• Title/Summary/Keyword: latent heat

Search Result 641, Processing Time 0.022 seconds

Heat transfer characteristics of fin and tube heat exchangers with various interrupted surface for air conditioning application (다양한 형태의 단속표면을 갖는 공조기용 핀-관 열교환기의 열전달 특성)

  • Yun, Jeom-Yeol;Lee, Gwan-Su
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.12
    • /
    • pp.3938-3948
    • /
    • 1996
  • This study is related with the experimental investigation on the heat transfer and pressure drop characteristics of the fin-and-tube heat exchangers with three different interrupted fins and a plane fin for air-conditioning application. Experiments were conducted accordingly following the appropriate development process. Geometry similitude experiment was introduced to predict the performance of fins, and prototype experiment was also performed to confirm the validity of geometry similitude experimental results. However, these experimental results were limited to the sensible heat transfer characteristics of the heat exchangers. Hence, additional experiment was performed using refrigerant to investigate the latent heat transfer characteristics. This paper presents an appropriate process for the development of a new type heat exchanger. Sensible and latent heat transfer characteristics for each fin configuration is also provided along with the optimal fin configuration.

A Numerical Simulation of Heat and Fluid Flow for Predicting the Effect of Passage Arrangement in Automotive Heat Battery (자동차용 열전지에서 유로배열 효과 예측을 위한 열유동 수치묘사)

  • Lee, K.S.;Kwon, J.W.;Baek, C.I.;Song, Y.K.;Han, C.S.;Kim, D.J.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.3 no.5
    • /
    • pp.64-73
    • /
    • 1995
  • A numerical simulation of heat and fluid flow for predicting the effect of passage arrangement in automotive heat battery has been performed. The system is assumed to be a two-dimensional laminar flow and isothermal boundary is applied to the surface of the latent heat storage vessel. In the case of ideal heat battery the flow rate into each flow passage is evenly distributed. The various models are considered in the view of pressure drop and bulk temperature. The effects on the efficiency of the heat battery are examined by varying geometrical factors such as flow passage clearance, length of a inlet and outlet tank and the length of a latent heat storage vessel. The flow clearance is a very important -factor on the efficiency of a heat battery. As the flow passage clearance becomes narrow, the flow distribution becomes uniform and the bulk temperature increases, however the pressure drop is large. Therefore, optimal flow passage clearance has to be chosen. The present work can be used in optimizing heat battery efficiency.

  • PDF

MECHANISM OF NUCLEATE BOILING HEAT TRANSFER FROM WIRES IMMERSED IN SATURATED FC-72 AND WATER (전열면적 및 유체의 종류가 핵비등 열전달에 미치는 영향과 그 원인)

  • Kim, J.H.;You, S.M.;Park, J.Y.
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.232-239
    • /
    • 2001
  • The present study is an experimental investigation of nucleate boiling heat transfer mechanism in pool boiling from wire heaters immersed in saturated FC-72 coolant and water. The vapor volume flow rate departing from a wire during nucleate boiling was determined by measuring the volume of bubbles, varying $25{\mu}m,\;75{\mu}m,\;and\;390{\mu}m$, from a wire utilizing the consecutive-photo method. The effects of the wire size on heat transfer mechanism during a nucleate boiling were investigated by measuring vapor volume flow rate and the frequency of bubbles departing from a wire immersed in saturated FC-72. One wire diameter of $390{\mu}m$ was selected and tested in saturated water to investigate the fluid effect on the nucleate boiling heat transfer mechanism. Results of the study showed that an increase in nucleate boiling heat transfer coefficients with reductions in wire diameter was related to the decreased latent heat contribution. The latent heat contribution of boiling heat transfer for the water test was found to be higher than that of FC-72. The frequency of departing bubbles was correlated as a function of bubble diameters.

  • PDF

Heat transfer characteristics of Triple-Tube Type Latent Heat Storage Tank (3중관 튜브형 잠열 축열조에서의 열전달 특성 연구)

  • Lee, W.K.;Han, G.Y.;Kang, Y.H.
    • Journal of the Korean Solar Energy Society
    • /
    • v.21 no.1
    • /
    • pp.71-82
    • /
    • 2001
  • The heat transfer experiment in a latent heat storage tank as a solar energy storage system for the hot water supply was carried out. The latent heat storage tank was consisted of triple - tube type ; Outer shell for hot water from solar collector, PCM storage vessel in the middle of the tank and inside tube for hot water recovery. The heat storage tank has the dimension of 60 cm long and 34 cm outside diameter. Paraffin wax(m.p = 55.4C) and sodium acetate trihydrate(m.p = 58 C) were employed as the PCM this study. Experimental variables were inlet temperature and flow rate of the hot water for heat storage stage and cold water for heat recovery stage. Temperature profiles, heat transfer coefficient and the efficiency of heat storage$(Q/Q_{max})$ and heat recovery $(Q/Q_{max})$ were determined for the paraffin wax and inorganic salt respectively.

  • PDF

Heat transfer characteristics of Immersed Coil Type Latent Heat Storage Tank (내부코일형 잠열 축열조에서의 열전달 특성 연구)

  • Lee, W.K.;Han, G.Y.;Kang, Y.H.
    • Journal of the Korean Solar Energy Society
    • /
    • v.21 no.1
    • /
    • pp.83-91
    • /
    • 2001
  • The heat transfer experiment in a pilot scale latent heat storage tank as a solar energy storage system for the hot water supply was carried out. The latent heat storage tank was consisted of three parts; Outer shell for hot water from solar collector, PCM storage vessel in the middle of the tank and immersed coil in the PCM vessel for hot water recovery. The heat storage tank has the dimension of 115 cm in height and 32 cm outside diameter. Paraffin wax (m.p = 55.4C) and sodium acetate trihydrate (m.p = 58 C) were employed as the PCM this study. Experimental variables were inlet temperature and flow rate of the hot water for heat storage stage and cold water for heat recovery stage. Temperature profiles, heat transfer coefficient and the efficiency of heat storage $(Q/Q_{max})$ and heat recovery $(Q/Q_{max})$ were determined for the paraffin wax and inorganic salt respectively.

  • PDF

Performance Analysis of Sensible and Latent Energy Recovery System for Thermally Controlled Facilities (향온시설물에 대한 현열 및 잠열 에너지 회수시스템의 성능해석)

  • 박병규;김무근;김근오
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.12
    • /
    • pp.1057-1065
    • /
    • 2000
  • A sizing of sensible and latent energy recovery system with condensing heat exchanger is important to the design of a thermally controlled facilities. The transient system simulation program TRNSYS 14.2/IISiBat has been used to evaluate the energy consumptions of a thermally controlled facilities which consist of boiler, chiller and condensing heat exchanger, The boiler and chiller are selected based on the annual peak loads and controlled to maintain the setting temperature of $14~17^{\circ}C$. Simulation shows that the amount of sensible and latent energy recovered by heat exchanger is almost 20% of total heating load.

  • PDF

Latent Heat Storage Characteristics of Some Paraffins(CnH2n+2) for Thermal Environment Control of Greenhouse (그린하우스 열환경 조절을 위한 파라핀계 화합물(CnH2n+2)의 잠열 축열 특성)

  • 송현갑;유영선
    • Journal of Biosystems Engineering
    • /
    • v.21 no.1
    • /
    • pp.84-93
    • /
    • 1996
  • Several paraffins(CnH2n +2) can be used as the thermal energy storage medium because of their large amount of latent heat and their flexibility of phase change temperature. But they have not been used in the thermal energy storage system because their long term stability have not been verified. Paraffins(CnH2n+2) which the values of n are 23, 24, 26 and 28 were selected for this experimental research. And this research was peformed to apply them to the practical systems. The results were summarized as follows. (1) The increase of phase change cycles had no effect on their phase change temperatures. (2) According as the values of n increased from 23 to 28, the specific heats of paraffins(CnH2n+2) increased, and were in the range of 0.47 0.75 ㎉/$kg^circ C$. (3) Thermal conductivities of them were in the range of 0.14 0.17 W/$m^circ C$. and specific gravities of them were in the range of 765800 kg/m3. (4) The density of paraffins was in the range of 765 800 kg/$m^circ C$ , and the density of solid phase was larger than that of liquid phase. (5) When the number of phase change cycles was 1, 500 cycles, the latent heat of paraffins was 90% of the initial value.

  • PDF

Green-infra Strategies for Mitigating Urban Heat Island (도시열섬현상완화를 위한 그린인프라 전략)

  • Park, Chae-Yeon;Lee, Dong-Kun;Kwon, Eu-gene;Her, Min-ju
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.20 no.5
    • /
    • pp.67-81
    • /
    • 2017
  • Because of lack of accurate understanding of the mechanism of urban heat island (UHI) phenomenon and lack of scientific discussion, it is hard to come up with effective measures to mitigate UHI phenomenon. This study systematically described the UHI and suggested the solutions using green-infrastructure (green-infra). The factors that control UHI are very diverse: radiant heat flux, latent heat flux, storage heat flux, and artificial heat flux, and the air temperature is formed by the combination effect of radiation, conduction and convection. Green-infra strategies can improve thermal environment by reducing radiant heat flux (the albedo effect, the shade effect), increasing latent heat flux (the evapotranspiration effect), and creating a wind path (cooling air flow). As a result of measurement, green-infra could reduce radiant heat flux as $270W/m^2$ due to shadow effect and produce $170W/m^2$ latent heat flux due to evaporation. Finally, green-infra can be applied differently on the macro(urban) scale and micro scale, therefore, we should plan and design green-infra after the target objects of structures are set.

An Experimental Study on the Heat Dissipation Characteristics of the Natural Convection Type Radiator by using the PCMs (PCM물질을 적용한 자연대류형 방열기의 방열특성에 관한 실험적 연구)

  • Sung, Dae-Hoon;Kim, Min-Jun;Kim, Joung-Ha;Yun, Jae-Ho;Kim, Woo-Seung;Peck, Jong-Hyeon
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1155-1160
    • /
    • 2008
  • In the present study investigated the heat dissipation characteristics of the natural convection type radiator by using the latent heat from a solid-liquid PCM(Phase Change Material). Total radiator volume size is $423{\times}295{\times}83\;mm$ and PCM tank size is $398{\times}270{\times}26\;mm$. The objective was elapsed time lower than maximum operating temperature. Experimental condition, in order to study the effects of the phase-change phenomenon, carried out the various mass flow rate, input electric power, and heat of fusion temperature of two type PCMs. For the above experimental conditions, the cooling performance by using the latent heat showed that heat absorption rate performs for about 3 hours from using PCM $38^{\circ}C$. However, cooling performance by using PCM $50^{\circ}C$ showed higher than surface temperature of heater block because of heat of fusion.

  • PDF

APPLICATION OF REMOTE SENSING IMAGERY ON THE ESTIMATE OF EVAPOTRANSPIRATION OVER PADDY FIELD

  • Chang, Tzu-Yin;Chien, Tzu-Chieh;Liou, Yuei-An
    • Proceedings of the KSRS Conference
    • /
    • v.2
    • /
    • pp.752-755
    • /
    • 2006
  • Evaportranspiration is an important factor in hydrology cycle. Traditionally, it is measured by using basin or empirical formula with meteorology data, while it does not represent the evaportranspiration over a regional area. With the advent of improved remote sensing technology, it becomes a surface parameter of research interest in the field of remote sensing. Airborne and satellite imagery are utilized in this study. The high resolution airborne images include visible, near infrared, and thermal infrared bands and the satellite images are acquired by MODIS. Surface heat fluxes such as latent heat flux and sensible heat flux are estimate by using airborne and satellite images with surface meteorological measurements. We develop a new method to estimate the evaportranspiration over the rice paddy. The surface heat fluxes are initialized with a surface energy balance concept and iterated for convergent solution with atmospheric correct functions associated with aerodynamic resistance of heat transport. Furthermore, we redistribute the total net energy into sensible heat and latent heat fluxes. The result reveals that radiation and evaporation controlled extremes can be properly decided with both airborne and satellite images. The correlation coefficient of latent heat flux and sensible heat flux with corresponding in situ observations are 0.66 and 0.76, respectively. The relative root mean squared errors (RMSEs) for latent heat flux and sensible heat flux are 97.81 $(W/m^2)$ and 124.33 $(W/m^2)$, respectively. It is also shown that the newly developed retrieval scheme performs well when it is tested by using MODIS date.

  • PDF