• Title/Summary/Keyword: lateral behavior

Search Result 1,420, Processing Time 0.039 seconds

An Experimental Study on the Effects of Lateral Reinforcement of High-Strength R/C Columns Subjected to Reversed Cyclic and Axial Forces (축력과 반복횡력을 받는 고강도 R/C 기둥의 횡보강근 효과에 관한 실험적 연구)

  • 한범석;이지영;안종문;이광수;신성우
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.04b
    • /
    • pp.493-498
    • /
    • 1998
  • An experimental investigation was conducted to examine the behavior of high-strength concrete R/C columns subjected to moment, shear and axial load. The test parameters of specimens were the compressive strength of concrete(f'c=250, 516, 600kg/ ㎠), space of lateral reinforcement (20, 30, 37cm) and lateral reinforcement ratio(ρs=2.1, 3.15%). Test results indicated that compressive strength of concrete and lateral reinforcement can significantly affect and alter the behavior of column under inelastic cyclic loadings. Despite of the defaults of high-strength concrete, with increased amount of lateral reinforcement ratio to core concrete and added sub-lateral reinforcement, ductility and strength of RC columns used high-strength concrete can secured.

  • PDF

The behavior characteristic of the laterally loaded pile installed in multi-layered soil (지반층 변화에 따른 수평하중을 받는 말뚝의 거동 특성)

  • Kyung, Doo-Hyun;Hong, Jung-Moo;Lee, Jun-Hwan
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.533-538
    • /
    • 2009
  • Ultimate lateral loaded pile capacity is influenced by soil conditions. Methods of calculating ultimate lateral loaded pile capacity in homogeneous soil were suggested by a lot of previous researchers.(Broms 1964, Petrasovits & Award 1972, Prasad & Chari 1999) There is only few homogeneous soil in actual condition, however, it could be not conviction that the methods from previous researchers are correct in multi-layered soil. In this study, ultimate lateral capacities were estimated from artificial multi-layered soils and were measured from lateral load test that were composed by various soil conditions. The influence of layered soil conditions were confirmed by comparing with two results.

  • PDF

Control of cambered web's lateral dynamics by a using steering guider (가이더를 이용한 Cambered Web의 사행거동 제어에 관한 연구)

  • Lee, Hyuk-Jong;Shin, Kee-Hyun
    • Proceedings of the KSME Conference
    • /
    • 2001.06b
    • /
    • pp.688-693
    • /
    • 2001
  • It is almost impossible to have a straight web for processing in the continuous process systems. The cambered web usually causes the strip walking and damage during process. It is necessary to identify the lateral dynamics of the cambered web for the precise control of lateral behavior. In this paper, a dynamic model of the lateral behavior for a cambered web is developed by introducing the concept of steering angle equivalent to moment caused by the camber. This model can be extended to include terms associated with moment, induced by roller's tilting, web slippage, and shear force, etc. Using this model, a new feed-forward controller is proposed to enable the on-line camber estimation, which is difficult to be measured directly, and the prediction of lateral deflection caused by camber. Computer simulation study shows that the proposed controller successfully eliminates the effect of camber and has better control performance than that of the existing PID controller.

  • PDF

Effect of loading rate on mechanical behavior of SRC shearwalls

  • Esaki, Fumiya;Ono, Masayuki
    • Steel and Composite Structures
    • /
    • v.1 no.2
    • /
    • pp.201-212
    • /
    • 2001
  • In order to investigate the effect of the loading rate on the mechanical behavior of SRC shearwalls, we conducted the lateral loading tests on the 1/3 scale model shearwalls whose edge columns were reinforced by H-shaped steel. The specimens were subjected to the reversed cyclic lateral load under a variable axial load. The two types of loading rate, 0.01 cm/sec for the static loading and 1 cm/sec for the dynamic loading were adopted. The failure mode in all specimens was the sliding shear of the in-filled wall panel. The edge columns did not fail in shear. The initial lateral stiffness and lateral load carrying capacity of the shearwalls subjected to the dynamic loading were about 10% larger than those subjected to the static loading. The effects of the arrangement of the H-shaped steel on the lateral load carrying capacity and the lateral load-displacement hysteresis response were not significant.

External Post-tensioning Strengthening of Composite Girder Bridge Using Lateral Distribution of Post-tensioning Force (긴장력 횡분배를 이용한 강합성형교 외부 후 긴장 보강)

  • Park, Young Hoon;Park, Yong Gul
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.6A
    • /
    • pp.587-596
    • /
    • 2009
  • This study analyzes the lateral distribution behavior of external post-tensioning force and evaluates the possibility of strengthening the servicing composite girder bridge by adopting the external post-tensioning force to the parts of the bridge girder. From the results of experiments and analyses, it is founded that the composite girder bridge can be strengthened by applying the external post-tensioning force to the parts of the bridge girder. It is also proved that bracing improve the lateral distribution behavior of post-tensioning force. The lateral distribution behavior of post-tensioning force which influenced by stiffness ratio, girder spacing and span length is changed by the bridge type and the location of tensioned girder. From the results of analyses, set up an equation which can predict the lateral distribution behavior of external post-tensioning force and evaluate the rationality.

Lateral Behavior of Abutment Piles in Full Integral Bridge During 7 Days in Response to Hydration Heat and Drying Shrinkage (수화열과 건조수축에 의한 7일간의 완전 일체식 교량 교대 말뚝기초의 횡방향 거동)

  • ;;;;Thomas A. Bolte
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.6
    • /
    • pp.127-149
    • /
    • 2003
  • The bridge tested was 3 spans 90m-long PSC beam concrete bridge with a stub-type abutment which had a skew of 60$^{\circ}$ about the axis of bridge. A cement concrete was placed at the superstructural slab of the bridge. Inclinometers and straingauges were installed at piles as well. During 7 days-curing of superstructural slab, the pile behavior in response to hydration heat and drying shrinkage of the slab was monitored. Then monitored values were compared with the horizontal movement obtained from the HACOM program and the calculated lateral behavior obtained from the nonlinear p-y curves of pile. As a result, lateral behavior of H-piles by the field measurement occurred due to the influence of hydration heat and drying shrinkage obtained during curing of superstructural concrete. The lateral displacements by hydration heat and drying shrinkage were 2.2mmand 1.4mm respectively. It was observed as well that the inflection point of lateral displacement of pile was shown at 1.3m down from footing base. It means that the horizontal movement of stub abutment did not behave as the fixed head condition of a pile but behave as a similar condition. The measured bending stress did not show the same behavior as the fixed head condition of pile but showed a similar condition. The increment of maximum bending stress obtained from the nonlinear p-y curves of pile was about 300(kgf/$\textrm{km}^2$) and was 2 times larger than measured values regardless of installation places of straingauges. Meanwhile, lateral load, maximum lateral displacement, maximum bending stress and maximum bending moment of pile showed a linear behavior as curing of superstructural concrete slab.

The analysis of lateral behavior of connected foundation for transmission tower in clay (점토지반에 근입된 모형송전철탑 연결형 기초의 수평거동분석)

  • Kyung, Doo-Hyun;Song, Won-June;Lee, Jun-Hwan
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.629-637
    • /
    • 2010
  • In this study, we analyzed lateral behavior of connected foundation for transmission tower in clay. For this study, we performed model lateral load test, measured load-displacement curve of connected foundation. For the tests, we manufactured connected foundation model that consider a change of rigidity, installed various measuring sensors for understanding of elements and general foundation behavior. From the test results, we measured load capacities using various methods, compared and analyzed these capacities.

  • PDF

Behavior and Hysteresis Characteristics of Traditional Timber Framers under Lateral Load (전통 문화재 목조 프레임의 횡하중에 대한 거동 및 이력특성)

  • 이필성
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1999.10a
    • /
    • pp.396-403
    • /
    • 1999
  • This experimental study investigates the hysterestic behavior of traditional timber frames subjected to lateral loads. Prototype frames for this study were selected from one of typical national treasures for timber structures in Korea. For simplicity roof structures and braket systems were excluded from specimens and the joint behavior of beam-to-column system were presumed to have crucial effect on their global behavior. The experimental observation showed stiffness degradation and slip after experiencing initial yield and the first cycle at a new larger displacement due to inherent gaps in traditional timber connection and gradual indentation of interfaces, The cyclic behaviors of all specimens were similar to those os modern timber frames with bolt and nail connections. Additional structural members such as an upper beam and clay-filled wall increased the initial stiffness strength and energy dissipation. It is expected that collapse of Korean traditional timber frames under lateral load is mainly caused from P-$\Delta$ effects rather than local member failure.

  • PDF

An Effects of Lateral Reinforcement of High-Strength R/C Columns Subjected to Reversed Cyclic and High-Axail Force (고축력과 반복횡력을 받는 고강도 R/C기둥의 횡보강근 효과)

  • 신성우;안종문
    • Journal of the Korea Concrete Institute
    • /
    • v.11 no.5
    • /
    • pp.3-10
    • /
    • 1999
  • Earthquake resistant R/C frame structures are generally designed to prevent the columns from plastic hinging. R/C columns under higher axial load or strong earthquake showed a brittle behavior due to the deterioration of strength and stiffness degradation. An experimental study was conducted to examine the behavior and to find the relationship between amounts of lateral reinforcements and compressive strength of ten R/C column specimens subjected to reversed cyclic lateral load and higher axial load. Test results are follows : An increase in the amount of lateral reinforcement results in a significant improvement in both ductility and energy dissipation capacities of columns. R/C columns with sub-tie provide the improved ductility capacity than those with closely spaced lateral reinforcement only. While the load resisting capacity of the high strength R/C columns is higher than the normal strength concrete columns under both an identical ratio of lateral reinforcement, however the ductility capacity of high strength R/C columns is decreased considerably. Therefore, the amounts of lateral reinforcement must be designed carefully to secure the sufficient ductility and economic design of HSC columns under higher axial load.

The behavior and capacity of lateral loaded pile characteristics in multi-layered sand (사질토 다층지반에 관입된 말뚝의 수평 거동 및 수평 지지력 특성)

  • Kyung, Doo-Hyun;Kang, Beong-Joon;Hong, Jung-Moo;Lee, Jun-Hwan
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.738-743
    • /
    • 2008
  • Ultimate lateral loaded pile capacity is influenced by soil conditions. Methods of calculating ultimate lateral loaded pile capacity in homogeneous soil were suggested by a lot of previous researchers.(Broms 1964, Petrasovits & Award 1972, Prasad & Chari 1999, Zhang et al. 2005) There is only few homogeneous soil in actual condition, however, it could be not conviction that the methods from previous researchers are correct in multi-layered soil. In this study, the variation of ultimate lateral loaded pile capacity was analyzed in the various multi-layered conditions, ultimate lateral loaded pile capacity was calculated by the methods from previous researchers. For this study, the Lateral Pile Load Tests (LPLT) were performed in calibration chamber, the soil was composed by 3 layers and each layers had a various relative density. The results of LPLT were compared with calculated results from the previous researchers.

  • PDF