• Title/Summary/Keyword: laser irradiating

Search Result 54, Processing Time 0.032 seconds

ITO Thin Film Ablation Using KrF Excimer Laser and its Characteristics

  • Lee, Kyoung-Chel;Lee, Cheon;Le, Yong-Feng
    • Transactions on Electrical and Electronic Materials
    • /
    • v.1 no.4
    • /
    • pp.20-24
    • /
    • 2000
  • This study aimed to develop ITO(Indium Tim Oxide) tin films ablation with a pulsed type KrF excimer laser required for the electrode patterning application in flat panel display into small geometry on a large substrate are. The threshold fluence for ablating ITO on glass substrate is about 0.1 J/㎠. And its value is much smaller than that using 3 .sup rd/ harmonic Nd:YAG laser. Through the optical microscope measurement the surface color of the ablated ITO is changed into dark brown due to increase of surface roughness and transformation of chemical composition by the laser light. The laser-irradiated regions were all found to be electrically isolating from the original surroundings. The XPS analysis showed that the relative surface concentration of Sn and In was essentially unchanged (In:Sn=5:1)after irradiating the KrF excimer laser. Using Al foil made by 2$\^$nd/ harmonic Na:YAG laser, the various ITO patterning is carried out.

  • PDF

Surface Hardening Characteristics of SK5 Steel by Pulsed YAG LASER (YAG 레이저에 의한 SK5 표면경화 특성)

  • 강형식;문종현;전태옥;박홍식
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.921-924
    • /
    • 1995
  • Case hardening behavior of carbon tool steel(SK5) was investigated after pulsed YAG laser irradiation. In the case od beam passes,martensite formed in the melt zone and in former pearlite regions of the austenitization zone exhibits vary high Vickers hardness values. The molten depth and width decrease as the beam power density increase. The influence of depth and width of color painted specimen was also investigated. The molten zone of the black painted specimen was the largest. The were loss of the black painted specimen was smaller than any other painted or raw material.

  • PDF

Maskless patterning of Photoresist by laser (레이저에 의한 포토레지스트의 마스크리스 페터닝)

  • Lee, Kyoung-Cheol;Kim, Jae-Kwan;Lee, Cheon;Choi, Jin-Ho;Lee, Kang-Ook;Choi, Ik-Soon
    • Proceedings of the KIEE Conference
    • /
    • 1998.11c
    • /
    • pp.886-888
    • /
    • 1998
  • By irradiating photoresist on Si or glass with $Ar^+$ (${\lambda}$=514 nm, CW) and Nd:YAG (${\lambda}$=266 and 532nm, pulse) laser beam, the photoresist was etched masklessly in air. Using a fourth harmonic Nd:YAG laser beam, the etching threshold of energy fluence was $25\;J/cm^2$ and the damage of substrate was appeared over $40\;J/cm^2$.

  • PDF

The Effects of Laser Irradiation on Human Plasma $\beta-endorphin$ Levels (Laser가 정상인의 혈장내 $\beta-endorphin$ 농도에 미치는 영향)

  • Seo Yeon-Soon;Park Rae-Joon;Park Young-Han
    • The Journal of Korean Physical Therapy
    • /
    • v.9 no.1
    • /
    • pp.157-166
    • /
    • 1997
  • The purpose of this study was to determine the effects of laser Irradiation on Human plasma $\beta-endorphin$ levels, by treating with low level helium-neon (He-Ne) and Infrared(lR) laser. The Laser was fixed frequency of 2400Hz by continuous scanning and irradiating time was 8 minutes each point. Blood samples were taken at before, after, after 15min's treatment and Plasma $\beta-endorphin$ was measured by radioimmunoassay. The samples for this study were 6 normal subjects(3male, 3female). The data were analyzed by paired t-test, one-way ANOVA and simple regression. The results of this study were as follows : 1. The human plasma $\beta-endorphin$ levels were noted as significant increase in after-treatment $(22.84{\pm}10.63pg/ml)$ as compared with before-treatment $(16.96{\pm}9.23pg/ml)$ and significant increase in after 15min's $(27.27{\pm}8.81pg/ml)$ as compared with after-treatment (p<0.05). 2. There were no significant changes in plasma g-endorphin levels between male and female. 3. The human plasma $\beta-endorphin$ levels were high associated in between session reliability (p<0.05).

  • PDF

Developing an interface strength technique using the laser shock method

  • James A. Smith;Bradley C. Benefiel;Clark L. Scott
    • Nuclear Engineering and Technology
    • /
    • v.55 no.2
    • /
    • pp.432-442
    • /
    • 2023
  • Characterizing the behavior of nuclear reactor plate fuels is vital to the progression of advanced fuel systems. The states of pre- and post-irradiation plates need to be determined effectively and efficiently prior to and following irradiation. Due to the hostile post-irradiation environment, characterization must be completed remotely. Laser-based characterization techniques enable the ability to make robust measurements inside a hot-cell environment. The Laser Shock (LS) technique generates high energy shockwaves that propagate through the plate and mechanically characterizes cladding-cladding interfaces. During an irradiation campaign, two Idaho National Laboratory (INL) fabricated MP-1 plates had a fuel breach in the cladding-cladding interface and trace amounts of fission products were released. The objective of this report is to characterize the cladding-cladding interface strengths in three plates fabricated using different fabrication processes. The goal is to assess the risk in irradiating future developmental and production fuel plates. Prior LS testing has shown weaker and more variability in bond strengths within INL MP-1 reference plates than in commercially produced vendor plates. Three fuel plates fabricated with different fabrication processes will be used to bound the bond strength threshold for plate irradiation insertion and assess the confidence of this threshold value.

A Study on Safety, Performance and Clinical effectiveness Test Guideline of Versatile Ophthalmic Laser System (다목적 안과용 레이저 시스템 안전성 성능평가 및 임상적 유효성평가 가이드라인 수립을 위한 연구)

  • Kim, You Rim;Yu, Woo Jin;Park, Ho Joon;Jang, Won Seuk
    • Journal of Biomedical Engineering Research
    • /
    • v.40 no.6
    • /
    • pp.250-259
    • /
    • 2019
  • Ophthalmic Laser System is widely used in Selective Laser Trabeculoplasty of Open Angle Glaucoma and Ocular Hypertension. Versatile ophthalmic laser system is a medical device with technology that checks the condition of the treatment area by irradiating a continuous laser pulse on the treatment area, and monitoring the microbubble reaction caused by the temperature increase of the melanosome through the ultrasonic signal and the optical signal sensor. It performs selective laser treatment without damaging the photoreceptor by controlling the wavelength of the laser when microbubbles are detected. This study aims to suggest a guideline for evaluating safety, performance and clinical effectiveness of Versatile Ophthalmic Laser System in accordance with the growing technology. International Standards, Regulations, and Clinical Trial Protocols were investigated and analyzed for this study. As a result of this study, the safety, performance and clinical effectiveness test guideline for Versatile Ophthalmic Laser System were proposed. This guideline will ensure the safety and efficacy of Medical device, and furthermore it is expected to be able to promote the development of technology development by supporting a clinical trial plan.

Bistable Liquid Crystal Device Realized on Microscopic Orientational Pattern

  • Kim, Jong-Hyun;Yoneya, Makoto;Yokoyama, Hiroshi
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.187-190
    • /
    • 2005
  • Alignment pattern of checkerboard was constructed by the stylus of atomic force microscope. Orientational bistability of the nematic liquid crystal was realized on that frustrated surface alignment. Macroscopic orientational switching between two perpendicular directions took place by an appropriate in-plane electric field. The threshold electric fields decreased in both switching directions as temperature increased. The focused laser heated up only the limited domains in the cell including a light-absorbing medium. Irradiating the laser concurrently with an appropriate electric field, we switched the selected unit domains in the alignment pattern. The switched domains maintained stably the switched direction without the disturbance from the exterior. Extending and repeating this process, we realized extremely fine devices of bistable switching.

  • PDF

LASER ABLATION OF Bi-SUBSTITUTED GADOLINIUM IRON GARNET FILMS WITH LARGE FARADAY ROTATION

  • Watanabe, N.;Tsushima, K.
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.5
    • /
    • pp.720-725
    • /
    • 1995
  • Bi-substituted gadolinium iron garnet films were deposited on GGG(111) and NGG (111) substrates by irradiating KrF excimer laser onto targets having compositions of $Bi_{x}Gd_{3-x}Fe_{5}O_{12}$ ($2.0{\leq}x{\leq}3.0$) under substrate temperature of $580~620^{\circ}C$. Analysis on structure, composition and angle of Faraday rotation, ${\theta}_{F}$, were carried out. The composition, the structure and the magneto-optical properties of the obtained films were found to be strongly dependent both on the compositions of the targets and on the pressure of oxygen. Before annealing in air, all films showed ${\theta}_{F}{\geq}0$ at ${\lambda}=6328{\AA}$, while several films showed ${\theta}_{F}{\leq}0$ after the annealing. The highest value of Bi-substitution up to x = 1.76 with uniform composition was obtained.

  • PDF

Fabrication and Transfer of Laser Induced Graphene (LIG) Electrode for Flexible Substrate-based Electrochemical Sensor Applicatins (유연 기판 기반 전기화학 센서 응용을 위한 레이저 유도 그래핀 전극 제작 및 전사 연구)

  • Kim, Jeong Dae;Kim, Taeheon;Pak, Jungho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.3
    • /
    • pp.406-412
    • /
    • 2018
  • This paper describes the fabrication process of laser induced graphene (LIG) and its transfer method on to a flexible and stretchable PDMS substrate. By irradiating CO2 laser on a polyimide(PI) film surface, a localized high temperature is created, resulting in a three-dimensional porous graphene network structure with good conductivity. This LIG electrode is relatively easy to fabricate and since it is very weak the LIG electrode was transferred to a flexible PDMS substrate to increase the sturdiness as well as possible use in flexible applications. Sheet resistance, thickness, and electrochemical activity of the fabricated in-situ LIG electrodes have been examined and compared with the LIG electrodes after transferring to PDMS elastomer. The properties of the LIG electrodes were also examined depending on the $CO_2$ laser power. As the irradiated laser power increased, the LIG electrode resistance decreases and the LIG electrode thickness increased. At 4.8 W of laser power, the average sheet resistance and thickness of the fabricated LIG electrodes were approximately $31.7{\Omega}/{\Box}$ and $62.67{\mu}m$, respectively. Moreover, the electrochemical activity of the fabricated LIG electrode at 4.8 W of laser power showed a high oxidation current of $28.2{\mu}A$ after transferring to PDMS.

THERMAL CHANGE OF THE DENTIN BY USE OF PULSED Nd : YAG LASER (Pulsed Nd : YAG 레이저 조사에 의한 상아질의 온도변화에 대한 연구)

  • Kim, Young-Il;Hwang, In-Nam;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.21 no.1
    • /
    • pp.218-226
    • /
    • 1996
  • This study was performed to evaluate the possibility of pulpal damage by measuring temperature change occured in dentin according to the thickness of dentin, the time of irradiation and the output of laser energy when the dentin surfaces were irradiated with Nd-YAG laser under water coolant and no water coolant. Sound upper and lower molar teeth were sectioned with 1mm, 1.5mm and 2mm thickness of dentin discs and divided into 4 groups by dentin thiness. 0.5 watt, 1 watt, 1.5 watt and 2 watt-energied beam of pulsed 10 p.p.s of Nd : YAG laser was applied respectively to dentin surfaces for 8 secs and 16 secs when water coolant is used or not.Ant then the temperature changes occurd in dentin were measured at opposite surfaces of laser-irradiated dentin surfaces with digital thermometer. The results were as follow. 1. When the amount of irradiated energy was same, the temperatue changes of dentin were higher as the thickness of dentin discs was thinner(p<0.01). 2. When the amount of irradiated energy and the thickness of dentins were same, The temperature changes of dentin were lower under water coolant than under no water coolant in all groups(p<0.01). 3. With the increase of time of irradiation, the temperature changes of Dentin became higher in all groups and were steeply increased at initial period of irradiation of laser. 4. Under the same thickness of dentin, the temperature changes of dentin became higher as irradiated energy was increased. These results suggest that when the beam of Nd : YAG Laser is irradiated to dential hard tissue, amount of irradiating energy, thickness of dentin, using water coolant must be considered in order to minimize thermal damage of the pulp.

  • PDF