• Title/Summary/Keyword: lead loss

Search Result 845, Processing Time 0.029 seconds

Copper Loss and Torque Ripple Minimization in Switched Reluctance Motors Considering Nonlinear and Magnetic Saturation Effects

  • Dowlatshahi, Milad;Saghaiannejad, Sayed Morteza;Ahn, Jin-Woo;Moallem, Mehdi
    • Journal of Power Electronics
    • /
    • v.14 no.2
    • /
    • pp.351-361
    • /
    • 2014
  • The discrete torque generation mechanism and inherently nonlinear magnetic characterization of switched reluctance motors lead to unacceptable torque ripples and limit the application of these motors. In this study, a phase current profiling technique and torque sharing function are proposed in consideration of magnetic saturation effects and by minimizing power loss in the commutation area between the adjacent phases. Constant torque trajectories are considered in incoming and outgoing phase current planes based on nonlinear T-i-theta curves obtained from experimental measurements. Optimum points on constant torque trajectories are selected by improving drive efficiency and minimizing copper loss in each rotor position. A novel analytic invertible function is introduced to express phase torque based on rotor position and its corresponding phase current. The optimization problem is solved by the proposed torque function, and optimum torque sharing functions are derived. A modification method is also introduced to enhance the torque ripple-free region based on simple logic rules. Compared with conventional torque sharing functions, the resultant reference current from the proposed method has less peak and effective values and exhibits lower copper loss. Experimental and simulation results from a four-phase 4 KW 8/6 SRM validate the effectiveness of the proposed method.

Influence of Tape's Critical Currents and Current Distributions on AC Loss Measurement in a Multi-tape Conductor (임계전류 및 전류분포가 다중테이프 초전도도체의 교류손실 측정에 미치는 영향)

  • Ryu Kyung Woo;Ma Y. H.;Choi Byoung Ju;Hwang S. D.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.7 no.1
    • /
    • pp.47-50
    • /
    • 2005
  • The AC loss is an important issue in the design of the high temperature superconductor (HTS) power cables, which consist of a number of lli 2223 tapes wound on a former. In the cables, the tapes have different critical currents intrinsically. And they are electrically connected to each other and current leads. These make loss measurements considerably complex, especially for short samples of laboratory size. In this work we have prepared a multi-tape conductor composed of Bi-2223 tapes. The at losses of the conductor have experimentally investigated. The loss tests indicate that the effect of tapes critical currents on AC loss measurement in the multi tape conductor is negligible only if currents in the tapes flow uniformly Moreover, the measured tosses of the conductor are in good agreement with the sum of the transport losses in the tapes. However, in the case of non-uniform current distributions, the measured AC losses considerably depend on the current distribution parameter of the positioning of a voltage lead. Thus special cautions should be needed for the measurement of the true AC losses in the short power cable samples.

The Development of Public Campaign Message for Prevention of Hearing Loss (청력손실 예방을 위한 공익캠페인 메시지 개발을 위한 연구 : 20대 대학생을 대상으로)

  • Sun, Hye-Jin
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.9
    • /
    • pp.329-337
    • /
    • 2019
  • Prevention is very important in terms of the fact that the percentage of people in their 10s and 20s experience noise-prone hearing is so serious that it can lead to serious hearing later on. This study examines the effect of the hearing loss prevention public advertisement message on the hearing loss prevention intent of the acceptor according to the type of framing(positive/negative) and self-efficacy information provision (provide information/do not provide information). The perceived risk and future time orientation as individual characteristics of individual participants were set as variables that could influence the message effect. In this paper, we propose a message expression method and effective message delivery method in the aspect of message strategy and effect of execution when promoting understanding and interest in hearing loss prevention.

Fault-Management Scheme for Recovery Time and Resource Efficiency in OBS Networks (OBS 망에서 복구 시간과 자원의 효율성을 고려한 장애 복구 기법)

  • 이해정;정태근;소원호;김영천
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.9B
    • /
    • pp.793-805
    • /
    • 2003
  • In OBS (Optical Burst Switching) networks which decouple the burst from its header, the fault of a fiber link can lead to the failure of all the light-path that traverses the fiber. Because each light-path is expected to operate at a rate of a few Gbps by using WDM (Wavelength Division Multiplexing) technology, any failure may lead to large data loss. Therefore, an efficient recovery scheme must be provided. In this paper, we analyze network utilization and BCP (Burst Control Packet) loss rate according to each link failure by applying the conventional restoration schemes in OBS networks. And through these simulation results, an ASPR scheme is proposed improve the fault management scheme in terms of recovery time and throughput. Finally, We compare the performance of our proposed scheme with that of the conventional one with respect to burst loss rate, resource utilization and throughput by OPNET simulations.

Clinicopathological and Histopathological Findings of Experimental Lead Poisoning in Dogs (실험적 납 중독견의 임상병리학적 및 조직병리학적 소견)

  • 장종식;이현범
    • Journal of Veterinary Clinics
    • /
    • v.14 no.1
    • /
    • pp.78-87
    • /
    • 1997
  • The study of present study was to determine the valuable laboratory tests for the differential diagnosis of lead poisoning in dogs. Sixteen mongrel dogs were divided into 2 experimental groups (A and B) and a control group (C). The A and B groups were administered orally 2 mg and 20 mg of lead per kilogram of body weight for 49 days, respectively. In addition to clinical observation, blood, urine and hair samples were collected on appointed day and examined for hematological changes, lead content of serum, whole blood and hair, and urinary $\delta$-aminolevulinic acid concentrations. All dogs were necropside on 49th day and examined for the lead content and histological changes of organs. The results obtained were summarized as follows: The group B showed digestive and nervous signs, and weight loss. The group A showed no significant hematological changes except polychromatophilla on the 7th day. But group B showed polychromatophilia as well as mild anemia and nucleated erythrocyte on the 7th and 35th day. Basophlic stippling erythrocytes were observed in some of the group B on the 14th day. The lead content of whole blood was increased significantly in both A and B groups on the 21the day. The urinary $\delta$-aminolevulinic acid content was increased in both A and B groups on the 7th day. The hair lead content of A and B groups was increased significantly on the 49th and 21th day, respectively. The lead contents of organs including liver, kidney, spleen, muscle and bone were increased significantly in group B. Histopathologic changes were characterized by hemorrhages, necrosis and intranuclear inclusion body in the epithelial cells of convoluted tubles of kidney, cloudy swelling and degeneration and/or necrosis of liver, enlargement of Virchow-Robin space, and swelling of endothelial cells and hyperplasia of the pericytes of brain. From these results it may be concluded that examination of nucleated erythrocyte/polychromatophilia, urinary $\delta$ -aminolevulinic acid, and whole blood and hair lead contents is a reliable clinico-pathological diagnostic methods, and that examination of the Virchow-Robin space, endothelial cells and pericytes of brain as well as intranuclear inclusion body in the epithelial cells of convoluted tubles of kidney is valualble postmortem diagnostic methods for lead poisoning in dogs.

  • PDF

Reflection-Type 5-bit Digital Phase Shifter with Constant Insertion Loss (균일 삽입 손실 특성을 갖는 반사형의 5-비트 디지털 위상 변위기)

  • 고경석;최익권
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.6
    • /
    • pp.582-589
    • /
    • 2002
  • This paper presents 12.2 GHz ~ 12.7 GHz frequency band reflection type 5-bit digital phase shifter with constant insertion loss property that was fabricated with relatively low cost's InGaAs HEMT for amplifier. The unavoidable large insertion loss difference between on and off states of HEMT, when it is designed by conventional design theory based on ideal switching device, is removed by transforming the HEMT impedances at on and off states to other proper values connecting a certain length transmission line to HEMT and then applying the conventional design theory. The fabricated 5-bit digital phase shifter shows very good insertion loss properties of less than 1.5 dB insertion loss difference and -4.5 dB ~ -6 dB insertion loss in 35 phase steps at 12.2 GHz ~ 12.7 GHz. These results verify the design method presented in this paper, which is useful to design phase shifter of constant insertion loss with non-ideal switching device.

A Study on Protective Coordination Setting of Positive Offset Mho Loss of Field Relay (Positive Offset Mho 계자 상실 계전기 보호 협조 정정에 관한 연구)

  • Kim, Kwnag-Hyun;Park, Ji-Kyung;Kim, Jun-Hyeok;Kim, Doo-Ung;Kang, Sung-Bum;Kim, Chul-Hwan;Lyu, Young-Sik;Yang, Jeong-Jae;Ko, Yun-Tae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.8
    • /
    • pp.1326-1333
    • /
    • 2016
  • It is important to clear the fault and prevent resulting in damage to power system. Although the frequency of generator internal fault is relatively low, it can lead to incalculable damage to power system as well as generator. Especially, loss of field on generator can cause the generator to lose synchronism for a short time if it is not removed promptly. Therefore, it is needed to conduct research on loss of field relay for detecting or clearing the loss of field. However, the setting of the relay may vary in generator operator or engineer, and the relay is not coordinated well with other elements associated with loss of field. In this paper, we address specifically the coordination of positive offset mho loss of field relay which is one of the protection schemes for loss of field. Computer simulations are performed by using ElectroMagnetic Transients Program-Restructured Version (EMTP-RV) based on actual data.

Value Evaluation depending on Different Perception of Promotion Tools (차별적 판촉인식에 따른 판촉가치평가)

  • Kim, Ju-Young
    • Journal of Distribution Research
    • /
    • v.11 no.1
    • /
    • pp.21-40
    • /
    • 2006
  • The purpose of this paper is to investigate how evaluation of sales promotion is affected by consumer's perception on sale promotion tools(SP). Perception on SP is supposed to be classified into reduced loss and separate gain according to characteristics of SP, that are benefit realization period(immediate vs. remote), easy to calculate cash value(easy vs. difficult), and purchase occasion(concurrent vs. different). Hypothesis testing using ANOVA and structural equation model about data that is collected from college students based on experimental design, reveals that immediate realization and easy calculation make SP tool perceived as reduced loss. And perception as reduced loss is more effective to be evaluated as high value and lead to purchase intention.

  • PDF

A Retrospective study on upper single tooth implants (상악 단일 치아 임프란트의 후향적 연구)

  • Jo, Soo-Jin;Lee, Keun-Woo;Cho, Kyoo-Sung;Moon, Ik-Sang
    • Journal of Periodontal and Implant Science
    • /
    • v.33 no.3
    • /
    • pp.383-393
    • /
    • 2003
  • The aim of this retrospective study was to compare the amount of marginal bone loss between upper anterior area and upper posterior area with 71 upper single-tooth restorations on 2 stage machined $Br{{\aa}}nemark$ implants since Jan 1995. The second aim was to compare the bone defect group which had dehiscence and fenetration and the others in the upper anterior region. The results were as follows. 1. The most frequent reason of missing tooth in the upper anterior region was trauma by 61%. While upper posterior region showed various reasons such as congenital missing, advanced periodontitis, trauma. 2. Peri-implantitis with fistula occurred 1 of 41 implants in the upper anterior group in 1 year after loading and 2 of 32 implants in the upper posterior group failed before loading. The 1 year success rate of upper anterior group was 97.56 %, and 93.75 % for upper posterior group. 3. The mean marginal bone loss in the upper anterior group was 0.44${\pm}$0.25 mm, while 0.57${\pm}$0.32 mm in the upper posterior group. There was statistically significant difference in the amount of mean marginal bone loss (P${\pm}$0.10 mm at one year, and 0.48${\pm}$0.26 mm for the control group. No statistically significant difference of mean marginal bone loss was showen between bone defect group and the others at implantation. According to the results, the upper anterior region showed less marginal bone loss than the upper posterior region. In case of missing single upper tooth, careful consideration on recipient residual ridge to determine proper implant diameter and length, sufficient healing time, proper loading would lead to implant success. Single tooth implants in the maxilla seemed to be an alternative to fixed partial dentures without damage to adjacent teeth.

Estimation of critical current density of a YBCO coated conductor from a measurement of magnetization loss (자화손실 측정값으로부터 추정한 YBCO CC의 임계전류밀도 평가)

  • Lee, S.;Park, S.H.;Kim, W.S.;Lee, J.K.;Choi, K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.12 no.3
    • /
    • pp.16-20
    • /
    • 2010
  • For large scale power applications of HTS conductor, it is getting more important to have a stacked HTS coated conductor with low loss and large current capacity. But it was not easy to measure some electric properties. Stabilizer free YBCO CC for striated/ stacked conductors is easily burned out during the measurement of the critical current density because it has no stabilizer and it is difficult to set-up the current lead and voltage taps because it has many pieces of YBCO CC in a conductor. Instead of direct measuring the critical current of a stacked HTS coated conductor, indirect estimation from measuring a magnetization loss of HTS coated conductor could be useful for practical estimation of the critical current. The magnetization loss of a superconductor is supposed to be affected by a full penetrating magnetic field, and it tends to show an inflection point at the full penetrating magnetic field when we generate the graph of magnetization loss vs. external magnetic field. The full penetrating magnetic field depends on the shape of the conductor and its critical current density, so we can estimate the effective critical current density from measuring the magnetization loss. In this paper, to prove the effectiveness of this indirect estimation of the critical current, we prepared several different kinds of YBCO CC(coated conductor) including a stacked conductor short samples and measured the magnetization losses and the critical currents of each sample by using linked pick up coils and direct voltage measurement with transport current respectively.