• Title/Summary/Keyword: laser measurement

Search Result 2,037, Processing Time 0.028 seconds

Elastic modulus measurement of thin films using laser generated guided ultrasonic waves (레이저 초음파 기법을 이용한 박막 탄성계수 측정)

  • Cho, Seung Hyun;Heo, Taehoon;Ji, Bonggyu;Ahn, Bongyoung;Jang, Gang-Won
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.550-554
    • /
    • 2014
  • Regarding thin films in MEMS/NEMS structures, the exact evaluation of mechanical properties is very essential to enhance the reliability of their design and manufacturing. However, such methods as a tensile test and a resonance test, general methods to measure elastic moduli, cannot be applied to thin films since its thickness is so small. This work concerns guided wave based elastic modulus measurement method. To this end, guided wave excitation and detection system using a pulsed laser and a laser interferometry has been established. Also an elastic modulus extraction algorithm from the measured guided wave signal was developed. Finally, it was applied to actual thin film structures such as Ni-Si and Al-Si multilayers. From experimental results, we confirm that the proposed method has considerable feasibility to measure elastic properties of thin films.

  • PDF

A Study on the Measurement Methodology for Soft Tissue Deformation Using Laser Extensometer (레이저 변위계를 이용한 생체 연조직의 변형 측정법에 관한 연구)

  • 최경주;홍정화;문무성;이진희
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.1085-1087
    • /
    • 2002
  • Deformation of soft tissue is known inhomogeneous and non-linear in general. In this study, we propose a measurement methodology of local/global strain during soft tissue elongation precisely using laser extensometer which has high accuracy, resolution and is possible to measure global/local strain. The mechanical tensile test are performed on tibialis cranialis, flexor hallucis longus, extensor digitorum longus of swine hindlimb. In order to measure target displacement, reflective marker is attached to detect elongation on specimen using surgical adhesive. The result of this study is to show that laser extensometer is valid to measure longitudinal elongation which is inhomogeneous and non-linear fur soft tissue.

  • PDF

An Experimental Study of Reconstruction from Laser Diffraction Measurement for Axisymmetric Sprays (레이저 회절법을 이용한 축대칭 분무 구조의 공간 분포 변환에 관한 실험적 연구)

  • 양승연;이충훈;구자예;정석호
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.8 no.1
    • /
    • pp.10-16
    • /
    • 2000
  • Spatially resolved liquid volume fractions from a set of line-of-sight laser diffraction measurements for axisymmetric sprays generated from a pintle-type gasoline injector have been tomographically reconstructed by Abel transformation, Fourier transformation and onion peeling method. Spatially resolved liquid volume fractions classified into 32 size groups were translated characteristics of SI engine fuel sprays. These data were also obtained from the phase Doppler measurements for the same sprays. The comparison between laser deffraction measurements and transformation reconstructs more reasonable spatially resolved characteristics for axisymmetric sprays as well as for asymmetric sprays.

  • PDF

Accuracy Estimation of Laser scanning Mobile Mapping System using Lynx Mobile Mapper (Lynx Mobile Mapper를 이용한 레이저스캐너 기반 차량 MMS의 정확도 평가)

  • Jeong, Tae-Jun;Yun, Hong-Sic;Hwang, Jin-Sang;Kim, Yong-Hyun;Wi, Gwang-Jae;Lee, Ha-Jun
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2010.04a
    • /
    • pp.69-71
    • /
    • 2010
  • In this paper, we focus on the accuracy estimation of laser scanning mobile mapping system using Lynx Mobile Mapper. For this, we surveyed checkpoints(181 points) in study areas. A method to estimate the accuracy of laser scanning mobile mapping system based on the measurement range, interval of control points and gps signal environments. As a result, to ensure reliable measurement results, we must be made a plan considering Measure range(60m or under) and operation. The estimation results showed the need for improving accuracy using control points about 150m interval according to environment error source.

  • PDF

Ultra High-speed 3-dimensional Profilometry Using a Laser Grating Projection System

  • Park, Yoon-Chang;Ahn, Seong-Joon;Kang, Moon-Ho;Kwon, Young-Chul;Ahn, Seung-Joon
    • Journal of the Optical Society of Korea
    • /
    • v.13 no.4
    • /
    • pp.464-467
    • /
    • 2009
  • The grating projection method with phase-shifting technique is very useful in measuring the 3-dimensional (3D) shape with high accuracy and speed. In this work, we have developed an ultra high-speed digital laser grating projection system using a high-power laser diode and a highsensitivity CMOS camera. With our system, the optical measurement required to find out the profile of a 3D object could be carried out within 2.6 ms, which is a significant ($\sim$10 times) improvement compared with those of the previous studies.

A Fiber Laser Spectrometer Demodulation of Fiber Bragg Grating Sensors for Measurement Linearity Enhancement

  • Kim, Hyunjin;Song, Minho
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.4
    • /
    • pp.312-316
    • /
    • 2013
  • A novel fiber-optic sensor system is suggested in which fiber Bragg grating sensors are demodulated by a wavelength-sweeping fiber laser source and a spectrometer. The spectrometer consists of a diffraction grating and a 512-pixel photo-diode array. The reflected Bragg wavelength information is transformed into spatial intensity distribution on the photo-diode array. The peak locations linearly correspond to the Bragg wavelengths, regardless of the nonlinearities in the wavelength tuning mechanism of the fiber laser. The high power density of the fiber laser enables obtaining high signal-to-noise ratio outputs. The improved demodulation characteristics were experimentally demonstrated with a fiber Bragg grating sensor array with 5 gratings. The sensor outputs were in much more linear fashion compared with the conventional tunable band-pass filter demodulation. Also it showed advantages in signal processing, due to the high level of photo-diode array signals, over the broadband light source system, especially in measurement of fast varying dynamic physical quantities.

Improving the Capture-range Problem in Phase-diversity Phase Retrieval for Laser-wavefront Measurement Using Geometrical-optics Initial Estimates

  • Li, Li Jie;Jing, Wen Bo;Shen, Wen;Weng, Yue;Huang, Bing Kun;Feng, Xuan
    • Current Optics and Photonics
    • /
    • v.6 no.5
    • /
    • pp.473-478
    • /
    • 2022
  • To overcome the capture-range problem in phase-diversity phase retrieval (PDPR), a geometrical-optics initial-estimate method is proposed to avoid a local minimum and to improve the accuracy of laser-wavefront measurement. We calculate the low-order aberrations through the geometrical-optics model, which is based on the two spot images in the propagation path of the laser, and provide it as a starting guess for the PDPR algorithm. Simulations show that this improves the accuracy of wavefront recovery by 62.17% compared to other initial values, and the iteration time with our method is reduced by 28.96%. That is, this approach can solve the capture-range problem.

A New Profilometry System for Precision Measurement of 3D Shape Using the Directional Magnification Control of a Laser Light Stripe (선모양을 한 레이저빔의 방향성 배율 확대를 이용한 정밀 형상측정 시스템)

  • Park, Seung-Kyu;Baik, Sung-Hoon;KIM, Cheol-Jung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.5
    • /
    • pp.60-65
    • /
    • 1997
  • This paper proposes a profilometry system for precise surface contouring of 3D objects using a direc- tionally magnified image of a laser light stripe. The resolution of this system can be improved several times comparad with that of conventional systems without loss of spatial resolution and depth of measurement. A pair of cylindrical lens(a convex lens and a concave lens) are used for a directionally magnified image of a laser light stripe maintaining the same focal plane. Also, image processing procedures for image reconstruc- tions are described.

  • PDF

A development and evaluation of the high power laser measurement system (고출력 레이저광 측정을 위한 계측 장치 제작 및 성능 평가)

  • 황대석;최종운;이영우
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.05a
    • /
    • pp.410-413
    • /
    • 2003
  • We have developed the measurement system for the high power laser The absorber is made of gold-plated copper cavity. The calibration heater is using a manganin(CuMn12Ni ; Isabellenhutte) coil, and output power is measured by using of resistance bridge with composed manganin and copper coil. Developed system can measure for 5∼1000w laser output power range. Calibration factors are 489.13 J/mV at 100W range and 489.13 J/mV at 500W range. Correction factors are 0.99 at 100W range and 1.006 at 500W range.

  • PDF

A Study on the Manufacturing of High Precision Linear Scale Using He-Ne Laser Interference (He-Ne 레이저의 간섭을 이용한 고정밀 리니어 스케일의 제작에 관한 연구)

  • Han, Eung-Gyo;Jeon, Byeong-Uk;Lee, Myeong-Ho;Park, Du-Won;No, Byeong-Ok;Sakurai, Yoshimasa
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.8 no.3
    • /
    • pp.82-92
    • /
    • 1991
  • A study on the manufacturing of High Precision Linear Scalr using He-Ne Laser interference Of late, along with the advancement of precision machining technology, the requirement of super precision measurement increases as time goes on, and the accuracy of standard scale which is a basis of precision measurement has been cognized as a criterion of industrial development in a nationl. In this paper, we described on technology by which we could carve scale lines thru optical method under the condition of laboratory by using the coherence of He-Ne two-mode stabilized laser and in turn, put it to practical use as linear scale for the measurement of length. Hence in this research in the case of setting scale interval to 20 ${\mu}m$, we employed super precision scale-carving device associated with Ar laser and acousto optic modulator in lieu of flashing lamp scale-carving device, and we obtained as experimental result superior linear scales carved within the accuracy of ${\pm}$0.3${\mu}m$.

  • PDF