• Title/Summary/Keyword: laser dentistry

Search Result 571, Processing Time 0.03 seconds

EFFECTS ON ER,CR:YSGG LASER ON PERI-IMPLANTITIS (임프란트 주위염에 대한 Er,Cr:YSGG 레이저 조사가 미치는 영향)

  • Choi, Sung-Lim;Kim, Jin-Hwan;Hwang, Dong-Hyeon;Min, Seung-Ki
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.30 no.5
    • /
    • pp.428-436
    • /
    • 2008
  • For Longevity of implant, considerations of biomechanical and microbiological aspects must be done. Recently, due to the remarkable development of bone grafting procedure. Implant has been implanted into the more favorable sites but peri-implantitis resulted from periodontal bacteria may obscure the long-term prognosis. Although many different modalities have been introduced to treat the failed implant. Implant's surface and irreversible bony destruction around the implant prevents good result. After Er,Cr:YSGG (waterlase) laser using the wave-length of 2780nm has been introduced to dental field, good results have been reported. Because waterlase uses the hydrokinetic force of water. It is excellent device to detoxify the implant surface mechanically without the heat generation and damage to the implant surface. We designed to evaluate waterlase effect on the peri-implantitis has been occurred after implantation. Four beagle dogs were involved. We have made four premolar extraction in each right and left side of the lower jaw and placed two implants in the anterior of the jaw as a control and six implant were placed posterior in each socket after extraction immediately as an experimental group. We tied floss-silk in each implant to make peri-implantitis intentionally. After three months, we explored peri-implant sites on each experimental fixtures. Using waterlase laser irradiation was performed on that implantitis sites under 3W, air 30% and water 20% intensity for 2 minutes. In control group, we repositioned the flap to cover the exposed fixture without any supportive care. Three months later, we sacrificed experimental animals and extracted and preparated bone blocks with Donath and Breuner (982), Donath (988)'s methods and examined under microscope. We have obtained good re-osseointegration around fixtures after treating with waterlaser irradiation. But it was shown fibroosseointegration in the control group.

Low-level laser therapy affects osseointegration in titanium implants: resonance frequency, removal torque, and histomorphometric analysis in rabbits

  • Kim, Jong-Ryoul;Kim, Sung-Hee;Kim, In-Ryoung;Park, Bong-Soo;Kim, Yong-Deok
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.42 no.1
    • /
    • pp.2-8
    • /
    • 2016
  • Objectives: The purpose of this study was to investigate the effects of low-level laser therapy (LLLT) with a diode gallium-aluminum-arsenide (Ga-Al-As) low-level laser device on the healing and attachment of titanium implants in bone. Materials and Methods: Thirteen New Zealand white male rabbits weighing $3.0{\pm}0.5kg$ were used for this study. Dental titanium implants (3.75 mm in diameter and 8.5 mm in length, US II RBM plus fixture; Osstem, Seoul, Korea) were implanted into both femurs of each rabbit. The rabbits were randomly divided into a LLLT group and a control group. The LLLT was initiated immediately after surgery and then repeated daily for 7 consecutive days in the LLLT group. Six weeks and 12 weeks after implantation, we evaluated and compared the osseointegration of the LLLT group and control group, using histomorphometric analysis, removal torque testing, and resonance frequency analysis (RFA). The results were statistically significant when the level of probability was 0.05 or less based on a non-parametric Mann-Whitney U-test. Results: The implant survival rate was about 96%. Histologically and histomorphometrically, we observed that the titanium implants were more strongly attached in LLLT group than in control group. However, there was no significant difference between the LLLT group and control group in removal torque or RFA. Conclusion: Histologically, LLLT might promote cell-level osseointegration of titanium implants, but there was no statistically significant effects.

INTERRATER RELIABILITY OF CARIES DIAGNOSIS BY LASER FLUORESCENCE (레이저형광 우식진단법의 검사자간 신뢰도에 관한 연구)

  • Lee, Kwang-Hee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.4
    • /
    • pp.668-672
    • /
    • 2001
  • The purpose of study was to measure the interrater reliability of the caries diagnostic instrument, Diagnodent(KaVo, Germany), using a new laser fluorescence technique. Occlusal surfaces and smooth surfaces of one hundred extracted human premolars and molars were examined by four dentists. Pearson correlation coeffcients were 0703 to 0.870 for occlusal surfaces and 0.764 to 0.932 for smooth surfaces (P<0.01, all). Reliability coefficients which were calculated by intraclass correlation coefficients were 0.9450 for occlusal surfaces and 0.9605 for smooth surfaces. Therefore, the interrater reliability of caries diagnosis by Diagnodent is very high, and the rater training would be necessary more for occlusal surfaces than for smooth surfaces.

  • PDF

Synergistic Effects of Chios Gum Mastic Extract and Low Level Laser Therapy on Osteoblast Differentiation

  • Lee, Ki-Hyun;Kim, Young-Seok;Yu, Su-Bin;Kang, Hae-Mi;Kwak, Hyun-Ho;Kim, In-Ryoung;Park, Bong-Soo
    • International Journal of Oral Biology
    • /
    • v.41 no.2
    • /
    • pp.53-62
    • /
    • 2016
  • In the present study, we evaluated the effect of CGM on osteogenic differentiation of cultured osteoblasts, and determined whether combination treatment with LLLT had synergistic effects on osteogenic differentiation. The results indicated that CGM promoted proliferation, differentiation, and mineralization of osteoblasts at the threshold concentration of $10{\mu}g/ml$; whereas, CGM showed cytotoxic properties at concentrations above $100{\mu}g/ml$. ALP activity and mineralization were increased at concentrations above $10{\mu}g/ml$. CGM in concentrations up to $10{\mu}g/ml$ also increased the expression of osteoblast-activated factors including type I collagen, BMP-2, RUNX2, and Osterix. The CGM ($50{\mu}g/ml$) and LLLT (80 mW for 15 sec) combination treatment group showed the highest proliferation levels, ALP activity, and mineralization ratios. The combination treatment also increased the levels of phosphorylated forms of p38, ATF2, PKD, ERK, and JNK. In addition, the osteoblast differentiation factors including type I collagen, BMP-2, RUNX2, and Osterix protein levels were clearly increased in the combination treatment group. These results suggested that the combination treatment of CGM and LLLT has synergistic effects on the differentiation and mineralization of osteoblastic cells.

How will surface treatments affect the translucency of porcelain laminate veneers?

  • Turgut, Sedanur;Bagis, Bora;Ayaz, Elif Aydogan;Korkmaz, Fatih Mehmet;Ulusoy, Kivanc Utku;Bagis, Yildirim Hakan
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.1
    • /
    • pp.8-13
    • /
    • 2014
  • PURPOSE. The purpose of this study was to evaluate whether surface treatments affect the translucency of laminate veneers with different shades and thicknesses. MATERIALS AND METHODS. A total of 224 disc-shaped ceramic veneers were prepared from A1, A3, HT (High Translucent) and HO (High Opaque) shades of IPS e.max Press (Ivoclar Vivadent) with 0.5 mm and 1.0 mm thicknesses. The ceramics were divided into four groups for surface treatments. Group C: no surface treatments; Group HF: etched with hydrofluoric acid; Group SB: sandblasted with 50-${\mu}m$ $Al_2O_3$; and Group L; irradiated with an Er;YAG laser. A translucent shade of resin cement (Rely X Veneer, 3M ESPE) was chosen for cementation. The color values of the veneers were measured with a colorimeter and translucency parameter (TP) values were calculated. A three-way ANOVA with interactions for TP values was performed and Bonferroni tests were used when appropriate (${\alpha}=0.05$). RESULTS. There were significant interactions between the surface treatments, ceramic shades and thicknesses (P=.001). For the 0.5-mm-thick specimens there were significant differences after the SB and L treatments. There was no significant difference between the HF and C treatments for any shades or thicknesses (P>.05). For the 1-mm-thick ceramics, there was only a significant difference between the L and C treatments for the HT shade ceramics (P=.01). There were also significant differences between the SB and C treatments except not for the HO shades (P=.768). CONCLUSION. The SB and L treatments caused laminate veneers to become more opaque; however, HF treatment did not affect the TP values. When the laminate veneers were thinner, both the shade of the ceramic and the SB and laser treatments had a greater effect on the TP values.

Effects of single-dose, low-level laser therapy on pain associated with the initial stage of fixed orthodontic treatment: A randomized clinical trial

  • Qamruddin, Irfan;Alam, Mohammad Khursheed;Abdullah, Habiba;Kamran, Muhammad Abdullah;Jawaid, Nausheen;Mahroof, Verda
    • The korean journal of orthodontics
    • /
    • v.48 no.2
    • /
    • pp.90-97
    • /
    • 2018
  • Objective: The aim of this study was to assess the analgesic effect of a single application of low-level laser therapy (LLLT) on spontaneous pain and pain on chewing after placement of initial archwires. Methods: Forty-two patients (26 women, 16 men) were randomly recruited for this split-mouth randomized clinical trial. Each patient received super-elastic nickel-titanium (NiTi) initial archwires (0.012, 0.014, 0.016, and 0.018-inch [in]) in the maxilla for leveling and alignment for an interval of 4 weeks between archwires. One side of the mouth was randomly designated as experimental, while the other side served as placebo. After insertion of each archwire, the experimental side was irradiated with a diode laser for 3 seconds each on 5 points facially and palatally per tooth, from the central incisor to first molar. On the placebo side, the laser device was held the same way but without laser application. A numerical rating scale was used to assess the intensity of spontaneous and masticatory pain for the following 7 days. The Mann-Whitney U test was used to compare pain scores between sides. Results: Patients in the LLLT group exhibited significantly lower mean scores for spontaneous pain after insertion of the initial two archwires (0.012-in and 0.014-in NiTi; p < 0.05), while there was no significant difference for 0.016-in and 0.018-in wires between the LLLT and placebo groups. LLLT significantly reduced chewing pain scores (p < 0.05) for all archwires. Conclusions: A single dose of LLLT considerably lessened postoperative pain accompanying the placement of super-elastic NiTi wires for initial alignment and leveling.

Review of root canal irrigant delivery techniques and devices (최신 근관 세척 방법과 기구에 대한 고찰)

  • Yoo, Yeon-Jee;Shin, Su-Jeong;Baek, Seung-Ho
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.3
    • /
    • pp.180-187
    • /
    • 2011
  • Introduction: Eliminating the residual debris and bacteria in the root canal system is one of the main purposes of the endodontic treatment. However, the complexity on the anatomy of the root canal system makes it difficult to eliminate the bacterial biofilm existing along the root canal surface and necrotic pulp tissue by mechanical instrumentation and chemical irrigation. Recently, more effective irrigant delivery systems for root canal irrigation have been developed. The purpose of this review was to present an overview of root canal irrigant delivery techniques and devices available in endodontics. Review: The contents of this paper include as follows; - syringe-needle irrigation, manual dynamic irrigation, brushes - sonic and ultrasonic irrigation, passive ultrasonic irrigation, rotary brush, RinsEndo, EndoVac, Laser Conclusion: Though technological advances during the last decade have brought to fruition new agitation devices that rely on various mechanisms, there are few evidence based study to correlate the clinical efficacy of these devices with improved outcomes except syringe irrigation with needle and ultrasonic irrigation. The clinicians should try their best efforts to deliver antimicrobial and tissue solvent solutions in predictable volumes safely to working length.