• 제목/요약/키워드: laser measurement

검색결과 2,033건 처리시간 0.036초

DEVELOPMENT OF 3D STRUCTURE MEASUREMENT SYSTEM USING LASER SCANNING DATA AND CCD SENSOR

  • Honma Kazuyuki;KAllWARA Koji;HONDA Yoshiaki
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2005년도 Proceedings of ISRS 2005
    • /
    • pp.76-78
    • /
    • 2005
  • When the data from the artificial satellite is analyzed, recent years it is perceived to vegetation index using BRF(Bidirectional Reflectance Factor) of the observation target. To make the BRF models, it is important to measure the 3D structure of the observation target actually. In this study, it is proposed to the observation technique by using laser scanning data. Also, our team has been operating the radio controlled helicopter which can fly over the tall forest canopy and it can be equipped the measurement system.

  • PDF

펄스형 eye-safe 레이저를 이용한 거리측정 (Distance measurement using pulsed eye-safe laser)

  • 유병헌;조성학;장원석;김재구;황경현;이동주
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.106-109
    • /
    • 2004
  • In this project, we have developed the eye-safe LRF system of 1.54 ${\mu}{\textrm}{m}$ wavelength using OPO. The maximum measured distance was 3.7km in outdoor experiment. We used Nd:YAG (1064nm) as a laser medium. It was applied BBO to construct the system. We also developed a time-counter for the range finder using a method of TOF (time of flight). The counter-clock used at the time counter was 320MHz making resolution within $\pm$1m. Start and stop signals were detected by two channel systems using PIN and APD. The LRF's repetition rate was 4 times per minute. The energy was measured to be over 9mJ. And, pulse-duration was 23ns. Resolution was $\pm$2m at the distance measurement using a target.

  • PDF

원통연삭가공시 레이저 빔을 이용한 금속 표면거칠기의 인프로세스 측정에 환한 연구 (A Study on the In-process Measurement of Metallic Surface Roughness in Cylindrical Grinding by Laser Beam)

  • 김희남;윤여권;이주상;김대욱
    • 한국안전학회지
    • /
    • 제9권3호
    • /
    • pp.41-52
    • /
    • 1994
  • This paper deal with the design of noncontact In-process measurement system which measures the surface roughness during cylindrical grinding. The measuring system is extremely simple and the apparatus proposed is composed of a laser unit, photodetector and optical system. The experimental performance of the apparatus is satisfactory and good results are expected in the actual use. During operation, the surface of a workpiece Is continuously scanned by a laser beam. The experimental results show that the presence of chattering, loading and glazing can be detected sensitively along both circumferential and feed directions and the surface roughness value is obtained from the reading along the feed direction.

  • PDF

영상 측정 데이터를 이용한 위치보정 레이저 가공시스템 개발 (Development of Auto Positioning Laser System by using Image Measurement Data)

  • 표창률
    • 한국기계가공학회지
    • /
    • 제12권3호
    • /
    • pp.36-40
    • /
    • 2013
  • Recently, electronic equipments become smaller, more functional, and more complex than before. As these trends, MLC(multi-layer ceramic) circuit has been emerged to a promising technology in semiconductor inspection industry. Especially, multi-layer ceramic which is consisted of many fine-pitch multi-hole is used to produce a semiconductor inspection unit. The hole is processed by UV laser. But, working conditions are changed all the time. Therefore real time measurement of fine-pitch multi-hole is very important method for ensuring performance. In this paper we found the best method for illuminating and auto focusing. And, we verified our equipment.

레이저 섬광법에 의한 열확산계수 측정시 적외검출소자에서 실시간 온도보정이 미치는 영향 (Effects of the in-process calibration from IR detector for thermal diffusivity measurement by laser flash method)

  • 이원식;배신철
    • 설비공학논문집
    • /
    • 제10권6호
    • /
    • pp.795-802
    • /
    • 1998
  • For measuring the thermal diffusivity by laser flash method, raw data have to be calibrated using temperature data. We have developed in-process calibration method and polynomial calibration in which thermal diffusivity can be calibrated during measuring, This method is different from existing temperature pre-process calibration method and exponential calibration having various source of error. Using this new calibration method, measurement accuracy was improved about 1∼2% compare to the value by the existing method. We also studied more accurate fitting curve as in Figure 4 was shown the result of measuring output characteristics of IR radiometer with temperature. As illustrated in data, in-process calibration method and polynomial calibration equation is proper than pre-process calibration method and exponential calibration.

  • PDF

실시간 전자거리인식을 위한 3차원거리계측 알고리즘

  • 김종만;신동용;이혜정;김형석
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 춘계학술대회 논문집
    • /
    • pp.5-5
    • /
    • 2010
  • The depth of the object pointed by the laser beam is computed depending on the pixel position on the CCD There involved several number of internal and external parameters such as inter-pixel distance, focal length, position and orientation of the system components in the depth measurement error. In this paper, it is shown through the error sensitivity analysis of the parameters that the most important parameters in the sense of error sources are the angle of the laser beam and the inter pixel distance. Also, the calibration technique to minimize their effect for the depth computation is proposed.

  • PDF

Measurement of Vibration Using a 3-facet Mirror

  • Park, Won-Shik;Cho, Hyung-Suck;Byun, Yong-Kyu
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.131.5-131
    • /
    • 2001
  • A new measurement method to measure vibrational motions of objects is presented. The original principle is similar to the previous work that utilized a 3-facet mirror to obtain three dimensional positions and orientations of rigid bodies. While the previous work was presented for only stationary objects, in this paper, we newly investigate the feasibility of this method for dynamic applications. The 3-facet mirror that looks like a triangular pyramid having an equilateral cross-sectional shape. The mirror has three lateral reflective surfaces inclined 45 degrees to its bottom surface, and its mounted on the object whose motion is to be measured, As optical components, a He-Ne laser source and three position-sensitive detectors(PSD) are used. The laser beam is emitted from the He-Ne laser source located at the upright position and vertically incident to the top of the 3-facet ...

  • PDF

CCD/LSB 방식의 형상측정시스템의 정밀도 향상 방법 (Precision enhancement for a CCD/LSB type shape measuring system)

  • 유주상;정규원
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2001년도 춘계학술대회 논문집(한국공작기계학회)
    • /
    • pp.137-142
    • /
    • 2001
  • Since recent production system becomes that of the small quantity, large volume with high quality production, accurate and high speed inspection system is required. In such situation, noncontact 3D measurement system which utilized CCD cameras is useful technique in terms of system cost, speed of data acquisition, measuring accuracy and application. However, it has low accuracy compared with contact 3D measurement system because of the camera distortion, non uniformity of laser distribution and so on. For those reasons, in this paper precision enhancement method is studied considering radial camera distortion, and laser distribution. A distortion correction method is applied even to the standard lens. The laser slit beam trajectory is determined by 3 method: based of the Gaussian function signal approximation, the median method, the center of gravity method and the peak point of the Gaussian function method.

  • PDF

Compact and versatile range-finding speedometer with wide dynamic range

  • Shinohara, Shigenobu;Pan, Derong;Kosaka, Nozomu;Ikeda, Hiroaki;Yoshida, Hirofumi;Sumi, Masao
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1995년도 Proceedings of the Korea Automation Control Conference, 10th (KACC); Seoul, Korea; 23-25 Oct. 1995
    • /
    • pp.158-161
    • /
    • 1995
  • A new laser diode range-finding speedometer is proposed, which is modulated by a pair of positive and negative triangular pulse current superimposed on a dc current. Since a target velocity is directly obtained form a pure Doppler beat frequency measured during the non-modulation period, the new sensor is free from the difficulties due to the critical velocity encountered in the previous sensor. Furthermore, the different amplitude of the two triangular pluses are so adjusted that the measurable range using only one laser head is greatly expanded to 10cm through 150cm, which is about two times that of the previous sensor. The measurement accuracy for velocity of .+-.6mm/s through .+-.20mm/s and for range is about 1%, and 2%, respectively. Because the new sensor can be operated automatically using a microcomputer, it will be useful for application of a 3-D range image measurement of a slowly moving object.

  • PDF

샤냑간섭계를 이용한 레이져빔의 Spatial Coherence Function 측정 (Measurement of Spatial Coherence Function of laser beam by using a Sagnac Interferometer)

  • Lee, Chang-Hyouck;Kang, Yoon-Shik;Sung, Yu-Gene;Noh, Jae-Woo
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2007년도 하계학술발표회 논문집
    • /
    • pp.111-112
    • /
    • 2007
  • The spatial coherence function of laser beam was measured by using a Sagnac interferometer and self referencing technique. For laser beam passing through a narrow slit, absolute value of measured spatial coherence function becomes more symmetric as the slit size is reduced. For diverging beams, the spatial coherence function shows fast oscillations in its real and imaginary parts. We explain this by using a Gaussian Schell-model. One can use this measurement method to study and characterize the property of light field coming out of small sample.

  • PDF