• Title/Summary/Keyword: leakage problems

Search Result 550, Processing Time 0.028 seconds

Low-operating voltage Pentacene FETs with High dielectric constant polymeric gate dielectrics and its hyteresis behavior

  • Park, Chan-Eon
    • Proceedings of the Polymer Society of Korea Conference
    • /
    • 2006.10a
    • /
    • pp.168-168
    • /
    • 2006
  • Low-operating voltage organic field-effect transistors (OFETs) have been realized with high dielectric constant (${\kappa}$) polymer such as cyanoethylated poly vinyl alcohol (CR-V, ${\kappa}=12$). Since the $high-{\kappa}$polymers are likely to contain water and ionic impurities, large hysteresis and considerable leakage current are frequently observed in OFETs. To solve these problems, we cross-linked the CR-V by using a cross-linking agent. Cross-linked CR-V dielectrics showed high dielectric constant of 11.1 and good insulating properties, resulting in a high capacitance ($81nF/cm^{2}$ at 1MHz) at 120 nm of dielectric thickness. Pentacene FETs with cross-linked CR-V dielectrics exhibited high carrier mobility ($0.72\;cm^{2}/Vs$), small subthreshold swing (185 mV/dec) and little hysteresis at low-operating voltage (${\Leq}-3V$).

  • PDF

Subaxillary Minithoracotomy for Treatment of Primary Spontaneous Pneumothorax (액와부 소절개를 통한 원발성 자연기흉의 치료)

  • 정성규
    • Journal of Chest Surgery
    • /
    • v.25 no.10
    • /
    • pp.1020-1024
    • /
    • 1992
  • Thirty-four patients underwent 39 subaxillary minithoracotomies for the treatment of primary spontaneous pneumothorax from June 1987 to April 1992. The age of patients ranged from 17 to 32 years. The ratio of male to female was 8.8: 1 with male predominance. The associated pulmonary lesions and pleural adhesion were not seen on the chest X-rays in all cases. Average operative time was 83 minutes[30~130 min]. Postoperative average duration of air leakage was 2.4 days, the chest tube indwelling was 5.1 days, and postoperative hospital stay was 8 days, Analgegics were not given for pain control postoperatively In conclusion, the subaxillary minithoracotomy has the following advantages: reducing the operative time, postoperative pain, morbidity, hospital stay, shoulder problems, and excellent cosmetic result.

  • PDF

Experimental Investigation of Thermal Stress Cracks in Mechanical Face Seals (기계평면시일의 열응력 크랙에 관한 실험적 연구)

  • 김청균
    • Tribology and Lubricants
    • /
    • v.12 no.3
    • /
    • pp.79-84
    • /
    • 1996
  • One of the greatest dangers in mechanical face seals is the formation of heat checking and thermal stress cracks on the sliding surfaces. These thermal distortions due to non-uniform heating lead to increase the leakage of the sealed fluids and wear, and with balance of the seal can cause the seal faces to part. In this study heat checking and thermal stress cracks are investigated experimentally. These thermal distortions are explained using the thermal models of the conatct geometries between the seal ring and the seal seat. To overcome these thermal problems, the thermohydrodynamic seal is presented. The newly developed mechanical seal may substantially reduce the friction torque, frictional heating which causes heat checking and thermal stress cracks, and wear.

A Characteristic Study of Efficiency in Radial Piston Pump (레이디얼 피스톤 펌프의 효율 특성 연구)

  • 장윤석;천세민;임윤철
    • Tribology and Lubricants
    • /
    • v.16 no.4
    • /
    • pp.259-265
    • /
    • 2000
  • Pump which is the fundamental device in the hydraulic system affects on overall system performance to a great deal. Such problems as leakage and solid friction loss become important in field applications, especially for the case of operation under high pressure and at high speed. So the research on this kind of subjects is necessary to improve the performance of hydraulic devices. A high pressure radial piston pump is analyzed here, which has a stationary cylinder block. It pumps hydraulic fluid by letting camring push a piston in a cylinder. Fluid leaks between the piston and cylinder so that it deteriorates the pump efficiency. Furthermore, the piston happens to touch the cylinder wall to increase the friction loss and wear. In this research, by means of FDA, volumetric, mechanical and overall efficiencies are observed by varying several design parameters and operation conditions. Design values or their trends are presented to improve these effciencies.

Extended Low Anterior Resection with a Circular Stapler in Patients with Rectal Cancer: a Single Center Experience

  • Talaeezadeh, Abdolhasan;Bahadoram, Mohammad;Abtahian, Amin;Rezaee, Alireza
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.18
    • /
    • pp.8141-8143
    • /
    • 2016
  • Background: to evaluate the outcome of stapled colo-anal anastomoses after extended low anterior resection for distal rectal carcinoma. Materials and Methods: A retrospective study of fifty patients who underwent coloanal anastomoses after extended low anterior resection was conducted at Imam Hospital from September 2007 up to July 2012. Results: The distance of the tumor from anal verge was 3 to 8 cm. Anastomotic leakage developed in 6% of patients and defecation problems in 16%. One-year local recurrence was 6% while three-year local recurrence was 4%. One-year systemic recurrence was seen in 22% while three-year systemic recurrence was seen in 20%. Conclusions: Colo-anal anastomoses after extended low anterior resection for distal rectal carcinoma can be conducted safely.

Performance Estimation of Tunnel Lining Concrete Reinforced Steel Fiber (강섬유 보강 터널 라이닝 콘크리트의 성능 평가)

  • Jeon, Chan-Ki;Kim, Su-Man;Lee, Myung-Soo;Lee, Jong-Eun;Jeon, Joong-Kyu
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.579-582
    • /
    • 2005
  • Tunnel lining is the final support of a tunnel and reflects the results of the interaction between ground and support system. Recently it is very difficult to support and manage the tunnel because the cracks on tunnel lining cause problems in supporting and managing tunnels. Therefore the analysis of the cracks is quite strongly required. The major role played by the steel fiber occurs in the post-cracking zone, in which the fibers bridge across the cracked matrix. Because of its improved ability to bridging cracks, steel fiber reinforcement concrete(SFRC) has better crack properties than that of reinforced concrete. In this study, mechanical behaviour of a tunnel lining was examined by model tests. The model tests were carried out under various conditions taking different loading shapes, thicknesses and leakage of lining, and volume content of steel fiber. From these model test, the cracking load, the failure load, defection and cracking position and type were examined and the characteristics of deformation and failure for tunnel lining were estimated and researched.

  • PDF

When mend piercing crack of large size mat basis, study of perforation and vottom repair that use water jet (대형매트기초의 관통균열 보수시 WATER JET을 이용한 천공과 저면보수에 관한 연구)

  • 박성우;한송수;이상헌;박찬규
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.577-580
    • /
    • 2003
  • Problem of repairing by boring is that it deteriorates stabelety and durability of structure by permeation of seawater from underneath after damage and repair of reinforcing rod regarding of spot. The purpose of this study is to improve the porblem by using the repair method of general boring to mend the of large mat basis. Direction of thes experiment is to apply the new repair material and the method to control the blazing fire factor caused by the crack from the foundation of large mat and also to estimate it's integrity. New method of construction is method of contruction that do speace scurity in vertical drilling and bottom useing water jet. New material used bantonite and rubberized asphalt. Test result existent repair method of construction large size mat basis perforation is difficult and reinforcing rod can be damaged coule there were a lot of problems with re-water leakage of crack repair region, but overcomes existent short coming by method that apply in this study.

  • PDF

An Efficient Medical Information Authentication Scheme in Mobile Cloud Environment (모바일 클라우드 환경에서 효율적인 의료정보 인증 기법)

  • You, Mi-kyeong;Woo, Sung-hee
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.05a
    • /
    • pp.721-723
    • /
    • 2015
  • Recently importance and scalability of cloud computing technology is rapidly emerging, it tends to have applied to various information systems. Many services have been made in mobile cloud environment, and medical information service quick application is required. When the medical information is important information of individuals to leakage, because you can cause serious problems, the problem of secure authentication procedures must be resolved. Therefore, in this paper, we propose an authentication scheme that can be more efficiently manage the medical information system in a mobile cloud environment.

  • PDF

The Single Phase Converter of Power Factor Collection Type with Simple Switching Method (간이 스위칭법에 의한 단상 역률개선형 컨버터)

  • 문경희;고강훈;김은수;곽동걸;조판제;이현우
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.323-326
    • /
    • 1999
  • For decrease the harmonic current components of the power source, a first method is insert the choke coil that used the choke input type rectifier, the booster chopper circuit and buck chopper circuit. And the several method are studying like as the PWM(Pulse Width Modulation) converter and the active filter type which is used the high frequency switching and the sinusoidal wave formed input current. In this type, there are many problem as a low efficiency, increased the noise, the high leakage current and cost up by the high frequency switching. For improve this problems, the partial resonan method is used on the booster inducter and lossles snubber condenser. This method decreased the distortion factor has lower harmonic components than the hard switching and there is no switching loss by the ZCS(Zero Current Switching) at switch turn-on and the ZVS(Zero Voltage Swithcing) at switch turn-off

  • PDF

Excimer Laser-Assisted In Situ Phosphorus Doped $Si_{(1-x)}Ge_x$ Epilayer Activation

  • Bae, Ji-Cheul;Lee, Young-Jae
    • ETRI Journal
    • /
    • v.25 no.4
    • /
    • pp.247-252
    • /
    • 2003
  • This paper presents results from experiments on laser-annealed SiGe-selective epitaxial growth (LA-SiGe-SEG). The SiGe-SEG technology is attractive for devices that require a low band gap and high mobility. However, it is difficult to make such devices because the SiGe and the highly doped region in the SiGe layer limit the thermal budget. This results in leakage and transient enhanced diffusion. To solve these problems, we grew in situ doped SiGe SEG film and annealed it on an XMR5121 high power XeCl excimer laser system. We successfully demonstrated this LA-SiGe-SEG technique with highly doped Ge and an ultra shallow junction on p-type Si (100). Analyzing the doping profiles of phosphorus, Ge compositions, surface morphology, and electric characteristics, we confirmed that the LA-SiGe-SEG technology is suitable for fabricating high-speed, low-power devices.

  • PDF