• Title/Summary/Keyword: laser dentistry

Search Result 571, Processing Time 0.031 seconds

Microshear bond strength according to dentin cleansing methods before recementation

  • Tasar, Simge;Ulusoy, Mutahhar Muhammed;Meric, Gokce
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.2
    • /
    • pp.79-87
    • /
    • 2014
  • PURPOSE. The aim of this study was to determine the efficiency of Erbium, Chromium: Yttrium-Scandium-Gallium-Garnet laser in different output powers for removing permanent resin cement residues and therefore its influence on microshear bond strength compared to other cleaning methods. MATERIALS AND METHODS. 90 extracted human molars were sectioned in 1 mm thickness. Resin cement was applied to surface of sliced teeth. After the removal of initial cement, 6 test groups were prepared by various dentin surface treatment methods as follows: no treatment (Group 1), ethylene diamine tetra acetic acid application (Group 2), Endosolv R application (Group 3), 1.25 W Erbium, Chromium:Yttrium-Scandium-Gallium-Garnet laser irradiation (Group 4), 2 W Erbium, Chromium:Yttrium-Scandium-Gallium-Garnet laser irradiation (Group 5) and 3.5 W Erbium, Chromium:Yttrium-Scandium-Gallium-Garnet laser irradiation (Group 6). The topography and morphology of the treated dentin surfaces were investigated by scanning electron microscopy (n=2 for each group). Following the repetitive cementation, microshear bond strength between dentin and cement (n=26 in per group) were measured with universal testing machine and the data were analyzed by Kruskal Wallis H Test with Bonferroni correction (P<.05). Fracture patterns were investigated by light microscope. RESULTS. Mean microshear bond strength ${\pm}$ SD (MPa) for each group was $34.9{\pm}17.7$, $32.1{\pm}15.8$, $37.8{\pm}19.3$, $31.3{\pm}12.7$, $44.4{\pm}13.6$, $40.2{\pm}13.2$ respectively. Group 5 showed significantly difference from Group 1, Group 2 and Group 4. Also, Group 6 was found statistically different from Group 4. CONCLUSION. 2 W and 3.5 W Erbium, Chromium: Yttrium-Scandium-Gallium-Garnet laser application were found efficient in removing resin residues.

Clinical Effect Of Low Level Laser Therapy In The Treatment Of Dentin Hypersensitivity Following Periodontal Surgery (치주수술 후 상아질 지각과민증에 대한 저수준 레이저 처치의 임상적 효과)

  • Kim, Nam-Yun;Lim, Sung-Bin;Chung, Chin-Hyung
    • Journal of Periodontal and Implant Science
    • /
    • v.26 no.1
    • /
    • pp.230-243
    • /
    • 1996
  • Root surface exposure due to gingival recession after periodontal surgery, dentin exposure after root planing elicit pain response when exposed to mechanical, heat, chemical or osmotic stimulation. Especially, patients treated with periodontal surgery, show high frequency and there have been reports showing the 1 out of 7 patients have dentin hypersensitivity. There have been many studies on the clinical effects of various materials on the treatment of dentin hypersensitivity. but, none could provide absolute clinical efficacy. In this study, 45 teeth from 30 patients, who had had periodontal surgery and showed dentin hypersensitivity after surgery were chosen for the experimental group and they were illuminated with laser, 15teeth were chosen for the control group and they were not exposed to laser. After this dentin hypersensitivity was elicited by tactile, compressed air, cold water and then, the degree was evaluated using NRS(Numerical Rating Scale). And during LLLT(Low Level Laser Therapy) semiconductor laser using Gallium - Arsenide as a diode was illuminated for 180 seconds at a frequency of 7(500Hz). This therapy was done 10 times, and each time the changes in dentin hypersensitivity was evaluated using NRS. The results were as follows : 1. After treat with LLLT on dentin hypersensitivity due to periodontal surgery, 22.2% showed total loss of dentin hypersensitivity, 60.0% showed loss of tactile dentin hypersensitivity, 48.8% showed loss of compressed air dentin hypersensitivity, 22.2% showed loss of cold water dentin hypersensitivity. 2. As a result of clinical evaluation of dentin hypersensitivity using NRS, there was significant increase in improvement of dentin hypersensitivity in the experimental group compare to the control group(P<0.05). And there was almost no natural loss of dentin hypersensitivity in the control group. 3. In comparison of the stages of evaluation, there was significant difference in between experimental and control group. after the second visit(P<0.05), and the difference increased with each visit.

  • PDF

BONE HEALING CAPACITY IN THE FRACTURE OF RABBIT MANDIBULAR BONE USING LOW-LEVEL LASER (가토 하악골 절단부의 저수준 레이저 처치가 골치유에 미치는 영향)

  • Bae, Yong-Hyeon;Han, Se-Jin;Kim, Kyung-Wook
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.35 no.2
    • /
    • pp.120-124
    • /
    • 2009
  • The concept of biostimulation of wounds by low-level laser therapy(LLLT) is attracting considerable attention. Although its effect on whole tissues has been studied quite extensively, the biological and cellular mechanisms underlying LLLT have not been clarified. In an experimental radius fracture in rabbits, Tang and Chai reported that LLLT enhanced the activity of red blood cells, macrophages, fibroblasts, chondrocytes, and osteoclasts within the fracture area. The purpose of the present study was to evaluate the effect of LLLT with a GaAlAs diode laser device on bone healing in rabbit mandibular fractures. We use 12 rabbits for this study. All rabbits were fractured mandible angle area using saw in anesthetic condition. In control group(n=6), none treatment was performed at fracture site. In experimental group(n=6), LLLT with a GaAlAs diode laser was radiated at fracture site daily for 7 days. All rabbits were sacrificed at 6 weeks later from performed fracture day. We studied the immunohistochemical staining of CD34 and Vimentin and the histochemical analysis for calcium and phosphorus content. The results were as follows. 1. In the histological and immunohistological staining, after 6week, fibroblasts, osteogenic cells and collgen fibers were observed more in experimental group than in control group. 2. In the histochemical analysis, the amount of calcium and phosphorus contents of the experimental group were more than the control group. From the results obtained, we suggest that the bone healing is stimulated by low-level laser irradiation in bone fractures.

Fixed prostheses fabricated by direct metal laser sintering system: case report (Direct metal laser sintering 방식을 이용하여 제작한 다양한 고정성 보철물 수복 증례)

  • Baek, Ju-Won;Shin, Soo-Yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.3
    • /
    • pp.246-254
    • /
    • 2016
  • Nowadays, 3 dimentional (3D) printing, especially Direct Metal Laser Sintering (DMLS) system is used in dentistry. DMLS system has recently been introduced for fabrication metal framework for metal ceramic crowns to overcome the disadvantages of the casting method and computer aided design/computer aided manufacturing (CAD/CAM) milling system. DMLS system uses a high-temperature laser beam to selectively heat a substructure metal powder based on the CAD data with the framework design. A thin layer of the beamed area becomes fused, and the metal framework is completed by laminating these thin layers. Utilizing DMLS system to fabricate fixed prostheses is expected to achieve free-from shaping without mold and limitations from cutting tools, fabricate prostheses with complex geometry, prevent distortion and fabrication defects that inherent to conventional fabrication methods. The purpose of this case report is to demonstrate various fixed prostheses such as long span fixed prostheses, post to achieve satisfactory results in functional and esthetic aspects.

Evaluation of the effectiveness of diode laser therapy in conjunction with nonsurgical treatment of periimplantitis

  • Dicle Altindal;Eylem Ayhan Alkan;Metin Calisir
    • Journal of Periodontal and Implant Science
    • /
    • v.53 no.5
    • /
    • pp.376-387
    • /
    • 2023
  • Purpose: Peri-implantitis (PI) is an inflammatory condition associated with the destruction of bone tissue around a dental implant, and diode lasers can be used to treat this disease. In this study, we aimed to evaluate the effectiveness of a 940-nm diode laser for the nonsurgical treatment of PI. Methods: Twenty patients (8 women and 12 men) were enrolled in a split-mouth randomized controlled study. In the control group (CG), mechanical debridement with titanium curettes accompanied by airflow was performed around the implants. The test group (TG) was treated similarly, but with the use of a diode laser. Clinical measurements (plaque index, gingival index [GI], probing pocket depth [PPD], bleeding on probing [BOP], clinical attachment level, and interleukin-1β [IL-1β] in the peri-implant crevicular fluid) were evaluated and recorded at baseline and 3 months. IL-1β levels were determined using the enzyme-linked immunosorbent assay method. Results: The symptoms were alleviated in both groups at 3 months as assessed through clinical measurements. GI, BOP, and PPD were significantly lower in the TG than in the CG (P<0.05). The IL-1β level increased post-treatment in both groups, but this increase was only statistically significant (P<0.05) in the CG. Conclusions: The diode laser enabled improvements in clinical parameters in the periimplant tissue. However, it did not reduce IL-1β levels after treatment. Further studies about the use of diode lasers in the treatment of PI will be necessary to evaluate the effects of diode lasers in PI treatment.

Wound Healing After Gingivectomy Using Pulsed Nd : YAG Laser In The Rat (백서에서 Pulsed Nd : YAG Laser에 의한 치은절제술후의 치유양상)

  • Kim, Ok-Su;Chung, Hyun-Ju
    • Journal of Periodontal and Implant Science
    • /
    • v.26 no.1
    • /
    • pp.293-308
    • /
    • 1996
  • Recently, dental laser have been applied for removal of soft tissues, hemostasis and blood coagulation, removal of benign and malignant tumor, treatment of leukoplakia, aphthous ulcer and herpetic lesion, implant second surgery, removal of granulation tissue, frenectomy, clinical crown lengthening, gingivectomy, gingivoplasty, and treatment of dentin hypersensitivity. Even though the frequency of laser treatment is increasing, the research on the healing process after gingivectomy using pulsed Nd : YAG laser is very rare. The purpose of this study was to observe and compare the wound healing after gingivectomy using scalpel and pulsed Nd : YAG laser in the rat. Gingivectomy was performed using pulsed Nd : YAG laser(SUNRISE Technologies, U.S.A., 1.5 Watts, 10 pps) on the buccal gingiva of right maxillary first molar and using scalpel(No.12) on the contralateral side. Those sites treated by surgical scalpel were designated as the control, and by pulsed Nd : YAG laser as the experimental group. Animals were sacrificed at 1, 2, 3, 5, 7, 11 and 14 days postoperatively, and specimens were histologically observed under light microscope. The results were as follows : 1. Clinical observation Normal color and shape were observed at the 5th day ill the control group and the 7th day in the experimental group. 2. Histologic findings 1) In the control group, denser inflammatory infiltration was observed. 2) Epithelialization started at the 2nd day in the control group, similar to the experimental group, and completed at the 11th to the 14th day postoperatively. 3) In the experimental group, connective tissue showed the vacuole formation and degenerative change during early healing period. Healing of connective tissue was slower in the experimental group than in the control group by 2 days. 4) In the both groups, wound healing was completed at the 2nd week. From this study, gingivectomy using pulsed Nd : YAG laser seems to result in a little delayed wound healing process, compared to the gingivectomy using scalpel. Considering the clinical advantages of laser surgery, pulsed Nd : YAG laser might be useful device for gingivectomy.

  • PDF

EFFECTS OF ER:YAG LASER ABLATION ON THE DENTIN (Er:YAG 레이저를 이용한 치아삭제 효과)

  • Choi, Nam-Ki;Yang, Kyu-Ho;Park, Sang-Won;Kim, Ok-Joon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.4
    • /
    • pp.683-693
    • /
    • 2001
  • The purpose of this study was to evaluate the effects of Er:YAG laser on cutting efficacy and its histologic findings. Dentin specimens of human premolars and molars were used and irradiated by Er:YAG laser with noncontact handpiece type delivery system under different treatment condition of irradiation time. Cavity pattern and volume were evaluated to determine the cutting efficacy and following results were obtained. 1. Cutting volume of sound dentin was getting larger with time immersed in water increase 2. With the condition of irradiation (150mJ, 10Hz, 30sec), surface irregularity was more increased in sound dentin comparing to carious dentin. For the light microscopic examination, dentinal tubules were opened and ash flecks and cracks were noted with inconsistence of dentinal tubules. 3. In case of 30 sec. irradiation in carious dentin, dark zone was limited to small focus whereas 1 min. irradiation, more wider, and cracks were noted in the perpendicular to direction of dentinal tubules. For the 2 min. irradiation, cavity was the widest and more cracks were found.

  • PDF