• 제목/요약/키워드: lead target

검색결과 515건 처리시간 0.025초

나사 리드 측정시스템 개발 (Development of The Screw Lead Measurement System)

  • 최종근;최현철;김형선
    • 한국공작기계학회논문집
    • /
    • 제16권5호
    • /
    • pp.7-13
    • /
    • 2007
  • This study proposes a new screw measurement system that is capable of measuring the pitch or lead of a screw, which is one of the most important parameters representing the screw quality. There are various conventional methods for screw measurement including some mechanical and optical ones, but they can not be applied to measure the lead except the profiles or sizes. The newly suggested method is able to measure the pitch or lead directly. This is executed by scanning the thread with a digital probe while the target screw rotates. The devised measurement system is a integrated computer system which is composed of a stepping motor, a digital linear gauge and a chuck device for holding the measured screw. In order to operate the system effectively and conveniently, a computer program having graphical user interface facility is developed. Some experiments were done to prove the effectiveness of the system.

강체 충격자가 납 표적에 충돌할 때의 침투특성 연구 (A Study on the Penetration Characteristics of the Rigid Impactor into the Lead Target)

  • 이영신;강근희;최병두;박관진;정수경;오종수
    • 전산구조공학
    • /
    • 제11권4호
    • /
    • pp.147-154
    • /
    • 1998
  • 강체 충격자가 납 표적에 33m/s ∼ 141m/s의 속도로 충돌할 때의 침투특성을 연구하기 위하여 Jognson 이론식을 이용한 이론해석과 AUTODYN 코드를 이용한 수치해석 및 실험장치를 이용한 실험측정을 실시하고 그 결과들을 비교 분석하였다. 실험장치로는 가스압력식 발사장치를 설계 제작하였으며, 실험용 충격자로는 충돌부위 형상이 반구형인 반구형 충격자와 원추형인 원추형 충격자 2종류를 사용하였다. 또한, 납재료에 대한 동적 유동응력을 얻기 위하여 홉킨스 압력봉실험을 수행하였다. 침투특성에 관한 연구결과, 이론적 해석결과는 저속 충돌범위(반구형 충격자 : 53m/s, 원추형 충격자 ; 73m/s)에서 실험결과치와 93%이상 잘 일치하였으며, 수치해석결과는 전체적인 충돌속도 범위에서 반구형 충격자인 경우 73%이상, 원추형 충격자인 경우 86%이상 일치하였다.

  • PDF

Thermal Characteristics of Rotating Anode X-ray Tube with Emissivity in Aging Process for Digital Radiography

  • Lee, Seok Moon
    • Applied Science and Convergence Technology
    • /
    • 제24권5호
    • /
    • pp.125-131
    • /
    • 2015
  • We investigated the thermal characteristics of rotating anode X-ray tube to develop it for digital radiography by using computer simulation. The target which is the area of the anode struck by electrons is the most important component to get a long life of X-ray tube. So we analyze the thermal characteristics of the target and rotor assembly according to their emissivity by using ANSYS transient thermal simulation and then compare with the measured data of the target temperature operating in aging process of X-ray tube. Especially, keeping the lead coated layer as the role of metal lubricant on ball bearing enables to prevent the noise in rotating anode. The simulation result showed that its temperature was under the melting point of the lead in X-ray tube for digital radiography with 1.2 mm large focal spot 0.6 mm small focal spot and 150 kV tube voltage. We also investigated the relationship between the diameter of the anode shaft and the temperature of the anode and rotor assembly. It has been confirmed that the smaller anode shaft could be good for the rotor thermal characteristics.

PROPOSE NEW MIXTURE TARGET FOR LOW-TEMPERATURE AND HIGH- RATE DEPOSITION OF PZT THIN FILMS BY REACTIVE SPUTTERING

  • Hata, Tomonobu;Zhang, WeiXiao;Sasaki, Kimihiro
    • 한국표면공학회지
    • /
    • 제29권5호
    • /
    • pp.330-337
    • /
    • 1996
  • A rf reactive sputter deposition technique was adopted to deposit ferroelectric lead zirconate titanate (PZT) thin films with high rate from a ZrTi alloy target combined with PbO pellets. Deposition characterisitics including the effects of PbO are ratio were discussed. A new deposition mode called the quasi-metallic mode was observed. Perovskite PZT films were prepared at a growth temperature as low as$ 450^{\circ}C$. However, because the target structure is unstable, weproposed a mixture target consisted of Zr, Ti and PbO. Fundamental experiments were investigated using the powder target. Perovskite PZT film could be obtained at $450^{\circ}C$ with better electrical properties also.

  • PDF

Design and Optimization for the Windowless Target of the China Nuclear Waste Transmutation Reactor

  • Cheng, Desheng;Wang, Weihua;Yang, Shijun;Deng, Haifei;Wang, Rongfei;Wang, Binjun
    • Nuclear Engineering and Technology
    • /
    • 제48권2호
    • /
    • pp.360-367
    • /
    • 2016
  • A windowless spallation target can provide a neutron source and maintain neutron chain reaction for a subcritical reactor, and is a key component of China's nuclear waste transmutation of coupling accelerator and subcritical reactor. The main issue of the windowless target design is to form a stable and controllable free surface that can ensure that energy spectrum distribution is acquired for the neutron physical design when the high energy proton beam beats the lead-bismuth eutectic in the spallation target area. In this study, morphology and flow characteristics of the free surface of the windowless target were analyzed through the volume of fluid model using computational fluid dynamics simulation, and the results show that the outlet cross section size of the target is the key to form a stable and controllable free surface, as well as the outlet with an arc transition. The optimization parameter of the target design, in which the radius of outlet cross section is $60{\pm}1mm$, is verified to form a stable and controllable free surface and to reduce the formation of air bubbles. This work can function as a reference for carrying out engineering design of windowless target and for verification experiments.

In Vivo Effects of Lead on Erythrocytes Following Chronic Exposure through Drinking Water

  • Lee, Moo-Yeol;Shin, Jung-Hun;Han, Hee-Shim;Chung, Jin-Ho
    • Archives of Pharmacal Research
    • /
    • 제29권12호
    • /
    • pp.1158-1163
    • /
    • 2006
  • More than 95% of lead, a environmental heavy metal, entering into blood accumulates in erythrocytes suggesting erythrocytes as an important target of lead toxicity. Recent studies reported that erythrocytes could contribute to blood coagulation via phosphatidylserine (PS) exposure in erythrocytes. However, in vivo effects of chronic lead exposure especially by drink-ing water on procoagulant activity of erythrocytes have not been studied yet. In the present study, we investigated the effects of chronic exposure of lead by drinking water on erythrocytes in rats. Groups of 40 male rats were provided with drinking water containing various concentrations of lead for 4 weeks and complete blood cell count, procoagulant activities of erythrocytes and platelets were evaluated with basic inspections on body weight and food/water consumption. The administration of lead containing drinking water increased the blood lead level (BLL) in a dose-dependent manner up to $22.39{\pm}2.26\;{\mu}g/dL$. Water consumption was significantly decreased while food consumption or body weight gain was not affected. In contrast to the previous findings with acute lead exposure, chronic lead exposure failed to increase PS exposure in erythrocytes with statistical significance although some trends of enhancement were observed. It implies that a certain adaptation might have happened in body during repeated exposure to lead, resulting in attenuation of PS exposure. With this study, we believe that a valuable information was provided for the study on the toxicological significance and the risk assessment of lead contaminated drinking water.

Laser와 PZT - Target간의 반응과 그에 따른 Plume 형성 및 입자 방출에 관한 연구 (Interaction of Laser Beam with PZT - Target and Observation of Laser - Induced Plume and Particle Ejection)

  • 이병우
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제20권5호
    • /
    • pp.93-102
    • /
    • 1996
  • Laser-induced plume and laser-target interaction during pulsed laser deposition are demonstrated for a lead zirconate titanate (PZT). A KrF excimer laser (wavelength 248nm) was used and the laser was pulsed at 20Hz, with nominal pulse width of 20ns. The laser fluence was~$16J/cm^2,$ with 100mJ per pulse. The laser-induced plasma plume for nanosecond laser irradiation on PZT target has been investigated by optical emission spectra using an optical multichannel analyzer(OMA) and by direct observation of the plume using an ICCD high speed photography. OMA analysis showed two distinct ionic species with different expansion velocities of fast or slow according to their ionization states. The ion velocity of the front surface of the developing plume was about $10^7$cm/sec and corresponding kinetic energy was about 100eV. ICCD photograph showed another kind of even slower moving particles ejected from the target. These particles considered expelled molten parts of the target. SEM morphologies of the laser irradiated targets showed drastic melting and material removal by the laser pulse, and also showed the evidence of the molten particle ejection. The physics of the plasma(plume) formation and particle ejection has been discussed.

  • PDF

기니픽에서 갑상선, 간 및 신기능에 미치는 납과 selenium의 상호관계 (Interaction of lead and selenium on several aspects of thyroid, liver, and kidney function in guinea pigs)

  • 김진상;강형섭;강창원
    • 대한수의학회지
    • /
    • 제36권3호
    • /
    • pp.699-707
    • /
    • 1996
  • This study was designed to examine the involvement of lead in function of target organ, and the protective effect of selenium in lead-treated guinea pigs for 8 weeks. The effects of exposure to 0.5% lead acetate(lead) and/or 4ppm sodium selenite(selenium) in feed on serveral aspects were evaluated by measuring thyroid stimulating hormone(TSH), triiodothyronine($T_3$), thyroxine($T_4$), serum biochemical activities, organ weights, and serum and organ lead concentrations in growing animals. The many indicators of endocrine function(TSH, $T_3$, and $T_4$ in serum), enzyme and biochemical activities(${\alpha}$-glutamyltranspeptidase, alkaline phosphatase, lactate dehydrogenase, triglyceride, creatinine, $Ca^{2+}$ in serum), and organ weights(kidney, spleen and testis) were correlated with lead exposure or showed significantly different mean values between the exposed and controls. These changes on some aspects were reversed by combination-fed of selenium, but did not statistically significant. The organ(kidney, liver, spleen, testis and brain) and serum lead concentrations of lead-fed group were clearly higher than that of controls. Selenium supplementation resulted in a significant protection against lead accumulation in liver and testis. These results suggest that lead can cause a toxic effect on several organ and that selenium seems to has a protective effect on specific reaction by lead-induced organic function toxicity.

  • PDF