• Title/Summary/Keyword: laser irradiation

Search Result 623, Processing Time 0.045 seconds

A Study on the Immunohistology in Injury Cure of Rat by using InGaAlP Laser Diode (InGaAlP 레이저다이오드를 적용한 Rat의 착상 치유에서 면역조직화학적 연구)

  • Yu, Seong-Mi;Park, Yong-Pil;Cheon, Min-Woo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.5
    • /
    • pp.431-435
    • /
    • 2009
  • The apparatus has been fabricated using the laser diode and microprocessor unit. The apparatus used a InGaAlP laser diode for laser medical therapy and was designed for a pulse width modulation type to increase stimulation effects. To raise the stimulus effect of the human body, the optical irradiation frequency could be set up. The study has executed in-vivo experiment by employing our own developed laser diode irradiation system to investigate the effects of the InGaAlP laser diode irradiation on the wound healing as a preliminary study aimed at the application of InGaAlP laser diode to wound healing of human skin injury. The study cut out whole skin layers of Sprague-Dawley rat on the back part in 1 cm circle and observed developing effects after executing light irradiation for 9 days, and in result it is found that the light irradiation rat showed earlier wound healing than non-irradiation rat during the experimental period. In addition, there are some differences found regarding the healing process between laser diode irradiated rats and non-irradiated ones.

Underwater Laser Cutting of Thick Stainless Steel in Various Cutting Directions for Application to Nuclear Decommissioning

  • Shin, Jae Sung;Oh, Seong Y.;Park, Seung-Kyu;Kim, Taek-Soo;Park, Hyunmin;Lee, Jonghwan
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.19 no.3
    • /
    • pp.279-287
    • /
    • 2021
  • For application in nuclear decommissioning, underwater laser cutting studies were conducted on thick stainless-steel plates for various cutting directions using a 6 kW fiber laser. For cutting along the horizontal direction with horizontal laser irradiation, the maximum cutting speed was 110 mm·min-1 for a 48 mm thick stainless-steel plate. For cutting along the vertical direction with horizontal laser irradiation, a maximum speed of 120 mm·min-1 was obtained for the same thickness, which confirmed that the cutting performance was similar but slightly better. Moreover, when cutting with vertically downward laser irradiation, the maximum cutting speed was 120 mm·min-1 for a plate of the same thickness. Thus, the cutting performance for vertical irradiation was nearly identical to that for horizontal irradiation. In conclusion, it was possible to cut thick stainless-steel plates regardless of the laser irradiation and cutting directions, although the assist gas rose up due to buoyancy. These observations are expected to benefit laser cutting procedures during the actual dismantling of nuclear facilities.

A Study on the YAG Laser Machining of Cr Thin Films (YAG 레이저에 의한 Cr박막가공에 관한 연구)

  • 강형식;홍성준;박홍식;전태옥
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.1053-1057
    • /
    • 1997
  • Laser thin film process with a Q-switch pulsed YAG laser was performed for micro machining. In this research, we performed basic Cr thin film on glass substrates removal machining experiments. Form experiments, it happens not only evaporration of thin film but also spatter and cohesion of melting substance in working region, when machining a Cr thin film by Q-switch YAG laser beam irradiation. Critical energy of surface irradiation type by irradiation direction of laser in a face composing thin film on the glass is higher than that of back irradiation type, but the latter is favorable because of spatter appearance. In case of image formation position when laser beam is irradiated, the defocus is permitted to a certain extent within forcus depth. Ifexceeds focus depth, formation of pattern is vanishing step by step.

  • PDF

Effects of He-Ne Laser Irradiation on the Activity of the Cultured Fibroblast (He-Ne 레이저 조사가 배양 섬유모세포의 활성에 미치는 영향)

  • Song In-Young;Lee Jae-Hyoung
    • The Journal of Korean Physical Therapy
    • /
    • v.9 no.1
    • /
    • pp.71-79
    • /
    • 1997
  • The purpose of this study were to determined the effect of laser irradiation on the fibroblast activity. Cultures of 3T3 fibroblasts were subjected to Helium Neon laser(632.8 nm) irradiation of various energy density. On one, two and three consecutive days the fibroblast monolayers wert irradiated for period from 0 to 32 minutes with 8 mW of average output power. The fibroblast activity was determined by the quantitative assay of MTT, SRB and NR after incubation of the fibroblasts for 24 hours. Results show that exposure duration from 2 min to 32 min could increase MTT at three consecutive days, whereas control and 1 min, one and two days irradiation had were not inclosed. The SRB and NR were inclosed at two and three consecutive days from 2 min to 32 min, whereas control and 1 min, and once radiation were not increased. These result demonstrate that energy density from 0.48 to 7.64 J/cm could increase cellular protein contents and fibroblast activity at more than twice irradiation of laser, whereas low energy density (less than 0.24 J/m) and once irradiation of laser had no effect. The results suggest that the beneficial effect of the He-Ne laser with adequate dose on fibroblast activity in vitro.

  • PDF

An Experimental Study on the Effect of Low Level Laser and Some Cytokines on Gene Expression of Human Gingival Fibroblasts (저출력레이저조사와 염증성 자극물질이 치은섬유아세포의 유전자 발현에 미치는 영향에 관한 실험적 연구)

  • Jung-Min Kim;Keum-Back Shin
    • Journal of Oral Medicine and Pain
    • /
    • v.19 no.2
    • /
    • pp.57-71
    • /
    • 1994
  • Gingival fibroblasts were cultured and subjected to the test of Northern blot analysis for the demonstration of various mRNA expression in response to the low level laser treatment. For duplication of in vivo. Wound healing process, fibroblasts were pretreated with proinflammatory cytokine interleukin-1$\beta$(IL-1$\beta$) or mitogenic substance phorbol 12-myristate 13-acetate(PMA) prior to laser irradiation. The results were as follows : 1. By the laser irradiation, the gene expression of collagen type I was markedly increased I n gingival fibroblasts, especially in the case of PMA pretreatment. The gene expression of collagen type IV, however, was not only affected by laser irradiation but also by chemical cell stimulation. 2. Oncogene v-myc expression was affected by both laser irradiation and IL-1$\beta$ or PMA stimulation, But v-fos gene expression was not detected in any case of this experimental system. 3. Heat shock gene(Hsp 70)was expressed constiutively, but slightly increased by laser irradiation. 4. mRNA of fibroblast growth factor(FGF) was induced by both laser irradiation and IL-1$\beta$ or PMA treatment.

  • PDF

AN EXPERIMENTAL STUDY ON THE TEMPERATURE CHANGE OF THE PULP CHAMBER INDECED BY THE CO2 LASER IRRADIATION (CO2레이저 조사에 따른 치수강내 온도변화에 관한 실험적 연구)

  • Lee, Jong-Man;Park, Dong-Soo;Lee, Chang-Young;Lee, Chung-Suck
    • Restorative Dentistry and Endodontics
    • /
    • v.10 no.1
    • /
    • pp.43-53
    • /
    • 1984
  • The purpose of this study was to suggest the use of laser energy in the the field of operative dentistry without considerable pulpal damage and significant effects on the dental hard tissue, additionally to find out the methods which could control the temperature rise. The laser beam (CW $CO_2$ laser, output: 6W, beam diameter: 1.5mm) was focused on the center of the occlusal surface of extracted lower molars. A Ge lens (focal length 200mm) was used to focus the primary laser beam. In order to vary the total amount of the same irradiated energy, experimental subjects were devided into three groups: continuously irradiated group, intermittently irradiated group, and water-cooled group after continuous laser irradiation. Temperature changes in the pulp chamber after laser irradiation were measured and recorded by the digital thermometer and recorder. The following results were obtained: 1. Temperatures in the pulp chamber were raised up in the order of the continuously irradiated group, intermittently irradiated group, water-cooled group after continuous laser irradiation. 2. In the continuously irradiated group, the temperature was raised up $1.7^{\circ}C$, $3.8^{\circ}C$, $7.3^{\circ}C$, $17.2^{\circ}C$ after 2, 4, 8, 16 seconds of the irradiation of laser. In the intermittently irradiated group, the changes were $1.2^{\circ}C$, $3.4^{\circ}C$, $6.3^{\circ}C$, $11.1^{\circ}C$, respectively. In the water-cooled group after continuous laser irradiation, the changes were $0.0^{\circ}C$, $0.8^{\circ}C$, $1.6^{\circ}C$, $6.9^{\circ}C$, respectively. 3. The starting time of temperature rise in the pulp chamber had no connection with laser irradiation time.

  • PDF

Effect of Laser Pre-Drilling on Insertion Torque of Orthodontic Miniscrews: A Preliminary Study

  • Kim, Keun-Hwa;Choi, Sung-Hwan;Cha, Jung-Yul;Hwang, Chung-Ju
    • Journal of Korean Dental Science
    • /
    • v.10 no.2
    • /
    • pp.66-73
    • /
    • 2017
  • Purpose: To evaluate the effect of different-sized drill tips and laser irradiation times on the initial stability of orthodontic miniscrews placed in Er,Cr:YSGG-laser pre-drilled holes in an animal model. Materials and Methods: Laser pre-drilled holes were made in dog mandibular bone with an Er,Cr:YSGG laser using irradiation times of 5, 7, 9, 11, and 13 seconds, and tip diameters of 0.4 and 0.6 mm. The maximum diameter and depth of the pre-drilled holes was measured with micro computed tomography. The maximum insertion torque was measured during placement the miniscrew. Result: Laser pre-drilled holes were conical shaped. The maximum diameter of pre-drilled holes increased with longer laser irradiation times (P>0.05) and larger tip diameters (P<0.05). The depth of pre-drilled holes increased with longer laser irradiation times and larger tip diameters (P<0.05). When the 0.4 mm tip, but not the 0.6 mm tip, was used, the insertion torque decreased significantly with longer laser irradiation times (P<0.05). Conclusion: Tip diameter impacted insertion torque more than irradiation time. It takes at least 9 seconds using a 0.6 mm tip to create a 0.8 mm diameter and 1.0 mm depth hole in thick cortical bone.

Excimer laser crystallization of sputtered a-Si films on plastic substrates

  • Cho, Hans-S;Jung, Ji-Sim;Kim, Do-Young;Park, Young-Soo;Park, Kyung-Bae;Kwon, Jang-Yeon;Noguchi, Takashi
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.962-965
    • /
    • 2004
  • In this work, thin films of amorphous silicon (a-Si) were formed on plastic substrates by sputtering deposition and crystallized using excimer laser irradiation. As the entire process is conducted at room temperature, and the laser irradiation-induced heating is confined to the thin film, the plastic substrate is not subjected to thermal stresses. The microstructure resulting from the laser irradiation was dependent on the laser irradiation energy density and the composition of the underlying buffer layers. It was found that a layer of AlN deposited as a buffer between the plastic and the a-Si film increased the endurance of the a-Si film under laser irradiation, and resulted in polycrystalline Si grains up to 100nm in diameter.

  • PDF

Effects of Laer-beam Irradiation Therapy for Diarrheal Piglets (Laser광선요법이 설사자돈에 미치는 영향)

  • 장경진;유종철;조용성;배춘식
    • Journal of Veterinary Clinics
    • /
    • v.14 no.2
    • /
    • pp.168-171
    • /
    • 1997
  • The present experiment was conducted to compare the therapeutic effects of laser irradiation on Kyo-So Hyul with those of antidisrrheal drugs gentamycin, berberine and sulfisomidine for 173 piglets with diarrhea as major symptoms. The results obtained were as follows; antidiarrheal drugs were effective in fifty nine (78%) of seventy six piglets and ineffective in seventeen (22%) of seventy six piglets. Laser irradiation on the Kyo-So Hyul were proved as effective in eighty eight (91%) of ninety seven piglets and invalid in nine (9%) of ninety seven piglets.

  • PDF

The biomedical effect of 655nm Laser Diode irradiation (655nm 레이저 다이오드 조사에 따른 생물학적 특성 평가)

  • Cheon, Min-Woo;Kim, Seong-Hwan;Park, Yong-Pil;Lee, Ho-Shik;Kim, Tae-Gon;Park, No-Bong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.397-398
    • /
    • 2008
  • This paper performed the basic study for fabricating the low level laser therapy apparatus, and one of the goals of this paper was to make this apparatus used handily. The apparatus has been fabricated using the 655nm laser diode and microprocessor unit. The apparatus used a 655 nm laser diode for laser medical therapy and was designed for a pulse width modulation type to increase stimulation effects. And then, each experiment was performed to irradiation group and non-irradiation group for cells. MTT assay method was chosen to verify the cell increase of two groups and the effect of irradiation on cell proliferation was examined by measuring 590nm transmittance of ELISA reader. As a result, the cell increase of cells was verified in irradiation group as compared to non-irradiation group.

  • PDF