• 제목/요약/키워드: leakage of dye

검색결과 149건 처리시간 0.023초

단일 단계 접착제의 변연 미세누출 (MARGINAL MICROLEAKAGE OF SINGLE STEP ADHESIVES)

  • 조영곤;정진호;기영재;최희영;진철희;유상훈;김종욱;박병철
    • Restorative Dentistry and Endodontics
    • /
    • 제29권2호
    • /
    • pp.162-169
    • /
    • 2004
  • This study evaluated the marginal microleakage of five single step adhesives. Class V cavity preparations with occlusal margins in enamel and gingival margins in dentin were prepared on both buccal and lingual surfaces of extracted human molar teeth. Prepared teeth were randomly divided into five groups and restored using one of the single step adhesives and composite resins:Prompt L-Pop/Filtek Z-250 (Group 1), AQ Bond/Metafil CX (Group 2), One-Up Bond F/Palfique Toughwell (Group 3). Futurabond/Admira (Group 4), Xeno III/Spectrum TPH (Group 5). The restored teeth were thermocycled. Microleakage was assessed by dye penetration using 2% methylene blue dye solution. The teeth were bisected buccolingually and evaluated for microleakage under steromicroscope. The data were statistically analysed by Kruskal-Wallis test and Mann-Whitney tests. The results of this study were as follows:1. Microleakage of enamel margins in group 3 was statistically higher than that in groups 1, 2, 4, 5 (p < 0.05). 2. Microleakage of dentin margins in group 1 was statistically higher than that in groups 2, 5, and that in group 3 was statistically higher than that in groups 2, 4, 5 (p < 0.05). 3. Dentin marginal microleakage was higher than enamel marginal microleakage in all experimental groups. In conclusion, Prompt L-Pop showed the least leakage at enamel margin, and AQ Bond showed at dentin margin in this study. Marginal miroleakage in dentin was higher than that in enamel.

다양한 방식으로 적용한 이장재가 2급와동 복합레진 수복의 미세누출에 미치는 영향 (Effect of lining application techniques on microleakage in class II composite restorations)

  • 황병문;김주형;박지만;;박은진
    • 구강회복응용과학지
    • /
    • 제30권2호
    • /
    • pp.145-151
    • /
    • 2014
  • 목적: 본 연구는 두가지 다른 방법에 의한 레진강화형 글래스 아이오노머(RMGI) 이장재의 적용이 2급와동 복합레진수복의 미세누출에 미치는 영향을 조사하고자 하였다. 연구 재료 및 방법: 36개의 발치한 치아에 2급 와동을 형성한 뒤 무작위로 3개의 군으로 나누었다. 1군은 대조군으로 이장재를 적용하지 않았으며, 2군은 치과용 탐침으로 RMGI 이장재 적용, 3군은 특별히 고안된 버로 RMGI 이장재를 적용한 뒤 복합레진은 똑같이 통상적인 방법으로 적층수복하였다. 2% 메틸렌 블루 염색한 뒤 치아장축과 평행하게 순설 방향으로 절단하여 미세누출을 현미경과 컴퓨터 프로그램을 사용하여 분석을 하였다. 데이터는 Kruskal-Wallis test와 Mann-Whitney U-test (P < 0.05)로 분석하였다. 결과: RMGI 이장재가 적용된 군은 그렇지 않은 군보다 월등히 적은 미세누출을 보였으며, 특히 특수 고안된 버를 사용한 군의 50%에서는 전혀 미세누출을 보이지 않았다. 그러나, 2군과 3군의 결과에서 통계적으로 유의한 차이는 관찰되지 않았다. 결론: 2급와동의 복합레진 수복에서 RMGI 이장재는 그 적용 방법에 관계없이 미세누출을 감소시키는데 효과적인 재료이다.

치근단 역충전와동의 건조방법이 폐쇄성에 미치는 영향 (INFLUENCES OF DRY METHODS OF RETROCAVITY ON THE APICAL SEAL)

  • 이정태;김성교
    • Restorative Dentistry and Endodontics
    • /
    • 제24권1호
    • /
    • pp.166-179
    • /
    • 1999
  • 외과적 근관치료에서 근단부의 폐쇄성은 성공에 필수적이다. 그리고 외과적 근관치료시 근단부 역충전와동은 습기나 혈액에 의해 오염되기 쉬우며 와동을 이상적으로 건조하기가 항상 용이하지는 않다. 본 연구의 목적은 미세 치근단 수술법에서 치근단 역충전와동의 건조 방법이 폐쇄성에 미치는 영향을 연구하고자 함이다. 치근단 폐쇄성은 근단 누출 및 충전물-와벽 적합성으로 평가하였다. 치근단 역충전와동 건조방법에 따른 치근단 누출을 평가하기 위해서는 최근에 발거된 상악 대구치 구개측치근 125개를 와동건조 방법 및 혈액오염에 따라 4개의 군으로 분류하여 실험하였다. 각 시편치아에서 근관을 형성하고 측방가압법으로 충전한 후 각 군에 따라 저속 다이아몬드 절단기를 이용하여 치근단 3 mm를 절제하였으며 초음파 스테인레스 스틸 기구를 이용하여 깊이 3mm의 역충전 와동을 형성하고 IRM, Super EBA 또는 복합레진으로 역충전하였다. 시편을 2% methylene blue 용액에 7일간 침잠시킨 후 35% 질산 용액에서 용해시킨 다음, 원심분리한 상층액을 비색계를 이용하여 누출 색소의 흡광도를 측정하였다. 결과치는 이원변량분석법과 Duncan's Multiple Range Test를 이용하여 분석하였다. 역충전 와동 건조방법에 따른 충전물-와벽 적합성을 평가하기 위해서는 상악 제 1대구치의 구개측 치근 12개를 상기와 같이 4개 군으로 분류하여 근관충전, 역충전와동 형성, 와동 건조 및 역충전을 실험하였으며, 다음과 같은 결과를 얻었다. 1. 압축공기나 paper point로 와동을 건조한 군이, 역충전 와동을 IRM 간이충전재, Super EBA 시멘트 및 복합레진으로 충전한 경우 공히, cottton pellet 만으로 와동을 건조한 군에 비해 적은 치큰단 누출을 나타내었는데 이는 Super EBA 시멘트 충전군에서만 유의한 차이를 나타내었다(p<0.05). 그러나 충전재료에 관계없이 paper point로 와동을 건조한 군과 압축공기로 건조한 군 사이에는 유의한 누출의 차이가 나타나지 않았다. 2. 압축공기로 와동을 건조한 경우에는, 복합레진으로 충전한 군이 IRM이나 Super EBA로 충전한 군에 비해 유의하게 적은 치근단 누출을 나타내었다(p<0.05). 3. 와동을 혈액으로 오염시킨 경우에는, 역충전 와동을 IRM, Super EBA 및 복합레진으로 충전한 군 공히, 압축공기로 와동내부를 건조한 경우에 비해 유의하게 많은 치큰단 누출을 나타내었다(p<0.05). 4. IRM 간이충전재나 Super EBA 시멘트로 역충전와동을 충전한 경우, 와동측벽의 외측 1/2이 내측 1/2에 비해 넓은 충전물-치질 사이 틈을 나타내었다. 5. IRM 간이충전재, Super EBA 시멘트 및 복합레진으로 역충전와동을 충전한 경우 공히, 와동이 혈액에 의해 오염되었거나 와동을 cotton pellet으로만 건조한 경우가 paper point나 압축공기로 와동을 건조한 경우에 비해 와동기저부에 큰 틈을 나타내는 양상을 보였다.

  • PDF

흉부둔상에 의한 식도파열의 성공적인 보존적 치료 (A successful conservative management of traumatic thoracic esophageal rupture)

  • 노태훈
    • Journal of Chest Surgery
    • /
    • 제21권1호
    • /
    • pp.169-174
    • /
    • 1988
  • Thoracic esophageal rupture caused by blunt trauma is often not recognized until late because of the vague symptoms in the initial state as well as its rare incidence, which can easily lead to fulminant mediastinitis with frequent fatal outcome. Once extensive mediastinitis occurs, the primary surgical repair of the esophageal tear is considered to be practically impossible. Various methods have been proposed for the management of these desperately ill patients, but no one provides an acceptable good result yet. The purpose of this article is to report the successful result obtained in the treatment of a patient with fulminant mediastinitis from traumatic esophageal rupture by continuous transesophageal irrigation. A 27 year-old male patient was brought to the emergency room of our hospital complaining of dyspnea and chest pain after blunt trauma. The diagnosis of esophageal rupture in the thorax was made late, about 46 hours after the initial injury, when mediastinitis had already progressed. The transesophageal irrigation method was immediately instituted which consisted of profuse transesophageal irrigation of the mediastinum with orally ingested fluid and/or by Levin tube, positioned proximal to the site of the rupture, and drainage of the irrigation fluid by thoracoscopically accurately positioned chest tubes connected to a well suctioning system. With subsiding inflammatory signs and symptoms, the esophagogram, obtained 54 days after the treatment, showed no evidence of the mediastinal leakage of contrast material which contrasted previous esophagograms with definitive dye collections in the mediastinum. Additional endoscopic finding confirmed complete healing of the esophageal mucosa, previously ruptured. He has been followed up without any problem until recently, 6 months after discharge.

  • PDF

생약복합제제(生藥複合製劑)의 약효연구(藥效硏究)(제34보)(第34報) -청심정천탕(淸心定喘湯)이 항히스타민작용 및 호흡기계에 미치는 영향- (Studies on the Efficacy of Combined Prepartion of Crude Drugs(XXXIV) -Effects of Chungsimjeongchun-Tang on the Anti-histamine Action and Respiratory System-)

  • 홍남두;이경섭;김남재;김길수;곽재욱
    • 생약학회지
    • /
    • 제18권4호
    • /
    • pp.233-240
    • /
    • 1987
  • In order to investigate experimentally the clinical effects of Chungsimjeongchun-Tang that have been widely used for cardiac asthma, dyspnea and coughs secondary to the appoplexy and cardiac diseases, the water extract of Chungsimjeongchun-Tang was conducted to the effects on the anti-histamine action and respiratory system in mice, guinea-pigs, rabbits and cats. The following results of Chungsimieongchun-Tang were obtained. Spontaneous motility of the isolated ileum of mice and rabbits was strongly suppressed and contractions of the isolated ileum of mice and guinea-pigs induced by acetylcholine chloride, barium chloride and histamine were remarkably inhibited. Anti-histamine action was noted. Antitussive action on the mechanically irritative cough in cats was recognized. Expectorant action on the leakage of dye in the respiratory tract of rabbits was also shown.

  • PDF

갈륨과 아말감 수복물의 변연미세누출에 관한 비교 연구 (COMPARISON OF MICROLEAKAGE OF GALLIUM ALLOY AND AMALGAM RESTORATION)

  • 이민호;이희주;허복
    • Restorative Dentistry and Endodontics
    • /
    • 제23권1호
    • /
    • pp.269-277
    • /
    • 1998
  • This in vitro study compared the microleakage of 4 lining conditions when used with Gallium alloy GF II and Valiant PhD. Class V cavity was prepared on both buccal and lingual surface of 80 extracted human premolar & molar teeth with one margin in enamel and another in dentin. Before restoration, prepared cavities were applied to no-liner, cavity varnish, Scotchbond multipurpose, and Superbond D-liner II plus according to manufacture's instructions. The restored teeth were stored in saline for 1 week, then thermocycled for 100 times, stained with 0.5% basic fuchsin dye for 1 day, sectioned, and observed using a light microscope. Following results were obtained. 1. The leakage value of Superbond-lined group showed significantly lower than that of nolined group on both margins of Valiant PhD(p<0.05). 2; There was no significant difference between the 4 lining conditions in Gallium alloy GF II (p>0.05). 3. When We make a comparison between Gallium alloy GF II and Valiant PhD under same lining conditions, the microleakage value of Gallium alloy GF II showed lower than that of Valiant PhD on occlusal & gingival margin(p<0.05) except for Superbond-lined group(p>0.05).

  • PDF

Fabrication of Flexible Solid-state Dye-sensitized $TiO_2$ Nanotube Solar Cell Using UV-curable NOA

  • 박익재;박상백;김주성;진경석;홍국선
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제43회 하계 정기 학술대회 초록집
    • /
    • pp.396-396
    • /
    • 2012
  • $TiO_2$ anatase nanotube arrays (NTAs) were grown by electrochemical anodization and followed annealing of Ti foil. Ethylene glycol/$NH_4F$-based organic electrolyte was used for electrolyte solution and using second anodization process to obtain free-standing NTAs. After obtaining NTAs, ITO film was deposited by sputtering process on bottom of NTAs. UV-curable NOA was used for attach free-standing NTAs on flexible plastic substrate (PEN). Solid state electrolyte (spiro-OMeTAD) was coated via spin-coating method on top of attached NTAs. Ag was deposited as a counter electrode. Under AM 1.5 simulated sunlight, optical characteristics of devices were investigated. In order to use flexible polymer substrate, processes have to be conducted at low temperature. In case of $TiO_2$ nano particles (NPs), however, crystallization of NPs at high temperature above $450^{\circ}C$ is required. Because NTAs were conducted high temperature annealing process before NTAs transfer to PEN, it is favorable for using PEN as flexible substrate. Fabricated flexible solid-state DSSCs make possible the preventing of liquid electrolyte corrosion and leakage, various application.

  • PDF

KAVO ISTHMUS, KAVO T-SHAPE과 KIS TIP의 3종 초음파기구로 형성한 역충전와동의 SUPEREBA 변연누출에 관한 연구 (Leakage of SuperEBA in root-end cavities prepared with 3 new ultrasonic tips : KaVo Isthmus, KaVo T-shape and KiS tip)

  • 이우철
    • Restorative Dentistry and Endodontics
    • /
    • 제27권3호
    • /
    • pp.270-276
    • /
    • 2002
  • 치근단 수술시 구동형 수술현미경과 미세수술기구들이 사용됨에 따라 치근단 절제술 후 역충전와동의 효과적인 형성 및 충전을 위해 새로운 초음파기구가 개발되었다 따라서 본 연구에서는 최근 상품화되어 사용되고 있는 초음파기구중 신속하게 역충전와동을 형성할 뿐아니라 충분한 깊이를 제공하여 역충전재료의 변연누출 감소에 효과적인 것으로 알려져 있는 3종의 초음파기구를 사용하여 역 충전와동을 형성 한 후 SuperEBA로 충전하여 그 변연누출을 비교하였다. 모두 56개의 근첨형성이 완료된 단근치를 선택하여 Profile .06를 사용하여 근관형성한 후 음성대조군 2개를 제외한 54개의 치아를 수직가압법으로 충전하였다. 근단부 3mm를 절제한 뒤 KaVo Isthmus, KaVo T-shape 그리고 KiS tip을 각각 18개의 치아에 사용하여 역충전와동을 형성하고 그중 각각 2개의 양성대조군 치아를 제외한 나머지 치아에 SuperEBA로 충전하였다. 각치아는 1% methylene blue dye에 침윤시켜 1주일 후 종절단하여 그 색소침투정도를 측정, 비교하였다. 실험결과 측정된 평균 변연누출은 KaVo Isthmus가 $1.5\pm$1.4mm, KaVo T-shape이 1.7$\pm$1.2mm이고 KiS tip은 1.1$\pm$0.7mm 이었으며, 통계적으로 유의할만한 차이는 없었다. 따라서 초음파기구를 사용한 역충전와동의 임상시술 성공여부는 술자의 편의도와 임상적 사용시 조작능력에 달려 있는 것으로 사료된다.

백악질 변연을 갖는 2급 와동에 충전된 4종 복합레진의 미세누출 (MICROLEAKAGE OF 4 DIFFERENT COMPOSITE RESIN RESTORATIONS IN CLASS II CAVITY WITH CEMENTAL MARGIN)

  • 조영곤;한세희;김은성
    • Restorative Dentistry and Endodontics
    • /
    • 제26권6호
    • /
    • pp.492-498
    • /
    • 2001
  • The purpose of this study was to evaluate four different composite resins in vitro for microleakage in Class II box type restorations that have gingival margins apical to the cementoenamel junction. Forty caries free extracted human molars were used in this study. The Class II cavities were prepared 1.0mm below cementoenamel junction with a #701 carbide bur. The teeth were randomly divided into four groups, each group comprising 20 treated cavities according to adhesives and filling materials ; Group 1: Scotchbond Multipurpose/Z 100. Group 2: Ariston Liner/Ariston pHc, Group 3: One Step/Pyramid, Group 4: Prime & Bond NT/SureFil. To simulate the clinical situation during restoration placement, a restoration template was fabricated and composite resin was filled using a three sited light-curing incremental technique. The specimens were stored in the 100% humidity for 7 days prior to thermocycling. The specimens were immersed in 2% methylene blue dye solution for 24 hours and then embeded in transparent acrylic resin and sectioned mesiodistally with a diamond wheel saw. The degree of marginal leakage was scored under the stereomicroscope($\times$20) and the data were analyzed by Kruskal Wallis test and Mann Whitney test. (omitted)

  • PDF

복합레진 수복시 상아질 표면 처리가 미세 변연 누출에 미치는 영향에 관한 연구 (THE EFFECT OF MOISTENING OF ETCHED DENTIN AND ENAMEL SURFACE ON THE MICROLEAKAGE OF COMPOSITE RESINS)

  • 전철민;권혁춘;이정식;이명종;엄정문
    • Restorative Dentistry and Endodontics
    • /
    • 제21권1호
    • /
    • pp.321-338
    • /
    • 1996
  • The purpose of this study was to evaluate the effect of moistening and air-drying of acid conditioned dentin and enamel on the marginal microleakage. In this study, Class V cavity were prepared on both buccal and lingual surface of sixty extracted human premolars with cementum margin. These specimens were randomly devided into three groups and three dentin adhesives(Scotchbond Multi-Purpose, All bond 2, Prisma Universal Bond 3) were applied to each group. The specimens in each group were subdevided into four groups (Wet/primed, Dry/primed, Wet/not primed, Dry/not primed) and the etched dentin and enamel surface were treated these four surface treatments prior to the placement of a bonding agent or adhesive. Wet/primed group was simply blot-dried with a damp facial tissue before primer placement ; Dry/primed group was air dried for 30 seconds before the placement of a primer ; Wet/not primed group and Dry/not primed group were not primed after blot dried and air dried for 30 seconds each group. The bonding agent and composite resin were applied for each group. All specimens were exposed to 500 cycle of thermal stress. Specimens were placed in a silver nitrate solution and then sectioned buccolingually through the center of the restoration. The dye penetrations of the specimens were observed with a stereo microscope. The statistical test were applied to the results using a one way analysis variance (ANOVA) and Duncan's multiple range test. The aspects of silver ion penetration into the resin/dentin interface were examined under scanning electron microscopy. The results were as follows. 1. In all groups, the enamel margin showed significantly lower leakage value than the cementum margin (p<0.05). 2. Regardless of various surface treatment and dentin adhesives, there was no significant difference at the enamel margins (p>0.05). 3. At the dentin margins, the leakage values of Dry/not primed group showed significantly higher than that of the other groups (p<0.05). The leakage values of Wet/primed group showed significantly lower than that of the other groups, but, there was no significant difference between Wet group and Dry group. 4. There was no significantly difference between the dentin adhesives regarding the surface treatments in all groups(p>0.05). 5. On the backscatterd scanning electron microscopy observation, the penetration of the silver ion occured at the bonding resin/dentin interface. In the Wet/primed group, resindentin hybrid zone and resin penetration into the dentin was observed. The resin tags were compactively formed to a thickness of $3\sim4{\mu}m$ at the upper part of dentinal tubules. In the Dry/primed group, the thickness of the hybrid zone and the diameter, depth of the resin tags diminished. In the Non-primed groups, the hybrid zone was not identified and few resin tag was observed. There was the gap formation in the resin/dentin interface.

  • PDF