• Title/Summary/Keyword: lateral section

Search Result 547, Processing Time 0.029 seconds

A Study on the Moment Gradient factor of Mono-symmetric I Beam (일축 대칭 I 형 보의 모멘트 구배계수에 대한 연구)

  • 김윤종;임남형;박남회;강영종
    • Proceedings of the KSR Conference
    • /
    • 2000.05a
    • /
    • pp.439-446
    • /
    • 2000
  • In this study, 7 dof (Including warping) beam element was developed to estimate the effects of wagner effects and load height effects on the lateral buckling strength of mono-symmetric I beam. Finite element buckling analysis of mono-symmetric I-shaped girders subjected to transverse loading applied at different heights on the cross-section were conducted. Linear moment gradient were considered, too. In these cases, girders are subjected to both single-curvature and Reverse-curvature bending. An applicability of current LRFD C$\sub$b/ on the mono-symmetric I beam was studied from the finite element results. The problems of current LRFD C$\sub$b/ occurring from load height effects and reverse curvature bending in unbraced length when applied on the mono-symmetric I beam were studied. Solutions to these problems are also presented.

  • PDF

Aberrant Left Hepatic Artery Arising from Left Gastric Artery at Curative Gastrectomy for Gastric Cancer

  • An, Chansik;Lim, Joon-Seok
    • Journal of International Society for Simulation Surgery
    • /
    • v.1 no.2
    • /
    • pp.87-89
    • /
    • 2014
  • An aberrant left hepatic artery is one of the most common variants of hepatic arteries, and its prevalence has been reported 6.5-30%. During D2 lymph node dissection for gastric cancer, an aberrant left hepatic artery arising from left gastric artery is ligated which may lead to hepatic damage. In this case report, a 66-year-old male patient underwent total gastrectomy with D2 lymph node dissection during which the aberrant left hepatic artery was ligated. Post-operative liver function tests revealed elevated liver enzymes, and ischemic changes in the left lateral hepatic section was seen on the CT scan. On retrospective review of preoperative CT images, a replaced left hepatic artery from left gastric artery could have been identified. The information on the presence of aberrant LHA and its supplying area is clinically important when planning curative gastrectomy for gastric cancer, because extended lymph node dissection requires division of the left gastric artery and this may lead to severe liver damage. By using preoperative CT scan, detection of aberrant left hepatic artery could be done.

A Study of the Modification Factor(B) in the AISC Specification for Elastic Buckling of Web-Tapered Beams (웨브 변단면보의 탄성좌굴에 대한 AISC 기준의 수정계수(B)에 관한 연구)

  • Ryu, Hyo-Jin;Lim, Nam-Hyoung
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.2
    • /
    • pp.45-49
    • /
    • 2008
  • This paper investigated the accuracy of the current design formulae for the elastic buckling strength of web-tapered I-beams in AISC-LRFD specification. The basic concept is to replace a tapered beam by an equivalent prismatic beam with a different length, but with a cross section identical to that of the smaller end of the tapered beam. The modification factor, B, is used to account for the stress gradient within the unbraced length and the lateral restraining effects offered by the adjacent segments. The modification factor(B) suggested in AISC-LRFD specification was compared with the finite element method(FEM) results. This paper presented a redefined method to calculate the modification factor(B).

Development of a user-friendly and transparent non-linear analysis program for RC walls

  • Menegon, Scott J.;Wilson, John L.;Lam, Nelson T.K.;Gad, Emad F.
    • Computers and Concrete
    • /
    • v.25 no.4
    • /
    • pp.327-341
    • /
    • 2020
  • Advanced forms of structural design (e.g., displacement-based methods) require knowledge of the non-linear force-displacement behavior of both the overall building and individual lateral load resisting elements, i.e., walls or building cores. Similarly, understanding the non-linear behaviour of the elements in a structure can also allow for a less conservative structural response to be calculated by better understanding the cracked (i.e., effective) properties of the various RC elements. Calculating the non-linear response of an RC section typically involves using 'black box' analysis packages, wherein the user may not be in complete control nor be aware of all the intricate settings and/or decisions behind the scenes. This paper introduces a user-friendly and transparent analysis program for predicting the back-bone force displacement behavior of slender (i.e., flexure controlled) RC walls, building cores or columns. The program has been validated and benchmarked theoretically against both commonly available and widely used analysis packages and experimentally against a database of 16 large-scale RC wall test specimens. The program, which is called WHAM, is written using Microsoft Excel spreadsheets to promote transparency and allow users to further develop or modify to suit individual requirements. The program is available free-of-charge and is intended to be used as an educational tool for structural designers, researchers or students.

Minimum stiffness of bracing for multi-column framed structures

  • Aristizabal-Ochoa, J. Dario
    • Structural Engineering and Mechanics
    • /
    • v.6 no.3
    • /
    • pp.305-325
    • /
    • 1998
  • A method that determines the minimum stiffness of baracing to achieve non-sway buckling conditions at a given story level of a multi-column elastic frame is proposed. Condensed equations that evaluate the required minimum stiffness of the lateral and torsional bracing are derived using the classical stability functions. The proposed method is applicable to elastic framed structures with rigid, semirigid, and simple connections. It is shown that the minimum stiffness of the bracing required by a multi-column system depends on: 1) the plan layout of the columns; 2) the variation in height and cross sectional properties among the columns; 3) the applied axial load pattern on the columns; 4) the lack of symmetry in the loading pattern, column layout, column sizes and heights that cause torsion-sway and its effects on the flexural bucking capacity; and 5) the flexural and torsional end restrains of the columns. The proposed method is limited to elastic framed structures with columns of doubly symmetrical cross section with their principal axes parallel to the global axes. However, it can be applied to inelastic structures when the nonlinear behavior is concentrated at the end connections. The effects of axial deformations in beams and columns are neglected. Three examples are presented in detail to show the effectiveness of the proposed method.

Low strength concrete members externally confined with FRP sheets

  • Ilki, Alper;Kumbasar, Nahit;Koc, Volkan
    • Structural Engineering and Mechanics
    • /
    • v.18 no.2
    • /
    • pp.167-194
    • /
    • 2004
  • In this paper axial loading tests on low strength concrete members, which were confined with various thickness of carbon fiber reinforced polymer (CFRP) composite sheets are described. Totally 46 specimens with circular, square and rectangular cross-sections with unconfined concrete compressive strengths between 6 and 10 MPa were included in the test program. During the tests, a photogrammetrical deformation measurement technique was also used, as well as conventional measurement techniques. The contribution of external confinement with CFRP composite sheets to the compressive behavior of the specimens with low strength concrete is evaluated quantitatively, in terms of strength, longitudinal and lateral deformability and energy dissipation. The effects of width/depth ratios and the corner radius of the specimens with rectangular cross-section on the axial behavior were also examined. It was seen that the effectiveness of the external confinement with CFRP composite sheets is much more pronounced, when the unconfined concrete compressive strength is relatively lower. It was also found that the available analytical expressions proposed for normal or high strength concrete confined by CFRP sheets could not predict the strength and deformability of CFRP confined low strength concrete accurately. New expressions are proposed for the compressive strength and the ultimate axial strain of CFRP confined low strength concrete.

Experimental study of a pretensioned connection for modular buildings

  • Yu, Yujie;Chen, Zhihua;Chen, Aoyi
    • Steel and Composite Structures
    • /
    • v.31 no.3
    • /
    • pp.217-232
    • /
    • 2019
  • Modular steel buildings consist of prefabricated room-sized structural units that are manufactured offsite and installed onsite. The inter-module connections must fulfill the assembly construction requirements and soundly transfer the external loads. This work proposes an innovative assembled connection suitable for modular buildings with concrete-filled steel tube columns. The connection uses pretensioned strands and plugin bars to vertically connect the adjacent modular columns. The moment-transferring performance of this inter-module connection was studied through monotonic and cyclic loading tests. The results showed that because of the assembly construction, the connected sections were separated under lateral bending, and the prestressed inter-module connection performed as a weak semirigid connection. The moment strength at the early loading stage originated primarily from the contact bonding mechanism with the infilled concrete, and the postyield strength depended mainly on the tensioned strands. The connection displayed a self-centering-like behavior that the induced deformation was reversed during unloading. The energy dissipation originated primarily from frictional slipping of the plugin bars and steel strands. The moment transferring ability was closely related to the section dimension and the arrangements of the plugin bars and steel strands. A simplified strength calculation and evaluation method was also proposed, and the effectiveness was validated with the test data.

Seismic Response Analysis of Twisted Buildings with Three Planar Shapes (세 가지 평면 형상에 따른 비틀림 비정형 빌딩구조물의 지진응답 분석)

  • Lee, Da-Hye;Kim, Hyun-Su;Kang, Joo-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.21 no.4
    • /
    • pp.23-30
    • /
    • 2021
  • In this paper, a twisted shape structure with an elevation form favorable to the resistance of vibration caused by wind loads is selected from among the forms of high-rise buildings. The analytical model is a square, triangular, and hexagonal plane with a plane rotation angle of one degree from 0 to 3 degrees per each story. As a result of the analysis, as the twist angle increased, story drift ratio is increased. Responses with different eccentricity rates were shown by analytical models. Therefore planar shapes designed symmetrically to the horizontal axis of X and Y are considered advantageous for eccentricity and torsion deformation. In the case of the bending moment of the column, the response was amplified in the column supporting the base floor, the roof floor, the floor in which the cross-section of the vertical member changes, and the floor having the same number of nodes as the base floor. Finally, the axial force response of the column is determined to be absolutely affected by the gravity load compared to the lateral load.

Semi analytical solutions for flexural-torsional buckling of thin-walled cantilever beams with doubly symmetric cross-sections

  • Gilbert Xiao;Silky Ho;John P. Papangelis
    • Structural Engineering and Mechanics
    • /
    • v.87 no.6
    • /
    • pp.541-554
    • /
    • 2023
  • An unbraced cantilever beam subjected to loads which cause bending about the major axis may buckle in a flexuraltorsional mode by deflecting laterally and twisting. For the efficient design of these structures, design engineers require a simple accurate equation for the elastic flexural-torsional buckling load. Existing solutions for the flexural-torsional buckling of cantilever beams have mainly been derived by numerical methods which are tedious to implement. In this research, an attempt is made to derive a theoretical equation by the energy method using different buckled shapes. However, the results of a finite element flexural-torsional buckling analysis reveal that the buckled shapes for the lateral deflection and twist rotation are different for cantilever beams. In particular, the buckled shape for the twist rotation also varies with the section size. In light of these findings, the finite element flexural-torsional buckling analysis was then used to derive simple accurate equations for the elastic buckling load and moment for cantilever beams subjected to end point load, uniformly distributed load and end moment. The results are compared with previous research and it was found that the equations derived in this study are accurate and simple to use.

Hyperkinetic Rat Model Induced by Optogenetic Parafascicular Nucleus Stimulation

  • Moonyoung Chung;Young Seok Park
    • Journal of Korean Neurosurgical Society
    • /
    • v.66 no.2
    • /
    • pp.121-132
    • /
    • 2023
  • Objective : The parafascicular nucleus (PF) plays important roles in controlling the basal ganglia. It is not well known whether the PF affects the development of abnormal involuntary movements (AIMs). This study was aimed to find a role of the PF in development of AIMs using optogenetic methods in an animal model. Methods : Fourteen rats were underwent stereotactic operation, in which they were injected with an adeno-associated virus with channelrhodopsin (AAV2-hSyn-ChR2-mCherry) to the lateral one third of the PF. Behavior test was performed with and without optical stimulation 14 days after the injection of the virus. AIM of rat was examined using AIM score. After the behavior test, rat's brain was carefully extracted and the section was examined using a fluorescence microscope to confirm transfection of the PF. Results : Of the 14 rats, seven rats displayed evident involuntary abnormal movements. AIM scores were increased significantly after the stimulation compared to those at baseline. In rats with AIMs, mCherry expression was prominent in the PF, while the rats without AIM lacked with the mCherry expression. Conclusion : AIMs could be reversibly induced by stimulating the PF through an optogenetic method.