• Title/Summary/Keyword: laser dentistry

Search Result 571, Processing Time 0.029 seconds

An Experimental Study on the Effect of Low Level Laser and Some Cytokines on Gene Expression of Human Gingival Fibroblasts (저출력레이저조사와 염증성 자극물질이 치은섬유아세포의 유전자 발현에 미치는 영향에 관한 실험적 연구)

  • Jung-Min Kim;Keum-Back Shin
    • Journal of Oral Medicine and Pain
    • /
    • v.19 no.2
    • /
    • pp.57-71
    • /
    • 1994
  • Gingival fibroblasts were cultured and subjected to the test of Northern blot analysis for the demonstration of various mRNA expression in response to the low level laser treatment. For duplication of in vivo. Wound healing process, fibroblasts were pretreated with proinflammatory cytokine interleukin-1$\beta$(IL-1$\beta$) or mitogenic substance phorbol 12-myristate 13-acetate(PMA) prior to laser irradiation. The results were as follows : 1. By the laser irradiation, the gene expression of collagen type I was markedly increased I n gingival fibroblasts, especially in the case of PMA pretreatment. The gene expression of collagen type IV, however, was not only affected by laser irradiation but also by chemical cell stimulation. 2. Oncogene v-myc expression was affected by both laser irradiation and IL-1$\beta$ or PMA stimulation, But v-fos gene expression was not detected in any case of this experimental system. 3. Heat shock gene(Hsp 70)was expressed constiutively, but slightly increased by laser irradiation. 4. mRNA of fibroblast growth factor(FGF) was induced by both laser irradiation and IL-1$\beta$ or PMA treatment.

  • PDF

Comparisons Fitness in Implant Abutment between Gas Soldering and Laser Welding

  • Cho, Mi-Hyang;Nam, Shin-Eun
    • International Journal of Clinical Preventive Dentistry
    • /
    • v.14 no.4
    • /
    • pp.247-255
    • /
    • 2018
  • Objective: Osseointegration is essential process for successful implants and effects to implant in long term, therefore, passive fitness of good prosthesis is necessary. To make a good prosthesis, at first it should be done a sectioned casting and then joined method of sectioned casting body is recommended. Methods: In this study, to provide the fundamental data on stable connection method for successful implants, the author tested fitness of casting body, and compared difference between gas soldering technique and laser welding technique. Results: In fitness test of 2 abutment (test A, C), gas soldering group's fitness in the opposite part of connection was worse than laser welding group. In fitness test of 3 abutment (test B, D), gap distance was increased both in gas soldering technique and laser welding technique. Gap distance at the connecting part and the opposite part of the abutment in gas soldering technique was worse than laser welding technique and the more additional abutment, the worse gap distance in gas soldering technique. In fitness test of 3 abutment (test B, D), there's little variation in No. 2 abutment when connecting soldering process was done and there's little influence on already soldered connection part when the additional soldering connection was done. Conclusion: On weak loading condition and the part which is needed an accuracy, laser welding technique is more effective and on long-span prosthesis and frequent chewing loading part, laser welding technique is recommended first and applying additional gas soldering technique would be better for making much more successful prosthesis.

LASER application A to Z in general dental practice (일상적 치과진료에서 레이저의 사용 A to Z)

  • Jang, Sung-Yong
    • The Journal of the Korean dental association
    • /
    • v.53 no.12
    • /
    • pp.917-925
    • /
    • 2015
  • LASER application has many advantages in the field of dentistry, however, it is not easy to apply dental LASER in general practice. Various LASER systems are in the market and it is little bit confused which LASER systems are useful. Most of all, it is important to select the appropriate LASER system to their own usage. In the present article, I introduce several LASER system such as $CO_2$, Diode, Nd:YAG, Er:YG, Er,Cr:YSGG, and its application according to specific disease criteria.

Effects of Low Incident Energy Levels of Infrared Laser Irradiation on the Proliferation of Candida Albicans Part III : A Study on the Interval of Irradiation

  • Sam-Kun Kim;Phil-Yeon Lee;Ki-Suk Kim
    • Journal of Oral Medicine and Pain
    • /
    • v.19 no.1
    • /
    • pp.25-31
    • /
    • 1994
  • This study was performed to investigate the biostimulation effects of low level laser therapy (LLLT) on the fungus, Candida alvicans, according to the interval of irradiation during the cell cycle. Samples were divided into 5 groups which were P7-2Hr, P7-4Hr, P15-2Hr, P15-4Hr and Co. Sample was irradiated for 1 minute with 2 hours or 2 minutes with 4 hours of elapsed time during 28 hours of the cell cycle of Candida albicans, and the optical density was assessed by spectrophotometry every 2 hours. It was found that there was significant difference, in the cell growth, between 2 hour and 4 hour interval laser irradiation, although the total energy of each group using identical pulse during exam was equal.

  • PDF

The Effects of Nd:YAG Laser Irradiation on the Root Surface;A Scanning Electron Microscopic Study (Nd:YAG 레이저 조사시 치근면에 미치는 효과에 관한 주사전자현미경적 연구)

  • Lee, Su-Jeong;Kim, Soo-Ah;Seo, Seok-Ran;Kim, Hyung-Seop
    • Journal of Periodontal and Implant Science
    • /
    • v.27 no.3
    • /
    • pp.495-514
    • /
    • 1997
  • The purpose of this study was to evaluate the in vitro effects of Nd:YAG laser irradiation on removal of a root surface smear layer after root planing in comparison with Tetracycline HCl. The 60 extracted human teeth due to severe periodontal disease were vigorously scaled and root planed with Gracey curet. Thirty specimen($5{\times}5{\times}2mm$) were obtained from root planed surface of 30 human teeth and assigned randomly to one of three groups : root planed group(5 specimen), Tetracycline HCI group(5 specimen, burnished for 5 minutes), and Nd:YAG laser group(25 specimen, German Dental Laser, Fotona Twinlight). Nd:YAG laser group was divided into 4 subgroups according to power of 1W, 1.5W, 2W, 3W at frequency to 10Hz. The specimen were then fixed, and examed by Scanning electron microscopic study. 30 of 60 human teeth used to measurement of the intrapulpal temperature rise during laser irradiation. Laser-irradiated surface exhibited various surface texture from relative flat surface to irregular surface with patent dentinal tubules of various shape and size. In some area, the root surface alteration which are carbonization, pit and crater formation and melting and resolidification were observed. The number of exposed dentinal tubules per unit($100_{\mu}m^2$) on tetracycline HCI group was more than that in the laser group below 1.5W of power(150mJ/pulse) and was significantly less than that in laser group above 2W of power(200mJ/pulse)(P<0.OOl). As power increased the intrapulpal temperature rise also increased. The result suggested that the parameter which effectively remove root surface smear layer than tetracycline HCI may cause thermal damage to pulp and root surface alteration result from laser exposure would indicate need for additional instrumentation. Thus, Nd:YAG laser irradiation in these parameter may not be appropriate for clinical use as adjunct to conventional periodontal therapy.

  • PDF

Effect of Nd:YAG Laser Irradiation to Mental Region for Sensory Nerve Conduction Change (하악 이공부에 조사된 Nd:YAG 레이저가 감각신경전도변화에 미치는 영향)

  • Jeon, Jae-Woo;Kim, Kyoung-Hee;Ko, Myong-Yun;Ahn, Yong-Woo;Park, Jun-Sang
    • Journal of Oral Medicine and Pain
    • /
    • v.30 no.4
    • /
    • pp.447-455
    • /
    • 2005
  • The purpose of this study was to examine the effect of Nd:YAG laser irradiation for sensory nerve conduction change. Nd:YAG laser was irradiated to mental region for 5 minutes with the parameters that 10 Hz and 20 Hz of 100 mJ/pulse. Target size of irradiation was 30 mm diameter of circle and target-tip distance was about 10 mm. Therefore, the power density were 212 $mW/cm^2$ and 424 $mW/cm^2$. Sensory nerve conduction was evaluated with $Neurometer^{\circled}$ CPT/C before and after Nd:YAG laser irradiation. As an outcomes, the current perception threshold(CPT) and pain tolerance threshold(PTT) were obtained. We made a comparison of these two values and the results were as follows. 1. There was no significant difference in CPT at 1W, 10 Hz and 2 W, 20 Hz Nd:YAG laser irradiation. 2. There was no significant difference in PTT at 10 Hz, 20 Hz of 100 mJ/pulse Nd:YAG laser. 3. There were no significant differences in CPT and PTT between 1 W, 10 Hz group and 2 W, 20 Hz group. Therefore, We can make a conclusion that Nd:YAG laser irradiation to mental region have no effect on mental nerve conduction in our study model.

A STUDY OF SHEAR BOND STRENGTH OF ER:YAG LASER-IRRADIATED PRIMARY DENTIN (Er:YAG 레이저를 조사한 유치 상아질의 전단결합강도에 관한 연구)

  • Lee, Jin-Hwa;Kim, Jong-Soo;Yoo, Seung-Hoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.4
    • /
    • pp.569-578
    • /
    • 2007
  • This study was performed to compare the shear bond strength of self etching system and two bottle bonding system with or without laser preparation. Group I was prepared with high speed rotary instrument and $Prompt^{TM}$ L-$Pop^{TM}$, group II with Er:YAG laser and $Prompt^{TM}$ L-$Pop^{TM}$, group III with Er:YAG laser, 37% phosphoric acid and Single bond, group IV with Er:YAG laser and Single bond and group V with high speed, etching and Single bond. And also observation of the prepared and etched dentin surface were performed under scanning electro-microscope. The possibility of clinical application of laser preparation which might have an advantage to reduce pain for children with less unfavorable noise were evaluated. The results obtained are as follows; 1. Group V showed significantly higher bond strength than other groups. And group IV showed significantly lower bond strength than other groups. 2. There was no significant difference between group I and group III. 3. Group II showed significantly lower bond strength than group I, III, V, but showed significantly higher bond strength than group IV. 4. Under scanning electro-microscope, laser-preparated dentin surface showed high irregularity and no smear layer. The surface showed less irregularities and more exposed dentinal tubules with etching. Laser preparation has many advantages over conventional tooth preparation. But this method showed lower resin bonding strength. Laser preparated tooth surface differed from the conventionally preparated tooth surface. More researches are needed on suitable methods for laser preparated dentin surface.

  • PDF

The effect of using nanoparticles in bioactive glass on its antimicrobial properties

  • Maram Farouk Obeid;Kareim Moustafa El-Batouty;Mohammed Aslam
    • Restorative Dentistry and Endodontics
    • /
    • v.46 no.4
    • /
    • pp.58.1-58.8
    • /
    • 2021
  • Objectives: This study addresses the effect of using nanoparticles (np) on the antimicrobial properties of bioactive glass (BAG) when used in intracanal medicaments against Enterococcus faecalis (E. faecalis) biofilms. Materials and Methods: E. faecalis biofilms, grown inside 90 root canals for 21 days, were randomly divided into 4 groups according to the antimicrobial regimen followed (n = 20; BAG-np, BAG, calcium hydroxide [CaOH], and saline). After 1 week, residual live bacteria were quantified in terms of colony-forming units (CFU), while dead bacteria were assessed with a confocal laser scanning microscope. Results: Although there was a statistically significant decrease in the mean CFU value among all groups, the nano-group performed the best. The highest percentage of dead bacteria was detected in the BAG-np group, with a significant difference from the BAG group. Conclusions: The reduction of particle size and use of a nano-form of BAG improved the antimicrobial properties of the intracanal treatment of E. faecalis biofilms