• Title/Summary/Keyword: leak frequency

Search Result 83, Processing Time 0.025 seconds

Preferences of Stroke Patients for Kitchen Environment in Residential Space (주거공간의 부엌 환경 특성에 대한 뇌졸중 환자의 선호)

  • Baek, Da-Rae;Jung, Yeon-Jin;Kang, Suk-Gu;Kim, Hee-Jung;Lee, Chun-Yeop
    • The Journal of Korean society of community based occupational therapy
    • /
    • v.4 no.2
    • /
    • pp.1-10
    • /
    • 2014
  • Objective : The purpose of this study was to investigate the preferences of kitchen environment for stroke patients. Methods : The subjects of this study were 97 who have experience in rehabilitation therapy at hospitals in Busan. A questionnaire was distributed and collected from February 24th to March 13th, 2014. Descriptive statistics of frequency Study were used to analyze data. Results : First, the subjects demand for improvement that use a chair for work and install non-slip tiles. Second, they preferred the non-slip mat, boilers in heating equipment, drawer storage, L-shaped safety handle, adjustable sink of the height, automatic cutout of gas leak, faucet of touch-sensitive type, ㄷ-shaped kitchen and the ceiling-type hood in ventilation system. Third, they need kitchen items such as the sink self coming down, scissors for slices and knife to avoid hand injury. Conclusion : This study would contribute to kitchen environment for fall prevention and ease in use.

  • PDF

THE CURRENT STATUS OF BIOMEDICAL ENGINEERING IN THE USA

  • Webster, John G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.05
    • /
    • pp.27-47
    • /
    • 1992
  • Engineers have developed new instruments that aid in diagnosis and therapy Ultrasonic imaging has provided a nondamaging method of imaging internal organs. A complex transducer emits ultrasonic waves at many angles and reconstructs a map of internal anatomy and also velocities of blood in vessels. Fast computed tomography permits reconstruction of the 3-dimensional anatomy and perfusion of the heart at 20-Hz rates. Positron emission tomography uses certain isotopes that produce positrons that react with electrons to simultaneously emit two gamma rays in opposite directions. It locates the region of origin by using a ring of discrete scintillation detectors, each in electronic coincidence with an opposing detector. In magnetic resonance imaging, the patient is placed in a very strong magnetic field. The precessing of the hydrogen atoms is perturbed by an interrogating field to yield two-dimensional images of soft tissue having exceptional clarity. As an alternative to radiology image processing, film archiving, and retrieval, picture archiving and communication systems (PACS) are being implemented. Images from computed radiography, magnetic resonance imaging (MRI), nuclear medicine, and ultrasound are digitized, transmitted, and stored in computers for retrieval at distributed work stations. In electrical impedance tomography, electrodes are placed around the thorax. 50-kHz current is injected between two electrodes and voltages are measured on all other electrodes. A computer processes the data to yield an image of the resistivity of a 2-dimensional slice of the thorax. During fetal monitoring, a corkscrew electrode is screwed into the fetal scalp to measure the fetal electrocardiogram. Correlations with uterine contractions yield information on the status of the fetus during delivery To measure cardiac output by thermodilution, cold saline is injected into the right atrium. A thermistor in the right pulmonary artery yields temperature measurements, from which we can calculate cardiac output. In impedance cardiography, we measure the changes in electrical impedance as the heart ejects blood into the arteries. Motion artifacts are large, so signal averaging is useful during monitoring. An intraarterial blood gas monitoring system permits monitoring in real time. Light is sent down optical fibers inserted into the radial artery, where it is absorbed by dyes, which reemit the light at a different wavelength. The emitted light travels up optical fibers where an external instrument determines O2, CO2, and pH. Therapeutic devices include the electrosurgical unit. A high-frequency electric arc is drawn between the knife and the tissue. The arc cuts and the heat coagulates, thus preventing blood loss. Hyperthermia has demonstrated antitumor effects in patients in whom all conventional modes of therapy have failed. Methods of raising tumor temperature include focused ultrasound, radio-frequency power through needles, or microwaves. When the heart stops pumping, we use the defibrillator to restore normal pumping. A brief, high-current pulse through the heart synchronizes all cardiac fibers to restore normal rhythm. When the cardiac rhythm is too slow, we implant the cardiac pacemaker. An electrode within the heart stimulates the cardiac muscle to contract at the normal rate. When the cardiac valves are narrowed or leak, we implant an artificial valve. Silicone rubber and Teflon are used for biocompatibility. Artificial hearts powered by pneumatic hoses have been implanted in humans. However, the quality of life gradually degrades, and death ensues. When kidney stones develop, lithotripsy is used. A spark creates a pressure wave, which is focused on the stone and fragments it. The pieces pass out normally. When kidneys fail, the blood is cleansed during hemodialysis. Urea passes through a porous membrane to a dialysate bath to lower its concentration in the blood. The blind are able to read by scanning the Optacon with their fingertips. A camera scans letters and converts them to an array of vibrating pins. The deaf are able to hear using a cochlear implant. A microphone detects sound and divides it into frequency bands. 22 electrodes within the cochlea stimulate the acoustic the acoustic nerve to provide sound patterns. For those who have lost muscle function in the limbs, researchers are implanting electrodes to stimulate the muscle. Sensors in the legs and arms feed back signals to a computer that coordinates the stimulators to provide limb motion. For those with high spinal cord injury, a puff and sip switch can control a computer and permit the disabled person operate the computer and communicate with the outside world.

  • PDF

Reoperations on the Aortic Root and Ascending Aorta (대동맥근부 혹은 상행대동맥의 재수술)

  • Baek, Man-Jong;Na, Chan-Young;Kim, Woong-Han;Oh, Sam-Se;Kim, Soo-Cheol;Lim, Cheong;Ryu, Jae-Wook;Kong, Joon-Hyuk;Kim, Wook-Sung;Lee, Young-Tak;Moon, Hyun-Soo;Park, Young-Kwan;Kim, Chong-Whan
    • Journal of Chest Surgery
    • /
    • v.35 no.3
    • /
    • pp.188-198
    • /
    • 2002
  • Background: Reoperations on the aortic root or the ascending aorta are being performed with increasing frequency and remain a challenging problem. This study was performed to analyze the results of reoperations on the ascending aorta and aortic root. Material and Method: Between May 1995 and April 2001, 30 patients had reoperations on the ascending aorta and aortic root and were reviewed retrospectively. The mean interval between the previous repair and the actual reoperation was 56 months(range 3 to 142 months). Seven patients(23.3%) had two or more previous operations. The indications for reoperations were true aneurysm in 7 patients(23.3%), prosthetic valve endocarditis in 6(20%), false aneurysm in 5(16.7%), paravalvular leak associated with Behcet's disease in 4(13.3%), malfunction of prosthetic aortic valve in 4(13.3%), aortic dissection in 3(10%), and annuloaortic ectasia in 1(3.3%). The principal reoperations performed were aortic root replacement in 17 patients(56.7%), replacement of the ascending aorta in 8(26.7%), aortic and mitral valve replacement with reconstruction of fibrous trigone in 2(6.6%), patch aortoplasty in 2(6.6%), and aortic valve replacement after Bentall operation in 1 (3.3%). The cardiopulmonary bypass was started before sternotomy in 7 patients and the hypothermic circulatory arrest was used in 16(53.3%). The mean time of circulatory arrest, total bypass, and aortic crossclamp were 20$\pm$ 12 minutes, 228$\pm$56 minutes, and 143$\pm$62 minutes, respectively Result: There were three early deaths(10%). The postoperative complications were reoperation for bleeding in 7 patients(23.3%), cardiac complications in 5(16.7%), transient acute renal failure in 2(6.6%), transient focal seizure in 2(6.6%), and the others in 5. The mean follow-up was 22.8 $\pm$20.5 months. There were two late deaths(7.4%). The actuarial survival was 92.6$\pm$5.0% at 6 years. One patient required reoperation for complication of reoperation on the ascending aorta and aortic root(3.7%). The 1- and 6-year actuarial freedom from reoperation was 100% and 83.3$\pm$15.2%, respectively. One patient with Behcet's disease are waiting for reoperation due to false aneurysm, which developed after aortic root replacement with homograft. There were no thromboembolisms or anticoagulant related complications. Conclusions: This study suggests that reoperations on the ascending aorta and aortic root can be performed with acceptable early mortality and morbidity, and adequate surgical strategies according to the pathologi conditions are critical to the prevention of the reoperation.