• Title/Summary/Keyword: lateral control

Search Result 1,458, Processing Time 0.041 seconds

Comparison between the Calculated and Measured Doses in the Rectum during High Dose Rate Brachytherapy for Uterine Cervical Carcinomas (자궁암의 고선량율 근접 방사선치료시 전산화 치료계획 시스템과 in vivo dosimetry system 을 이용하여 측정한 직장 선량 비교)

  • Chung, Eun-Ji;Lee, Sang-Hoon
    • Radiation Oncology Journal
    • /
    • v.20 no.4
    • /
    • pp.396-404
    • /
    • 2002
  • Purpose : Many papers support a correlation between rectal complications and rectal doses in uterine cervical cancer patients treated with radical radiotherapy. In vivo dosimetry in the rectum following the ICRU report 38 contributes to the quality assurance in HDR brachytherapy, especially in minimizing side effects. This study compares the rectal doses calculated in the radiation treatment planning system to that measured with a silicon diode the in vivo dosimetry system. Methods : Nine patients, with a uterine cervical carcinoma, treated with Iridium-192 high dose rate brachytherapy between June 2001 and Feb. 2002, were retrospectively analysed. Six to eight-fractions of high dose rate (HDR)-intracavitary radiotherapy (ICR) were delivered two times per week, with a total dose of $28\~32\;Gy$ to point A. In 44 applications, to the 9 patients, the measured rectal doses were analyzed and compared with the calculated rectal doses using the radiation treatment planning system. Using graphic approximation methods, in conjunction with localization radiographs, the expected dose values at the detector points of an intrarectal semiconductor dosimeter, were calculated. Results : There were significant differences between the calculated rectal doses, based on the simulation radiographs, and the calculated rectal doses, based on the radiographs in each fraction of the HDR ICR. Also, there were significant differences between the calculated and measured rectal doses based on the in-vivo diode dosimetry system. The rectal reference point on the anteroposterior line drawn through the lower end of the uterine sources, according to ICRU 38 report, received the maximum rectal doses in only 2 out of the nine patients $(22.2\%)$. Conclusion : In HDR ICR planning for conical cancer, optimization of the dose to the rectum by the computer-assisted planning system, using radiographs in simulation, is improper. This study showed that in vivo rectal dosimetry, using a diode detector during the HDR ICR, could have a useful role in quality control for HDR brachytherapy in cervical carcinomas. The importance of individual dosimeters for each HDR ICR is clear. In some departments that do not have the in vivo dosimetry system, the radiation oncologist has to find, from lateral fluoroscopic findings, the location of the rectal marker before each fractionated HDR brachytherapy, which is a necessary and important step of HDR brachytherapy for cervical cancer.

Is $^{99m}Tc$-MDP Mammoscintigraphy Useful in Patients with Breast Mass Lesions? ($^{99m}Tc$-MDP 유방 스캔은 유방 종괴의 감별진단에 임상적인 유용성이 있는가?)

  • Park, Seok-Gun;Lee, Yeon-Hee;Rhyu, Jin-Woo;You, Sun-Mee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.2
    • /
    • pp.151-160
    • /
    • 1998
  • Purpose: Piccolo et al. advocated the usefulness of $^{99m}Tc$-MDP breast scan in differential diagnosis of breast mass with high accuracy. But there are little or no follow-up studies about it as we know. We studied $^{99m}Tc$-MDP uptake pattern and lesion/background ratio in patients complaining palpable breast lesions to evaluate the clinical usefulness of $^{99m}Tc$-MDP scan. Materials and Methods: Total 34 patients were studied with physical examination, mammo-gram and $^{99m}Tc$-MDP scan prospectively. Anteroposterior and both lateral view of breast were obtained 5 minutes after iv injection of 740 MBq $^{99m}Tc$-MDP. Breast uptake pattern of $^{99m}Tc$-MDP was analyzed by a grade system: 0=no uptake, grade 1=bilateral diffuse uptake, grade 2=asymmetric faint uptake, grade 3=focal hot uptake. 20 cases were pathologically confirmed by excision biopsy or aspiration biopsy. 14 cases were normal in physical examination and mammogram. Results: Pathologic results showed 7 carcinomas, 6 benign solid tumors, and 7 fibrocystic changes. Grade 3 pattern of $^{99m}Tc$-MDP uptake was noted in 4/7 carcinomas, 3/6 benign solid tumors, and 1/7 fibrocystic changes. Grade 2 pattern was 217, 0/7, 3/7 respectively. The average L/B ratio was 1.66 in carcinomas, 1.68 in benign solid masses, 1.20 in fibrocystic diseases, 1.05 in normal patients. L/B ratio was higher in carcinoma and benign mass groups than in fibrocystic change and normal control groups(p=0.005). But there was no statistical difference between L/B ratio of malignant mass group and benign mass group. Conclusion: $^{99m}Tc$-MDP scan is not suitable to routine clinical use for breast mass diagnosis. It might be used in limited conditions when whole body bone scan is planned.

  • PDF

A Study on the Dose Assessment Methodology Using the Probabilistic Characteristics of TL Element Response (확률분포 특성을 이용한 열형광선량계의 선량평가방법에 관한 연구)

  • Cho, Dae-Hyung;Oh, Jang-Jin;Han, Seung-Jae;Na, Seong-Ho;Hwang, Won-Guk;Lee, Won-Keun
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.3
    • /
    • pp.123-138
    • /
    • 1998
  • Characteristics of element responses of Panasonic UD802 personnel dosimeters in the X, ${\beta}$, ${\gamma}$, ${\gamma}/X$, ${\gamma}/{\beta}$ and ${\gamma}$/neutron mixed fields were assessed. A dose-response algorithm has been developed to decide the high probability of a radiation type and energy by using the distribution in all six ratios of the multi-element TLD. To calculate the 4-element response factors and ratios between the elements of the Panasonic TLDs in the X, $\beta$, and $\gamma$ radiation fields, Panasonic’s UD802 TLDs were irradiated with KINS’s reference irradiation facility. In the photon radiation field, this study confirms that element-3 (E3) and element-4 (E4) of the Panasonic TLDs show energy dependent both in low- and intermediate-energy range, while element-1 (E1) and element-2 (E2) show little energy dependency in the entire whole range. The algorithm, which was developed in this study, was applied to the Panasonic personnel dosimetry system with UD716AGL reader and UD802 TLDs. Performance tests of the algorithm developed was conducted according to the standards and criteria recommended in the ANSI N13.11. The sum of biases and standard deviations was less than 0.232. The values of biases and standard deviations are distributed within a triangle of a lateral value of 0.3 in the ordinate and abscissa, With the above algorithm, Panasonic TLDs satisfactorily perform optimum dose assessment even under an abnormal response of the TLD elements to the energy imparted. This algorithm can be applied to a more rigorous dose assessment by distinguishing an unexpected dose from the planned dose for the most practical purposes, and is useful in conducting an effective personnel dose control program.

  • PDF

Ultrasonographic Assessment of the Ulnar Collateral Ligament in High School Male Weight Lifters (고교 남자 역도 선수의 척측 측부인대 초음파 검사)

  • Jang, Il-Woong;Kim, Se-Sik;Choi, Chang-Hyuk
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.3 no.2
    • /
    • pp.47-53
    • /
    • 2010
  • Purpose: We evaluated the efficacy of ultrasonographic examination of the medial collateral ligament injury in elbow joints in the high school male weight lifting athletes. Materials and Methods: The study group (group I) included 15 male weight lifting athletes (average age: 16.8) and the control group (group II) was demographically matched 9 male with no symptoms on their elbow. Both elbow joint was evaluated through physical examination, plain radiograph, valgus stress view and ultrasonography. Results: On plain radiograph, there was no significant differences (3.6 mm, 2.7 mm; p>0.05) for the medial articular distances between both groups. The valgus stress view revealed the significant increase in group I (right, avr. 5.86 mm and 3.52 mm, p<0.01, left, avr. 5.33 mm and 3.64 mm, p<0.01). On ultrasonography, medial joint space was increased in group I (right, avr. 4.66 mm and 3.29 mm, p<0.01, left elbow 4.28 mm and 3.38 mm, p<0.01). The lateral shifting of proximal ulna also increased in group I (right, avr. 0.73 mm and 1.43 mm, p<0.01, left, avr. 0.96 mm and 1.53 mm, p<0.05). The angular deformity were more prevalent in group I. Conclusion: The medial joint space widening and angular deformity was prevalent in male weight lifting athletes. the ultrasonographic examination was useful in evaluating the degree and incidence of the medial collateral ligament injuries.

  • PDF

RADIOLOGICAL STUDY OF THE CONDYLAR HEADS IN TEMPOROMANDIBULAR JOINT ARTHROSIS (악관절증에서의 하악과두의 방사선학적 소견)

  • You Dong Soo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.15 no.1
    • /
    • pp.13-20
    • /
    • 1985
  • The author obtained the oblique lateral trans cranial radiograms from 376 patients (114 of male, and 262 of female) with temporomandibular joint arthrosis. After tracing each film, the author analyzed the dimensional changes of the condylar heads with pain, clicking, mouth opening limitation, and masticatory difficulty respectively, which were the chief complaints of the TMJ arthrosis and compared these data with control group. The results were as follows; 1. There was a great predilection for occurrence of the TMJ arthrosis in female (262 cases) over male (114 cases). But there was no significant difference in ratio between the sexes on each symptom. In male, 60 patients (52.6%) had pain, 28 patients (24.6%) had clicking, 21 patients (18.4%) had mouth opening limitation, and 5 patients (4.4%) had masticatory difficulty. In female, 148 parients (56.5%) had pain, 57 patients (21.8%) had clicking, 47 patients (17.9%) had mouth opening limitation, and 10 patients (3.8%) had masticatory difficulty. 2. Examined controlled group, the author analyzed the dimension of W-W', 0-H, 0-A, 0-B on the right side first, and left side second. In male, the dimension of W-W' was 14.52㎜, 14.13㎜; 0-H was 13.92㎜, 13. 71㎜' 0-A was 8.91㎜, 9.0㎜ and 0-B was 8.67㎜, 8.78㎜. In female, W-W' was 13.77㎜, 13.51㎜; 0-H was 13.42㎜, 13.35㎜; 0-A was 8.92㎜, 9.01㎜; and 0-B was 8.59㎜, 8.80㎜. 3. W-W' and 0-H of the experimental group were distinctly lesser than the controlled group. Male with mouth opening limitation show the least (12.70㎜, 13.00㎜) on W-W', but both sexes with pain show the least on 0-H. There was no significant difference between experimental group with Clicking and controlled group on 0-H, 0-A, and 0-B. And also there was no difference on 0-B in patients with every symptom except masticatory difficulty. The dimensional changes of the condylar heads with those symptoms were as follows; a) In male patients, complaing of pain, W-W' of the right and left was 13.80㎜, 12.80㎜; 0-H was 13.10㎜, 12.90㎜; 0-A was 8.69㎜, 8.18㎜; 0-B was 8.33㎜, 8.42㎜. In female, W-W' was 13.01㎜, 12.90㎜; 0-H was 12.48㎜, 12.80㎜; 0-A was 8.60㎜, 8.49㎜; 0-B was 8.48㎜, 8.50㎜. b) In male patients with clicking, W-W' was 13.70㎜, 13.10㎜; 0-H was 13.90㎜, 13.10㎜; 0-A was 8.81㎜, 8.16㎜ 0-B was 8.34㎜, 8.25㎜. In female, W-W' was 13.10㎜, 13.50㎜; 0-H was 13.30㎜, 12.91㎜; 0-A was 8.95㎜, 8.49㎜; 0-B was 8.23㎜, 8.70㎜. c) In male patients with mouth opening limitation, W-W' was 12.70㎜, 13.00㎜; 0-H was 13.40㎜, 13.40㎜; 0-A was 8.37㎜, 8.48㎜; 0-B was 8.33㎜, 8.62㎜. In female, W-W' was 13.00㎜, 12.50㎜ 0-H was 12.90㎜, 13.10㎜; 0-A was 8.49㎜, 8.09㎜; 0-B was 8.77㎜, 8.01㎜. d) In male patients with masticatory difficulty, W-W' was 13.30㎜, 13.20㎜; 0-H was 13.40㎜, 12.60㎜; 0-A was 8.26㎜, 8.32㎜; 0-B was 7.80㎜, 8.20㎜. In female, W-W' was 12.30㎜, 12.00㎜; 0-H was 13.10㎜, 13.20㎜; 0-A was 8.68㎜, 7.95㎜; 0-B was 7.46㎜, 7.87㎜.

  • PDF

Germination and Growth of Oaks (Quercus serrata, Q. mongolica, Q. variabilis) Seedlings by Gradient of Light Intensity and Soil Moisture (광도와 토양수분 구배(勾配)에 따른 참나무류(Quercus Serrata, Q. mongolica, Q. variabilis)치수(稚樹)의 발아 및 성장)

  • Beon Mu-Sup
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.2 no.4
    • /
    • pp.183-189
    • /
    • 2000
  • This study was carried out to analyze ecophysiological responses for seedling of Quercus serrata, Quercus mongolica and Quercus variabilis that are the typical species of deciduous broadleaved forests in Korea. And executed experiments in the climatic control room to provide necessary information to ecological forest management and methods of natural regeneration through the analysis of seedling responses. The details of experimental analysis were growth processes of 4 months after seeding that vary with the condition of three light intensity[relative light intensity(RLI) 8%, 20%, 52%] and three soil moisture[water suction(WS) Ψ=100 hPa, Ψ=280 hPa, Ψ=330 hPa] gradient, growth factors after harvesting and the nutrition condition of leaves. The results of this study are followings: 1) Early growth was prosperous after germination for the species which have more weight of acorn. 2) The formation of lammas shoot was favourable with Q. variabilis and Q. mongolica. And the rate of the occurrence was the highest in the RLI 20%, and it was remarkably reduced in the RLI 8%. 3) As the height growth of seedling of all 3 species were greater in the RLI 20% and 8% than that of the RLI 52%, they showed strong shade tolerance. 4) The increase of light intensity promoted the diameter at root collar growth, and development of main and lateral roots with all 3 species. 5) It showed that the increase of light intensity in the experimental radiation condition raised special leaf area weight(mg/cm$^2$) and leaf area productivity(mg/cm$^2$). Consequently, these resulted in the increase of leaf thickness and total dry biomass per the unit area of leaf. 6) As the increase of light intensity, the minerals contents of leaves such as N, P and K were lowered, and the increase of soil moisture resulted in the increase of P, K, Ca and Mg.

  • PDF

A STUDY ON THE JUJEON OF AUTOMATIC CLEPSYDRA IN EARLY JOSEON DYNASTY (조선 전기 자동물시계의 주전(籌箭) 연구)

  • YUN, YONG-HYUN;KIM, SANG HYUK;MIHN, BYEONG-HEE;OH, KYONG TAEK
    • Publications of The Korean Astronomical Society
    • /
    • v.36 no.3
    • /
    • pp.65-78
    • /
    • 2021
  • Jagyeokru, an automatic striking water clock described in the Sejong Sillok (Veritable Records of King Sejong) is essentially composed of a water quantity control device and a time-signal device, with the former controlling the amount or the flow rate of water and the latter automatically informing the time based on the former. What connects these two parts is a signal generating device or a power transmission device called the 'Jujeon' system, which includes a copper rod on the float and ball-racked scheduled plates. The copper products excavated under Gongpyeong-dong in Seoul include a lot of broken plate pieces and cylinder-like devices. If some plate pieces are put together, a large square plate with circular holes located in a zigzag can be completed, and at the upper right of it is carved 'the first scheduled plate (一箭).' Cylinder-like devices generally 3.8 cm in diameter are able to release a ball, and have a ginkgo leaf-like screen fixed on the inner axis and a bird-shaped hook of which the leg fixes another axis and the beak attaches to the leaf side. The lateral view of this cylinder-like device appears like a trapezoid and mounts an iron ball. The function of releasing a ball agrees with the description of Borugak Pavilion, where Jagyeokru was installed, written by Kim Don (1385 ~ 1440). The other accounts of Borugak Pavilion's and Heumgyeonggak Pavilion's water clocks describe these copper plates and ball releasing devices as the 'Jujeon' system. According to the description of Borugak Pavilion, a square wooden column has copper plates on the left and right sides the same height as the column, and the left copper plate has 12 drilled holes to keep the time of a 12 double-hours. Meanwhile, the right plate has 25 holes which represent seasonal night 5-hours (Kyeong) and their 5-subhours (Jeom), not 12 hours. There are 11 scheduled plates for seasonal night 5-hours made with copper, which are made to be attached or detached as the season. In accordance with Nujutongui (manual for the operation of the yardstick for the clepsydra), the first scheduled plate for the night is used from the winter solstice (冬至) to 2 days after Daehan (大寒), and from 4 days before Soseol (小雪) to a day before the winter solstice. Besides the first scheduled plate, we confirm discovering a third scheduled plate and a sixth scheduled plate among the excavated copper materials based on the spacing between holes. On the other hand, the width of the scheduled plate is different for these artifacts, measured as 144 mm compared to the description of the Borugak Pavilion, which is recorded as 51 mm. From this perspective, they may be the scheduled plates for the Heumgyeonggak Ongru made in 1438 (or 1554) or for the new Fortress Pavilion installed in Changdeokgung palace completed in 1536 (the 31st year of the reign of King Jungjong) in the early Joseon dynasty. This study presents the concept of the scheduled plates described in the literature, including their new operating mechanism. In addition, a detailed model of 11 scheduled plates is designed from the records and on the excavated relics. It is expected that this study will aid in efforts to restore and reconstruct the automatic water clocks of the early Joseon dynasty.

The Outcome of Anterior Cruciate Ligament Reconstruction in Patients with Meniscal Injury (반월판 연골 손상이 동반된 환자에서 전방 십자 인대 재건술의 임상적 결과)

  • Lee Kwang Won;Park Jae Guk;Jung Yu Hun;Kim Byung Sung;Kim Ha Yong;Choy Won Sik
    • Journal of the Korean Arthroscopy Society
    • /
    • v.7 no.2
    • /
    • pp.160-168
    • /
    • 2003
  • Purpose : To analyze the anterior stability and functional results after the arthroscopic ACL reconstruction and meniscectomy based on meniscus status at the time of surgery. Materials and Methods : From October 1997 to October 2002, 78 patients (male 64 female 14) were treated by arthroscopic ACL reconstruction and meniscectomy and followed more than 12 months (range, $12\~72$ months, average: 32 months). Average age was 32 years old (range, $18\~57$ years old). We divided the patients into 4 groups; Both menisci was intact (BMI, control group), lateral meniscus removed (LMR), medial meniscus removed (MMR) and both menisci removed (BMR). Anterior passive displacement (objective stability) was estimated using KT-2000 arthrometer under the loading of 15lb,20lb and 30lb and evaluated anterior drawer test, Lachman test, range of motion, thigh circumference. Functional evaluation system of IKDC, OAK and Lysholm knee score was used. Results : Average anterior displacement under the loading of 30lb were 2.47 mm, 2.96 mm, 2.96 mm and 3.57 mm in each group(BMI, LMR, MMR, BMR) and it was statistically significant difference (p<0.05). There is no statistically significant difference in average anterior displacement under the loading of 15lb and 20lb in each group but it has showed decreasing tendency in meniscal removed groups. The mean anterior displacement was within 3 mm in 21 cases, 15 cases, 24 cases and 12 cases (total 72 cases, $94\%$) under the loading of 15lb and 20 cases, 15 cases, 24 cases and 11 cases (total 70 cases, $91\%$) under the loading 20lb of in each group and postoperative knee joint stability has showed increasing tendency (p>0.05). The mean score was 94.5, 93.2, 92.2 and 90.4 points in each group and 71 cases $(91\%)$ were more than excellent or good with a OAK score and fair results were noted 4 cases in both meniscal removed group. There were 65 cases $(83\%)$ with a Lysholm knee score more than excellent or good, and IKDC grading were more than normal or nearly normal in 74 cases $(95\%)$ except 4 cases (2 cases in MMR group and 2 cases in BMR group). Conclusion : Long-term anterior stability and functional results of a successful ACL reconstruction affected by tile status of the menisci at the time of surgery and KT-2000 arthrometer was good for estimation of objective follow up.

  • PDF