• 제목/요약/키워드: lateral drift

검색결과 282건 처리시간 0.024초

CFT와 합성보로 이루어진 CJS합성구조시스템의 내진성능 실험 연구 (Experimental Study of the Seismic Performance of CJS Hybrid Structural Systems Connected to the CFT Column)

  • 임창규;신지욱;문아해;김용남;이기학
    • 한국지진공학회논문집
    • /
    • 제26권2호
    • /
    • pp.83-93
    • /
    • 2022
  • In this study, to verify the structural performance of the Composite Joint System (CJS) hybrid structural model, a cyclic load test was performed and evaluated and verified through the test. To verify the structural performance of the CJS hybrid structural systems' joint and evaluate the seismic performance, four three-dimensional real-size specimens were developed with three internal beam-column specimens and one external beam-column specimen. The three interior column specimens were classified by different methods of joining the upper column and lower column, and the same bonding method as the primary specimen was used for the exterior column. The structural performances in terms of drift, strength, and energy dissipation capacity were analyzed and compared based on the experimental results. From the displacement-based loading experiment, all specimens showed a lateral drift of 4.0% without any significant strength drop and stable energy dissipation capacity.

철근 콘크리트 특수 모멘트 골조 건물의 비탄성 동적 요구값 (Inelastic Dynamic Demands of a RC Special Moment Frame Building)

  • 김태완
    • 한국지진공학회논문집
    • /
    • 제9권5호
    • /
    • pp.11-19
    • /
    • 2005
  • 건축 구조물의 내진 설계는 탄성 정적 방법에 기초하고 있으나, 강진시 구조물의 실제 거동은 비탄성 동적이기 때문에 설계 규준의 적합성을 판단하기 위해서는 비탄성 동적 해석이 요구된다. 본 논문에서는 철근 콘크리트 특수 모멘트 저항 골조 건물을 선택하여 IBC 2003에 따라 설계한 후, 선택된 부재들의 최대 소성 회전, 소산 에너지를 구하여, 건물의 비탄성 거동이 규준에서 의도한 거동을 보이는 지를 검토함과 동시에 층간변위률 요구값을 구하여 설계 한도를 만족하는 지를 조사하였다. 더불어 비횡력 저항 시스템인 내부 모멘트 저항 골조의 해석시 포함 여부의 영향도 함께 조사하였다. 해석 결과 IBC 2003에 의해 설계된 건물은 규준이 의도한 비탄성 거동을 보여주었으며 층간변위률 또한 설계한도를 만족하였다. 그리고, 내부 모멘트 저항 골조는 지진 해석 결과에 중요한 영향을 미치므로 해석 모델에 반드시 포함되어야 함을 알수 있었다.

Seismic deformation demands on rectangular structural walls in frame-wall systems

  • Kazaz, Ilker
    • Earthquakes and Structures
    • /
    • 제10권2호
    • /
    • pp.329-350
    • /
    • 2016
  • A parametric study was conducted to investigate the seismic deformation demands in terms of drift ratio, plastic base rotation and compression strain on rectangular wall members in frame-wall systems. The wall index defined as ratio of total wall area to the floor plan area was kept as variable in frame-wall models and its relation with the seismic demand at the base of the wall was investigated. The wall indexes of analyzed models are in the range of 0.2-2%. 4, 8 and 12-story frame-wall models were created. The seismic behavior of frame-wall models were calculated using nonlinear time-history analysis and design spectrum matched ground motion set. Analyses results revealed that the increased wall index led to significant reduction in the top and inter-story displacement demands especially for 4-story models. The calculated average inter-story drift decreased from 1.5% to 0.5% for 4-story models. The average drift ratio in 8- and 12-story models has changed from approximately 1.5% to 0.75%. As the wall index increases, the dispersion in the calculated drifts due to ground motion variability decreased considerably. This is mainly due to increase in the lateral stiffness of models that leads their fundamental period of vibration to fall into zone of the response spectra that has smaller dispersion for scaled ground motion data set. When walls were assessed according to plastic rotation limits defined in ASCE/SEI 41, it was seen that the walls in frame-wall systems with low wall index in the range of 0.2-0.6% could seldom survive the design earthquake without major damage. Concrete compressive strains calculated in all frame-wall structures were much higher than the limit allowed for design, ${\varepsilon}_c$=0.0035, so confinement is required at the boundaries. For rectangular walls above the wall index value of 1.0% nearly all walls assure at least life safety (LS) performance criteria. It is proposed that in the design of dual systems where frames and walls are connected by link and transverse beams, the minimum value of wall index should be greater than 0.6%, in order to prevent excessive damage to wall members.

Fragility functions for eccentrically braced steel frame structures

  • O'Reilly, Gerard J.;Sullivan, Timothy J.
    • Earthquakes and Structures
    • /
    • 제10권2호
    • /
    • pp.367-388
    • /
    • 2016
  • Eccentrically braced frames (EBFs) represent an attractive lateral load resisting steel system to be used in areas of high seismicity. In order to assess the likely damage for a given intensity of ground shaking, fragility functions can be used to identify the probability of exceeding a certain damage limit-state, given a certain response of a structure. This paper focuses on developing a set of fragility functions for EBF structures, considering that damage can be directly linked to the interstorey drift demand at each storey. This is done by performing a Monte Carlo Simulation of an analytical expression for the drift capacity of an EBF, where each term of the expression relies on either experimental testing results or mechanics-based reasoning. The analysis provides a set of fragility functions that can be used for three damage limit-states: concrete slab repair, damage requiring heat straightening of the link and damage requiring link replacement. Depending on the level of detail known about the EBF structure, in terms of its link section size, link length and storey number within a structure, the resulting fragility function can be refined and its associated dispersion reduced. This is done by using an analytical expression to estimate the median value of interstorey drift, which can be used in conjunction with an informed assumption of dispersion, or alternatively by using a MATLAB based tool that calculates the median and dispersion for each damage limit-state for a given set of user specified inputs about the EBF. However, a set of general fragility functions is also provided to enable quick assessment of the seismic performance of EBF structures at a regional scale.

Seismic response analysis of steel frames with post-Northridge connection

  • Mehrabian, Ali;Haldar, Achintya;Reyes-Salazar, Alfredo
    • Steel and Composite Structures
    • /
    • 제5권4호
    • /
    • pp.271-287
    • /
    • 2005
  • The seismic behavior of two steel moment-resisting frames, which satisfy all the current seismic design requirements, are evaluated and compared in the presence of pre-Northridge connections denoted as BWWF and an improved post-Northridge connections denoted as BWWF-AD. Pre-Northridge connections are modeled first as fully restrained (FR) type. Then they are considered to be partially restrained (PR) to model their behavior more realistically. The improved post-Northridge connections are modeled as PR type, as proposed by the authors. A sophisticated nonlinear time-domain finite element program developed by the authors is used for the response evaluation of the frames in terms of the overall rotation of the connections and the maximum drift. The frames are excited by ten recorded earthquake time histories. These time histories are then scaled up to produce some relevant response characteristics. The behaviors of the frames are studied comprehensively with the help of 120 analyses. Following important observations are made. The frames produced essentially similar rotation and drift for the connections modeled as FR type and PR type represented by BWWF-AD indicating that the presence of slots in the web of beams in BWWF-AD is not detrimental to the overall response behavior. When the lateral displacements of the frames are significantly large, the responses are improved if BWWF-AD type connections are used in the frames. This study analytically confirms many desirable features of BWWF-AD connections. PR frames have longer periods of vibration in comparison to FR frames and may attract lower inertia forces. However, calculated periods of the frames of this study using FEMA 350 empirical equation is longer than those calculated using dynamic characteristics of the frames. This may result in even lower design forces and may adversely influence the design.

Optimum position for outriggers of different materials in a high- rise building

  • Nikhil Y. Mithbhakare;Popat D. Kumbhar
    • Earthquakes and Structures
    • /
    • 제25권5호
    • /
    • pp.359-367
    • /
    • 2023
  • High-rise structures are considered as symbols of economic power and leadership. Developing countries like India are also emerging as centers for new high-rise buildings (HRB). As the land is expensive and scarce everywhere, construction of tall buildings becomes the best solution to resolve the problem. But, as building's height increases, its stiffness reduces making it more susceptible to vibrations due to wind and earthquake forces. Several systems are available to control vibrations or deflections; however, outrigger systems are considered to be the most effective systems in improving lateral stiffness and overall stability of HRB. In this paper, a 42-storey RCC HRB is analyzed to determine the optimum position of outriggers of different materials. The linear static analysis of the building is performed with and without the provision of virtual outriggers of reinforced cement concrete (RCC) and pre-stressed concrete (PSC) at different storey levels by response spectrum method using finite element based Extended3D Analysis of building System (ETABS) software for determining responses viz. storey displacement, base shear and storey drift for individual models. The maximum allowable limit and percentage variations in earthquake responses are verified using the guidelines of Indian seismic codes. Results indicate that the outriggers contribute in significantly reducing the storey displacement and storey drift up to 28% and 20% respectively. Also, it is observed that the PSC outriggers are found to be more efficient over RCC outriggers. The optimum location of both types of outriggers is found to be at the mid height of building.

낙엽송 집성재의 Bolt, Drift Pin 접합부의 전단강도 성능 평가 - 접합구 직경, 세장비, 끝면거리가 강도에 미치는 영향 - (Shearing Strength Properties of Bolted, Drift-Pinned Joints of the Larix Glulam - Effects of Fastener Diameter, Slenderness and End-distance on Strength Properties -)

  • 김건호;홍순일
    • Journal of the Korean Wood Science and Technology
    • /
    • 제36권1호
    • /
    • pp.69-78
    • /
    • 2008
  • 국내산 낙엽송 집성재 볼트, 드리프트 핀 접합부의 내력성능평가를 위해 인장형 전단강도시험을 실시하였다. 인장형 전단시편은 강판삽입형 볼트, 드리프트 핀 접합부 시편과 강판측재형 볼트접합부시편으로 제작하였다. 실험에 사용된 볼트와 드리프트 핀의 직경은 12, 16, 20 mm였다. 시편의 접합구멍은 끝면거리 5, 7 d로 제작하였고 인장하중은 섬유평행방향으로 가하였다. 끝면거리에 따른 접합부의 내력성능을 검토하고 Larsen의 항복추정식을 통해 항복하중을 실측항복하중과 비교하였다. 설계표준 시 끝면거리 7 d의 항복하중을 기준으로 5 d의 저감계수를 산출하였다. 본 연구의 결과는 다음과 같다. 1. 강판삽입형 접합부에서 드리프트 핀 접합부의 평균최대하중은 직경이 증가함에 따라 볼트 접합부보다 3~30% 정도 크게 나타났다. 볼트 접합부의 경우 강판측재형의 평균최대하중은 강판삽입형보다 1.54~2.07배 크게 나타났다. 동일 직경에서 끝면거리 7 d의 평균최대하중이 5 d보다 8~44% 정도 크게 나타났다. 2. 강판삽입형 접합부의 지압응력은 드리프트 핀 접합부가 볼트보다 1.16~1.41배 더 크게 나타났으며, 7 d가 5 d보다 1.37~1.86배 크게 나타났다. 또한 드리프트 핀 접합부의 세장비는 7.5 이하, 강판삽입형 볼트 접합부의 세장비는 6 이하에서 양호한 내력성능을 보였다. 3. 실측 항복하중과 Larsen이 제안한 항복하중 추정식에 의해 얻어진 항복하중값의 비는 강판삽입형 접합부의 경우 0.80~1.10, 강판측재형 접합부는 0.75~1.46이었다. 4. 끝면거리 7 d의 항복하중을 기준으로 강판삽입형 볼트접합부의 경우 12 mm 접합부의 저감계수(Ke)는 0.89, 16 mm는 0.93, 20 mm는 0.85였다. 강판삽입형 드리프트 핀 접합부의 경우 12 mm는 0.89, 16 mm는 0.93, 20 mm는 0.93이었다. 강판측재형 직경 12 mm 볼트접합부의 저감계수는 0.79, 16 mm는 0.80이었다.

기둥-보 휨강도비와 단위하중법을 이용한 철골모멘트골조의 강성설계기법 (Drift Design Method of Steel Moment Frames by using Column-Beam Strength Ratios and Unit-Load Method)

  • 오병관;박효선;최세운
    • 한국전산구조공학회논문집
    • /
    • 제29권6호
    • /
    • pp.563-569
    • /
    • 2016
  • 본 논문에서는 철골모멘트골조의 초기 강성과 연성을 동시에 조절하기 위해 기둥-보 휨강도비를 고려한 재분배 기법이 제시된다. 제시되는 기법은 총 구조물량과 기둥-보 휨강도비에 대한 제약조건을 만족시키면서 구조물의 최상층의 변위를 최소화한다. 고려된 설계변수는 구조부재의 단면적을 사용하며, 정식화된 문제로부터 최적의 결과를 얻기 위해 Sequential Quadratic Programming(SQP) 기법을 사용한다. 최상층의 횡변위에 대한 각 부재의 변위기여도를 단위하중법을 통해 구하고, 이를 최상층의 횡변위가 감소하도록 각 부재의 단면을 재설계한다. 각 부재의 변위기여도를 이용하여 부재의 단면을 재설계하는 과정은 구조물의 초기 강성을 향상시키는 효과를 가진다. 동시에, 제시된 기법은 기둥-보 휨강도비를 제약함으로써 구조물의 연성을 조절하도록 한다. 제시된 최적변위설계기법은 철골골조 예제에 적용하여 적용성을 검증한다. 적용한 결과 제시된 기법을 통해 구조물의 초기강성과 연성능력이 조절되는 것을 확인할 수 있었다.

입체 복합구조물의 하부골조 층수 변화에 따른 비선형 거동특성 (The Nonlinear Behavior Characteristics of the 3D Mixed Building Structures with Variations in the Lower Stories)

  • 강병두;전대한;김재웅
    • 한국지진공학회논문집
    • /
    • 제6권1호
    • /
    • pp.55-62
    • /
    • 2002
  • 상부벽식-하부골조 구조(복합구조)는 일반적으로 전이층을 중심으로 상부는 주거공간의 전단벽식의 고층아파트이고 하부는 상업공간의 보-기등의 골조구조이다. 이러한 구조물은 구조형식의 특성상 강성비정형, 질량비정형, 기하학적 비정형 등 비정형 형태의 특징을 갖고 있다. 본 연구에서는 하부골조 구조물의 층수가 변화할 경우에 대해 복합 구조물의 비선형 거동특성과 내진성능을 파악하였다. 비선형 해석결과로부터 얻은 결론은 다음과 같다. 1) 비선형 정적해석의 최상층변위각과 밑면전 단력계수로부터 하부구조의 층수가 증가할 경우 구조물의 밑면전단력계수는 감소하였으나 최상층변위각은 증가하였다. 2) 하부구조의 층수가 증가할 경우 상부벽식구조의 층간변위각과 소성율은 감소하였으며, 상부벽식은 탄성상태에 가까운 거동을 하였다. 3) 하부구조의 층수가 증가할 경우 하부구조에서 층간변위각이 집중적으로 증가하였다.

The motion rule of sand particles under control of the sand transportation engineering

  • Xin, Lin-gui;Cheng, Jian-jun;Chen, Bo-yu;Wang, Rui
    • Wind and Structures
    • /
    • 제27권4호
    • /
    • pp.213-221
    • /
    • 2018
  • In the desert and Gobi regions with strong wind and large sediment discharge, sand transporting engineering is more effective than sand blocking and sand fixing measures in sand prevention. This study uses the discrete phase model of 3D numerical simulation to study the motion trail, motion state and distribution rule of sand particles with different grain diameters when the included angle between the main shaft of the feather-row lateral transportation sand barrier and the wind direction changes, and conducts a comparison in combination with the wind tunnel test and the flow field rule of common sand barrier. According to the comparison, when wind-sand incoming flow passes through a feather-row sand barrier, sand particles slow down and deposit within the deceleration area under the resistance of the feather-row sand barrier, move along the transportation area formed by the transportation force, and accumulate as a ridge at the tail of the engineering. With increasing wind speed, the eolian erosion of the sand particles to the ground and the feather-row sand barrier is enhanced, and the sand transporting quantity and throw-over quantity of the feather-row sand barrier are both increased. When sand particles with different grain diameters bypass the feather-row sand barrier, the particle size of the infiltrating sands will increase with the included angle between the main shaft of the feather-row sand barrier and the wind direction. The obtained result demonstrates that, at a constant wind speed, the flow field formed is most suitable for the lateral transportation of the wind-drift flow when the included angle between the main shaft of the feather-row sand barrier lateral transportation engineering and the wind speed is less than or equal to $30^{\circ}$.