• Title/Summary/Keyword: lead-filter

Search Result 190, Processing Time 0.028 seconds

Organic Precipitate Flotation of Trace Metallic Elements with Ammonium Pyrrolidinedithiocarbamate(Ⅰ). Determination of Bismuth, Cadmium, Cobalt and Lead in Water Samples by Coprecipitation-Flotation with Cu-pyrrolidinedithiocarbamate (Ammonium Pyrrolidinedithiocarbamate에 의한 극미량 금속원소의 유기침전 부선에 관한 연구(제1보) Cu-pyrrolidinedithiocarbamate 공침부선에 의한 물시료중 비스무트, 카드뮴, 코발트 및 납의 정량)

  • Jung, Yong June;Choi, Jong Moon;Choi, Hee Seon;Kim, Young Sang
    • Journal of the Korean Chemical Society
    • /
    • v.40 no.12
    • /
    • pp.724-732
    • /
    • 1996
  • The organic precipitate flotation using Cu(II)-pyrrolidinedithiocarbamate complex as a coprecipitant was studied for the preconcentration and determination of trace Cd, Pb, Bi and Co in several water samples. Experimental conditions such as pH of solution, amounts of Cu(II) and ammonium pyrrolidinedithiocarbamate(APDC), stirring time, the type and amount of surfactant, etc. were optimized for the effective flotation of analytes. After 3.0 mL of 1,000 ${\mu}g/mL$ Cu(II) solution was added to 1.00 L water sample, the pH of the solution was adjusted to 2.5 with HNO3 solution. Trace amounts of analytes were coprecipitated by adding 2.0% APDC solution. And the precipitates were flotated onto the surface of solution with the aid of nitrogen gas and sodium lauryl sulfate. The floats were collected from mother liquor, and filtered through the micropore glass filter by suction. The precipitates were dissolved with 4 mL conc. HNO3, and then diluted to 25.00 mL with deionized water. The analytes were determined by graphite furnace atomic absorption spectrophotometry. This flotation technique was applied to the analysis of some water samples, and the 90 to 120% of recoveries were obtained from the spiked samples, this procedure could be concluded to be simple and applicable for the trace element analysis in various kinds of water.

  • PDF

A Study on UV Filters, Preservatives and Heavy Metals Contained in the Children's and Inorganic Sunscreens Distributed in Korea (국내 유통 어린이 및 무기 자외선차단제에서 자외선 차단성분, 보존제 및 중금속 실태 조사)

  • Kim, Aeran;Lee, You-Jin;Cho, Yun-Sik;Kim, Hyun-Jue;Cho, Sang-Hun;Kim, Yang-Hee;Ro, Jeong-won;Park, Yong-Bae
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.47 no.4
    • /
    • pp.289-296
    • /
    • 2021
  • In this study, 27 inorganic sunscreens and 23 sunscreens for children were collected to investigate the use and incorporation of 17 types of sunscreen agents, 13 types of preservatives, and 5 types of heavy metals. As a result, sunscreen agents were detected in the order of titanium dioxide (41 cases), zinc oxide (29 cases), bis-ethylhexyloxyphenyltriazine (10 cases), ethylhexyl salicylate (8 cases), and ethylhexylmethoxynamate (8 cases), and preservatives were detected in order of phenoxyethanol (6 cases), benzoic acid (1 case), and dihydroacetic acid(1 case). All of the identified sunscreen agents were suitable for labeling, but phenoxyethanol, a preservative component other than labeling, was detected at a concentration of 0.1%. Heavy metals such as lead, cadmium, arsenic, antimony, and nickel were not detected or were detected at various concentrations of less than 3.6 ㎍/g. All the detected UV filters, preservatives, and heavy metals were less than the allowed maximum amount stipulated by the Regulations on Cosmetic Safety Standards in Korea.

A Study on the Comparison of Detected Vein Images by NIR LED Quantity of Vein Detector (정맥검출기의 NIR LED 수량에 따른 검출된 정맥 이미지 비교에 관한 연구)

  • Jae-Hyun, Jo;Jin-Hyoung, Jeong;Seung-Hun, Kim;Sang-Sik, Lee
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.15 no.6
    • /
    • pp.485-491
    • /
    • 2022
  • Intravenous injection is the most frequent invasive treatment for inpatients and is widely used for parenteral nutrition administration and blood products, and more than 1 billion procedures are used for peripheral catheter insertion, blood collection, and other IV therapy per year. Intravenous injection is one of the difficult procedures to be performed only by trained nurses with intravenous injection training, and failure can lead to thrombosis and hematoma or nerve damage to the vein. Accordingly, studies on auxiliary equipment capable of visualizing the vein structure of the back of the hand or arm are being published to reduce errors during intravenous injection. This study is a study on the performance difference according to the number of LEDs irradiating the 850nm wavelength band on a vein detector that visualizes the vein during intravenous injection. Four LED PCBs were produced by attaching NIR filters to CCD and CMOS camera lenses irradiated on the skin to acquire images, sharpen the acquired images using image processing algorithms, and project the sharpened images onto the skin. After that, each PCB was attached to the front end of the vein detector to detect the vein image and create a performance comparison questionnaire based on the vein image obtained for performance evaluation. The survey was conducted on 20 nurses working at K Hospital.

Concentration of heavy metals in shellfishes and health risk assessment from Korean coastal areas

  • Ka Jeong Lee;Eun Hye Kang;Minchul Yoon;Mi Ra Jo;Hong Sik Yu;Kwang Tae Son
    • Fisheries and Aquatic Sciences
    • /
    • v.25 no.12
    • /
    • pp.626-636
    • /
    • 2022
  • Shellfish are exoskeleton-bearing aquatic invertebrates that consume various organic and inorganic substances floating in seawater through filter feeding. Heavy metals are known as absorbed and accumulated in seawater. Some of the toxic heavy metals are highly accumulated in seawater, and exposure to them can cause a variety of risks to the human body. Since Koreans like to eat seafood, they are more likely to be exposed to contaminated seafood with heavy metals. In this study, nine types of heavy metals were analyzed on ten different shellfish species in the coastal area of South Korea. The risk assessment was also done on shellfish in which heavy metals were detected. Zinc (Zn) and copper (Cu) were identified at an average of 56.7 mg/kg (6.70 to 466 mg/kg) and 13.2 mg/kg (0.064 to 143 mg/kg), respectively. Lead (Pb) average of 0.208 mg/kg (0.000750 to 1.02 mg/kg), cadmium (Cd) average of 0.454 mg/kg (0.0388 to 1.56 mg/kg) and mercury (Hg) average of 0.0266 mg/kg (0.00548 to 0.174 mg/kg) were identified. Additionally, arsenic (As), chromium (Cr), nickel (Ni), and silver (Ag) were also identified as average concentrations of 4.02 (0.460 to 15.0 mg/kg), 0.167 (< limit of quantification [LOQ] to 0.820 mg/kg), 0.281 (< LOQ to 1.46 mg/kg), and 0.158 mg/kg (< LOQ to 1.15 mg/kg). The result indicates that the monitoring results of heavy metals in most shellfish satisfied the Korean standard. However, Pb and Cd have exceeded some foreign standards, such as the United States and the EU. The permissible human exposure calculated using the heavy metal intake and detection amount was lower than the Joint FAO/WHO Expert Committee on Food Additives human safety standard, and the risk of heavy metals from shellfish consumption was at an acceptable level.

Teaching Orientations and Classroom Practices of Science Teachers Participating in Workshops for Constructivistic Science Teaching (구성주의적 수업을 위한 워크숍에 참여한 중등 과학 교사의 교수 지향과 수업 실행)

  • Jeong, Deuk-Sil;Lee, Sun-Kyung;Oh, Phil-Seok;Maeng, Seung-Ho;Chung, Ae-Ran;Kim, Chan-Jong
    • Journal of The Korean Association For Science Education
    • /
    • v.27 no.5
    • /
    • pp.432-446
    • /
    • 2007
  • The purpose of the study is to explore the science teaching orientations of secondary science teachers, and how they influence the planning and execution of reform-based lessons. Professional development workshop for constructivist teaching consisted of three different phases; five lectures, small group discussion, and preparing lesson plans. Four teachers who participated also executed their lesson plans in their own classroom. All workshops were videotape recorded. Classroom observations and interviews were conducted and recorded. Instructional materials were also collected for each science class. All data recorded were transcribed and analyzed. Based on the data collected from multiple sources, we identified each teacher's teaching orientations, and through this lens, we also tried to understand their classroom practices. We expected teacher-participants to implement constructivist science teaching. However, the differences among teachers in the course of actual planning and implementing activities for constructivist science was wider than we expected and even some teachers were unsuccessful. Teaching orientations can act as a filter for teachers when they decide whether to accept and apply new knowledge about teaching and learning to actual lessons or not. Even if a teacher plans a guided-inquiry lesson, her/his didactic teaching orientation could be revealed in actual classroom, and lead her/his class to other direction which is quite different from her/his original intention. Although the teachers participated in the same workshops in our study, they planned and executed differently and their own teaching orientations contribute substantially to their practice. Understanding the role of science teaching orientations could be an important step in addressing issues of diverse difficulties in supporting reform efforts in science.

Oxidized LDL is a Chemoattractant for the Eosinophils and Neutrophils (산화 저비중 리포 단백이 호산구와 호중구에 대한 화학주성)

  • Hwang, Young-Sil;Lee, Jong-Deog;Busse, William B.
    • Tuberculosis and Respiratory Diseases
    • /
    • v.51 no.3
    • /
    • pp.211-223
    • /
    • 2001
  • Background : Rhinovirus infection of the airways results in increased permeability of the airway vascular endothelium with the influx of plasma proteins, including lipids such as LDL. In vitro studies on the effect of oxLDL on leukocytes has shown many pro inflammatory effects on multiple leukocytes. We hypothesized that oxLDL is one mechanism for recruiting granulocytes to the airways during a RV infection. Therefore, chemotaxis and transendothelial migration, in response to nLDL, was determined for these granulocytes. Methods : nLDL was oxidized with 5mM Cu2S04 for 20-24 hours. 3-5 105 cells were loaded into the Transwell filter while the chemotatic agonists were placed in the lower well for chemotaxis. Confluent monolayers on HPMEC were grown on Transwell filters for transendothelial migration. The filters were washed and eosinophils and neutrophils loaded on to the filter with the chemotatic agonist was were placed in the lower well. The wells were incubated for 3 hours. The number of migrating cells was counted on a hemocytometer. Results : OxLDL, but not nLDL, is chemotatic for eosinophils and neutrophils. The level of granulocytes chemotaxis was dependent on both the concentration of LDL and its degree of oxidation. OxLDL stimulates eosinophil and neutrophils migration across HPMEC monolayers (+/-IL-$1{\beta}$ preactivation) in a dose dependent manner. Conclusion : Increased vascular permeability during a RV infection may lead to the influx and oxidation of LDL. The resulting oxLDL. is one possible mechanism for the recruitment of neutrophils and eosinophils to the airway interstitial matrix. Once in the airways, granulocytes can further interact with oxLDL to promote airway inflammation.

  • PDF

Evaluation of Dose Reduction of Cardiac Exposure Using Deep-inspiration Breath Hold Technique in Left-sided Breast Radiotherapy (좌측 유방암 방사선 치료에서 깊은 들숨 호흡법을 이용한 심장 선량 감소 평가)

  • Jung, Joo-Young;Kim, Min-Joo;Jung, Jae-Hong;Lee, Seu-Ran;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.24 no.4
    • /
    • pp.278-283
    • /
    • 2013
  • Breast cancer is the leading cause of cancer death in women worldwide and the number of women breast cancer patient was increased continuously. Most of breast cancer patient has suffered from unnecessary radiation exposure to heart, lung. Low radiation dose to the heart could lead to the worsening of preexisting cardiovascular lesions caused by radiation induced pneumonitis. Also, several statistical reports demonstrated that left-sided breast cancer patient showed higher mortality than right-sided breast cancer patient because of heart disease. In radiation therapy, Deep Inspiration Breath Hold (DIBH) technique which the patient takes a deep inspiration and holds during treatment and could move the heart away from the chest wall and lung, has showed to lead to reduction in cardiac volume and to minimize the unnecessary radiation exposure to heart during treatment. In this study, we investigated the displacement of heart using DIBH CT data compared to free-breathing (FB) CT data and radiation exposure to heart. Treatment planning was performed on the computed tomography (CT) datasets of 10 patients who had received lumpectomy treatments. Heart, lung and both breasts were outlined. The prescribed dose was 50 Gy divided into 28 fractions. The dose distributions in all the plans were required to fulfill the International Commission on Radiation Units and Measurement specifications that include 100% coverage of the CTV with ${\geq}95%$ of the prescribed dose and that the volume inside the CTV receiving >107% of the prescribed dose should be minimized. Scar boost irradiation was not performed in this study. Displacement of heart was measured by calculating the distance between center of heart and left breast. For the evaluation of radiation dose to heart, minimum, maximum and mean dose to heart were calculated. The present study demonstrates that cardiac dose during left-sided breast radiotherapy can be reduced by applying DIBH breathing control technique.

Effect of the Configuration of Contact Type Textile Electrode on the Performance of Heart Activity Signal Acquisition for Smart Healthcare (스마트 헬스케어를 위한 심장활동 신호 검출용 접촉식 직물전극의 구조가 센싱 성능에 미치는 영향)

  • Cho, Hyun-Seung;Koo, Hye-Ran;Yang, Jin-Hee;Lee, Kang-Hwi;Kim, Sang-Min;Lee, Jeong-Hwan;Kwak, Hwy-Kuen;Ko, Yun-Su;Oh, Yun-Jung;Park, Su-Youn;Kim, Sin-Hye;Lee, Joo-Hyeon
    • Science of Emotion and Sensibility
    • /
    • v.21 no.4
    • /
    • pp.63-76
    • /
    • 2018
  • The purpose of this study was to investigate the effect of contact type textile electrode structure on heart activity signal acquisition for smart healthcare. In this study, we devised six contact type textile electrodes whose electrode size and configuration were manipulated for measuring heart activity signals using computerized embroidery. We detected heart activity signals using a modified lead II and by attaching each textile electrode to the chest band in four healthy male subjects in a standing static posture. We measured the signals four times repeatedly for all types of electrodes. The heart activity signals were sampled at 1 kHz using a BIOPAC ECG100, and the detected original signals were filtered through a band-pass filter. To compare the performance of heart activity signal acquisition among the different structures of the textile electrodes, we conducted a qualitative analysis using signal waveform and size as parameters. In addition, we performed a quantitative analysis by calculating signal power ratio (SPR) of the heart activity signals obtained through each electrode. We analyzed differences in the performance of heart activity signal acquisition of the six electrodes by performing difference and post-hoc tests using nonparametric statistic methods on the calculated SPR. The results showed a significant difference both in terms of qualitative and quantitative aspects of heart activity signals among the tested contact type textile electrodes. Regarding the configurations of the contact type textile electrodes, the three-dimensionally inflated electrode (3DIE) was found to obtain better quality signals than the flat electrode. However, regarding the electrode size, no significant difference was found in performance of heart signal acquisition for the three electrode sizes. These results suggest that the configuration method (flat/3DIE), which is one of the two requirements of a contact type textile electrode structure for heart activity signal acquisition, has a critical effect on the performance of heart activity signal acquisition for wearable healthcare. Based on the results of this study, we plan to develop a smart clothing technology that can monitor high-quality heart activity without time and space constraints by implementing a clothing platform integrated with the textile electrode and developing a performance improvement plan.

Imaging Characteristics of Computed Radiography Systems (CR 시스템의 종류와 I.P 크기에 따른 정량적 영상특성평가)

  • Jung, Ji-Young;Park, Hye-Suk;Cho, Hyo-Min;Lee, Chang-Lae;Nam, So-Ra;Lee, Young-Jin;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.19 no.1
    • /
    • pp.63-72
    • /
    • 2008
  • With recent advancement of the medical imaging systems and picture archiving and communication system (PACS), installation of digital radiography has been accelerated over past few years. Moreover, Computed Radiography (CR) which was well established for the foundation of digital x-ray imaging systems at low cost was widely used for clinical applications. This study analyzes imaging characteristics for two systems with different pixel sizes through the Modulation Transfer Function (MTF), Noise Power Spectrum (NPS) and Detective Quantum Efficiency (DQE). In addition, influence of radiation dose to the imaging characteristics was also measured by quantitative assessment. A standard beam quality RQA5 based on an international electro-technical commission (IEC) standard was used to perform the x-ray imaging studies. For the results, the spatial resolution based on MTF at 10% for Agfa CR system with I.P size of $8{\times}10$ inches and $14{\times}17$ inches was measured as 3.9 cycles/mm and 2.8 cycles/mm, respectively. The spatial resolution based on MTF at 10% for Fuji CR system with I.P size of $8{\times}10$ inches and $14{\times}17$ inches was measured as 3.4 cycles/mm and 3.2 cycles/mm, respectively. There was difference in the spatial resolution for $14{\times}17$ inches, although radiation dose does not effect to the MTF. The NPS of the Agfa CR system shows similar results for different pixel size between $100{\mu}m$ for $8{\times}10$ inch I.P and $150{\mu}m$ for $14{\times}17$ inch I.P. For both systems, the results show better NPS for increased radiation dose due to increasing number of photons. DQE of the Agfa CR system for $8{\times}10$ inch I.P and $14{\times}17$ inch I.P resulted in 11% and 8.8% at 1.5 cycles/mm, respectively. Both systems show that the higher level of radiation dose would lead to the worse DQE efficiency. Measuring DQE for multiple factors of imaging characteristics plays very important role in determining efficiency of equipment and reducing radiation dose for the patients. In conclusion, the results of this study could be used as a baseline to optimize imaging systems and their imaging characteristics by measuring MTF, NPS, and DQE for different level of radiation dose.

  • PDF

The Effective Approach for Non-Point Source Management (효과적인 비점오염원관리를 위한 접근 방향)

  • Park, Jae Hong;Ryu, Jichul;Shin, Dong Seok;Lee, Jae Kwan
    • Journal of Wetlands Research
    • /
    • v.21 no.2
    • /
    • pp.140-146
    • /
    • 2019
  • In order to manage non-point sources, the paradigm of the system should be changed so that the management of non-point sources will be systematized from the beginning of the use and development of the land. It is necessary to change the method of national subsidy support and poeration plan for the non-point source management area. In order to increase the effectiveness of the non-point source reduction project, it is necessary to provide a minimum support ratio and to provide additional support according to the performance of the local government. A new system should be established to evaluate the performance of non-point source reduction projects and to monitor the operational effectiveness. It is necessary to establish the related rules that can lead the local government to take responsible administration so that the local governments faithfully carry out the non-point source reduction project and achieve the planned achievement and become the sustainable maintenance. Alternative solutions are needed, such as problems with the use of $100{\mu}m$ filter in automatic sampling and analysis, timely acquisition of water sampling and analysis during rainfall, and effective management of non-point sources network operation management. As an alternative, it is necessary to consider improving the performance of sampling and analysis equipment, and operate the base station. In addition, countermeasures are needed if the amount of pollutant reduction according to the non-point source reduction facility promoted by the national subsidy is required to be used as the development load of the TMDLs. As an alternative, it is possible to consider supporting incentive type of part of the maintenance cost of the non-point source reduction facility depending on the amount of pollutants reduction.