• Title/Summary/Keyword: leak test

Search Result 255, Processing Time 0.026 seconds

An Experimental Study of a Diffuser Test Rig for Simulating High-Altitude Environment by using Hot (고온 연소가스를 이용한 고공 환경 모사용 디퓨저 실험장치 연구)

  • Yang, Jae-Jun;Lee, Yang-Suk;Kim, Yoo;Ko, Young-Sung;Kim, Yong-Wook;Kim, Chun-Taek
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.31-34
    • /
    • 2007
  • Performance tests of supersonic exhaust diffuser were conducted by using hot combustion gas for simulating high-altitude environment. The test rig consists of a combustion chamber, a vacuum chamber, water cooling ring and diffuser. Before combustion experiments, the preliminary leak tests were carried out on the liquid rocket engine and diffuser by using high pressure nitrogen(30barg) and a vacuum pump. The leak test results showed that there was no leaks at high pressure and vacuum pressure conditions.

  • PDF

Evaluation of Structural Safety and Leak Test for Hydrogen Fuel Cell-Based Truck Storage Systems (수소트럭 수소저장시스템에 대한 구조안전성 및 기밀성능평가)

  • Kim, Da-Eun;Yeom, Ji-Woong;Choi, Sung-Joon;Kim, Young-Kyu;Cho, Sung-Min
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.11
    • /
    • pp.1-7
    • /
    • 2020
  • Recently, hydrogen has gained considerable attention as an eco-friendly fuel, which helps in reducing carbon dioxide content. Specifically, there is a growing interest in vehicles powered by a hydrogen fuel cell, which is spotlighted as an environmental-friendly alternative. A hydrogen transport system, fuel cell system, fuel supply system, power management system, and hydrogen storage system are key parts of a hydrogen fuel cell truck. In this study, a hydrogen storage system is built and analyzed. The expansion length of the storage vessel at maximum operating pressure (87.5 MPa) was calculated with ABAQUS, and then the optimized system was designed and built. The leak and bubble tests were performed on the built storage system. The leakage of the system was measured to be under 5 cc/hr. Hence, it can be used as a research test for the safety evaluation of leading systems of hydrogen fuel-powered commercial vehicles.

Wafer Level Hermetic Sealing Characteristics of RF-MEMS Devices using Non-Conductive Epoxy (비전도성 에폭시를 사용한 RF-MEMS 소자의 웨이퍼 레벨 밀봉 실장 특성)

  • 박윤권;이덕중;박흥우;송인상;김정우;송기무;이윤희;김철주;주병권
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.8 no.4
    • /
    • pp.11-15
    • /
    • 2001
  • In this paper, hermetic sealing technology was studied for wafer level packaging of the RF-MEMS devices. With the flip-chip bonding method. this non-conductive B-stage epoxy sealing will be profit to the MEMS device sealing. It will be particularly profit to the RF-MEMS device sealing. B-stage epoxy can be cured by 2-step and hermetic sealing can be obtained. After defining 500 $\mu\textrm{m}$-width seal-lines on the glass cap substrate by screen printing, it was pre-baked at $90^{\circ}C$ for about 30 minutes. It was, then, aligned and bonded with device substrate followed by post-baked at $175^{\circ}C$ for about 30 minutes. By using this 2-step baking characteristic, the width and the height of the seal-line could be maintained during the sealing process. The height of the seal-line was controlled within $\pm$0.6 $\mu\textrm{m}$ in the 4 inches wafer and the bonding strength was measured to about 20MPa by pull test. The leak rate, that is sealing characteristic of the B-stage epoxy, was about $10^{-7}$ cc/sec from the leak test.

  • PDF

Present Status of Soil Contamination Facilities (특정토양오염관리대상시설의 실태에 관한 고찰)

  • Kim, Ki-Ho;Park, Jae-Soo;Kim, Hae-Keum;Choi, Sang-Il
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.45 no.2
    • /
    • pp.287-292
    • /
    • 2012
  • This study was to build the database by collecting the results of legal leak test and self-test conducted by the owners of soil contamination facilities at soil-related specialized agency to grip objective status on soil contamination facilities and evaluate classification results. The results of the study showed that the unsuitable rate of business unit is 53.6%, the business with leak that could cause actual pollution is 25.7%, the unsuitable rate of the voluntary self-test is 57.3%, that of the compulsory inspection is 17.2% depending on the test motivation, that of the direct-test is 58.9%, and that of the indirect-test is 22.5% depending on the test methods. There was a significant difference between the test motivation conducted and the test methods applied. From the results of the unsuitable reasons obtained we could assume that about 20% of the whole target tanks became potential sources with natural defects occurred when such tanks were made, and 2.2% of the whole tankers examined that persisting period was caused by progressing corrosion below the minimum thickness.

A Study of Emergency Response for the Leakage Accident of Hazardous and Noxious Substances in a Port (항만에서의 위험·유해물질(HNS) 누출사고 대응에 관한 연구)

  • Woo, Young Jin;Lee, Chang Jun
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.6
    • /
    • pp.32-38
    • /
    • 2016
  • In general, lots of containers including various dangerous materials are transported to the port located in big cities such as Busan where massive residents live. Thus, it's really important how to make the emergency response for the leak accidents of dangerous materials and evaluate the direct or indirect damages to adjacent areas. In this study, in order to make reasonable emergency plans, CA (Consequence Analysis) is employed after selecting a key hazardous and noxious material, hydrogen fluroide. This material accounts for the third largest portion of cargo volume among all dangerous materials and can cause a huge damage in case of leakages. As a case study, Busan North port is selected as a test port since the portion of dangerous materials is higher than that of other ports in Busan. It is assumed that 1 ton of hydrogen fluoride is spilled at Busan North port. CA is performed to assess the impact of this accident. Throughout CA, the ERPG-2 range of a leak accident can be evaluated and this result can be used for decision making tools for mitigating the impact of a leak accident. To mitigate the damage of this accident, suitable a protective equipment and resident evacuation procedures should be prepared. Finally, this study can provide a systematic approach to make the emergency plan for reducing economical and personal losses.

The Optimal Design and Performance Test of Plunger Pump (플런저 펌프 설계 및 성능시험)

  • 김동수;서현석
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.840-843
    • /
    • 2003
  • The Paper presents theoretical and experimental investigation of plunger type water hydraulic pump (plunger pump). An analysis of Crank shaft for plunger pump is carried out. With this results, the optimal dimensions of plunger pump are determined. And performance test results about slide resistance, hydraulic leak test, efficiency-pressure. and flow-speed and flow-pressure are presented.

  • PDF

Modeling of Hydrodynamic Processes at a Large Leak of Water into Sodium in the Fast Reactor Coolant Circuit

  • Perevoznikov, Sergey;Shvetsov, Yuriy;Kamayev, Aleksey;Pakhomov, Ilia;Borisov, Viacheslav;Pazin, Gennadiy;Mirzeabasov, Oleg;Korzun, Olga
    • Nuclear Engineering and Technology
    • /
    • v.48 no.5
    • /
    • pp.1162-1173
    • /
    • 2016
  • In this paper, we describe a physicomathematical model of the processes that occur in a sodium circuit with a variable flow cross-section in the case of a water leak into sodium. The application area for this technique includes the possibility of analyzing consequences of this leak as applied to sodium-water steam generators in fast neutron reactors. Hydrodynamic processes that occur in sodium circuits in the event of a water leak are described within the framework of a one-dimensional thermally nonequilibrium three-component gas-liquid flow model (sodium-hydrogen-sodium hydroxide). Consideration is given to the results of a mathematical modeling of experiments involving steam injection into the sodium loop of a circulation test facility. That was done by means of the computer code in which the proposed model had been implemented.

Compounding and Test of Gasket Rubber for Fuel Cell Stack Application (연료전지 스택 가스켓용 고무재료의 제조와 평가)

  • Hur, Byung-Ki;Kang, Dong-Gug;Kim, Hye-Young;Seo, Kwan-Ho;Park, Lee-Soon
    • Elastomers and Composites
    • /
    • v.42 no.4
    • /
    • pp.232-237
    • /
    • 2007
  • We examined the properties of compound and made compound of the optimum state using the properties of each material to evaluate suitability of FKM, VMQ, EPDM, NBR with gasket for fuel cell which is in general use with the material of gasket. It could be found from the compound made with setting the optimum state that NBR is worse than FKM in the chemical property of matter for a long term, and VMQ is worse than FKM in the elution of a metal ion, and EPDM is worse than FKM in the permeability of gas. As a result of leak evaluation of gasket for fuel cell with using FKM, it appeared leak in short time when contracting pressure is getting lower and sealing pressure is getting higher. And as a result of the life prediction with using Arrhenius model, we could predict that it is possible to continuously drive for 60,000 hours.

Consideration on Design and Management of Flexible Hose through the Case Study of Chlorine Leak (염소 누출 사고사례연구를 통한 Flexible hose 설계 및 관리 방안 고찰)

  • Park, Suyoul;Yim, Ji-pyo
    • Korean Chemical Engineering Research
    • /
    • v.57 no.3
    • /
    • pp.351-357
    • /
    • 2019
  • This research was performed to propose domestic standard for design and management of flexible hose by analyzing chlorine leak caused by breakage of the hose in Ulsan, 2018. The leak had multiple causes but this paper focuses on analyzing the cause of breakage of flexible hose, the direct cause. According to the analysis, flexible hose that the company of the accident used for chlorine transfer was inappropriate in several aspects including material and wall thickness. And even pressure test had been conducted below operating pressure. Upon investigation on five companies that handle chlorine in Ulsan, four companies were using inappropriate flexible hose for chlorine transfer. Since there is no domestic standard for the design of flexible hose for chlorine transfer at present, it is hard to examine its design adequacy. Design standard of flexible hose used in chlorine transfer that is applicable domestically is proposed based on this research. It will contribute to the reduction in risk of breakage of the hose if the proposed standard could be applied in design and examination of flexible hose.

Crack Opening Displacement Estimation for Engineering Leak-Before-Break Analyses of Pressurized Nuclear Piping (원자력 배관의 공학적 파단전누설 해석을 위한 균열열림변위 계산)

  • Huh Nam-Su;Kim Yun-Jae;Chang Yoon-Suk;Yang Jun-Seok;Choi Jae-Boons
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.10
    • /
    • pp.1612-1620
    • /
    • 2004
  • This study presents methods to estimate elastic-plastic crack opening displacement (COD) fur circumferential through-wall cracked pipes for the Leak-Before-Break (LBB) analysis of pressurized piping. Proposed methods are based not only on the GE/EPRI approach but also on the reference stress approach. For each approach, two different estimation schemes are given, one for the case when full stress-strain data are available and the other fur the case when only yield and ultimate tensile strengths are available. For the GE/EPRI approach a robust way of determining the Ramberg-Osgood (R-O) parameters is proposed, not only fur the case when detailed information on full stress-strain data is available but also for the case when only yield and ultimate tensile strengths are available. The COD estimates according to the GE/EPRI approach, using the R-O parameters determined from the proposed R-O fitting procedures, generally compare well with the published pipe test data. For the reference stress approach, the COD estimates according to the method based on both full stress-strain data and limited tensile properties are in good agreement with pipe test data. In conclusion, experimental validation given in the present study provides sufficient confidence in the use of the proposed method to practical LBB analyses even though when information on material's tensile properties is limited.