• Title/Summary/Keyword: leakage detection

Search Result 457, Processing Time 0.03 seconds

Development and Safety Estimation of Resistive Leakage Current(Igr) of Detection Outlet (저항성 누설전류(Igr) 검출 콘센트의 개발 및 안전성 평가)

  • Kim, Chang-Soung;Hanh, Song-Yop;Choi, Chung-Seog
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.2
    • /
    • pp.221-226
    • /
    • 2009
  • In this paper, we analyzed form of flowing leakage current in electrical installation. Leakage current ($I_g$) is consisted of resistive leakage current($I_{gr}$), capacitive leakage current($I_{gc}$), and inductive leakage current($I_{gl}$). Resistive leakage current($I_{gr}$) is big occasion than capacitive leakage current($I_{gc}$) in system, Residual Current Protective Device(RCD) detects correctly leakage current. But,$I_{gc}$ is big occasion than $I_{gr}$, RCD is malfunctioned It is resistance to lead to electric fire in electrical device. We manufactured outlet that resistive leakage current detecting circuit is had. Manufactured outlet displayed performance exactly in leakage current of 5 mA Therefore, this product estimates that contribute on electric fire courtesy call.

Estimation of Probability Density Functions of Damage Parameter for Valve Leakage Detection in Reciprocating Pump Used in Nuclear Power Plants

  • Lee, Jong Kyeom;Kim, Tae Yun;Kim, Hyun Su;Chai, Jang-Bom;Lee, Jin Woo
    • Nuclear Engineering and Technology
    • /
    • v.48 no.5
    • /
    • pp.1280-1290
    • /
    • 2016
  • This paper presents an advanced estimation method for obtaining the probability density functions of a damage parameter for valve leakage detection in a reciprocating pump. The estimation method is based on a comparison of model data which are simulated by using a mathematical model, and experimental data which are measured on the inside and outside of the reciprocating pump in operation. The mathematical model, which is simplified and extended on the basis of previous models, describes not only the normal state of the pump, but also its abnormal state caused by valve leakage. The pressure in the cylinder is expressed as a function of the crankshaft angle, and an additional volume flow rate due to the valve leakage is quantified by a damage parameter in the mathematical model. The change in the cylinder pressure profiles due to the suction valve leakage is noticeable in the compression and expansion modes of the pump. The damage parameter value over 300 cycles is calculated in two ways, considering advance or delay in the opening and closing angles of the discharge valves. The probability density functions of the damage parameter are compared for diagnosis and prognosis on the basis of the probabilistic features of valve leakage.

A New Approach to On-Line Monitoring Device for ZnO Surge Arresters

  • Lee Bok-Hee;Gil Hyoung-Jun;Kang Sung-Man
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.5C no.3
    • /
    • pp.131-137
    • /
    • 2005
  • This paper describes a new approach to the algorithm and fundamental characteristics of the device for monitoring the leakage currents flowing through zinc oxide (ZnO) surge arresters. In order to obtain a technique for a new on-line monitoring device that can be used in the deterioration diagnosis of ZnO surge arresters, the new algorithm and on-line leakage current detection device for extracting the resistive and capacitive currents using the phase shift addition method were proposed. The computer-based on-line monitoring device can sense accurately the power frequency leakage currents flowing through ZnO surge arresters. The on-line leakage current monitoring device of ZnO surge arresters proposed in this work has the high sensitivity compared to the third harmonic leakage current detection devices. As a consequence, it was found that the proposed leakage current monitoring device would be useful for forecasting the defects and degradation of ZnO surge arresters.

Detection Framework for Advanced and Persistent Information Leakage Attack (지능적이고 지속적인 정보유출 공격 탐지 프레임워크)

  • Kil, Ye-Seul;Jeon, Ga-Hye;Lee, Il-Gu
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.05a
    • /
    • pp.203-205
    • /
    • 2022
  • As digital transformation and remote work environment advanced by Covid-19 become more common, the scale of leakage damage to industrial secrets and personal information caused by information leakage attacks is increasing. Recently, advanced and persistent information leakage attacks have become a serious security threat because they do not quickly leak large amounts of information, but continuously leak small amounts of information over a long period of time. In this study, we propose a framework for detecting advanced and persistent information leakage attacks based on traffic characteristics. The proposed method can effectively detect advanced and persistent information leakage attacks using traffic patterns, packet sizes, and metadata, even if the payload is encrypted.

  • PDF

Applicability of Geophysical Prospecting for water leakage detection in water utilization facilities (수리시설물의 누수탐지를 위한 물리탐사의 적용성)

  • Park Sam-Gyu;Song Sung-Ho;Choi Jong-hak;Choi Bo-Gyu;Lee Byoung-Ho
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2002.09a
    • /
    • pp.179-195
    • /
    • 2002
  • This paper examined the applicability of geophysical prospecting for water leakage detection of the water utilization facilities. Electrical resistivity survey and spontaneous-potential survey were carried out for the water leakage detection of dike and embankment, and the applicability was confirmed from many case studies. However, in order to efficiently maintain and detection of the more accurate water points in the embankment, the efficiently maintain and detection of the more accurate water leakage points in the embankment, the requirements are as follows; 1) It is necessary to use the electrical resistivity survey jointly with the spontaneous-potential survey in order to improve the reliability of water leakage information. 2) It is important to understand physical properties of the soil which influences the electrical resistivity of embankment in order to accurately grasp the water leakage points from the result of the electrical resistivity survey. 3) It is necessary to introduce the three-dimensional prospecting in order to improve the reliability of the measured value. 4) Introductions of the monitoring measurement system are necessary in order to efficiently and economically maintain of the water utilization facilities.

  • PDF

Improvement in Probability of Detection for Leakage Magnetic Flux Methods (누설자속탐상법의 결함검출능력 향상에 관한 연구)

  • Lee, Jin-Yi
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.13-18
    • /
    • 2004
  • It is important to estimate the distribution of intensity of a magnetic field for application of magnetic method to industrial nondestructive evaluation. Magnetic camera provides the distribution of a quantitative magnetic field with homogeneous lift-off and same spatial resolution. Leakage magnetic flux near the crack on the specimen could be amplified by 3-dimensional magnetic fluid and zoom in and out of measurement area. This study introduces the experimental consideration of the effects of lens for concentrating of magnetic flux. The experimental results showed that the magnetic fluid has sufficient lens effect for magnetic camera and effect of improvement in probability of detection.

  • PDF

Preliminary Analysis of a Sampling and Transportation System for Leak Detection during Steam Leak Accident of a Pipe in Nuclear Power Plants (원전 내 배관의 증기 누설 사고 시 누설 탐지 포집/이송 시스템 예비 해석)

  • Choi, Dae Kyung;Choi, Choengryul;Kwon, Tae-Soon;Euh, Dong-Jin
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.16 no.2
    • /
    • pp.25-34
    • /
    • 2020
  • As leakage in nuclear power plants could cause a variety of problems, it is very critical to monitor leakage from the safety point of view. Accordingly, a new type of leak detection system is currently being developed and flow characteristics of the sampling and transportation system are investigated by using numerical analysis as a part of the development process in this study. The results showed that the steam mass fraction varied according to the effect of the gap between the insulation and piping component, transportation velocity, and material properties of porous media during the sampling and transportation process. The results of this study should be useful for understanding flow characteristics of the sampling and transportation system and its design and application.

Effects of Adjacent Channel Leakage on an Energy Detection Based Spectrum Sensing (인접 채널 누설이 에너지 검파 기반 스펙트럼 센싱에 미치는 영향)

  • Lim, Chang Heon;Kim, Hyung Jung;Kim, Chang Joo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.5
    • /
    • pp.542-547
    • /
    • 2014
  • When a primary user transmits over some frequency band assigned to it, most of its transmission power tends to be concentrated in the band but a small portion of it spreads into the adjacent bands. Thus the false alarm probability for the adjacent bands can be higher than expected, even though no primary users are active in the bands. A previous work evaluated the effects of the adjacent channel leakage on the performance of an energy detection based spectrum sensing but it did not take into account the fading phenomenon. In this paper, we analyze the effects of the adjacent channel leakage on an energy detection based spectrum sensing scheme in terms of detection probability and false alarm probability in a fading environment.

A Study on the Development of Optical-Fiber Water Leakage Sensing System (광파이버 누수센싱 시스템 개발에 관한 연구)

  • Kim, Y.B.
    • Journal of Power System Engineering
    • /
    • v.16 no.6
    • /
    • pp.86-91
    • /
    • 2012
  • A multi purpose environmental monitoring system has been developed as a commercially available standard using the techniques which are FBG(Fiber Bragg Grating), Hetero-core spliced fiber optic sensor and etc, for the purposes of monitoring large scaled structures and preserving natural environments. The monitoring system has been tested and evaluated in a possible outdoor condition in view of the full scaled operation at actual sites to be monitored. Additionally, the developed systems in the previous works conveniently provided us with various options of sensor modules intended for monitoring such physical quantities as displacement, distortion, pressure, binary states, and liquid adhesion. In this paper, we extend the previous results to a water leakage detection problem and develop a sensing system as a result. By the experimental study, it is verified that multi-point leakage detection is possible using single line optical fiber.

Analysis of the Leakage Impulse Current in Faulty Insulators for Detection of Incipient Failures (절연물의 초기사고 감지를 위한 누설 임펄스 전류의 해석)

  • Kim, Chang-Jong;Lee, Heung-Jae;Sin, Jeong-Hun
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.8
    • /
    • pp.390-398
    • /
    • 2000
  • Leakage impulse current of the contaminated insulators by using experiment data were studied. The impulse current in phase-time relationship was analyzed on line post insulators. Also, frequency components and crest factor of the leakage current were investigated to provide a scheme for an early detection of insulator incipient failure. The study shows that the phase-time characteristic is non-stationary and random and, non-harmonic component and crest factor can be promising parameters for detecting insulator leakage currents.

  • PDF