• 제목/요약/키워드: lateral cyclic testing

검색결과 39건 처리시간 0.026초

Seismic behavior of thin-walled CFST pier-to-base connections with tube confined RC encasement

  • Xuanding Wang;Yue Liao;Jiepeng Liu;Ligui Yang;Xuhong Zhou
    • Steel and Composite Structures
    • /
    • 제50권2호
    • /
    • pp.217-235
    • /
    • 2024
  • Concrete-filled steel tubes (CFSTs) nowadays are widely used as the main parts of momentous structures, and its connection has gained increasing attention as the complexity in configuration and load transfer mechanism. This paper proposes a novel CFST pier-to-footing incorporating tube-confined RC encasement. Such an innovative approach offers several benefits, including expedited on-site assembly, effective confinement, and collision resistance and corrosion resistance. The seismic behavior of such CFST pier-to-footing connection was studied by testing eight specimens under quasi-static cyclic lateral load. In the experimental research, the influences on the seismic behavior and the order of plastic hinge formation were discussed in detail by changing the footing height, axial compression ratio, number and length of anchored bars, and type of confining tube. All the specimens showed sufficient ductility and energy dissipation, without significant strength degradation. There is no obvious failure in the confined footing, while local buckling can be found in the critical section of the pier. It suggests that the footing provides satisfactory strength protection for the connection.

Damage and deformation of new precast concrete shear wall with plastic damage relocation

  • Dayang Wang;Qihao Han;Shenchun Xu;Zhigang Zheng;Quantian Luo;Jihua Mao
    • Steel and Composite Structures
    • /
    • 제48권4호
    • /
    • pp.385-403
    • /
    • 2023
  • To avoid premature damage to the connection joints of a conventional precast concrete shear wall, a new precast concrete shear wall system (NPSW) based on a plastic damage relocation design concept was proposed. Five specimens, including one monolithic cast-in-place concrete shear wall (MSW) as a reference and four NPSWs with different connection details (TNPSW, INPSW, HNPSW, and TNPSW-N), were designed and tested by lateral low-cyclic loading. To accurately assess the damage relocation effect and quantify the damage and deformation, digital image correlation (DIC) and conventional data acquisition methods were used in the experimental program. The concrete cracking development, crack area ratio, maximum residual crack width, curvature of the wall panel, lateral displacement, and deformed shapes of the specimens were investigated. The results showed that the plastic damage relocation design concept was effective; the initial cracking occurred at the bottom of the precast shear wall panel (middle section) of the proposed NPSWs. The test results indicated that the crack area ratio and the maximum residual crack width of the NPSWs were less than those of the MSW. The NPSWs were deformed continuously; significant distortions did not occur in their connection regions, demonstrating the merits of the proposed NPSWs. The curvatures of the middle sections of the NPSWs were lower than that of the MSW after a drift ratio of 0.5%. Among the NPSWs, HNPSW demonstrated the best performance, as its crack area ratio, concrete damage, and maximum residual crack width were the lowest.

Force-based seismic design of steel haunch retrofit for RC frames

  • Ahmad, Naveed
    • Earthquakes and Structures
    • /
    • 제20권2호
    • /
    • pp.133-148
    • /
    • 2021
  • The paper presents a simplified force-based seismic design procedure for the preliminary design of steel haunch retrofitting for the seismic upgrade of deficient RC frames. The procedure involved constructing a site-specific seismic design spectrum for the site, which is transformed into seismic base shear coefficient demand, using an applicable response modification factor, that defines base shear force for seismic analysis of the structure. Recent experimental campaign; involving shake table testing of ten (10), and quasi-static cyclic testing of two (02), 1:3 reduced scale RC frame models, carried out for the seismic performance assessment of both deficient and retrofitted structures has provided the basis to calculate retrofit-specific response modification factor Rretrofitted. The haunch retrofitting technique enhanced the structural stiffness, strength, and ductility, hence, increased the structural response modification factor, which is mainly dependent on the applied retrofit scheme. An additional retrofit effectiveness factor (ΩR) is proposed for the deficient structure's response modification factor Rdeficient, representing the retrofit effectiveness (ΩR=Rretrofitted /Rdeficient), to calculate components' moment and shear demands for the retrofitted structure. The experimental campaign revealed that regardless of the deficient structures' characteristics, the ΩR factor remains fairly the unchanged, which is encouraging to generalize the design procedure. Haunch configuration is finalized that avoid brittle hinging of beam-column joints and ensure ductile beam yielding. Example case study for the seismic retrofit designs of RC frames are presented, which were validated through equivalent lateral load analysis using elastic model and response history analysis of finite-element based inelastic model, showing reasonable performance of the proposed design procedure. The proposed design has the advantage to provide a seismic zone-specific design solution, and also, to suggest if any additional measure is required to enhance the strength/deformability of beams and columns.

Experimental and analytical study of squat walls with alternative detailing

  • Leonardo M. Massone;Cristhofer N. Letelier;Cristobal F. Soto;Felipe A. Yanez;Fabian R. Rojas
    • Computers and Concrete
    • /
    • 제33권5호
    • /
    • pp.497-507
    • /
    • 2024
  • In squat reinforced concrete walls, the displacement capacity for lateral deformation is low and the ability to resist the axial load can quickly be lost, generating collapse. This work consists of testing two squat reinforced concrete walls. One of the specimens is built with conventional detailing of reinforced concrete walls, while the second specimen is built applying an alternative design, including stirrups along the diagonal of the wall to improve its ductility. This solution differs from the detailing of beams or coupling elements that suggest building elements equivalent to columns located diagonally in the element. The dimensions of both specimens correspond to a wall with a low aspect ratio (1:1), where the height and length of the specimen are 1.4 m, with a thickness of 120 mm. The alternative wall included stirrups placed diagonally covering approximately 25% of the diagonal strut of the wall with alternative detailing. The walls were tested under a constant axial load of 0.1f'cAg and a cyclic lateral displacement was applied in the upper part of the wall. The results indicate that the lateral strength is almost identical between both specimens. On the other hand, the lateral displacement capacity increased by 25% with the alternative detailing, but it was also able to maintain the 3 complete hysteretic cycles up to a drift of 2.5%, reaching longitudinal reinforcement fracture, while the base specimen only reached the first cycle of 2% with rapid degradation due to failure of the diagonal compression strut. The alternative design also allows 46% more energy dissipation than the conventional design. A model was used to capture the global response, correctly representing the observed behavior. A parametric study with the model, varying the reinforcement amount and aspect ratio, was performed, indicating that the effectiveness of the alternative detailing can double de drift capacity for the case with a low aspect ratio (1.1) and a large longitudinal steel amount (1% in the web, 5% in the boundary), which decreases with lower amounts of longitudinal reinforcement and with the increment of aspect ratio, indicating that the alternative detailing approach is reasonable for walls with an aspect ratio up to 2, especially if the amount of longitudinal reinforcement is high.

장기내구성을 고려한 EPS의 현장 적용성 (Application of EPS Considering Long-term Durability)

  • 천병식;정창희;안진현
    • 한국지반환경공학회 논문집
    • /
    • 제8권6호
    • /
    • pp.53-60
    • /
    • 2007
  • EPS는 일반적으로 블록형태로 제조되어 토목공사에 이용되고 있으며, 재료특성상 초경량성 및 내압축성을 가지며 자립안정성이 우수하므로 연약지반상 성토재로 적용한 경우 침하 및 측방유동에 대한 대책공법으로 적용되고 있다. 현재 국내에서는 보온 재료로서의 시험 방법 및 품질 규정만이 KS에 규정되어 있고, 공학적 성토 재료로서 활용하기 위한 기준이 확립되어 있지 않다. 따라서 도로공사의 시험시공 및 제조사의 품질시험을 통하여 EPS 설계 기준을 마련하여 적용하고 있는데, 이것들은 주로 재료의 공장제품 즉, 새 제품에 국한되어 연구가 이루어져 왔다. 본 연구에서는 EPS 장기내구성에 주안점을 두어 교대측방유동 대책공법으로 EPS가 적용된 시공현장에서 채취한 EPS시료와 공장제품에 대해 반복재하시험, 동결융해시험, 흡수율시험 등을 통하여 공학적인 장기내구성을 비교 분석하였다. 그 결과 일축압축시험은 채취시료가 공장제품에 비해서 강도가 다소 작게 나타났으며, 삼축압축시험에서 채취시료와 공장제품 모두 일축압축 시험결과에서와 같이 구속응력은 축방향 변형량에 선형비례하는 경향을 나타내었으며, 응력-변형률 관계곡선의 양상은 구속압과 상관없이 유사함을 알 수 있었다.

  • PDF

철도 고가교 기둥의 내진성능에 관한 실험적 연구 (An Experimental Study of Seismic Retrofit on the Viaduct Bridge of Rail Transit)

  • 김진호;신홍영;박연준;허진호
    • 한국철도학회논문집
    • /
    • 제15권6호
    • /
    • pp.616-622
    • /
    • 2012
  • 지진으로 인한 철도 고가교의 심각한 손상이 발생할 경우 구조물의 복구에 필요한 직접적인 손실과 통행제한에 따른 막대한 사회 간접적 손실이 발생한다. 따라서 철도 고가교 구조물은 적절한 내진성능을 확보하여야 하나, 기존 철도 시설에 대한 내진성능평가 결과 다수의 구조물에 대한 내진보강이 필요한 것으로 나타났다. 본 연구에서는 5개의 고가교 기둥 축소모형을 제작하고, 4개의 기둥에 대하여 기존 보강공법의 단점을 개선한 HT-A 복합플레이트로 기둥을 보강하였다. 축력과 반복횡하중을 동시에 가하는 기둥의 실험을 실시하여 강성, 연성 및 에너지 소산능력 등의 내진성능을 평가한 결과 HT-A 복합플레이트로 보강된 철도 고가교 기둥의 향상된 내진성능을 확인하였다.

축소모델실험에 의한 철근콘크리트 3층 보통모멘트골조의 구조 성능 평가 (Seismic Performance Evaluation of 3 Story OMRCF Based on Scaled Model Testing)

  • 한상환;권건업
    • 콘크리트학회논문집
    • /
    • 제17권5호
    • /
    • pp.673-678
    • /
    • 2005
  • ACI 318(1999) 규준에서는 모멘트골조를 특수모멘트골조, 중간모멘트골조, 보통모멘트골조의 3가지로 구분하고 있다. 이중 중 약 지진 지역에서는 대부분의 구조물이 보통모멘트골조로 설계되고 있다. 이러한 보통모멘트골조는 현행 규준에서 가장 엄격하지 않은 상세와 요구사항이 적용되는 골조 형식이다 본 연구는 중력하중으로만 설계되고 ACI 318(1999) 기준의 보통모멘트골조의 상세만을 가지는 3층의 사무소 건물의 내진 성능 평가를 그 목표로 한다 실험적 연구를 위하여 1/3 축소 모델을 제작하여 준정적 실험을 실시하였다. 보통모멘트골조의 전체적인 거동은 갑작스러운 강도의 저감 없이 안정적인 거동을 하였다 실험결과, 중력하중으로만 설계된 3층의 사무소건물은 UBC 1997 규준의 지진 지역 1, 2A, 2B에서의 요구하는 설계 밑면전단력보다 더 큰 횡력 저항 능력을 가지고 있는 것으로 나타났다.

AE와 DRA를 이용한 초기응력의 측정에 관한 연구 (In-situ Stress Measurement Using AE and DRA)

  • 박배한;전석원;김양균
    • 한국터널지하공간학회 논문집
    • /
    • 제3권1호
    • /
    • pp.51-62
    • /
    • 2001
  • AE와 DRA를 이용한 초기응력 측정법은 실험실 시험을 통해 초기응력을 측정하는 방법 중의 하나이다. 이 방법은 시추와 실험실 시험간에 지연시간이 발생하며 시료에 축방향 반복하중을 가하여 초기응력을 결정하기 때문에 지하 암반의 응력 상태와는 다른 결과를 얻을 수도 있다. 이 연구에서는 지연시간을 다르게 하여 지연시간이 선행응력 결정에 미치는 영향을 살펴보았다. 그리고 축방향 선행응력만을 가한 시료와 축방향 선행응력과 봉압을 모두 가한 시료에 대해 AE와 DRA를 이용하여 선행응력을 결정하여 봉압이 축방향 선행응력 결정에 미치는 영향을 살펴보았다. 지연시간이 길어질수록 오차가 약간씩 증가하는 경향이 나타났으나 지연시간이 1개월인 시료라 할지라도 AE와 DRA를 이용한 경우 각각 16%와 12%의 오차범위 내에서 선행응력을 결정할 수 있었다. 축방향 선행응력만을 가한 경우 AE를 이용하면 9%, DRA를 이용하면 4%의 오차범위 내에서 축방향 선행응력을 결정할 수 있었으나 축방향 선행응력과 봉압을 모두 가한 경우는 각각 17%와 14%의 오차범위 내에서 축방향 선행응력을 결정할 수 있었다. 터널현장에서 시추한 코어를 이용하여 초기응력을 측정한 결과 AE와 DRA는 유사한 결과를 나타내었으나 수압파쇄법에 의한 결과보다는 작은 값을 갖는 것으로 나타났다.

  • PDF

T형 벽체의 유효 폭 및 휨강도 평가 (Evaluation of the Effective Width and Flexural Strength of the T-Stalled Walls)

  • 양지수;이리형
    • 콘크리트학회논문집
    • /
    • 제14권5호
    • /
    • pp.796-803
    • /
    • 2002
  • T형 벽체는 웨브 벽체와 평행한 방향으로 횡력이 작용할 때 그 작용 방향에 따라 다른 강성과 강도를 갖는다. 특히, 플랜지벽체에 인장력이 작용할 때 플랜지 벽체내 철근의 기여로 인하여 벽체의 휨강도가 상승하게 되는데 이것은 전단지체 현상에 기인한 것이다. 이러한 전단지체 현상에 따라 플랜지 벽체는 전체 폭이 웨브 벽체와 일체로 거동하지 못하고, 일정한 부분만이 웨브 벽체와 함께 거동하게 되는데, 이러한 범위를 유효 폭이라 하며, 이러한 유효 폭은 구조물의 실제적인 강도와 강성을 예측하는데 중요한 역할을 하게되므로 반드시 구명되어야 할 요소라 할 수 있다. 이에 본 연구에서는 실험을 통하여 웨브 벽체 단부에 기존의 양단부 보강상세를 갖는 T형 벽체의 실제적인 강도와 유효 폭을 평가하고자 한다. 연구목적을 달성하기 위하여 3개의 실험체를 제작하였으며 0.1 $f_{ck}$ . $A_{g}$의 축력을 실험이 진행되는 동안 일정하게 유지하면서, 반복가력 실험을 수행하였다. 실험결과, 유효 폭은 횡변위의 증가에 따라 증가하는 것으로 나타났으며 최대강도 발현시 h/3에 해당하는 전체 플랜지가 유효 폭으로 작용하는 것으로 나타났다. 그러므로, PCI나 국내 기준에 의한 h/10의 유효 폭은 웨브 벽체 단부에 주어진 보강상세를 갖는 벽체에 대하여 적절치 못한 것으로 사료된다..