• Title/Summary/Keyword: lead II electrocardiography

Search Result 4, Processing Time 0.017 seconds

Subaortic Stenosis in Dogs. (개의 대동맥협착증)

  • 허진영;최지혜;최호정;이희천;이영원;박수원;엄기동;한정희;윤화영
    • Journal of Veterinary Clinics
    • /
    • v.16 no.2
    • /
    • pp.523-528
    • /
    • 1999
  • Subaortic stenosis in a 2.9kg, 3-month-old pug dog and a 11 kg, 4-month-old Rott -weiler dog showing signs of dyspnea, tachypnea, anorexia, exercise intolerance and depression was diagnosed with electrocardiography, thoracic radiography and ultrasonographic evaluation. In electrocardiography, PR interval widening, R wave amplitude increase in lead II in case 2, ST segment depression and left axis deviation in case 1 and 2 were identified. In thoracic radiographs, enlarged left ventricle and atrium, caudal displacement of left crus of diaphragm and caudal part of cranial mediastinum widening were identified in ventrodorsal view. In lateral view, left ventricular enlargement, secondary dorsal deviation of trachea and post-stenotic dilation of aorta were seen. Also, edematous pulmonary changes were shown in peri-hilar area. In ultrasonographic examination, left ventricular dilatation, pericardial effusion and subaortic valvular ridge were seen with real time B-mode in right parasternal long axis view. Aortic valve regurgitation was identified in color-Doppler mode.

  • PDF

The Verification of Photoplethysmography Using Green Light that Influenced by Ambient Light (녹색광을 이용한 반사형 광용적맥파측정기의 주변광 간섭시 신호측정)

  • Chang, K.Y.;Ko, H.C.;Lee, J.J.;Yoon, Young Ro
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.5
    • /
    • pp.125-131
    • /
    • 2014
  • The purpose of this study is to verify the utility of reflected photoplethysmography sensor using two green light emitting diodes that influenced by ambient light. Recently it has been studied that green light emitting diode is suitable for light source of reflected photoplethysmography sensor at low temperature and high temperature. Another study showed that, green light is better for monitoring heart rate during motion than led light. However, it has a bad characteristic about ambient light noise. To verify the utility of reflected photoplethysmography sensor using green light emitting diode, this study measures the photoplethysmography signal that is distorted by ambient light and will propose a solution. This study has two parts of research method. One is measurement system that composed sensor and board. The sensor is made up PE-foam and Non-woven fabric for flexible sensor. The photoplethysmography signal is measured by measurement board that composed high-pass filter, low-pass filter and amplifier. Ambient light source is light bulb and white light emitting diode that has three steps brightness. Photoplethysmography signal is measured with lead II electrocardiography signal at the same time and it is measured at the finger and radial artery for 1 minute, 1000 Hz sampling rate. The lead II electrocardiography signal is a standard signal for heart rate and photoplethysmography signal that measured at the finger is a standard signal for waveform. The test is repeated 3 times using three sensor. The data is processed by MATLAB to verify the utility by comparing the correlation coefficient score and heart rate. The photoplethysmography sensor using two green light emitting diodes is shown better utility than using one green light emitting diode and red light emitting diode at the ambient light. The waveform and heart rate that measured by two green light emitting diodes are more identical than others. The amount of electricity used is less than red light emitting diode and error peak detectability factor is the lowest.

A Study on the Measurement of Heart Rate Variability using the Modified Laplacian Electrodes (수정된 라플라시안 센서를 이용한 심박변이도 측정에 관한 연구)

  • Lee, Chung-Keun;Shin, Hang-Sik;Kim, Hong-Rae;Lee, Jeong-Whan;Kim, Yong-Jun;Lee, Myoung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.5
    • /
    • pp.1050-1056
    • /
    • 2009
  • Heart Rate Variability(HRV) is a parameter that represents monitoring variability of time intervals between R-peak in electrocardiography. HRV serves to various applications, such as indices of autonomic functions, prediction of cardiac sudden death, assessment of stress and emotional, etc. However, as measuring R-peak in ECG needs at least 3-electrodes, and it is inconvenient for end users. In this paper, we suggested the modified laplacian electrodes for measuring HRV at one-point, which are producted by MEMS fabrication and have the two circular electrodes on the pad. For optimal position and direction, we performed an experiment that compared with pearson correlation coefficient and the amplitude of signals, between standard lead II and proposed electrodes. We analyzed the HRV parameters, such as standard deviation of the NN interval(SDNN), high frequency(HF), low frequency(LF), LF/HF ratio. The result showed that the average correlation coefficient and amplitude are 0.967 and 0.685 mVpp at the position 2. The coeffiecient correlation between the standard HRV and proposed electrode-HRV is 0.999

Clinical Features of Isolated Noncompaction of the Ventricular Myocardium (심근의 단독 비경화증(Isolated Noncompaction of Ventricular Myocardium)의 임상 양상)

  • Moon, Eun-Kyoung;Lee, Hoon-Young;Chang, Mea-Young;Kil, Hong-Ryang;Chung, Yong-Hun
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.12
    • /
    • pp.1528-1533
    • /
    • 2002
  • Purpose : Isolated noncompaction of the ventricular myocardium(INVM) is one of the unclassified cardiomyopathies that is characterized by numerous, excessively prominent trabeculations, and deep intertrabecular recesses. We performed this study to evaluate the clinical features of INVM in children. Methods : The medical records of 10 patients with INVM were reviewed. We analyzed the clinical manifestations, hemodynamics, pattern of inheritance, and long-term prognosis of INVM in children. Results : Age at diagnosis was $45{\pm}53months$(1 day-14 years) with follow-up lasting as long as 78 months. Most INVM was asymptomatic on diagnosis. Associated cardiac anomalies were noted in six patients(ventricualr or atrial septal defect, patent ductus arteriosus with mitral valve prolapse, or mitral valve cleft). Depressed or flat changes of T wave in lead II, III and aVF were observed on electrocardiography. Various arrhythmia including WPW syndrome with paroxysmal supraventricular tachycardia, third-degree atrioventricular block, and familial sick sinus node dysfuction were observed. The degree of trabeculation in INVM was significantly prominent from level of mitral valve to apex compared to age-matched control. Familial recurrences were noted in two patients. The systolic function of the left ventricle was decreased in 20% of patients during the follow-up period, but systemic embolism or ventricular tachycardia was not observed. Conclusion : INVM is not a rare disorder. The cardiac function may be deteriorated in children as well as adults during long-term follow up. Thus early diagnosis and long-term follow-up must be done. So, the nation-wide multicenter clinical study would be mandatory to evaluate the incidence, long-term prognosis, and establishment of objective diagnostic criteria of INVM.