• 제목/요약/키워드: lateral wall

검색결과 942건 처리시간 0.026초

Strengthening of hollow brick infill walls with perforated steel plates

  • Aykac, Sabahattin;Kalkan, Ilker;Seydanlioglu, Mahmut
    • Earthquakes and Structures
    • /
    • 제6권2호
    • /
    • pp.181-199
    • /
    • 2014
  • The infill walls, whose contribution to the earthquake resistance of a structure is generally ignored due to their limited lateral rigidities, constitute a part of the lateral load bearing system of an RC frame structure. A common method for improving the earthquake behavior of RC frame structures is increasing the contribution of the infill walls to the overall lateral rigidity by strengthening them through different techniques. The present study investigates the influence of externally bonded perforated steel plates on the load capacities, rigidities, and ductilities of hollow brick infill walls. For this purpose, a reference (unstrengthened) and twelve strengthened specimens were subjected to monotonic diagonal compression. The experiments indicated that the spacing of the bolts, connecting the plates to the wall, have a more profound effect on the behavior of a brick wall compared to the thickness of the strengthening plates. Furthermore, an increase in the plate thickness was shown to result in a considerable improvement in the behavior of the wall only if the plates are connected to the wall with closely-spaced bolts. This strengthening technique was found to increase the energy absorption capacities of the walls between 4 and 14 times the capacity of the reference wall. The strengthened walls reached ultimate loads 30-160% greater than the reference wall and all strengthened walls remained intact till the end of the test.

점성토로 뒤채움된 중력식옹벽에서의 인장균열 및 수평토압 : 비배수 해석 (Tension Crack and Lateral Pressure on Gravity Wall Backfilled by Cohesive Soil : Undrained Analysis)

  • 정성교;김형수
    • 한국지반공학회지:지반
    • /
    • 제13권4호
    • /
    • pp.135-148
    • /
    • 1997
  • 옹벽에 작용하는 토압을 구하기 위하여 Coulomb이론이 실무에 대부분 사용되고 있지만, 전수평토압의 작용위치를 구할 수 없으므로 토압분포를 삼각형 분포라고 가정하고 있다. 그러나, 수 많은 실내 및 현장실험을 통하여 토압분포가 그렇지 않다는 것으로 규명되었다. 이러한 문제를 극복하기 위한 이론적인 접근이 Handy(1985), Kingsley(1989), Kellogg(1993), 정성교(1993, 1996a) 등에 의하여 비 점성토로 뒤채움된 옹벽에 대하여 수행되었다. 점성토로 뒤채움된 옹벽에 대한 기존의 이론적 접근은 단지 Rankine또는 Coulomb 이론에 근거하여 주로 수행되었지만, 그 이론들은 제각기 다른 결과를 보여주었다. 여기서는 점성토로 뒤채움된 중력식옹벽에 작용하는 수평토압을 위한 이론적 접근이 비배수 조건하에서 수행되었다. 이 접근은 Coulomb의 가정에 바탕을 두고 아칭개념을도입하였으며, 인장균열을 무시한 경우와 고려한 경우에 대하여 각각 이론식이 유도되었다. 그리고, 몇가지 조건에 대한 비교결과에서 인장균열을 고려한 토압이론식의 적용이 합리적일 것으로 사료되었다.

  • PDF

고층건물의 횡변위에 대한 커플링보의 효과 (The Effects of Coupling Beam on Lateral Drift of High-rise Buildings)

  • 김진상
    • 한국산학기술학회논문지
    • /
    • 제12권12호
    • /
    • pp.5931-5937
    • /
    • 2011
  • 본 연구에서는 고층건물의 횡변위 구조형식으로 널리 사용되는 전단벽-커플링보 구조시스템에서 커플링보가 건물의 횡변위에 미치는 영향을 분석하였다. 기본해석모델로는 벽체와 기둥의 콘크리트 강도와 벽체두께에 따라 6가지를 선택하였다. 이 모델을 기본으로 하여 커플링보의 강성을 변화시켜 해석을 수행하였다. 해석프로그램으로는 MIDAS GEN을 이용하였다. 해석결과로부터 각각의 해석모델들의 최상층 횡변위와 CEN EC 3/1에서 규정하고 있는 횡변위 허용 범위(H/400~H/500)를 비교하고 분석함으로써 커플링보의 횡변위 제어능력을 평가 하였다. x방향 횡변위는 허용 횡변위(H/500)의 68%~87%정도로서 벽체두께 100mm 증가에 따라 약 8%~10%의 횡변위 감소가 있음을 확인하였고, 콘크리트 강도가 5Mpa 증가함에 따라 횡변위는 약 4%의 감소 효과가 있는 것으로 분석되었으며, 두 경우 모두 x, y방향에 대하여 유사한 결과가 나타난 것으로 확인되었다. 커플링보 강성저하에 따른 횡변위 비율은 허용변위 기준인 H/500를 기준하여 분석결과 최초 강성 20% 저하 시 횡변위는 3%정도의 변위 증가가 나타났으며, 추가 20% 저하 시 5%~8%의 변위가 발생되었다.

점증하중에 의한 강성벽체에 작용하는 토압 (Earth Pressures Acting on the Rigid Wall under Incremental Load)

  • 전용백;권욱화
    • 한국산업융합학회 논문집
    • /
    • 제5권3호
    • /
    • pp.247-254
    • /
    • 2002
  • This study has researched the following conclusion to compare to the existing theory and to examine lateral earth pressure, which have measured to add incremental load on sandy soil, and were different in types of compaction by modeling earth pressure test. Lateral earth pressure by incremental load shows that it is increasing at depth forty four centimeters as 2/3H point for wall high, and under 2/3 H point the variation of earth pressure on incremental load is not conspicuous. Therefor, the more a position of surcharge load is close with fixed wall, the more a variation of lateral earth pressure marks considerably. According to relative compaction density of soil, lateral earth pressure turns up larger effective value for layer compaction test to a thickness of thirty three centimeters than layer compaction test to a thickness of twenty centimeters by the roller.

  • PDF

Lateral loading test for partially confined and unconfined masonry panels

  • Tu, Yi-Hsuan;Lo, Ting-Yi;Chuang, Tsung-Hua
    • Earthquakes and Structures
    • /
    • 제18권3호
    • /
    • pp.379-390
    • /
    • 2020
  • Four full-scaled partially confined and unconfined masonry panels were tested with monotonic lateral loads. To study the effects of vertical force and boundary columns, two specimens with no boundary columns were subjected to different vertical forces, while two wing-wall specimens had the column placed eccentrically and in the middle, respectively. The specimens with no boundary columns exhibited ductile rocking behavior, where the lateral strength increased with increasing vertical compression. The wing-wall specimens with columns behaved as strut-and-tie systems. The column-panel interaction resulted in greater strength, lower deformation capacity and differences in failure modes. A comparison with analytical models showed that rocking strength can be accurately estimated using vertical force and the panel aspect ratio for panels with no boundary columns. The estimation for lateral strength on the basis of a panel section area indicated scattered error for wing-wall specimens.

단면현상에 따른 벽식구조 전단벽의 구조성능 평가 (Structural Performance of Shearwall with Sectional Shape in Wall-type Apartment Buildings)

  • 한상환;오영훈;오창학;이리형
    • 콘크리트학회논문집
    • /
    • 제12권4호
    • /
    • pp.3-14
    • /
    • 2000
  • Structural performance of the walls subjected to lateral load reversals depends on various parameters such as loading history, sectional shape, reinforcement, lateral confinement, aspect ratio, axial compression, etc. Thus, the performance of the shearwall for wall-type apartment should be evaluated properly considering above parameters. This study investigates the effect of sectional shape on the structural performance of the wall. Sectional shape of the specimen is rectangular, barbell and T. Based on this experimental results, all specimens behaved as ductile fashion and failed by concrete crushing of the compression zone. Deformation index of those specimens evaluated better than 3 of ductility ratio, and 1.5% of deformability specified by seismic provision. Moreover, the performance of the rectangular shaped specimen, whose compression zone was confined with U-bar and cross tie, was as good as the barbell shaped specimen. Therefore, if we considered construction practice such as workmanship and detailing, shearwall with rectangular section may be more economical lateral load resisting system.

선반식 옹벽의 수평토압에 관한 모형시험과 수치해석 비교 (Comparison of the Lateral Earth Pressure on the Retaining Wall with the Relieving Platform by Model test and Numerical Analysis)

  • 유완규;김병일;문인종;박용석
    • 한국산학기술학회논문지
    • /
    • 제13권5호
    • /
    • pp.2382-2389
    • /
    • 2012
  • 일반적으로 높이가 높아짐에 따라 옹벽의 안정성과 경제성은 작아지는데 이런 경우 선반식 옹벽이 효과적으로 사용될 수 있다. 선반식 옹벽의 선반은 전체 토압을 감소시켜주어 옹벽의 안정성을 향상시켜준다. 이 연구에서는 일반적으로 선반이 설치되는 위치인 지표면으로부터 0.4H지점에 선반을 설치한 선반식 옹벽과 캔틸레버식 옹벽에 작용하는 토압분포에 대한 모형시험 결과를 수치해석 프로그램과 이론해를 이용한 토압과 비교하여 선반식 옹벽에 발생하는 토압 경감효과를 확인하고자 하였다. 모형시험결과와 유한요소해석 프로그램 및 이론해에 의한 토압산정 결과를 종합해 볼 때 선반식 옹벽은 캔틸레버식 옹벽에 비해서 수평토압이 감소하는 것을 알 수 있고, 선반을 설치하여 발생하는 토압의 감소효과는 뚜렷한 것으로 나타났다.

골조-전단벽 구조에서 상부 전단벽 미배치의 구조효과 (Structural Effect on Curtailment of Upper Shear Wall in Frame-Shear Wall Structure)

  • 김형기
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제20권5호
    • /
    • pp.18-25
    • /
    • 2016
  • 본 연구는 MIDAS-Gen을 사용하여 골조-전단벽 구조에서 상부 전단벽의 미배치에 대한 구조적인 효과를 검토하였다. 본 연구에서는 해석 변수로 상부 전단벽의 미배치 층수, 상하 기둥 단면 치수의 변화, 상하 전단벽 두께 치수의 변화를 설정하였다. 골조-전단벽 구조에서 상부 전단벽의 미배치에 대한 구조적인 효과를 검토하기 위하여 전단벽의 미배치에 따른 전단력/전도모멘트 분포, 전단벽의 변곡점, 수평강성에 대하여 비교분석하였다. 본 연구의 결과는 골조-전단벽 구조에서 상부 전단벽의 미배치가 수평강성과 같은 구조성능에 미치는 영향을 정량적으로 제시하였다. 더욱이 본 연구의 결과는 합리적인 골조-전단벽 구조를 위한 구조설계 자료를 제공하는데 도움이 된다고 확인하였다.

반복-횡력을 받는 조적벽 골조와 전단벽 골조의 내력 및 연성에 관한 실험적 연구 (Experimental Study of Strength and Ductility on Masonry Wall Frame and Shear Wall Frame Subjected to Cyclic Lateral Loading)

  • 이호;변상민;정환목;이택운
    • 한국공간구조학회논문집
    • /
    • 제13권2호
    • /
    • pp.83-91
    • /
    • 2013
  • The core aim of this dissertation is to empirically scrutinize a strength characteristic of beam-column frame subjected to the cyclic lateral load, a beam-column frame of un-reinforced masonry wall, and a shear wall frame. First and foremost, I embark upon making three prototypes vis-$\grave{a}$-vis this research. By conducting this process, I touch on an analysis of cyclic behavior and a damage characteristic of the beam-column frame, the beam-column frame of un-reinforced masonry wall, and the shear wall frame. What is more, through the previous procedure, the next part delves into the exact stress transfer path and the destructive mechanism to examine how much and how strong the beam-column frame of un-reinforced Masonry Wall does have a resistance capacity against earthquake in all the architecture constructed by the above-mentioned frame, as well as school buildings. In addition to the three prototypes, two more experimental models, a beam-column frame and shear wall frame, are used to compare with the beam-column frame of un-reinforced masonry wall. Lastly, the dissertation will suggest some solutions to improve the resistance capacity against earthquake regarding all constructions built with non bearing wall following having examining precisely all the analysis with regard to not only behavior properties and the damage mechanism of the beam-column frame and the beam-column frame of un-reinforced Masonry Wall but also the resistance capacity against earthquake of non bearing wall and school buildings.

Analytical simulation of reversed cyclic lateral behaviors of an RC shear wall sub-assemblage

  • Lee, Han Seon;Jeong, Da Hun;Hwang, Kyung Ran
    • Computers and Concrete
    • /
    • 제10권2호
    • /
    • pp.173-196
    • /
    • 2012
  • Experimental results of cyclic reversed lateral force test on a two-story reinforced concrete shear wall sub-assemblage are simulated analytically by using the PERFORM-3D program. A comparison of experimental and analytical results leads to the following conclusions: (1) "Shear Wall" and "General Wall" models with "Concrete shear" cannot simulate the pinching phenomena due to shear and show larger amounts of inelastic energy absorption than those in the experiment. (2) Modeling a story-height wall by using two or more "General Wall" elements with "Diagonal shear" in the vertical direction induces the phenomenon of swelling-out at the belly, leading to the erroneous simulation of shear behaviors. In application to tall building structures, it is recommended to use one element of "General Wall" with "Diagonal shear" for the full height of a story. (3) In the plastic hinge area, concrete deformations of analytical models overestimate elongation and underestimate shortening when compared with experimental results.