APC and exon-1 of K-ras were detected by PCR and PCR-SSCP. All results were analyzed in relation to clinical pathological material, using chi-square and correlation analysis via SPSS.13 and Fisher's Exact Probability via STATA. 9.0. All 75 patients were followed up for survival analysis using Kaplan-Meier and Log-rank tests. Results: 55 out of 75 cases demonstrated gene HPV L1 while it was notdetected in normal rectal mucosa tissue. HPV infection was correlated with age and lymphatic metastasis (P<0.05) but not other characteristics, such as ethnicity, tumor size, histological type, tumor type, Duke's stage and infiltration depth. Some 43 cases exhibited APC genic mutation (57.3%) and 34 K-ras genic mutation (45.3%). APC genic mutation was correlated with gender(P<0.05), but not age, histological type, infiltration depth, lymphatic metastasis and Duke's stage. In 55 cases of rectal cancer with HPV infection, there were 31 cases with genic mutation of APC (56.4%) and 24 with genic mutation of K-ras (43.6%). For the 20 cases of rectal cancer with non-HPV infection, the figures were 12 cases (60%) and 10 (50.0%), respectively, with no significant relation. Survival analysis showed no statistical significance for K-ras genic mutation, APC genic mutation or HPV infection (P>0.05). However, the survival time of the patients with HPV infection was a little shorter than in cases without HPV infection. Conclusions: Our results suggest that HPV infection might be an important factor to bring about malignant phenotype of rectal cancer and influence prognosis. Genic mutation of APC and K-ras might be common early molecular events of rectal cancer, but without prognostic effects on medium-term or early stage patients with rectal cancer.

Size Effect on Flexural Compressive Strength of Reinforced Concrete Beams (철근콘크리트 보의 휨압축강도에 대한 크기효과)

  • 김민수;김진근;이성태;김장호
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.6
    • /
    • pp.934-941
    • /
    • 2002
  • It is important to consider the effect of member size when estimating the ultimate strength of a concrete flexural member because the strength always decreases with an increase of member size. In this study, the size effect of a reinforced concrete (RC) beam was experimentally investigated. For this purpose, a series of beam specimens subjected to four-point loading were tested. More specifically, three different effective depth (d$\approx$15, 30, and 60 cm) reinforced concrete beams were tested to investigate the size effect. The shear-span to depth ratio (a/d=3) and thickness (20 cm) of the specimens were kept constant where the size effect in out-of-plane direction is not considered. The test results are curve fitted using least square method (LSM) to obtain parameters for the modified size effect law (MSEL). The analysis results show that the flexural compressive strength and the ultimate strain decrease as the specimen size increases. In the future study, since $\beta_1$ value suggested by design code and ultimate strain change with specimen size variation, a more detailed analysis should be performed. Finally, parameters for MSEL are also suggested.

Evolution of the Subcontinental Lithospheric Mantle of Korean Peninsula: Partial Loss and its Timing (한반도 대륙암권맨틀의 진화: 부분적 손실과 그 시기)

  • Park, Kye-Hun
    • The Journal of the Petrological Society of Korea
    • /
    • v.19 no.3
    • /
    • pp.199-208
    • /
    • 2010
  • The Cenozoic alkali basalts are distributed over Korea, both on central part as Bangnyeongdo, Ganseong, Pyeongtaek-Asan and Jogongni and also on southernmost part Jejudo. The ultramafic mantle xenoliths carried by Korean alkali basalts are spinel lherzolites. Garnet lherzolite that is more stable at the deeper level has not been reported so far, indicating that the lithospheric thickness under Korea does not reach deep enough to the stable zone of garnet lherzolite. The crustal evolution history of the Korean peninsula, at least some part of it, seemingly started since the Archean, it normally should have lithospheric thickness greater than 150 km. However, the mantle xenoliths carried by the Cenozoic alkali basalts indicate the maximum depth of origination in the much shallower range of 60-90 km. Such significantly thinner lithospheric thickness of the Korean peninsula than expected is quite similar to the case of North China Craton having lithospheric thickness of ca. 80 km in average, suggesting thinning of the lithospheric mantle in a depth scale of a few tens of kilometers during the past geologic time. The main causal events for such significant thinning of the lithospheric mantle can be continental collisional events of Paleoproterozoic and early Mesozoic similar to the case of North China Craton, which are also supported by Paleoproterozoic igneous and metamorphic events during the 1.9-2.0 Ga occurring all over the Korean peninsula and also early Mesozoic continental collisional event which has been discussed on lively arguments.

Chinese Broadcasters' Perceptions on Localization of Korean Entertainment Formats in China-Focused on In-depth Interviews on and (한국 예능 포맷의 중국 현지화에 대한 중국내 방송종사자의 인식 -<대단한 도전>과 <달려라 형제>에 대한 심층인터뷰를 중심으로)

  • Wang, Ying-Ying;Choi, E-Jung
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.11
    • /
    • pp.57-70
    • /
    • 2019
  • Despite both the Korean version of and seemed to be the most popular in China, the and the , which localized the same format, differed at least in terms of viewership. Focusing on these two opposing cases, this study examines the characteristics and considerations of the localization transformation through in-depth interviews with experts in China.. As a result, was positive in terms of character diversification and online media interworking effects. However, the experts recognized that factors such as the confusion of character combinations due to frequent change of performers, frequent absences, conservative characteristics of Chinese state broadcasting that emphasized educational contents, and burden of localization due to changes in mission and challenge form each time were negatively affected. On the other hand, lacked the effect of online media interaction and lack of diversity of performers. However, the use of star actors' celebrities, the merits of actors with the characteristics of Chinese historical and cultural spaces, the use of Chinese flavors and fragrances, and similar types of missions and maintaining a stable composition each time favored localized production formats.

Characteristics of 23 MV Photon Beam from a Mevatron KD 8067 Dual Energy Linear Accelerator (Mevatron KD 8067 선형가속기의 23 MV 광자선의 특성)

  • Kim, Ok-Bae;Choi, Tae-Jin;Kim, Young-Hoon
    • Radiation Oncology Journal
    • /
    • v.8 no.1
    • /
    • pp.115-124
    • /
    • 1990
  • The characteristics of 23 MV photon beam have been presented with respect to clinical parameters of central axis depth dose, tissue-maxi mum ratios, scatter-maximum ratios, surface dose and scatter correction factors. The nominal accelerating potential was found to be $18.5\pm0.5$ MV on the central axis. The half-value layer (HVL) of this photon beam was measured with narrow beam geometry from central axis, and it has been showed the thickness of $24.5\;g/cm^2$. The tissue-maximum ratio values have been determined from measured percentage depth dose data. In our experimental dosimetry, the surface dose of maximum showed only $9.6\%$ of maximum dose at $10\times10\;cm^2$, 100 cm SSD, without blocking tray in. The TMR'S of $0\times0$ field size have been determined to get average $2.3\%$ uncertainties from three different methodis; are zero effective attenuation coefficient, non-ilnear least square fit of TMR's data and effective linear attenuation coefficient from the HVL of 23 MV photon beams of dual energy linear accelerator.

  • PDF

Effect of Fe2O3 Concentration in Coal Slag on the Formation of (Fe,Cr)3O4 in Chromia Refractory (크롬계 내화물에서 슬래그의 산화철 농도가 (Fe,Cr)3O4 형성에 미치는 영향)

  • Park, Woo Sung;Oh, Myongsook S.
    • Applied Chemistry for Engineering
    • /
    • v.18 no.5
    • /
    • pp.495-500
    • /
    • 2007
  • The inside wall of a coal gasifier is lined with refractory, and the corrosion of the refractory is an important factor affecting the refractory lifetime and the replacement period. This paper examines the changes in microstructure of a chromia refractory due to chemical reactions with slag having varying amounts of $Fe_2O_3$. Slag samples were prepared by adding $Fe_2O_3$ to KIDECO slag, and static corrosion experiments were carried out at $1550^{\circ}C$. The layer of $(Fe,Cr)_3O_4$ formation and the depth of Fe depletion in the infiltrating slag were determined. In addition, FactSage equilibrium calculations were carried out in order to determine the conditions of formation, and to compare with the experimental observations. In the sample exposed to KIDECO slag, which has about 10 wt% $Fe_2O_3$, the formation of $(Fe,Cr)_3O_4$ was not observed. As the $Fe_2O_3$ concentration in slag increased, $(Fe,Cr)_3O_4$ formation and Fe depletion depth increased. Increasing $Fe_2O_3$ concentration also made the slag/refractory interface indistinguishable. Equilibrium calculations predicted that higher $Fe_2O_3$ concentrations favor chromite formation at gasification temperatures. The chromite formation was most favorable when the amount of $Cr_2O_3$ was limited, as in the case of dissolved $Cr_2O_3$ in slag. When the concentration of $Fe_2O_3$ in slag was less than 20%, the formation of chromite was least favorable in the system with equal amounts of slag and refractory.

AN IN-VITRO WEAR STUDY OF INDIRECT COMPOSITE RESINS AGAINST HUMAN ENAMEL (법랑질에 의한 수종의 간접복합레진의 마모에 관한 연구)

  • Yi, Hyun-Jeong;Jeon, Young-Chan;Jeong, Chang-Mo;Jeong, Hee-Chan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.5
    • /
    • pp.611-620
    • /
    • 2007
  • Statement of problem: Second-generation indirect composite resins have been improved flexural strength, compressive strength, hydrolytic degradation resistance, wear resistance compared to first-generation indirect composite resins, but there are still some problems as hydrolysis and low wear resistance. Some manufacturers claim that wear resistance of their materials has been improved, but little independent study has been published on wear properties of these materials and the properties specified in the advertising materials are largely derived from in-house or contracted testing. Purpose: This study was to evaluate the wear of indirect composite resins (SR Adore, Sinfony, Tescera ATL) and gold alloy against the human enamel. Material and method: Extracted human incisors and premolars were sectioned to $2{\times}2{\times}2mm$ cube and embedded in the clear resin and formed conical shaped antagonist to fit the jig of pin-on-disk tribometer. Total 20 antagonists were stored in distilled water. Five disk samples, 24mm in diameter and 1.5mm thick, were made for each of three groups of indirect composite resins and gold alloy group, and polished to #2,000 SiC paper on auto-polishing machine. Disk specimens were tested for wear against enamel antagonists. Wear test were conducted in distilled water using a pin-on-disk tribometer under condition (sliding speed 200rpm contact load 24N, sliding distance 160m). The wear of the enamel was determined by weighing the enamel antagonist before and after test, and the weight was converted to volumes by average density. The wear tracks were analyzed by scanning electron microscopy and surface profilometer to elucidate the wear mechanisms. Statistical analysis of the enamel wear volume, wear track depth and wear tract width of disk specimens were accomplished with one-way ANOVA and the means were compared for significant differences with Scheffe's test. Results: 1. The enamel wear was most in gold alloy, but there were no statistically significant differences among all the groups (P>.05). 2. In indirect composite resin groups, the group to make the most shallow depth of wear tract was Sinfony, followed by Tescera ATL, SR Adoro (P<.05). Gold alloy was shallower than Sinfony, but there was no statistically significant difference between Sinfony and gold alloy (P>.05). 3. The width of wear tract of SR Adore was larger than the other groups (P<.05), and there were no statistically significant differences among the other groups (P>.05). 4. SEM analysis revealed that Sinfony and gold alloy showed less wear scars after test, Tescera ATL showed more wear scars and SR Adore showed the most. Conclusion: Within the limits of this study, Sinfony and gold alloy showed the least wear rates and showed similar wear patterns.

A Study on the Amendments of the Cathodic Protection Criteria Considering IR Drops (전압강하를 고려한 전기방식 기준 개정에 관한 연구)

  • Ryou, Young-don;Lee, Jin-han;Jo, Young-do;Kim, Jin-Jun
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.4
    • /
    • pp.50-57
    • /
    • 2016
  • According to the urban gas business legislation, cathodic protection systems should be applied for buried steel gas pipelines to prevent corrosion. In advanced countries including United States, the criteria for Cathodic Protection Potential is at least -850mV with respect to a saturated copper/copper sulfate electrode(CSE) when the CP applied, and the IR drops must be considered for valid interpretation. However, the IR drop through the pipe to soil boundary has been neglected in Korea. According to KGS code, a reference electrode must be placed in proximity to gas pipelines possible when measuring the CP potential. In this study, we have installed several solid reference electrodes around the buried pipeline(1.2m depth), lower surface(0.5m depth), and the surface individually in order to measure the CP potentials through the each reference electrode and find out the IR drops according to the location of each reference electrode. We have found the IR drop is the greatest when measuring the CP potential through the electrode placed on the ground and the IR drop is the smallest through the electrode installed near pipeline. Therefore, we have suggested the solid reference electrode should be installed as close as possible to buried pipeline in order to measure the correct CP potential without IR drop. We have also suggested the amendment of CP criteria considering IR drop.

A Study on the Analysis of Time-Regional Distribution of PRecipitation Frequency and Rainfall INternsity in Korea. (강수빈도 및 강우강도의 시공적 분포분석에 관한 연구)

  • 이재준;손광익
    • Water for future
    • /
    • v.14 no.4
    • /
    • pp.53-72
    • /
    • 1981
  • In this study, South Korea is divided into 5 zones and is studied about the analysis of time-regional distribution of previpitation frequency and rainfall intensity in Korea. In the previpitation frequency analysis, the basic data groups of 39 stations were selected. The diagram of previpitation frequency was drawn, and the time-regional distribution of precipitation frequency was analized. In the rainfall intensity analysis, the basic data groups of 36 stations were selected. The probable rainfall, I-D-F curve, and regression equation between 24hr. and 10min.-18hr. areal depth were obtained. The results of this study are following; 1) The precipitation class of max. recurrence probability in every season except summer was commonly (1) 1-5mm, (2) 0.1-1mm, (3) 5-10mm in order. 2) The zone of max. recurrence frequency owing to the precipitation class was zone II in precipitation frequency of below 20mm, zone IV in precipitation frequency of 30-40mm, zone I in precipitation frequency of above 70mm for a year. 3) The recurrence probability of precipitation in Korea can be represented to the equation of exponential function; $$W(x)=e^{\alpha+\beta}$$ 4) The first and third zones were expected heavy rain for the short and long duration. 5) The I.D.F. curves were drawn, and established that the time interval for the least deviation of I.D.F curve is 10~40min., 40min. -4hr., 4~24hr. 6) The regression equations of areal mean depth between 24hr. and 10min.-18hr. for each zone were obtained. 7)The probable rainfall of 36 points were calculated.

  • PDF