• Title/Summary/Keyword: laser treatment

Search Result 1,157, Processing Time 0.022 seconds

Case Study on Treating Acne Scar Using Hani-maehwa Laser (하니매화레이저를 이용한 여드름 흉터 치료 1례)

  • Lee, Deuk-Joo;Kim, Chul-Yun;Kwon, Kang;Seo, Hyung-Sik
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.29 no.2
    • /
    • pp.106-111
    • /
    • 2016
  • Objective : The aim of this study is to report the effect of Hani-maehwa laser(fractional mode) treatment on acne scar. Methods : The patient with atrophic facial acne scars was treated with 5 sessions of laser therapy at 4-week intervals. The therapeutic response to treatment was assessed at 3 months after last laser session. The treatment effect was evaluated by standardized photography, anti aging, skin brightness and flatness. That was measured by micro fluorescence measurement camera(ECO SKIN, Cuvitz Inc.) in 16(left zygoma) and 26(right zygoma) spot. And side effects were also checked. Results : Atrophic facial acne scars have improved markedly. Anti aging, skin brightness and flatness were improved. Especially anti aging and flatness were noticeably improved. Adverse effects were not reported.Conclusions : Korean medicine cautery method applies to high level laser(CO2 Hani-maehwa laser). These are different designs but same principle. It can be considered that laser therapy is effective method for treating acne scars.

Effects of the low power He-Ne IR laser on the healing of the peripheral neuropathy in diabetic rats (저에너지 He-Ne IR laser가 당뇨쥐 말초 신경병증 치유에 미치는 영향)

  • Rho, Min-Hee;Lee, Hyun-Ok;Baek, Su-Jeong;Lee, Mi-Ae
    • Journal of Korean Physical Therapy Science
    • /
    • v.7 no.2
    • /
    • pp.559-565
    • /
    • 2000
  • This studies were to investigate the effects of low power Helium-Neon Infra-Red (He-Ne IR) laser on the healing of the peripheral neuropathy in diabetic rats. The twenty one Spraque-Dewley adult male rats were assigned to the 3 groups: the control group (7), the diabetic group (7) and the laser group (7). The diabetic group was induced with a single intravenous injection of 50mg/kg body weight streptozotocin dissolved to 0.01mol/L citrate buffer, pH 4.5. The experimental laser group was irradiated low power He-Ne IR laser for 5 minutes every day during 21 days to the diabetic group. The results were as follows: For on and two weeks with laser treatment, there were significantly increased the terminal latencies of the laser treatment group than those of diabetic group, but that was significantly decreased to be similar to the control group on the laser treatment group for three weeks. The change of the amplitude on the laser treatment groups for three weeks was significantly increased to be similar to normal group than that of the diabetic group. As the result, we thank that there were activately effected of lower power He-Ne IR laser on the heeling of the peripheral neurophathy in diabetic rats.

  • PDF

An Analysis of the Correlation between He-Ne Laser Therapy in Literature and Clinical Application (He-Ne 레이저에 대한 문헌과 이를 근거로 한 임상 활용 예의 비교 고찰)

  • Youn, In-Hwan;Kim, Nam-Kwen
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.19 no.2
    • /
    • pp.192-201
    • /
    • 2006
  • Objectives : Recently, He-Ne laser has been used for clinical purpose. We study the medical basis of He-Ne laser therapy and We make a proposal concerning the clinical application of using He-Ne laser in Medicine. Methods : We have selected data related to He-Ne laser therapy and study how to use He-Ne laser in clinic. Results : In biology, He-Ne laser therapy has been effects of an improve in skin regeneration an improve in peripheral and central nerve regeneration an improve in muscle regeneration, an anti-inflammation an alleviation of pain and a bone repair. In oriental medicine, He-Ne laser has been used to laser acupuncture and laser oriental physical treatment. In clinic, He-Ne laser have been used to care several parts like as facial palsy, facial spasm, trigeminal neuropathy, rhinitis and tinnitus. Recently, there is argument that He-Ne laser therapy is suitable to medical insurance. Conclusions : Laser therapy in oriental medicine is widespread and We can apply He-Ne laser to facial palsy, facial spasm, trigeminal neuropathy, rhinitis, tinnitus by using laser acupuncture or laser oriental physical treatment. Till now the whole mechanisms are not fully understood, so we hope to study these mechanisms actively and make suitable to medical insurance device in the near future.

  • PDF

Effects of resolution of inflammation for low-power $CO_2$ laser treatment on gingivitis patients (치은염 환자에서 저출력 이산화탄소 레이저의 염증완화 효과에 관한 연구)

  • Song, Hyun-Jong;Kim, Byung-Ock;Jang, Hyun-Seon
    • Journal of Periodontal and Implant Science
    • /
    • v.38 no.4
    • /
    • pp.657-668
    • /
    • 2008
  • Purpose: In this study, we compared low-power $CO_2$ laser treatment to ultrasonic scaling, which is generally approved as a power-driven mechanical instrumentation, and evaluated both of these treatments regarding their clinical effectiveness and change in the volume of in GCF. Material and methods: 20 patients who had gingivitis were selected. all of patients has no systemic problems. Randomly selected, one quadrant received ultrasonic scaling only, another quadrant received ultrasonic scaling and $CO_2$ laser irradiation, the other quadrant received $CO_2$ laser irradiation only. Clinical parameters measured at baseline, 1 weeks, 2weeks, 4weeks and 8weeks. Result: Pocket probing depth and clinical attachment level were not changed during study period. Gingival index of all group were improved after treatment. At 1 weeks after treatment, Gingival index of ultrasonic scaling group was only significantly different compared to control group. At 2 weeks after treatment, gingival index of all experimental group were significantly different compared to control group. At 4 and 8 weeks after treatment, gingival index of all group were increased, but experimental group were lower than control group. Sulcus bleeding index was similar to the results of gingival index. At 1 weeks after treatment, all experimental group were significantly different compared to control group and it maintained during study. At 2 weeks after treatment, sulcus bleeding index of all group were lowest during study. Gingival crevicular fluid were measured with $Periotron^{(R)}$ 8000($Oraflow^{(R)}$, Inc. USA). At baseline, all group were showed moderately severe condition. At 1 week after treatment, laser treatment only group was reduced quantity of gingival crevicular fluid mostly, and all group were reduced quantity of gingival crevicular fluid. At 2 weeks after treatment, all group were health state. At 4 and 8 weeks after treatment, all group were showed recurrent of inflammation, and control group was the most significantly increased. Conclusion: This study showed that the effects of $CO_2$ laser treatment were similar to conventional ultrasonic scaling and this result remained longer than plaque control only. These results suggest possibility of $CO_2$ laser treatment for altered periodontal therapy.

Development of the Diode Laser Heat Treatment Robot System Based on OLP Simulator (OLP 시뮬레이터 기반의 다이오드 레이저 열처리 로봇시스템 개발)

  • Park, Kee-Jin;Yoon, Sung-Ho
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.14 no.5
    • /
    • pp.8-14
    • /
    • 2015
  • Heat treatment for car body molds is mainly a manual process performed by a worker. The performance of this process is affected by workers' skill level, and has limitation in maintaining uniform product quality. In this study, we developed a diode laser heat treatment robot system that implements an OLP type simulator to overcome the limitation of manual process, and to improve and stabilize the quality level. In addition, we verified the efficiency of the robot system and mechanism stability from the early stage through design verification and simulated analysis in the development stage. In addition, we carried out a field test to study the way to establish optimized D/B for diode laser heat treatment criteria for car body molds, such as heat treatment speed, interval, etc. via site experiment.

Characteristics of Metal Surface Heat Treatment by Diode Laser (다이오드 레이저를 이용한 금속 표면 열처리 특성)

  • Choi, Seong-Dae;Cheong, Seon-Hwan;Kim, Gi-Man;Yang, Seung-Cheol;Kim, Jam-Gyu
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.6 no.3
    • /
    • pp.16-23
    • /
    • 2007
  • An experimental investigation with diode laser system was carried out to study the effect of surface heat treatment on the die materials(SM45C, SKD11, SK3). The surface heat treatment characteristics of the laser beam are evaluated using hardness tests, optical microscopy, X-ray diffraction and energy dispersive X-ray spectroscopy(EDS). Results indicated that the beam size, focal length, feed rates are changed surface hardened characteristics. SM45C is higher hardness than other materials and composed to martensite grain at hardened zone, whereas other materials(SKD11, SK3)are low hardness than expected and composed to austenite and allayed martensite at hardened zone. The intensive X-ray diffraction patterns of (110)-(200)-(211) is detected hardened surface and the hardened surface distributed plenty of carbon density than metal zone.

  • PDF

THERMOMECHANICAL STUDY OF LASER TREATED NiTi DENTAL ARCH WIRE

  • Kim, Young-Kon;Park, Joon-B.;Lakes, R.S.;Andreasen, G.F.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1989 no.05
    • /
    • pp.9-12
    • /
    • 1989
  • A preliminary study has been conducted to demonstrate the effect of laser heat treatment on Ni Ti alloy dental arch wires ($0.016"\;{\times}\;0.022"$ and $0.018"\;{\times}\;0.026"$, rectangular shape). Changes in mechanical and thermal properties and surface morphologies are investigated by using optical and scanning electron microscope (SEM), energy dispersive x-ray microprobe analysis(EDX), differential scanning calorimeter (DSC), and micro hardness tester. The results indicate that the laser can affect the thermal equilibrium state of the localized surface. Titanium rich surface film is formed by the laser treatment. The surface film and rapidly resolidified underlying structures show better chemical resistance than the matrix material. Phase transition temperatures which are related to shape recovery temperatures are changed after laser treatment. Hardness of resolidified area and heat affected zone are lower than before treatment.

  • PDF

Successful Treatment of Post-operative Keloid with Combined Cryotherapy and Ablative Fractional CO2 Laser

  • Kim, Jihee;Lee, Young In;Lee, Ju Hee;Oh, Sang Ho;Lee, Sang Eun;Kim, Young Koo
    • Medical Lasers
    • /
    • v.9 no.1
    • /
    • pp.58-61
    • /
    • 2020
  • Keloids are pathologic fibroproliferative conditions characterized by excessive collagen deposition during wound healing. The pathogenesis of keloids is not fully understood, and current treatment options show variable results. In this case report, the patient developed a keloid after bilateral total thyroidectomy, and was treated with a combination approach using fractional ablative laser systems along with cryotherapy and triamcinolone injection. After seven monthly sessions of combination treatment, the patient presented marked improvement of the scar texture and symptoms. Furthermore, there was no recurrence for up to 2 years. We propose this combination as a safe and effective treatment option for keloid patients.

Characterization of Surface treatment for Mold materials using optical system of laser heat treatment (레이저 열처리 광학계를 이용한 금형소재의 표면 열처리 특성)

  • Shin, Ho-Jun;Yoo, Young-Tae;Shin, Hyung-Heon;Ro, Kyoung-Bo
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1542-1547
    • /
    • 2007
  • Laser surface treatment technologies have been used to improve characteristics of wear and to enhance the fatigue resistance for mold parts. The optical lens with the elliptical profile is designed to obtain a wide surface hardening area with a uniform hardness. The objective of this research work is to investigate the influence of the process parameters, such as power of laser and defocused spot position, on the characteristics of laser surface treatment for the case of SKD61 steel and SCM4 steel. From the results of the experiments, it has been shown that the maximum average hardness is approximatly 700${\sim}$780 Hv when the power, focal position and the travel of laser are 1,095 W, 0mm and 0.3 m/min, respectively. In samples treated with lower scanning speeds, some small carbide particles appear in the interdendritic regions. This region contains fine martensite and carbide in proportions which depend on the local thermal cycle.

  • PDF

A Study on the Surface Treatment of Dental Implant using a Fiber Laser (파이버 레이저를 이용한 치과용 임플란트 표면처리에 관한 연구)

  • Shin, Ho-Jun;Yang, Yun-Seok;Hwang, Chan-Youn;Yoo, Young-Tae
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.8
    • /
    • pp.915-928
    • /
    • 2011
  • Titanium for dental implant application has the superior properties of biocompatibility, specific strength, and corrosion resistance. However, it is extremely difficult to find a suitable surface treatment method for sufficient osseointegration with biological tissue/bone cell and implant surface. Surface treatment technology using laser has been researched as the way to increase surface area of implant. In this study, to develop the surface treatment process with improved adhesion between implant and bone cell at the same time for superior biocompatibility, pulsed laser beam was overlapped continuously for scribed surface morphology and determination of friction coefficient. As the results, surface area and friction coefficient was increased over 2 times by the comparison with sand blasting, which is used for the conventional method. In this time, the optimal condition for laser beam power and beam irradiation speed was 13 watt and 50 mm/sec, respectively.