• Title/Summary/Keyword: latex method

Search Result 134, Processing Time 0.026 seconds

Evaluation of Air Void System and Permeability of Latex-Modified Concrete by Image Analysis Method

  • Jeong, Won-Kyong;Yun, Kyong-Ku;Hong, Seung-Ho
    • International Journal of Concrete Structures and Materials
    • /
    • v.19 no.1E
    • /
    • pp.41-48
    • /
    • 2007
  • Addition of latex to concrete is known to increase its durability and permeability. The purpose of this study is to analyze air void systems in latex-modified concretes using a reasonable and objective method of image analysis with such experimental variables as water-cement (w/c) ratios, latex contents (0%, 15%) and cement types (ordinary portland cement (OPC), high-early strength (HES) cement and very-early strength (VES) cement). The results are analyzed by spacing factor, air volume (content) after hardening, air void distribution and structure. Additionally, air void systems and permeability of latex-modified concrete (LMC) are compared by a correlation analysis. The results are as follows. The LMC of the same w/c ratio showed better air entraining (AE) effect than OPC with AE water reducer. The VES-LMC showed that the quantity of entrained air below $100{\mu}m$ increased more than four times. For the case of HES-LMC, microscopic entrained air between the range of 50 to $500{\mu}m$ increased greater than 7 times even in the absence of anti-foamer. Although spacing factor was measured rather low, the permeability of latex-modified concrete was good. It is construed that air void system does not have a considerable effect on the property of latex-modified concrete, but latex film (membrane) has a definite influence on the durability of LMC.

Strength Properties and Determination Method of Mix Proportion Factor of Latex Modified Concrete (라텍스개질 콘크리트의(LMC)의 강도특성 및 배합인자 결정방법)

  • Park, Sung-Ki;Won, Jong-Pil;Park, Chan-Gi
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.50 no.5
    • /
    • pp.39-50
    • /
    • 2008
  • This study are decided the mix proportion method of latex modified concrete for agricultural concrete structures from the results of workability and strength test with mix proportion factor. For mix proportion factor, this study are selected the water-cement ratio, unit cement amount and latex content. Also, this study were performed the slump, compressive strength test and microstructure analysis using the scanning electron microscope(SEM). The strength and slump of LMC are dependent with unit cement amount, latex content, and water-cement ratio. Especially, the strength of LMC are not controlled by single mix proportion factor but effected by combined mix proportion factor. Microstructure investigation are showed the LMC are reduced the internal pore volume and enhanced the transition zone between cement paste and aggregate interface. This effect get by consist of latex films in the concrete. Also, this study were recommended the mix proportion method for LMC. These mix proportions method are estimated the mix design for satisfied the target performance which are applied the agricultural concrete structure.

A study on the Coating Structure and Printability of Coated Paper (I) - Effect of Ionic Monomer on Paper-coating Latex Properties - (도공층 구조 및 도공지의 인쇄적성에 관한 연구 (I) - 이온성 단량체가 도공용 라텍스의 물성에 미치는 영향 -)

  • Lee, Yong-Kyu
    • Journal of the Korean Wood Science and Technology
    • /
    • v.25 no.3
    • /
    • pp.75-82
    • /
    • 1997
  • To improve the quality of coated paper, the continuous research to the coating components and development of alternative latices is required. Recently, amphoteric latex is getting a great concern due to their changable properties of surface charge through controlling pH and some methods have been tried to prepare amphoteric latices. This study was carried out to synthesize amphoteric latex using seeding polymerization method with low concentration emulsifier. Styrene was used as a main monomer in addition to acrylonitrile for a hydrophilic comonomer. acrylic acid for a anionic comonomer and N,N-dimethylaminoethyl methacrylate for a cationic comonomer. Particle size and viscosity of latex were greatly affected by addition of acrylic acid and ammonium persulfate as an initiator. Negative charge of latex in alkali condition was changed to zero to positive charge in around pH 4.

  • PDF

The Quantitative Analysis of SB Latex Contents in Coating Color and Coating Layer of Coated Paper Using FT/Raman Spectroscopy (FT/RAman을 이용한 도공액과 도공지의 도공층 내의 SB Latex 정량분석)

  • 이복진;정순기;윤동호;마금자
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.31 no.4
    • /
    • pp.16-22
    • /
    • 1999
  • The quantitative analysis of SB latex contents in coating color and coated paper was investigated with FT/Raman spectroscopy. From the measured FT/IR and FT/Ramon spectra, the peaks of coating color were compared with those of each compoents . Calibration curves were obtained by the area of latex peaks and PLS method of QuantIR program. The relation of predicted values in PLS method and actual values in coating mixtures and coating layer was examined. The components of coating layer in coated paper were investigated by EDS , X-mapping and SEM, The contents of latex in z-direction were calculated in the coating layer of unknown coated paper. The latex concentration measurements of Top layer and Pre layer in double coated paper show that each layer has different value. In single coated paper, it is clear that the latex concentration is highest at the surface and decreases with an increase of depth. From those results it is indicated that the latex migrates to the coated surface. The result of this study may be applied to the binder migration study and the quality control in paper mill.

  • PDF

Separation of ${\alpha}-,\;{\gamma}-,\;{\delta}-tocotrienol$ from latex (천연 latex로부터 ${\alpha}-,\;{\gamma}-,\;{\delta}-tocotrienol$의 분리)

  • Lee, Hyung-Ok
    • Applied Biological Chemistry
    • /
    • v.36 no.1
    • /
    • pp.29-32
    • /
    • 1993
  • 3 $Tocotrienol-{\alpha}-,\;{\gamma}-\;and\;{\delta}-tocotrienol-from$from latex(Hevea Brasiliensis) were isolated and the oily tocotrienol concentrates obtained. To isolate tocotrienols, the fractionation by semipreparative HPLC of the unsaponifiable fraction in the raw lipid extract from latex was carried out. By this method, the total content of tocotrienols in latex was ca. 400 ppm, and the purities of ${\alpha}-,\;{\gamma}-\;and\;{\delta}-tocotrienol$ were 98.3, 99.3 and 96.2%, respectively.

  • PDF

Preparation and Application Characteristics of Carboxylated Styrene Butadiene Latex for Latex Modified Concrete (라텍스 개질 콘크리트용 Carboxylated Styrene Butadiene 라텍스의 제조와 적용 특성)

  • Lee, Bong-Kyu;Ju, Chang-Sik
    • Korean Chemical Engineering Research
    • /
    • v.50 no.6
    • /
    • pp.1076-1081
    • /
    • 2012
  • For the purpose of development of the latex suitable for latex modified concrete, experimental researches on the preparation of carboxylated styrene butadiene latex by the method of the two-step emulsion polymerization and application to concrete were performed. Sodium dodecylbenzene sulfonate and sodium salt of lauryl sulfonate were selected as anionic emulsifiers, and nonylphenoxy poly(ethyleneoxy) ethanols (n=10, 20, 40) as latex stabilizer. Potassium persulfate and sodium bisulfite were used as redox initiator, besides $Na_2HPO_4$ and $K_2CO_3$ as electrolytes. Polymerization recipe of latex suitable for latex modified concrete were suggested from the experimental researches on the effects of anionic emulsifiers and their concentration on the polymerization stability, and the effect of electrolytes concentration on the particle size of latex. Physical properties, such as slump, air contents, compressive and flexural strength, of latex prepared by suggested polymerization recipe were examined. The experimental results showed that latex modified concrete satisfied the quality standards in slump and air contents. Furthermore, it was turned out that the compressive and the flexural strength of latex modified concrete with 28 days curing time showed appreciably improvements.

A Consideration on Thermal Stability of the PVAc Latex Adhesive (PVAc 라텍스 접착제의 열적 안정성에 대한 고찰)

  • 권재범;이내우;설수덕
    • Journal of the Korean Society of Safety
    • /
    • v.18 no.3
    • /
    • pp.81-87
    • /
    • 2003
  • Latex polymers are widely used for adhesive, binder, paint etc. Especially the PVAc(Polyvinyl acetate) latex which manufactured by vinyl acetate and vinyl alcohol as protective colloid is a useful environmentally friendly adhesive. To increase useful property of PVAc latex, this study was carried out for checking thermal characteristics and physical condition of PVAc latex by DSC, FT-IR, Pyrolyzer GC-MS. The activation energies of thermal decomposition for 40, 48, 56, 64% solid content of PVAc latex were found as 28.1-36.0kcal/mol by Kissinger's method and 17.2-22.0kcal/mol by DSC method. Actually, reasonable solid content could be consiered as 56% because of activation energy and adhesive characteristics. According to the effect of protective colloid for 4, 10, 15, 20wt%, the activation energy shows same tendency to both method and in case of l5wt% has been found as the highest activation energy. The mechanism of thermal decomposition was mainly estimated by main chain scission, not by side group on FT-IR analysis. Main component of Pyrolzer GC-MS result were consisted of $CH_3COOH$, $CH_3$, $H_2O$ and light gases(CO, $CO_2$, $CH_4$ etc).

Surface Modification of Latex with Parylene by Chemical Vapor Deposition (화학기상증착법의 Parylene 코팅에 의한 천연 라텍스 표면개질)

  • Song, Jeom-Sik;Choi, Seo-Yoon;Jung, Seong-Hee;Cha, Gook-Chan;Lee, Suk-Min;Mun, Mu-Seong
    • Elastomers and Composites
    • /
    • v.39 no.4
    • /
    • pp.301-308
    • /
    • 2004
  • Three types of parylene (PA-N, PA-C, PA-D) were used for coating the surface on natural latex rubbers in order to improve surface characteristics including mechanical properties and biocompatibility. The parylene coating was the CVD (chemical vapor deposition) method, and the surface properties of the modified latex were measured. Annealing effects on the mechanical properties of the coated latex were also investigated. The adhesion between latex and parylene was good for all the types of parylene used. As annealing temperature was increased, latex modified with PA-N became more hydrophobic, while the latex treated with PA-C and PA-D became more hydrophilic. As the annealing temperature was raised, the tensile strength was increased, and the elongation was decreased. The biocompatibility was noticeably improved on the latex surface modified with the parylenes through CVD method.

A Detection Kit for Aeromonas hydrophila Using Antibody Sensitized Latex

  • Shin, En-Joo;Lee, Soon-Deuk;Lee, Kyung-Won;Lee, Yeon-Hee
    • Journal of Microbiology and Biotechnology
    • /
    • v.10 no.5
    • /
    • pp.595-598
    • /
    • 2000
  • Aeromonas hydrophila is a pathogen to fish as well as human. It is a food-borne disease, and causes severe mortality in fish, and sometimes severe septicemia in human. In this study, a rapid detection method using latex agglutination has been developed for A. hydrophila. Polyclonal antibodies were raised against membrane and whole cells of three isolates from rainbow trout. Among these, latex particles coated with antibodies raised against whole cells of isolate No. 2 showed the best sensitivity. With latex particles coated with this antibody, we could detect $5{\times}10^4$ CFU of A. hydrophila in 5 min. The cross-reactivity with bacteria constituting the normal intestinal microflora and other pathogens for rainbow trout was insignificant. This latex agglutination assay method produced positive reaction with all clinical isolates of A. hydrophila which were identified by species-specific PCR for 16S rRNA in A. hydrophila.

  • PDF

Analysis of Air Void Systems in Latex-Modified Concretes with Cement Types (시멘트 종류에 따른 라텍스개질 콘크리트의 미세공극 구조 분석)

  • Yun, Kyong-Ku;Jeong, Won-Kyong;Kim, Ki-Heun;Kim, Kyong-Jin
    • International Journal of Highway Engineering
    • /
    • v.7 no.1 s.23
    • /
    • pp.73-82
    • /
    • 2005
  • Linear traverse method and point count method described at ASTM have been widely used to estimate the air void system in hardened concrete. These methods, however, are rarely used at present, because they require many efforts and time consuming works. Also these results depend on each person's decision, and are not repeatable. Thus, new image analysis method using microscope and computer processes has been approached for analyzing air void system in hardened concrete. The purpose of this study was to analysis the air void systems in latex-modified concretes using a reasonable and objective image analysis method with main experimental variables such as cement types(ordinary portland cement, rapid setting cement) and latex contents(0%,15%). In the results of this study, the use of polymer latex showed that it could be attributed to its air void systems, due to the fact that the latex emulsion acts as an air-entraining agent, which thus generally guarantees an adequate air-void system.

  • PDF