• Title/Summary/Keyword: lead loss

Search Result 845, Processing Time 0.025 seconds

Development of Hybrid (Sb/Ca) Flooded Lead-Acid Battery for Minimizing Water Loss (감액 특성 향상을 위한 하이브리드(Sb/Ca) 액식 연축전지 개발)

  • Song, Seung Yun;Lim, Tae Seop;Kim, Sung Jun;Jung, Yeon-Gil;Yang, SeungCheol
    • Korean Journal of Materials Research
    • /
    • v.32 no.3
    • /
    • pp.146-152
    • /
    • 2022
  • One disadvantage of deep cycle flooded lead-acid batteries is increasing water loss caused by use of (+) Pb-Sb / (-) Pb-Sb alloy grid. Water loss is generated by the emission of hydrogen gas from the (-) electrode during battery charging. In this paper, we maintain cycle life aspect through the development of hybrid flooded lead-acid batteries to which a (+) Pb-Sb / (-) Pb-Ca grid is applied and deal with the improvement of water loss. The amount of water loss compared to that of the (-) Pb-Sb grid decreased when Ca was added to the (-) Pb grid. For the (-) Pb-Ca grid, it was confirmed that the time to reach 0.0 V, at which water decomposition occurs, was increased compared to that of the (-) Pb-Sb grid at the NPV (Negative Potential Voltage). In the cycle life test conducted with the BCI (Battery Council International) standard, compared to the (+) Pb-Ca grid, the (+) Pb-Sb grid increased the life cycle of the batteries and the (+) Pb-Ca grid showed an early end of life due to PbO corrosion layer generation, as determined through SEM / EDS and Tear Down analysis. In conclusion, by addition of Sb to (+) Pb grid and Ca to (-) Pb grid, we developed a hybrid flooded lead-acid battery that meets user requirements to improve water loss characteristics and preserve cycle life characteristics.

Transient characteristics of current lead losses for the large scale high-temperature superconducting rotating machine

  • Le, T.D.;Kim, J.H.;Park, S.I.;Kim, D.J.;Lee, H.G.;Yoon, Y.S.;Jo, Y.S.;Yoon, K.Y.;Kim, H.M.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.16 no.4
    • /
    • pp.62-65
    • /
    • 2014
  • To minimize most heat loss of current lead for high-temperature superconducting (HTS) rotating machine, the choice of conductor properties and lead geometry - such as length, cross section, and cooling surface area - are one of the various significant factors must be selected. Therefore, an optimal lead for large scale of HTS rotating machine has presented before. Not let up with these trends, this paper continues to improve of diminishing heat loss for HTS part according to different model. It also determines the simplification conditions for an evaluation of the main flux flow loss and eddy current loss transient characteristics during charging and discharging period.

The study on prevalence of color vision loss by residential difference of children (지역에 따른 어린이 색각이상의 유병율에 관한 연구)

  • Yu, Seungdo;Kim, Dae-Seon;Lee, Eun-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.4
    • /
    • pp.329-337
    • /
    • 2005
  • This study investigated prevalence of color vision loss different from children's residence. The study subjects are 3 to 6 grade's children of elementary school in four areas. The blood lead and urinary mercury were analysed using Atomic Absorption Spectroscopy. All of participations' blood lead and urine mercury concentration were below suggested level of concern such as criteria by CDC and ATSDR. Color vision was assessed by the Lanthony D-15 desaturated panel. Color vision loss was quantitatively established by the Color Confusion Index (CCI) and qualitatively classified by type of acquired dyschromatopsia according to Verriest's classification. The prevalence of color vision loss and CCI value for children in industrial area was significantly higher than other areas(p<0.05). However blood lead and urinary mercury concentration level was not correlated to the color vision loss. Therefore we believed that other environmental neurotoxic substance except metal had an effects on color vision loss for children in industrial area.

  • PDF

Effect of the voltage lead configurations on AC Loss Measurement in a Single Layer High-Tc Superconducting Model Cable (전압리드의 배치가 단층 고온초전도 모델케이블의 교류손실 측정에 미치는 영향)

  • 류경우;정재훈;황시돌;김석환
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.12
    • /
    • pp.670-675
    • /
    • 2002
  • AC loss is an important issue in the design of high-T$_{c}$ superconducting Power cables. The cables consists of a number of Bi-2223 tapes wound on a former. In such cables tapes have different critical current characteristics intrinsically. And they are electrically connected to each other and current leads by soldering. These make loss measurements considerably complex, especially for short samples of laboratory size. Special cautions are required in the positioning of voltage leads for measuring the true loss voltage. In this work the at losses in a single layer model cable have been experimentally investigated for different contacts and arrangements of voltage leads. The results show that the losses are not dependent on both arrangements and contact positions of the voltage leads. This implies that loss flux is only in a cylindrical conductor section. The measured losses also agree well with those based on a monoblock model and are independent of frequencies. This means that the measured AC loss of the model cable is purely hysteretic in nature.e.

Protective Effects of Activated Charcoal on the Acute Damages of Kidney of Mouse by Lead (급성 납 중독된 생쥐의 신장에서 활성탄의 보호효과)

  • Cheong, Min-Ju;Roh, Young-Bok
    • Applied Microscopy
    • /
    • v.36 no.2
    • /
    • pp.57-72
    • /
    • 2006
  • A protective effect of activated charcoal against the acute lead poisoning of kidney was studied in mice. Mice approximately 30 gm in weight were grouped into the control, lead acetate-treated. and the activated charcoal-treated after lead acetate groups. Lead acetate (60mg/kg) and activated charcoal (40mg/kg) were delivered orally. Serum BUN and creatine were measured and ultrastructural alteration of renal tissues were examined by electron microscopy. Activated charcoal were decreased the increase of serum BUN and Creatinine level induced by lead. Lead acetate-treated renal tissues were characterized by the loss of microvilli in the renal tubule tells, irregular nucleus, enlarged and reduced number of mitochodria, enlarged rough endoplasmic reticulum, loss of ribosomes. Cells treated with activated charcoal were similar to those of the control group. In conclusion, activated charcoal may protect the lead-induced toxicity on kidney.

Comparison of Novel Telemonitoring System Using the Single-lead Electrocardiogram Patch With Conventional Telemetry System

  • Soonil Kwon;Eue-Keun Choi;So-Ryoung Lee;Seil Oh;Hee-Seok Song;Young-Shin Lee;Sang-Jin Han;Hong Euy Lim
    • Korean Circulation Journal
    • /
    • v.54 no.3
    • /
    • pp.140-153
    • /
    • 2024
  • Background and Objectives: Although a single-lead electrocardiogram (ECG) patch may provide advantages for detecting arrhythmias in outpatient settings owing to user convenience, its comparative effectiveness for real-time telemonitoring in inpatient settings remains unclear. We aimed to compare a novel telemonitoring system using a single-lead ECG patch with a conventional telemonitoring system in an inpatient setting. Methods: This was a single-center, prospective cohort study. Patients admitted to the cardiology unit for arrhythmia treatment who required a wireless ECG telemonitoring system were enrolled. A single-lead ECG patch and conventional telemetry were applied simultaneously in hospitalized patients for over 24 hours for real-time telemonitoring. The basic ECG parameters, arrhythmia episodes, and signal loss or noise were compared between the 2 systems. Results: Eighty participants (mean age 62±10 years, 76.3% male) were enrolled. The three most common indications for ECG telemonitoring were atrial fibrillation (66.3%), sick sinus syndrome (12.5%), and atrioventricular block (10.0%). The intra-class correlation coefficients for detecting the number of total beats, atrial and ventricular premature complexes, maximal, average, and minimal heart rates, and pauses were all over 0.9 with p values for reliability <0.001. Compared to a conventional system, a novel system demonstrated significantly lower signal noise (median 0.3% [0.1-1.6%] vs. 2.4% [1.4-3.7%], p<0.001) and fewer episodes of signal loss (median 22 [2-53] vs. 64 [22-112] episodes, p=0.002). Conclusions: The novel telemonitoring system using a single-lead ECG patch offers performance comparable to that of a conventional system while significantly reducing signal loss and noise.

The Effect of Meteorological Information on Business Decision-Making with a Value Score Model (가치스코어 모형을 이용한 기상정보의 기업 의사결정에 미치는 영향 평가)

  • Lee, Ki-Kwang;Lee, Joong-Woo
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.30 no.2
    • /
    • pp.89-98
    • /
    • 2007
  • In this paper the economic value of weather forecasts is valuated for profit-oriented enterprise decision-making situations. Value is estimated in terms of monetary profits (or benefits) resulted from the forecast user's decision under the specific payoff structure, which is represented by a profit/loss ratio model combined with a decision function and a value score (VS). The forecast user determines a business-related decision based on the probabilistic forecast, the user's subjective reliability of the forecasts, and the payoff structure specific to the user's business environment. The VS curve for a meteorological forecast is specified by a function of the various profit/loss ratios, providing the scaled economic value relative to the value of a perfect forecast. The proposed valuation method based on the profit/loss ratio model and the VS is adapted for hypothetical sets of forecasts and verified for site-specific probability of precipitation forecast of 12 hour and 24 hour-lead time, which is generated from Korea meteorological administration (KMA). The application results show that forecast information with shorter lead time can provide the decision-makers with great benefits and there are ranges of profit/loss ratios in which high subjective reliability of the given forecast is preferred.

A study on the determination of lead in whole blood by ICP/MS (ICP/MS에 의한 전혈 중 납의 분석방법 연구)

  • Park, Kyung Su;Kim, Sun Tae
    • Analytical Science and Technology
    • /
    • v.10 no.4
    • /
    • pp.240-245
    • /
    • 1997
  • An accurate analysis method for the determination of lead in whole blood by ICP/MS was developed. Whole blood samples were decomposed in microwave digestion system without any contamination and loss of lead. The 96 samples were analyzed by ICP/MS using mass$^{208}$ isotope of lead. Lead concentrations of human whole blood were ranged of $2.50{\sim}22.8{\mu}g/dL$. The accuracy of this analysis method was verified by analyzing of NIST SRM 955a series(lead in blood).

  • PDF

Transport Loss Characteristics of a Bi-2223 Tape in External AC Magnetic Fields (외부 교류지장에 대한 Bi-2223테이프의 통전손실 특성)

  • Ryu, Kyung-Woo;Kim, Chang-Wan;Cha, Guee-Soo
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.6
    • /
    • pp.290-295
    • /
    • 2001
  • The transport loss of a Bi-2223 tape exposed to external magnetic fields was investigated. The results show that the transport loss is independent on voltage lead arrangements in case the magnetization loss is compensated. A serous increase of the transport loss due to external AC magnetic field is observed. The loss is described well by dynamic resistance loss in relatively high fields, but another mechanism than the dynamic resistance must be responsible for the increase of the loss in low fields. The transport loss is also dependent strongly on the orientation of the external fields.

  • PDF

The Influence of External Magnetic Field on Transport Loss in a Bi-2223 tape (외부자계가 Bi-2223테이프의 통전손실에 미치는 영향)

  • 김창완;한형주;류경우;최병주
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2001.02a
    • /
    • pp.169-171
    • /
    • 2001
  • The transport loss of a Bi-2223 tape exposed to external magnetic field was investigated. The results show that the transport loss is independent on voltage lead arrangements in case the magnetization loss is compensated. An serious increase of the transport loss due to external magnetic fields is observed. The loss is described well by dynamic resistance loss in relatively high fields, but another mechanism than the dynamic resistance must be responsible for the increase of the loss in low fields. The transport loss is also dependent strongly on the orientation of the applied field.

  • PDF